997 resultados para implant stress


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When a cylinder is connected to an abutment it is expected that abutment and cylinder will be subjected to compression forces throughout their periphery because of the clamping force exerted by the screw. The deformation resultant of this compression should be measurable and uniform along the periphery of the abutment. Considering that multiple retainers connected to each other can affect the fit of a framework, as well as the use of different alloys, it is expected that the abutments will present different levels of deformation as a result of framework connection. The aim of this study was to evaluate the deformation of implant abutments after frameworks, cast either in cobalt-chromium (CoCr) or silver-palladium (AgPd) alloys, were connected. Samples (n = 5) simulating a typical mandibular cantilevered implant-supported prosthesis framework were fabricated in cobalt-chromium and silver-palladium alloys and screwed onto standard abutments positioned on a master-cast containing 5 implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation as the retention screws were tightened. A combination of compressive and tensile forces was observed on the abutments for both CoCr and AgPd frameworks. There was no evidence of significant differences in median abutment deformation levels for 9 of the 10 abutment aspects. Visually well-fit frameworks do not necessarily transmit load uniformly to abutments. The use of CoCr alloy for implant-supported prostheses frameworks may be as clinically acceptable as AgPd alloy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Because the mechanical behavior of the implant-abutment system is critical for the longevity of implant-supported reconstructions, this study evaluated the fatigue reliability of different implant-abutment systems used as single-unit crowns and their failure modes. Methods and Materials: Sixty-three Ti-6Al-4V implants were divided in 3 groups: Replace Select (RS); IC-IMP Osseotite; and Unitite were restored with their respective abutments. Anatomically correct central incisor metal crowns were cemented and subjected to separate single load to failure tests and step-stress accelerated life testing (n = 18). A master Weibull curve and reliability for a mission of 50,000 cycles at 200 N were calculated. Polarized-light and scanning electron microscopes were used for failure analyses. Results: The load at failure mean values during step-stress accelerated life testing were 348.14 N for RS, 324.07 N for Osseotite, and 321.29 N for the Unitite systems. No differences in reliability levels were detected between systems, and only the RS system mechanical failures were shown to be accelerated by damage accumulation. Failure modes differed between systems. Conclusions: The 3 evaluated systems did not present significantly different reliability; however, failure modes were different. (Implant Dent 2012;21:67-71)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To explore the biomechanical effects of the different implantation bone levels of Morse taper implants, employing a finite element analysis (FEA). METHODS: Dental implants (TitamaxCM) with 4x13 mm and 4x11 mm, and their respective abutments with 3.5 mm height, simulating a screwed premolar metal-ceramic crown, had their design performed using the software AnsysWorkbench 10.0. They were positioned in bone blocks, covered by 2.5 mm thickness of mucosa. The cortical bone was designed with 1.5 mm thickness and the trabecular bone completed the bone block. Four groups were formed: group 11CBL (11 mm implant length on cortical bone level), group 11TBL (11 mm implant length on trabecular bone level), group 13CBL (13mm implant length on cortical bone level) and group 13TBL (13 mm implant length on trabecular bone level). Oblique 200 N loads were applied. Von Mises equivalent stresses in cortical and trabecular bones were evaluated with the same design program. RESULTS: The results were shown qualitatively and quantitatively by standard scales for each type of bone. By the results obtained, it can be suggested that positioning the implant completely in trabecular bone brings harm with respect to the generated stresses. Its implantation in the cortical bone has advantages with respect to better anchoring and locking, reflecting a better dissipation of the stresses along the implant/bone interfaces. In addition, the search for anchoring the implant in its apical region in cortical bone is of great value to improve stabilization and consequently better stress distribution. CONCLUSIONS: The implant position slightly below the bone in relation to the bone crest brings advantages as the best long-term predictability with respect to the expected neck bone loss.