986 resultados para inductively coupled plasma methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hedley er al. (1982) developed what has become the most widely used land modified), phosphorus (P) fractionation technique. It consists of sequential extraction of increasingly less phytoavailable P pools. Extracts are centrifuged at up to 25000 g (RCF) and filtered to 0.45 mu m to ensure that soil is not lost between extractions. In attempting to transfer this method to laboratories with limited facilities, it was considered that access to high-speed centrifuges, and the cost of frequent filtration may prevent adoption of this P fractionation technique. The modified method presented here was developed to simplify methodology, reduce cost, and therefore increase accessibility of P fractionation technology. It provides quantitative recovery of soil between extractions, using low speed centrifugation without filtration. This is achieved by increasing the ionic strength of dilute extracts, through the addition of NaCl, to flocculate clay particles. Addition of NaCl does not change the amount of P extracted. Flocculation with low speed centrifugation produced extracts comparable with those having undergone filtration (0.025 mu m). A malachite green colorimetric method was adopted for inorganic P determination, as this simple manual method provides high sensitivity with negligible interference from other anions. This approach can also be used for total P following digestion, alternatively non-discriminatory methods, such as inductively coupled plasma atomic emission spectroscopy, may be employed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lead (Pb) contamination in the black paper that recovers intraoral films (BKP) has been investigated. BKP samples were collected from the Radiology Clinics of the Dental School of Ribeirao Preto, University of Sao Paulo, Brazil. For sake of comparison, four different methods were used. The results revealed the presence of high lead levels, well above the maximum limit allowed by the legislation. Pb contamination levels achieved after the following treatments: paper digestion in nitric acid, microwave treatment, DIN38414-54 method and TCLP method were 997 mu g g(-1), 189 mu g g(-1), 20.8 mu g g(-1), and 54.0 mu g g(-1), respectively. Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma mass spectrometry (ICP-MS) were employed for lead determination according to the protocols of the applied methods. Lead contamination in used BKP was confirmed by scanning electron microscopy coupled with energy dispersive X-ray microanalysis (SEM-EDS). All the SEM imaging was carried out in the secondary electron mode (SE) and backscattered-electron mode (QBSD) following punctual X-ray fluorescence spectra. Soil contamination derived from this product revealed the urgent need of addressing this problem. These elevated Pb levels, show that a preliminary treatment of BKP is mandatory before it is disposed into the common trash. The high lead content of this material makes its direct dumping into the environment unwise. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Project: Serum samples may not be appropriate to assess lead (Pb) concentrations because they may contain artificially higher Pb concentrations compared with those measured in plasma samples. Here, we compared Pb concentrations in serum versus heparin plasma separated from blood collected with or without vacuum. We have also examined the effects of sample standing time on Pb concentrations measured in serum, heparin plasma, and EDTA plasma. Procedure: We studied plasma and serum samples from twelve healthy subjects. Blood samples were collected via venous drainage phlebotomy with and without vacuum into trace metal free tubes containing no anticoagulants (serum), or lithium heparin, or EDTA (to obtain plasma). Variable sample standing times (0, 5, and 30 min) prior to centrifugation were allowed. Plasma and serum Pb and iron concentrations were determined by inductively coupled plasma mass spectrometry. Plasma and serum cell-free hemoglobin concentrations were measured. Results: Pb concentrations in serum and in heparin plasma from blood samples collected with or without vacuum were similar and not associated with significant changes in iron or hemoglobin concentrations. The sample standing time (up to 30 min) did not affect Pb concentrations in serum or in heparin plasma, which were approximately 50% lower than those found in EDTA plasma. Conclusions: Serum or heparin plasma separated from blood samples collected via venous phlebotomy with or without vacuum are appropriate medium to assess Pb concentrations, independently of the sample standing time. (C) 2010 Elsevier GmbH. