860 resultados para laser dual-frequency interferometer


Relevância:

100.00% 100.00%

Publicador:

Resumo:

GPS precise point positioning (PPP) can provide high precision 3-D coordinates. Combined pseudorange and carrier phase observables, precise ephemeris and satellite clock corrections, together with data from dual frequency receivers, are the key factors for providing such levels of precision (few centimeters). In general, results obtained from PPP are referenced to an arbitrary reference frame, realized from a previous free network adjustment, in which satellite state vectors, station coordinates and other biases are estimated together. In order to obtain consistent results, the coordinates have to be transformed to the relevant reference frame and the appropriate daily transformation parameters must be available. Furthermore, the coordinates have to be mapped to a chosen reference epoch. If a velocity field is not available, an appropriated model, such as NNR-NUVEL-IA, has to be used. The quality of the results provided by this approach was evaluated using data from the Brazilian Network for Continuous Monitoring of the Global Positioning System (RBMC), which was processed using GIPSY-OASIS 11 software. The results obtained were compared to SIRGAS 1995.4 and ITRF2000, and reached precision better than 2cm. A description of the fundamentals of the PPP approach and its application in the integration of regional GPS networks with ITRF is the main purpose of this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When GNSS receivers capable of collecting dual-frequency data are available, it is possible to eliminate the first-order ionospheric effect in the data processing through the ionosphere-free linear combination. However, the second- and third-order ionospheric effects still remain. The first-, second- and third-order ionospheric effects are directly proportional to the total electron content (TEC), although the second- and third-order effects are influenced, respectively, by the geomagnetic field and the maximum electron density. In recent years, the international scientific community has given more attention to these kinds of effects and some works have shown that for high precision GNSS positioning these effects have to be taken into consideration. We present a software tool called RINEX_HO that was developed to correct GPS observables for second- and third-order ionosphere effects. RINEX_HO requires as input a RINEX observation file, then computes the second- and third-order ionospheric effects, and applies the corrections to the original GPS observables, creating a corrected RINEX file. The mathematical models implemented to compute these effects are presented, as well as the transformations involving the earth's magnetic field. The use of TEC from global ionospheric maps and TEC calculated from raw pseudorange measurements or pseudoranges smoothed by phase is also investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cada vez mais é crescente o uso do GPS (Global Positioning System ) em estudos da atmosfera terrestre. Neste artigo, a atmosfera superior da Terra, denominada ionosfera, foi estudada durante um período de alta atividade solar (ano de 2001) usando dados de receptores GPS de dupla freqüência localizados na região brasileira, pertencentes à RBMC (Rede Brasileira de Monitoramento Contínuo). A partir dos dados GPS foram calculados os valores de TEC (Total Electron Content - Conteúdo Total de Elétrons) da ionosfera. Adicionalmente foram incluídos no estudo dados de freqüência crítica da camada F2 advinda de Digissondas localizadas em São Luís/MA (3ºS; 44ºW) e Cachoeira Paulista/SP (22ºS; 45ºW), para fins de comparação. de uma forma geral, os resultados mostraram maiores valores de TEC durante os meses próximos aos equinócios e menores durante os meses de inverno. Quanto à variação diária do TEC, os menores valores foram verificados por volta das 4-6 HL (Hora Local) e os maiores durante o período da tarde, com valores um pouco maiores para São Luís. O segundo pico da anomalia equatorial foi verificado em Cachoeira Paulista nos meses próximos aos equinócios e verão. Na maioria dos meses, uma alta correlação linear foi verificada quando realizada a comparação entre os valores de freqüência crítica da camada F2 e os de TEC, principalmente para São Luís.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Throughout late 1998 and early 1999, the International GLONASS Experiment (IGEX) has delivered the first comprehensive inter-continental dual frequency GLONASS data set. This experiment represents the first opportunity to assess how a second global satellite positioning system could complement existing CPS geodetic infrastructure. Based on analysis of a three station network of IGEX stations from Southern Hemisphere IGEX stations, this paper discusses the internal and external precision of long baseline GPS, GLONASS and combined GPS/GLONASS solutions, and the possible contribution of GLONASS to future regional-scale geodetic work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Brazilian Network for Continuous Monitoring of GPS - RBMC, since its foundation in December of 1996, has been playing an essential role for the maintenance and user access of the fundamental geodetic frame in the country,. It provides users with a direct link to the Brazilian Geodetic System - SGB. Its role has become more relevant with the increasing use of space navigation technology in the country. Recently, Brazil adopted a new geodetic system, SIRGAS2000, in February 2005, fully compatible with GNSS technology. The paper provides an overview of the recent modernization phases the RBMC network has undergone highlighting its future steps. From its current post-mission mode, the RBMC will evolve into a real-time network, providing real-time data and real-time correction