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aseptic loosening of metal implants is mainly attributed to the formation of metal degradation products. These include particulate debris and corrosion products, such as metal ions (anodic half-reaction) and ROS (cathodic half-reaction). While numerous clinical studies describe various adverse effects of metal degradation products, detailed knowledge of metal-induced cellular reactions, which might be important for possible therapeutic intervention, is not comprehensive. Since endothelial cells are involved in inflammation and angiogenesis, two processes which are critical for wound healing and integration of metal implants, the effects of different metal alloys and their degradation products on these cells were investigated. Endothelial cells on Ti6Al4V alloy showed signs of oxidative stress, which was similar to the response of endothelial cells to cathodic partial reaction of corrosion induced directly on Ti6Al4V surfaces. Furthermore, oxidative stress on Ti6Al4V alloy reduced the pro-inflammatory stimulation of endothelial cells by TNF-α and LPS. Oxidative stress and other stress-related responses were observed in endothelial cells in contact with Co28Cr6Mo alloy. Importantly, these features could be reduced by coating Co28Cr6Mo with a TiO2 layer, thus favouring the use of such surface modification in the development of medical devices for orthopaedic surgery. The reaction of endothelial cells to Co28Cr6Mo alloy was partially similar to the effects exerted by Co2+, which is known to be released from metal implants. Co2+ also induced ROS formation and DNA damage in endothelial cells. This correlated with p53 and p21 up-regulation, indicating the possibility of cell cycle arrest. Since CoCl2 is used as an hypoxia-mimicking agent, HIF-1α-dependence of cellular responses to Co2+ was studied in comparison to anoxia-induced effects. Although important HIF-1α-dependent genes were identified, a more detailed analysis of microarray data will be required to provide additional information about the mechanisms of Co2+ action. All these reactions of endothelial cells to metal degradation products might play their role in the complex processes taking place in the body following metal device implantation. In the worst case this can lead to aseptic loosening of the implant and requirement for revision surgery. Knowledge of molecular mechanisms of metal-induced responses will hopefully provide the possibility to interfere with undesirable processes at the implant/tissue interface, thus extending the life-time of the implant and the overall success of metal implant applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Distraction-based spinal growth modulation by growing rods or vertical expandable prosthetic titanium ribs (VEPTRs) is the mainstay of instrumented operative strategies to correct early onset spinal deformities. In order to objectify the benefits, it has become common sense to measure the gain in spine height by assessing T1-S1 distance on anteroposterior (AP) radiographs. However, by ignoring growth changes on vertebral levels and by limiting measurement to one plane, valuable data is missed regarding the three-dimensional (3D) effects of growth modulation. This information might be interesting when it comes to final fusion or, even more so, when the protective growing implants are removed and the spine re-exposed to physiologic forces at the end of growth. METHODS The goal of this retrospective radiographic study was to assess the growth modulating impact of year-long, distraction-based VEPTR treatment on the morphology of single vertebral bodies. We digitally measured lumbar vertebral body height (VBH) and upper endplate depth (VBD) at the time of the index procedure and at follow-up in nine patients with rib-to-ileum constructs (G1) spanning an anatomically normal lumbar spine. Nine patients with congenital thoracic scoliosis and