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze household risk factors associated with high lead levels in surface dental enamel. METHODS: A cross-sectional study was conducted with 160 Brazilian adolescents aged 14-18 years living in poor neighborhoods in the city of Bauru, southeastern Brazil, from August to December 2008. Body lead concentrations were assessed in surface dental enamel acid-etch microbiopsies. Dental enamel lead levels were measured by graphite furnace atomic absorption spectrometry and phosphorus levels were measured by inductively coupled plasma optical emission spectrometry. The parents answered a questionnaire about their children's potential early (05 years old) exposure to well-known lead sources. Logistic regression was used to identify associations between dental enamel lead levels and each environmental risk factor studied. Social and familial covariables were included in the models. RESULTS: The results suggest that the adolescents studied were exposed to lead sources during their first years of life. Risk factors associated with high dental enamel lead levels were living in or close to a contaminated area (OR = 4.49; 95% CI: 1.69;11.97); and member of the household worked in the manufacturing of paints, paint pigments, ceramics or batteries (OR = 3.43; 95% CI: 1.31;9.00). Home-based use of lead-glazed ceramics, low-quality pirated toys, anticorrosive paint on gates and/or sale of used car batteries (OR = 1.31; 95% CI: 0.56;3.03) and smoking (OR = 1.66; 95% CI: 0.52;5.28) were not found to be associated with high dental enamel lead levels. CONCLUSIONS: Surface dental enamel can be used as a marker of past environmental exposure to lead and lead concentrations detected are associated to well-known sources of lead contamination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background & aims - Patients who underwent endoscopic gastrostomy (PEG) present protein-energy malnutrition, but little is known about Trace Elements (TE), Zinc (Zn), Copper (Cu), Selenium (Se), Iron (Fe), Chromium (Cr). Our aim was the evaluation of serum TE in patients who underwent PEG and its relationship with serum proteins, BMI and nature of underlying disorder. Methods - A prospective observational study was performed collecting: patient's age, gender, underlying disorder, NRS-2002, BMI, serum albumin, transferrin and TE concentration. We used ferrozine colorimetric method for Fe; Inductively Coupled Plasma-Atomic Emission Spectroscopy for Zn/Cu; Furnace Atomic Absorption Spectroscopy for Se/Cr. The patients were divided into head and neck cancer (HNC) and neurological dysphagia (ND). Results - 146 patients (89 males), 21–95 years: HNC-56; ND-90. Low BMI in 78. Low values mostly for Zn (n = 122) and Fe (n = 69), but less for Se (n = 31), Cu (n = 16), Cr (n = 7); low albumin in 77, low transferrin in 94 and 66 with both proteins low. Significant differences between the groups of underlying disease only for Zn (t140.326 = −2,642, p < 0.01) and a correlation between proteins and TE respectively albumin and Zn (r = 0.197, p = 0.025), and albumin and Fe (r = 0.415, p = 0.000). Conclusions - When gastrostomy was performed, patients display low serum TE namely Zn, but also Fe, less striking regarding others TE. It was related with prolonged fasting, whatever the underlying disease. Low proteins were associated with low TE. Teams taking care of PEG-patients should use Zn supplementation and include other TE evaluation as part of the nutritional assessment of PEG candidates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND & AIMS: Patients who underwent endoscopic gastrostomy (PEG) present protein-energy malnutrition, but little is known about Trace Elements (TE), Zinc (Zn), Copper (Cu), Selenium (Se), Iron (Fe), Chromium (Cr). Our aim was the evaluation of serum TE in patients who underwent PEG and its relationship with serum proteins, BMI and nature of underlying disorder. METHODS: A prospective observational study was performed collecting: patient's age, gender, underlying disorder, NRS-2002, BMI, serum albumin, transferrin and TE concentration. We used ferrozine colorimetric method for Fe; Inductively Coupled Plasma-Atomic Emission Spectroscopy for Zn/Cu; Furnace Atomic Absorption Spectroscopy for Se/Cr. The patients were divided into head and neck cancer (HNC) and neurological dysphagia (ND). RESULTS: 146 patients (89 males), 21-95 years: HNC-56; ND-90. Low BMI in 78. Low values mostly for Zn (n = 122) and Fe (n = 69), but less for Se (n = 31), Cu (n = 16), Cr (n = 7); low albumin in 77, low transferrin in 94 and 66 with both proteins low. Significant differences between the groups of underlying disease only for Zn (t140.326 = -2,642, p < 0.01) and a correlation between proteins and TE respectively albumin and Zn (r = 0.197, p = 0.025), and albumin and Fe (r = 0.415, p = 0.000). CONCLUSIONS: When gastrostomy was performed, patients display low serum TE namely Zn, but also Fe, less striking regarding others TE. It was related with prolonged fasting, whatever the underlying disease. Low proteins were associated with low TE. Teams taking care of PEG-patients should use Zn supplementation and include other TE evaluation as part of the nutritional assessment of PEG candidates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction The aim of this study was to explore the environment of Echinococcus granulosus (E. granulosus) protoscolices and their relationship with their host. Methods Proteins from the hydatid-cyst fluid (HCF) from E. granulosus were