to users. The network enhanced with modern GPS receivers and the addition of atomic clocks will be used to compute WADGPS-type corrections to be transmitted, in real time, to users in Brazil and surrounding areas. It is estimated that users will be able to achieve a horizontal accuracy around 0.5 m (1σ) in static and kinematic positioning and better for dual frequency users. The availability of the WADGPS service will allow users to tie to the new SIRGAS2000 system in a more rapid and transparent way for positioning and navigation applications. It should be emphasized that support to post-mission static positioning will continue to be provided to users interested in higher accuracy levels. In addition to this, a post-mission Precise Point Positioning (PPP) service will be provided based on the one currently provided by the Geodetic Survey Division of NRCan (CSRS-PPP). The modernization of the RBMC is under development based on a cooperation signed at the end of 2004 with the University of New Brunswick, supported by the Canadian International Development Agency and the Brazilian Cooperation Agency. The Geodetic Survey Division of NRCan is also participating in this modernization effort under the same project.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Brazilian Network for Continuous Monitoring of GPS - RBMC, since its foundation in December of 1996, has been playing an essential role for the maintenance and user access of the fundamental geodetic frame in the country. It provides to users a direct link to the Brazilian Geodetic System. Its role has become more relevant with the increasing use of space navigation technology in the country. Recently, Brazil adopted a new geodetic frame, SIRGAS2000, in February 2005, fully compatible with GNSS technology. The paper provides an overview of the recent modernization phases the RBMC network has undergone highlighting its future steps. From its current post-mission mode, the RBMC will evolve into a real-time network, providing real-time data and real-time correction to users. The network enhanced with modern GPS receivers and the addition of atomic clocks will be used to compute WADGPS-type corrections to be transmitted, in real time, to users in Brazil and surrounding areas. It is estimated that users will be able to achieve a horizontal accuracy around 0.5 m (1 σ) in static and kinematic positioning and better for dual frequency users. The availability of the WADGPS service will allow users to tie to the new SIRGAS2000 frame in a more rapid and transparent way for positioning and navigation applications. It should be emphasized that support to post-mission static positioning, will continue to be provided to users interested in higher accuracy levels. In addition to this, a post-mission Precise Point Positioning (PPP) service will be provided based on the one currently provided by the Geodetic Survey Division of NRCan (CSRS-PPP). The modernization of the RBMC is under development based on a cooperation signed at the end of 2004 with the University of New Brunswick, supported by the Canadian International Development Agency and the Brazilian Cooperation Agency. The Geodetic Survey Division of NRCan is also participating in this modernization effort under the same project. © Springer-Verlag Berlin Heidelberg 2009.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we describe the development of a low-cost high-accuracy Galileo Code receiver, user application software and positioning algorithms for land management applications, which have been implemented using a dedicated FPGA board and dual frequency Galileo E5/L1 Radio Frequency Front-End. The current situation of rural property surveying in Brazil is described and the use of code measurements from the new Galileo signals E5 AltBOC combined with E1 MBOC for use in land management applications is explored. We explain how such approach is expected to allow delivering an absolute positioning solution which could bridge the gap between receivers of high cost/complexity/accuracy based on carrier phase and receivers of lower cost/accuracy based on pseudorange observables. The system is presented together with a detailed description of main components: the Code Receiver and the Application Software. The work presented is part of an ongoing European-Brazilian consortium effort to explore the use of new Galileo for land management applications in Brazil and sponsored by the GNSS Supervisory Authority (GSA).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Observable GNSS (Global Navigation Satellite System) are affected by systematic errors due to free electrons present in the ionosphere. The error associated with the ionosphere depends on the Total Electron Content (TEC), which is influenced by several variables: solar cycle, season, local time, geomagnetic activity and geographic location. The GPS (Global Positioning System), GLONASS (Global Orbiting Navigation Satellite System) and Galileo dual frequency receivers allow the calculation of the error that affects the GNSS observables and the TEC. Using the rate of change of TEC (ROT - Rate of TEC) indices that indicate irregularities of the ionosphere can be determined, allowing inferences about its behavior. Currently it is possible to perform such studies in Brazil, due to the several Active Networks available, such as RBMC/RIBaC (Rede Brasileira de Monitoramento Contínuo/Rede INCRA de Bases Comunitárias) and GNSS Active Network of São Paulo. The proposed research aimed at estimating and analysing of indexes of irregularities of the ionosphere, besides supplying the geosciences of information about the behavior of the ionosphere.