VEPTR rib-to-rib constructs, but uninstrumented lumbar spines, served as controls (G2). All had undergone more than eight half-yearly VEPTR expansions. A Wilcoxon signed-rank test was used for statistical comparison of initial and follow-up VBH, VBD and height/depth (H/D) ratio (significance level 0.05). RESULTS The average age was 7.1 years (G1) and 5.2 year (G2, p > 0.05) at initial surgery; the average overall follow-up time was 5.5 years (p = 1). In both groups, VBH increased significantly without a significant intergroup difference. Group 1 did not show significant growth in depth, whereas VBD increased significantly in the control group. As a consequence, the H/D ratio increased significantly in group 1 whereas it remained unchanged in group 2. The growth rate for height in mm/year was 1.4 (group 1) and 1.1 (group 2, p = 0.45), and for depth, it was -0.3 and 1.1 (p < 0.05), respectively. CONCLUSIONS VEPTR growth modulating treatment alters the geometry of vertebral bodies by increasing the H/D ratio. We hypothesize that the implant-related deprivation from axial loads (stress-shielding) impairs anteroposterior growth. The biomechanical consequence of such slender vertebrae when exposed to unprotected loads in case of definitive VEPTR removal at the end of growth is uncertain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to evaluate different management strategies to optimize rabbit production under chronic heat stress. To achieve it, three trials were conducted. In the first trial, to find the optimal cage density in tropical very dry forest condition, were measured growth performance, mortality rate, injured animals and carcass performance over an initial population of 300 cross-breed rabbits of New Zealand, California, Butterfly, Dutch and Satin, weaned at 30 days (535 ± 8 g, standard error). Treatments evaluated were: 6, 12, 18 and 24 rabbits/m2 (3, 6, 9 and 12 rabbits/cage, respectively, each cage of 0.5 m2). The maximal temperature-humidity index indicated a severe heat stress from weaning to 2.2 kg body weight (experimental time). At the end of experimental period 10, 20, 30 and 30 rabbits from the treatments of 6, 12, 18 and 24 rabbits/m2, respectively, were slaughtered and carcass performance recorded. Average daily gain and feed intake decreased by 0.31 ± 0.070 and 1.20 ± 0.25 g, respectively, per each unit that the density increased at the beginning of the experiment (P = 0.001). It increased the length of the fattening period by 0.91 ± 0.16 d (P = 0.001) per each unit of increment of density. However, rabbit production (kg/m2) increased linear and quadratically with the density (P < 0.008). Animals housed at the highest density compared to the lower one tended to show a higher incidence of ringworm (68.9 vs 39.4%; P = 0.075), injured animals (16.8 vs 3.03%; P = 0.12) and mortality (20.5 vs 9.63%; P = 0.043). The proportion of scapular fat (P = 0.042) increased linearly with increasing levels of density. Increasing density reduced linearly dorsal length (P = 0.001), and reduced linear and quadratically drip loss percentage (P = 0.097 and 0.018, respectively). In the second trial, 46 nulliparous rabbit does (23 clipped and 23 unclipped) with a BW of 3.67 ± 0.05 kg (s.e.) were used to evaluate heat stress and circadian rhythms comparing unclipped and clipped rabbit does, and to study if a more extensive breeding system increase litters performance at weaning without impairing rabbit doe performance,. Rectal temperature, feed and water 4 intake were recorded for 24 h. Rabbit does were mated 7 d after circadian measurements, and randomly assigned to two breeding systems. Control (C): mated at 14 d after parturition + litter weaned at 35 d of age. Extensive (E): mate at 21 after parturition + litter weaned at 42 d of age. The first three cycles were evaluated concerning to rabbit doe and litter performance. Two hundred twenty eight weaned rabbits, were divided into two cage sizes: 0.5 and 0.25 m2 with same density (16 rabbit/m2) and growing performance was recorded. Farm and rectal temperatures were minimal and feed and water intake maximal during the night (P < 0.001). Unclipped rabbit does showed higher rectal temperature (P = 0.045) and lower feed intake respect to clipped does (P = 0.019) which suggest a lower heat stress in the latter. Kits weaned per litter was reduced by 33% (P=0.038) in