identified by proteomics. An inductively coupled plasma atomic emission spectrometer (ICP-AES) was used to determine the elements, an automatic biochemical analyzer was used to detect the types and levels of biochemical indices, and an automatic amino acid analyzer was used to detect the types and levels of amino acids in the E. granulosus HCF. Results I) Approximately 30 protein spots and 21 peptide mass fingerprints (PMF) were acquired in the two-dimensional gel electrophoresis (2-DE) pattern of hydatid fluid; II) We detected 10 chemical elements in the cyst fluid, including sodium, potassium, calcium, magnesium, copper, and zinc; III) We measured 19 biochemical metabolites in the cyst fluid, and the amount of most of these metabolites was lower than that in normal human serum; IV) We detected 17 free amino acids and measured some of these, including alanine, glycine, and valine. Conclusions We identified and measured many chemical components of the cyst fluid, providing a theoretical basis for developing new drugs to prevent and treat hydatid disease by inhibiting or blocking nutrition, metabolism, and other functions of the pathogen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de mestrado em Técnicas de Caracterização e Análise Química

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Occupational risks, the present nuclear threat, and the potential danger associated with nuclear power have raised concerns regarding the metabolism of plutonium in pregnant women. OBJECTIVE: We measured plutonium levels in the milk teeth of children born between 1951 and 1995 to assess the potential risk that plutonium incorporated by pregnant women might pose to the radiosensitive tissues of the fetus through placenta transfer. METHODS: We used milk teeth, whose enamel is formed during pregnancy, to investigate the transfer of plutonium from the mother's blood plasma to the fetus. We measured plutonium using sensitive sector field inductively coupled plasma mass spectrometry techniques. We compared our results with those of a previous study on strontium-90 ((90)Sr) released into the atmosphere after nuclear bomb tests. RESULTS: Results show that plutonium activity peaks in the milk teeth of children born about 10 years before the highest recorded levels of plutonium fallout. By contrast, (90)Sr, which is known to cross the placenta barrier, manifests differently in milk teeth, in accordance with (90)Sr fallout deposition as a function of time. CONCLUSIONS: These findings demonstrate that plutonium found in milk teeth is caused by fallout that was inhaled around the time the milk teeth were shed and not from any accumulation during pregnancy through placenta transfer. Thus, plutonium may not represent a radiologic risk for the radiosensitive tissues of the fetus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pounamu (NZ jade), or nephrite, is a protected mineral in its natural form following thetransfer of ownership back to Ngai Tahu under the Ngai Tahu (Pounamu Vesting) Act 1997.Any theft of nephrite is prosecutable under the Crimes Act 1961. Scientific evidence isessential in cases where origin is disputed. A robust method for discrimination of thismaterial through the use of elemental analysis and compositional data analysis is required.Initial studies have characterised the variability within a given nephrite source. This hasincluded investigation of both in situ outcrops and alluvial material. Methods for thediscrimination of two geographically close nephrite sources are being developed.Key Words: forensic, jade, nephrite, laser ablation, inductively coupled plasma massspectrometry, multivariate analysis, elemental analysis, compositional data analysis

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The amounts of macro (P, K, Ca and Mg) and micronutrients (Cu and Zn) extracted with the Mehlich-1 (M1) solution, by the 1.0 mol L-1 KCl (KCl) and with the 0.1 mol L-1 HCl (HCl) for representative soil types of the Rio Grande do Sul state (Brazil) were compared with those extracted with the Mehlich-1 solution determined with the inductively coupled plasma optical emission spectroscopy (ICP). The amounts of nutrients extracted by the different methods showed high correlation coefficients. On average, the Mehlich-1 solution extracted similar amounts of P, determined with colorimetric and ICP methods, and, K determined with emission and ICP. The amounts of Ca and Mg extracted with the Mehlich-1 solution, determined by ICP, were similar to those extracted with the KCl solution determined by the atomic absorption spectrophotometry. The amounts of Cu and Zn extracted with the Mehlich-1 solution, determined by the ICP, were higher than those extracted with the 0.1 mol L-1 HCl determined by the atomic absorption spectrophotometry. The results indicate that the Mehlich-1 solution and ICP can be used for simultaneous multielement extraction and determination for Southern Brazilian soils. However, a conversion factor for values interpretation is needed. The use of the conversion factor to determine the K availability index in soils is adequate and does not affect the K recommendations for crops in southern Brazilian soils.