962 resultados para metals in urine
Resumo:
in this work, a simple method for the simultaneous determination of cocaine (COC) and five COC metabolites (benzoylecgonine, cocaethylene (CET), anhydroecgonine, anhydroecgonine methyl ester and ecgonine methyl ester) in human urine using CE coupled to MS via electrospray ionization (CE-ESI-MS) was developed and validated. Formic acid at 1 mol/L concentration was used as electrolyte whereas formic acid at 0.05 mol/L concentration in 1:1 methanol:water composed the coaxial sheath liquid at the ESI nozzle. The developed method presented good linearity in the dynamic range from 250 ng/mL to 5000 ng/mL (coefficient of determination greater than 0.98 for all compounds). LODs (signal-to-noise ratio of 3) were 100 ng/mL for COC and CET and 250 ng/mL for the other studied metabolites whereas LOQ`s (signal-to-noise ratio of 10) were 250 ng/mL for COC and CET and 500 ng/mL for all other compounds. Intra-day precision and recovery tests estimated at three different concentration levels (500, 1500 and 5000 ng/mL) provided RSD lower than 10% (except anhydroecgonine, 18% RSD) and recoveries from 83-109% for all analytes. The method was successfully applied to real cases. For the positive urine samples, the presence of COC and its` metabolites was further confirmed by MS/MS experiments.
Resumo:
This paper describes the development, electrochemical characterization and utilization of a cobalt phthalocyanine (CoPc), modified multi-walled carbon nanotube (MWCNT), and paraffin composite electrode for the quantitative determination of epinephrine (EP) in human urine samples. The electrochemical profile of the proposed composite electrode was analyzed by differential pulse voltammetry (DPV) that showed a shift of the oxidation peak potential of EP at 175 mV to less positive value, compared with a paraffin/graphite composite electrode without CoPc. DPV experiments in PBS at pH 6.0 were performed to determine EP without any previous step of extraction, clean-up, and derivatization, in the range from 1.33 to 5.50 mu mol L(-1), with a detection limit of 15.6 nmol L(-1) (2.86) of EP in electrolyte prepared with purified water. The lifetime of the proposed sensors was at least over 1000 determinations with 1.7 and 3.1 repeatability and reproducibility relative standard deviations, respectively. Human urine samples without any purification step were successfully analyzed under the standard addition method using paraffin/MWCNT/CoPc composite electrode. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
2-Aminothiazole covalently attached to a silica gel surface was prepared in order to obtain an adsorbent for Hg(II) ions having the following characteristics: good sorption capacity, chemical stability under conditions of use, and, especially, high selectivity. The accumulation voltammetry of mercury(II) was investigated at a carbon paste electrode chemically modified with silica gel functionalized with 2-aminothiazole (SIAMT-CPE). The repetitive cyclic voltammogram of mercury(II) solution in the potential range -0.2 to + 0.6 V versus Ag/AgCl (0.02 mol L-1 KNO3; V = 20 mV s(-1)) show two peaks one at about 0.1 V and other at 0.205 V. The anodic wave peak at 0.205 V is well defined and does not change during the cycles and it was therefore further investigated for analytical purposes using differential pulse anodic stripping voltammetry in differents supporting electrolytes. The mercury response was evaluated with respect to pH, electrode composition, preconcentration time, mercury concentration, cleaning solution, possible interferences and other variables. The precision for six determinations (n = 6) of 0.02 and 0.20 mg L-1 Hg(II) was 4.1 and 3.5% (relative standard deviation), respectively. The detection limit was estimated as 0.10 mu g L-1 mercury(II) by means of 3:1 current-to-noise ratio in connection with the optimization of the various parameters involved and using the highest-possible analyser sensitivity. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This pilot study uses concentrations of metals in maternal and cord blood at delivery, in seven selected geographical areas of South Africa, to determine prenatal environmental exposure to toxic metals. Samples of maternal and cord whole blood were analysed for levels of cadmium, mercury, lead, manganese, cobalt, copper, zinc, arsenic and selenium. Levels of some measured metals differed by site, indicating different environmental pollution levels in the regions selected for the study. Mercury levels were elevated in two coastal populations studied (Atlantic and Indian Ocean sites) with mothers from the Atlantic site having the highest median concentration of 1.78 mu g/L ranging from 0.44 to 8.82 mu g/L, which was found to be highly significant (p < 0.001) when compared to other sites, except the Indian Ocean site. The highest concentration of cadmium was measured in maternal blood from the Atlantic site with a median value of 0.25 mu g/L (range 0.05-0.89 mu g/L), and statistical significance of p < 0.032, when compared to all other sites studied, and p < 0.001 and p < 0.004 when compared to rural and industrial sites respectively, confounding factor for elevated cadmium levels was