C group. This reduction was more important in the 2nd and 3rd cycles compared to the first (P ≤ 0.054). Rabbit doe feed efficiency tended to decrease in E respect C group (P = 0.093), whereas it was impaired from the first to the third cycle by 48% (P = 0.014). Growing rabbits from the E group were heavier at weaning (by 38%. P < 0.001), showed a higher feed intake (+7.4%) and lower feed efficiency (-8.4%) throughout the fattening period (P ≤ 0.056) respect to C group. Cage size had minor influence in growing performance. In the third trial, forty five non pregnant and non lactating rabbit does (21 nulliparous and 24 multiparous) were assigned randomly to farm water and to potable water to study if a water quality improvement can affect positively rabbit doe response to heat stress during pregnancy and lactation. A transponder was implanted in each animal to record subcutaneous temperature at 07:30 and 14:30 h. Experimental period extended from pregnancy (with no lactation) to the next lactation (until day 28). Body temperature and milk production were recorded daily, and body condition, feed and water intake weekly. Water quality did not affect any trait (P ≥ 0.15). Pregnant rabbit does were classified as does that weaned (W: 47%), not weaned (NW: 44%) or those pregnant that did not deliver (NB: 9%). Body temperature and feed intake decreased during pregnancy (P ≤ 0.031), but water intake remained constant. In this period body temperature decreased with metabolic weight (P ≤ 0.009). In W and NW does, 5 from mating to birth energy and protein balance impaired (P≤0.011). Body temperature of W does tended to be the lowest (P ≤ 0.090). Pregnancy length and total number of kits born tended to be longer and higher in NW than in W does (P = 0.10 and 0.053, respectively). Kit mortality at birth and from birth to 14 d of lactation was high, being worse for NW than for W does (97 vs. 40%; P<0.001). Body temperature during lactation was maximal at day 12, and milk production increased it (P ≤ 0.025). . In conclusion, in our heat stress conditions densities higher than 18 rabbits/m2 (34 kg/m2) at the end of fattening, are not recommended despite cage size, gestation and lactation productivity impaired not only when lactation is extended and along successive reproductive cycles but also due to a reduced embryo/kit survival and finally water quality improvement did not attenuate negative effect of heat stress. RESUMEN El propósito de éste trabajo fue evaluar diferentes estrategias de manejo para optimizar la producción de conejos bajo estrés térmico. Para lo cual se desarrollaron tres experimentos. En el primer experimento, para encontrar el número óptimo de gazapos por m2 de jaula durante el cebo en condiciones de bosque muy seco tropical, se estudiaron los rendimientos durante el cebo, mortalidad, animales lesionados y rendimiento de la canal sobre una población inicial de 300 conejos mestizos de Nueva Zelanda, California, Mariposa, Holandés y Satin, destetados a los 30 días de edad (535 ± 8g, error estándar). Los tratamientos evaluados fueron: 6, 12, 18 y 24 conejos/m2 (3, 6, 9 y 12 conejos/jaula, respectivamente, en jaulas de 0.5 m2). Durante el período experimental (destete a 2.2 kg de peso vivo), se observaron valores de THI correspondientes con un estrés térmico severo (THI max. De 31 a 35). Al final del período experimental, 10, 20, 30, y 30 conejos de los tratamientos con densidades de 6, 12, 18 y 24 conejos/m2, respectivamente, fueron sacrificados y su canal fue valorada. El promedio de la ganancia diaria y el consumo de alimento disminuyeron en 0.31 ± 0.070 y 1.20 ± 0.25 g, respectivamente, por cada unidad de incremento en la densidad al inicio del experimento (P=0.001). Esto alargó el período de engorde en 0.91 ± 0.16 d (P=0.001) por cada unidad de incremento de la densidad. Sin embargo, la producción de conejos (kg/m2) aumentó lineal y cuadráticamente con la densidad (P<0.008). Los animales alojados en las mayores densidades en comparación con el resto tendieron a mostrar una mayore incidencia de tiña (68.9 vs 39.4%; P=0.075), de cantidad de animales heridos (16.8 vs 3.03%; P=0.12), así como de mortalidad (20.5 vs 9.63%; P=0.043). El aumento en la densidad aumentó linealmente la proporción de grasa escapular (P=0.042) y redujo linealmente la longitud dorsal (P=0.001), y lineal y cuadráticamente el porcentaje