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aiming to evaluate the methodologies of surveys related with the specifications of Geo-referencing Rural Parcels in Brazil, established by INCRA (National Institute of Colonization and Agrarian Reform), in attendance to the Law 10.267/01, and considering aspects of precision and accuracy, a test area was set up in the Assentamento Florestan Fernandes, in the county of Presidente Bernardes, SP. This area was subdivided in three sub-areas in order to simulate the existence of three contiguous rural parcels. The first stage of work consisted in the implantation and determination of the control points coordinates in their respective areas. These control points were determined by the process of direct transport, using dual frequency (L1/L2) GPS receivers and through the process of traverse with baselines of up to 20 km, using single frequency receivers (L1). The coordinates of the points of the perimeter of the three sub-areas were determined using single frequency GPS receivers, from two survey methods, both using static relative positioning. The first one, so called traverse, each point that delimits the property was occupied successively, starting from the control point and closing at another. In other, denominated double irradiation, each point of the property was irradiated from two control points. These procedures were accomplished with the intention to define and to implement a mistake control strategy, to realize redundancy measurements and to use an adjustment method correctly, to obtain trustworthily values in the patterns demanded in each kind of survey. With the data collected and processed some analyses could be accomplished from the discrepancies between the coordinates obtained by different methodologies. The results show that this test area may be used to validate other methodologies and equipments. The results were satisfactory and attended the specifications of Geo-referencing Rural Parcel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ground-based Earth troposphere calibration systems play an important role in planetary exploration, especially to carry out radio science experiments aimed at the estimation of planetary gravity fields. In these experiments, the main observable is the spacecraft (S/C) range rate, measured from the Doppler shift of an electromagnetic wave transmitted from ground, received by the spacecraft and coherently retransmitted back to ground. If the solar corona and interplanetary plasma noise is already removed from Doppler data, the Earth troposphere remains one of the main error sources in tracking observables. Current Earth media calibration systems at NASA’s Deep Space Network (DSN) stations are based upon a combination of weather data and multidirectional, dual frequency GPS measurements acquired at each station complex. In order to support Cassini’s cruise radio science experiments, a new generation of media calibration systems were developed, driven by the need to achieve the goal of an end-to-end Allan deviation of the radio link in the order of 3×〖10〗^(-15) at 1000 s integration time. The future ESA’s Bepi Colombo mission to Mercury carries scientific instrumentation for radio science experiments (a Ka-band transponder and a three-axis accelerometer) which, in combination with the S/C telecommunication system (a X/X/Ka transponder) will provide the most advanced tracking system ever flown on an interplanetary probe. Current error budget for MORE (Mercury Orbiter Radioscience Experiment) allows the residual uncalibrated troposphere to contribute with a value of 8×〖10〗^(-15) to the two-way Allan deviation at 1000 s integration time. The current standard ESA/ESTRACK calibration system is based on a combination of surface meteorological measurements and mathematical algorithms, capable to reconstruct the Earth troposphere path delay, leaving an uncalibrated component of about 1-2% of the total delay. In order to satisfy the stringent MORE requirements, the short time-scale variations of the Earth troposphere water vapor content must be calibrated at ESA deep space antennas (DSA) with more precise and stable instruments (microwave radiometers). In parallel to this high performance instruments, ESA ground stations should be upgraded to media calibration systems at least capable to calibrate both troposphere path delay components (dry and wet) at sub-centimetre level, in order to reduce S/C navigation uncertainties. The natural choice is to provide a continuous troposphere calibration by processing GNSS data acquired at each complex by dual frequency receivers already installed for station location purposes. The work presented here outlines the troposphere calibration technique to support both Deep Space probe navigation and radio science experiments. After an introduction to deep space tracking techniques, observables and error sources, in Chapter 2 the troposphere path delay is widely investigated, reporting the estimation techniques and the state of the art of the ESA and NASA troposphere calibrations. Chapter 3 deals with an analysis of the status and the performances of the NASA Advanced Media Calibration (AMC) system referred to the Cassini data analysis. Chapter 4 describes the current release of a developed GNSS software (S/W) to estimate the troposphere calibration to be used for ESA S/C navigation purposes. During the development phase of the S/W a test campaign has been undertaken in order to evaluate the S/W performances. A description of the campaign and the main results are reported in Chapter 5. Chapter 6 presents a preliminary analysis of microwave radiometers to be used to support radio science experiments. The analysis has been carried out considering radiometric measurements of the ESA/ESTEC instruments installed in Cabauw (NL) and compared with the requirements of MORE. Finally, Chapter 7 summarizes the results obtained and defines some key technical aspects to be evaluated and taken into account for the development phase of future instrumentation.