found to be cigarette smoking. Levels of lead were highest in the urban site, with a median value of 32.9 mu g/L (range 16-81.5 mu g/L), and statistically significant when compared with other sites (p < 0.003). Levels of selenium were highest in the Atlantic site reaching statistical significance (p < 0.001). All analysed metals were detected in umbilical cord blood samples and differed between sites, with mercury being highest in the Atlantic site (p < 0.001), lead being highest in the urban site (p < 0.004) and selenium in the Atlantic site (p < 0.001). To the best of our knowledge this pilot investigation is the first study performed in South Africa that measured multiple metals in delivering mothers and umbilical cord blood samples. These results will inform the selection of the geographical sites requiring further investigation in the main study.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Bioaccumulation of metals in aquatic insects of streams located in areas with sugar cane cultivation
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A aplicação do lodo de estação de tratamento de água (LETA) em solos degradados é uma alternativa tanto para disposição desse resíduo como para a recuperação do solo. Neste trabalho avaliaram-se os efeitos do LETA nos teores de metais pesados em um Latossolo degradado por mineração de cassiterita na Floresta Nacional do Jamari, RO, Brasil. Utilizou-se delineamento experimental inteiramente casualizado com cinco tratamentos: testemunha (n = 4); testemunha química, que recebeu apenas calagem (n = 4) e doses D100, D150 e D200 (respectivamente 100, 150 e 200 mg de N kg-1 solo na forma de LETA), aplicadas antes da calagem (n = 20). Após 30 dias da calagem, período em que o solo contido nos vasos foi mantido com teor de umidade próximo à capacidade de retenção, coletaram-se amostras de solo, que foram analisadas com relação aos teores totais e extraíveis de Fe, Cu, Mn, Zn, Cd, Pb, Ni e Cr. A aplicação de LETA aumentou os teores dos metais pesados do solo. A aplicação deste tipo de lodo em áreas degradadas pode causar impacto ambiental e, portanto, deve ser monitorada.
Resumo:
A method was developed for the differential-pulse cathodic stripping voltammetric determination of ceftazidime with a hanging mercury drop electrode using its reduction peak at -0.43 V in Britton-Robinson buffer pH 4.0. The optimum accumulation potential and time were -0.15 V and up to 60 s, respectively. Linear calibration graphs were obtained from 1 x 10(-8) M and 1.5 x 10(-7) M. The limit of determination was calculated to be 5 x 10(-9) M. The coefficient of variation was 4% (n = 7) at 1 x 10(-7) M ceftazidime. The effect of various components of urine on the voltammetric response was studied, and creatinine, uric acid, urea, and glucose were shown to interfere in the method. Ceftazidime bound to human albumin gives a unique stripping peak at -0.48 V. Recoveries of 87% +/- 2% of the ceftazidime (n = 5) were obtained from urine spiked with 1.27 mu g ml(-1) using C-18 solid phase extraction cartridges. (C) 1997 Academic Press.
Resumo:
This work describes an electroanalytical method for determining gold(I) thiomalate, aurothiomalate, widely used for treatment of reumatoid arthiritis, using a screen-printed carbon electrode (SPCE). Aurothiomalate (AuTM) was determined indirectly at the same electrode by accumulating it first at -1.5 V vs. printed carbon. At this potential in the adsorbed state, the AuTM is reduced to Au(0), which is then oxidized at two steps at -0.22 V and +0.54 V on SPCE. Using optimized conditions of 60 s deposition time, -1.5 V (vs. printed carbon) accumulation potential, 100 mV s(-1) scan rate, linear calibration graphs can be obtained by monitoring the peak at +0.54 V for AuTM in HCl 0.1 mol L-1 from 1.43 x 10(-6) to 1.55 x 10(-4) mol L-1. A limit of detection obtained was 6.50 x 10(-7) mol L-1, and the relative standard deviation from five measurements of 3.0 x 10(-5) mol L-1 AuTM is 4.5%. The method was successfully applied for AuTM determination in human urine sample.
Resumo:
Ceftazidime shows two main polarographic reduction peaks at pH 4.0, that at -0.45 V owing to reduction of the C=N bond in the methylethoxyimino group and that at -1.00 V owing to the reductive elimination of pyridine: the first peak is particularly suitable for the determination of ceftazidime. Ceftazidime can also be determined indirectly using the tensammetric peak at -0.60 V (in Britton-Robinson buffer pH 9.5) of pyridine liberated on hydrolysis. Ceftazidime can be determined in urine using the direct method only after Cls solid phase extraction, but it can be determined directly in the urine by hydrolysing it and using the pyridine peak. (C) 1997 Elsevier B.V. B.V.
Resumo:
The original model of Das et al. is modified in extending the electron-ion interaction on a three-body forces and including the crystal equilibrium condition to reduce one independent parameter. We studied the phonon dispersion relations along the three principal symmetry directions i.e. [xi, 0, 0], [xi, xi, 0] and [xi, xi, xi] and theta-T curves of alkali metals, Na, K, Rb, Cs and Li. There is close agreement between the computed results and the experimental observations.