de pérdida por goteo (P=0.018). En el segundo experimento, 46 conejas nulliparas (23 rasuradas y 23 no rasuradas) con un peso vivo de 3.67 ± 0.05 kg (e.e.) fueron usadas para evaluar el estrés 8 térmico y los ritmos circadianos comparando conejas rasuradas o no, y estudiar si un sistema de crianza más extensivo mejora el desempeño de la camada al destete sin perjudicar la productividad de la coneja. Durante 24 h se midió la temperatura rectal, consumo de alimento y de agua. Las conejas fueron montadas 7 días después, y distribuidas en dos sistemas de crianza. El control (C): monta a 14 días posparto y destete a 35 d de edad. El extensivo (E): monta a 21 días posparto y destete a 42 d de edad. Se controló la productividad de la coneja y la camada durante los tres primeros ciclos. Doscientos veintiocho gazapos fueron distribuidos en dos tamaños de jaulas (0.5 y 0.25 m2) con la misma densidad (16 conejos/m2) y se controlaron sus rendimientos productivos. Durante la noche se observaron los valores mínimos para la temperatura ambiental y rectal, y los máximos para consumo de alimento y agua (P< 0.001). Las conejas no rasuradas mostraron mayor temperatura rectal (P=0.045) y menores valores de consumo de alimento con respecto a las conejas rasuradas (P=0.019), lo que sugiere un menor estrés térmico en las últimas. El número de gazapos destetados por camada se redujo en 33% (P=0.038) en el grupo C. Este comportamiento se acentuó en el 2do y 3er ciclo en comparación con el primero (P≤0.054). La eficiencia alimenticia de las conejas tendió a disminuir en el grupo E con respecto al grupo C (P=0.093), dicha tendencia se acentúa del primer al tercer ciclo en un 48% (P=0.014). Los gazapos en fase de crecimiento provenientes del grupo E fueron más pesados al momento del destete (en 38% P<0.001), mostrando un mayor consumo de alimento (+7.4%) y menor eficiencia alimenticia (-8.4%) a lo largo del engorde (P≤0.056) con respecto al grupo C. El tamaño de la jaula tuvo una mínima influencia en el comportamiento durante el crecimiento de éstos gazapos. En el tercer experimento, cuarenta y cinco conejas no gestantes ni lactantes (21 nulíparas y 24 multíparas) se les asignó al azar agua dos tipos de agua: común de la granja y agua potable, con el fin de estudiar si una mejora en la calidad del agua puede afectar positivamente la respuesta de la coneja al estrés térmico durante la gestación y la lactancia. Se les implantó un transponder para registrar la temperatura subcutánea a las 7:30 y a las 14:30 h. El período experimental se extendió desde la gestación (sin 9 lactancia) hasta la lactanción consecutiva (hasta los 28 días). La temperatura corporal y la producción de leche se controlaron diariamente, y la condición corporal, consumo de agua y alimento, semanalmente. La calidad del agua no afectó a ninguna variable (P≥0.15). Las conejas preñadas fueron clasificadas como conejas que destetaron (W: 47%), que no destetaron (NW:44%) o aquellas que no parieron (NB: 9%). La temperatura corporal y consumo de alimento disminuyeron durante la gestación (P≤0.031), mientras que el consumo de agua se mantuvo constante. La temperatura corporal descendió con el peso metabólico durante la gestación (P≤0.009). El balance de energía y proteína disminuyó desde la monta al parto para las conejas W y NW (P≤0.011). Durante la gestación la temperatura corporal tendió a ser menor en las conejas W (P≤0.090). La longitud de la gestación y el número total de gazapos nacidos tendieron a ser mayores en conejas NW que en conejas W (P=0.10 y 0.053, respectivamente). La mortalidad de los gazapos al parto y del parto a los 14 días de lactancia fue alta, siendo peor para las conejas NW que para las W (97 vs 40%; P<0.001). Durante la lactancia la temperatura corporal alcanzó su valor máximo para el día 12, y la producción de leche indujo un incremento en la misma (P≤0.025). En conclusión, en nuestras condiciones de estrés térmico y sin importar el tamaño de la jaula, no se recomiendan densidades mayores a 18 conejos/m2 (34 kg/m2) al final del engorde. La productividad de la gestación y la lactancia disminuyen cuando la lactancia es mayor y se suceden varios ciclos reproductivos seguidos. Esto se debe al efecto negativo del estrés térmico sobre la vitalidad y supervivencia del embrión/gazapo. La mejora de la calidad del agua atenuó el efecto negativo del estrés