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The variety of soils in the State of Acre is wide and their chemical profiles are still not fully understood. The nature of the material of origin of these soils is indicated by the high aluminium (Al) content, commonly associated with high calcium (Ca) and magnesium (Mg) contents. The study objective was to use different methods to quantify Al in soils from toposequences formed from material of a sedimentary nature originating from the Solimões Formation, in Acre, Brazil. Trenches were opened at three distinct points in the landscape: shoulder, backslope and footslope positions. Soil samples were collected for physical, chemical, mineralogical analyses. The Al content was quantified using different methods. High Al contents were found in most of these horizons, associated with high Ca and Mg levels, representing the predominant cations in the sum of exchangeable bases. The mineralogy indicates that the soils are still in a low weathering phase, with the presence of significant quantities of 2:1 minerals. Similar Al contents were determined by the methods of NaOH titration, xylenol orange spectrometry and inductively coupled plasma optical emission spectrometry. However, no consistent data were obtained by the pyrocatechol violet method. Extraction with KCl overestimated the exchangeable Al content due to its ability to extract the non-exchangeable Al present in the smectite interlayers. It was observed that high Al contents are related to the instability of the hydroxyl-Al smectite interlayers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anthropogenic emissions of metals from sources such as smelters are an international problem, but there is limited published information on emissions from Australian smelters. The objective of this study was to investigate the regional distribution of heavy metals in soils in the vicinity of the industrial complex of Port Kembla, NSW, Australia, which comprises a copper smelter, steelworks and associated industries. Soil samples (n=25) were collected at the depths of 0-5 and 5-20 cm, air dried and sieved to < 2 mm. Aqua regia extractable amounts of As, Cr, Cu, Ph and Zn were analysed by inductively coupled plasma mass spectrometry (lCP-MS) and inductively coupled plasma atomic emission spectrometry (ICP-AES). Outliers were identified from background levels by statistical methods. Mean background levels at a depth of 0-5 cm were estimated at 3.2 mg/kg As, 12 mg/kg Cr, 49 mg/kg Cu, 20 mg/kg Ph and 42 mg/kg Zn. Outliers for elevated As and Cu values were mainly present within 4 km from the Port Kembla industrial complex, but high Ph at two sites and high Zn concentrations were found at six sites up to 23 km from Port Kembla. Chromium concentrations were not anomalous close to the industrial complex. There was no significant difference of metal concentrations at depths of 0-5 and 5-20 cm, except for Ph and Zn. Copper and As concentrations in the soils are probably related to the concentrations in the parent rock. From this investigation, the extent of the contamination emanating from the Port Kembla industrial complex is limited to 1-13 km, but most likely <4 km, depending on the element; the contamination at the greater distance may not originate from the industrial complex. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

U-Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U-Pb ages below 1 billion years (1 Ga), Pb-206/U-238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U-Pb zircon dating by sensitive sector field ICPMS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the study is to evaluate the differences of protein binding of NAMI-A, a new ruthenium drug endowed with selective antimetastatic properties, and of cisplatin and to ascertain the possibility to use two drugs based on heavy metals in combination to treat solid tumour metastases. For this purpose, we have developed a technique that allows the proteins, to which metal drugs bind, to be identified from real protein mixtures. Following incubation with the drugs, the bands containing platinum and/or ruthenium are separated by native PAGE, SDS-PAGE and 2D gel electrophoresis, and identified using laser ablation inductively coupled plasma mass spectrometry. Both drugs interact with essentially the same proteins which, characterised by proteomics, are human serum albumin precursor, macroglobulin alpha 2 and human serotransferrin precursor. The interactions of NAMI-A are largely reversible whereas cisplatin forms stronger interactions that are less reversible. These data correlate well with the MCa mammary carcinoma model on which full doses of NAMI-A combined with cisplatin show additive effects as compared to each treatment taken alone, independently of whether NAMI-A precedes or follows cisplatin. Furthermore, the implication from this study is that the significantly lower toxicity of NAMI-A, compared to cisplatin, could be a consequence of differences in the mode of binding to plasma proteins, involving weaker interactions compared to cisplatin.