térmico. Las conejas más productoras parece que son aquéllas que consiguen manejar mejor el estrés térmico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fixation failure of glenoid components is the main cause of unsuccessful total shoulder arthroplasties. The characteristics of these failures are still not well understood, hence, attempts at improving the implant fixation are somewhat blind and the failure rate remains high. This lack of understanding is largely due to the fundamental problem that direct observations of failure are impossible as the fixation is inherently embedded within the bone. Twenty custom made implants, reflecting various common fixation designs, and a specimen set-up was prepared to enable direct observation of failure when the specimens were exposed to cyclic superior loads during laboratory experiments. Finite element analyses of the laboratory tests were also carried out to explain the observed failure scenarios. All implants, irrespective of the particular fixation design, failed at the implant-cement interface and failure initiated at the inferior part of the component fixation. Finite element analyses indicated that this failure scenario was caused by a weak and brittle implant-cement interface and tensile stresses in the inferior region possibly worsened by a stress raiser effect at the inferior rim. The results of this study indicate that glenoid failure can be delayed or prevented by improving the implant/cement interface strength. Also any design features that reduce the geometrical stress raiser and the inferior tensile stresses in general should delay implant loosening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growth rods are commonly used for the treatment of scoliosis in the immature spine. Many variations have been proposed but breakage of implants is a common problem. Growth rod insertion commonly involves large exposures at initial insertion followed by multiple smaller procedures for lengthening. We present our early experiences using a percutaneous technique of insertion of a new titanium mobile bearing implant (Medtronic Inc). The implant allows some rotatory motion in the middle of the construct thus reducing construct stresses and thus possibly reducing rod breakage risk. Based on this small initial series with 12 months follow-up, percutaneous insertion of growth rods using the new implant is a safe and reliable technique although the infection rate in our sample was of note. This may be related to the titanium wear and inflammation seen in the soft tissues at time of operation and visualised on histology. No implants have required removal due to infection, and all infections were treated with debridement at next lengthening and suppressive antibiotics. Propionibacterium is one of the commonest infections seen with spinal implants and sometimes does not respond to simple antibiotic suppression. The technique allows preservation of the soft tissues until definitive fusion is needed and may lead to a decrease in hospital stay. The implant is low profile and seems to offer advantages over other systems on the market. Further follow up is needed to look at longer term outcomes with this new implant type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is unclear which theoretical dimension of psychological stress affects health status. We hypothesized that both distress and coping mediate the relationship between socio-economic position and tooth loss. Cross-sectional data from 2915 middle-aged adults evaluated retention of < 20 teeth, behaviors, psychological stress, and sociodemographic characteristics. Principal components analysis of the Perceived Stress Scale (PSS) extracted 'distress' (a = 0.85) and 'coping' (a =0.83) factors, consistent with theory. Hierarchical entry of explanatory variables into age- and sex-adjusted logistic regression models estimated odds ratios (OR) and 95% confidence intervals [95% CI] for retention of < 20 teeth. Analysis of the separate contributions of distress and coping revealed a significant main effect of coping (OR = 0.7 [95% CI = 0.7-0.8]), but no effect for distress (OR = 1.0 [95% CI = 0.9-1.1]) or for the interaction of coping and distress. Behavior and psychological stress only modestly attenuated socio-economic inequality in retention of < 20 teeth, providing evidence to support a mediating role of coping.