988 resultados para hearing aids


Relevância:

60.00% 60.00%

Publicador:

Resumo:

CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this paper the hardware implementation of an inner hair cell model is presented. Main features of the design are the use of Meddis’ transduction structure and the methodology for Design with Reusability. Which allows future migration to new hardware and design refinements for speech processing and custom-made hearing aids

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Para a adequada implantação de um Programa de Concessão, Adaptação e Acompanhamento do Sistema FM em estudantes com deficiência auditiva nas escolas brasileiras é necessário um trabalho intersetorial, caracterizado por uma cuidadosa articulação entre os Sistemas Educacional e de Saúde. As ações em rede integrarão os diferentes níveis de atenção da pessoa com deficiência auditiva, conforme a nova política interministerial Viver Sem Limites. O objetivo deste estudo foi desenvolver e analisar a eficácia de um ambiente virtual de transmissão de informações sobre Sistema FM para profissionais utilizando a Teleducação Interativa. Devido à distribuição geográfica dos profissionais que atuam com a adaptação do Sistema FM em alunos usuários de Sistema FM foi proposto o acesso aos módulos à distância (Teleducação) via internet por meio do Portal Sistema FM disponibilizado em endereço eletrônico http://portalsistemafm.fob.usp.br/. O portal é composto por 7 módulos, sendo que todos os materiais foram transformados em infográficos, com possibilidade de download. Realizaram o cadastro no Portal Sistema FM 50 profissionais que atuam em Serviços de Saúde Auditiva credenciados pelo SUS, sendo que 31 fonoaudiólogos avaliaram o Portal Sistema FM. Para a avaliação do programa de capacitação foram propostos os instrumentos Ficha de Pesquisa Motivacional, Escala de Autoavaliação de Impacto do Treinamento no trabalho - medida de amplitude e um Questionário sobre o conteúdo teórico, todos contidos em um módulo do Portal. Os fonoaudiólogos, respondendo a Ficha de Pesquisa Motivacional, consideraram o Portal Sistema FM com expectativa para o sucesso. A Escala de Impacto no Trabalho demonstrou que o acesso aos módulos do Portal Sistema FM gerou um impacto no trabalho dos participantes, quando aplicado após o primeiro acesso e dois meses depois, porém não foi indicada diferença estatisticamente significante quando comparadas. No questionário sobre o conteúdo teórico os participantes obtiveram uma média de 79,03% de acerto. O Portal Sistema FM foi criado e encontra-se disponível no endereço eletrônico http://portalsistemafm.fob.usp.br/, sendo avaliado como um portal impressionante quanto à motivação dos participantes. O acesso aos módulos trouxe impacto no trabalho dos profissionais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A demanda crescente de usuários de implante coclear (IC) e a distribuição irregular de profissionais especializados no país, tornam necessário o deslocamento de pacientes por longas distâncias para os atendimentos, com consequente aumento dos custos diretos e indiretos do tratamento. A teleconsulta pode ser vista como uma alternativa em potencial para o acesso desta população a estes serviços. O presente ensaio clínico, randomizado, controlado, avaliou a eficácia da teleconsulta síncrona na programação dos sistemas de IC em usuários acompanhados em um Programa de Implante Coclear credenciado pelo Sistema Único de Saúde. Participaram do estudo 79 indivíduos com idades entre nove e 68 anos (média de 21,6), 41 do sexo masculino e 38 do sexo feminino, usuários de IC por um período de 0,58 a 24,75 anos. Estes indivíduos foram divididos em dois grupos, de acordo com o modo de programação do IC: controle (n=40), que realizou o procedimento face a face e experimental (n=39) que realizou a teleconsulta síncrona. Treze fonoaudiólogos sem experiência na programação do dispositivo atuaram como facilitadores das teleconsultas. Os procedimentos de programação do IC englobaram a telemetria de impedância, definição dos níveis de estimulação elétrica, varredura e balanceamento dos eletrodos e ajuste fino da programação. Como medidas de avaliação de resultados foram utilizados o tempo dispendido na consulta, a audiometria em campo livre, o percentual de reconhecimento de sentenças no silêncio e no ruído, o limiar de reconhecimento de sentenças no silêncio e ruído (HINT-Brasil), a avaliação da satisfação com a consulta (escala MISS-21) e de aspectos pertinentes à teleconsulta. Os facilitadores responderam as questões abertas referentes à suas impressões dos atendimentos. Os dados foram analisados por meio de estatística inferencial (testes t de Student, Wilcoxon, Mann-Whitney e correlação de Spearman). Os resultados mostraram que após a programação do IC, em média, os participantes apresentaram limiares audiométricos abaixo de 30 dB NA. O reconhecimento da fala pós atendimento, respectivamente para os grupos experimental e controle, foram de 81,3% e 83,8% (silêncio) e 57,9% e 58,1% (ruído). No HINT-Brasil os resultados foram, respectivamente, para os grupos experimental e controle 61,4 dB NA e 61,8 dB NA (silêncio) e relação S/R de 9,5 dB NA e 10,4 dB NA (ruído). Os participantes estiveram satisfeitos com a consulta. Não houve diferença estatisticamente significativa entre os grupos em nenhuma das medidas de resultado. Todos os participantes relataram que teleconsulta pode ser vista como uma alternativa viável ao atendimento face a face e sua aplicação clínica facilitaria a rotina de pacientes usuários de IC. Os facilitadores destacaram a sua importância para o aprendizado e como ferramenta de formação continuada. A teleconsulta síncrona foi eficaz na programação dos sistemas de IC e amplamente aceita pelos usuários e profissionais.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A perda auditiva unilateral (PAUn) é caracterizada pela diminuição da audição em apenas uma orelha. Indivíduos com este tipo de perda auditiva podem apresentar comprometimento nas habilidades auditivas de localização sonora, processamento temporal, ordenação e resolução temporal. O objetivo deste estudo foi verificar as habilidades auditivas de ordenação temporal, resolução temporal e localização sonora, antes e após a adaptação do aparelho de amplificação sonora individual (AASI). Foram avaliados 22 indivíduos, com idades entre 18 e 60 anos, com diagnóstico de PAUn sensorioneural ou mista, de graus leve a severo. O estudo foi dividido em duas etapas: a pré e a pós-adaptação de AASI. Em ambas as etapas, os indivíduos foram submetidos a uma anamnese, aplicação do Questionário de Habilidade Auditiva da Localização da fonte sonora, avaliação simplificada do processamento auditivo (ASPA) e Random Gap Detection Test (RGDT). O presente estudo encontrou diferença estatisticamente significante na avaliação da ASPA, exceto no teste de memória para sons não verbais em sequência (TMSnV), no RGDT e no Questionário de Habilidade Auditiva da Localização Sonora. A conclusão do estudo foi que com o uso efetivo do AASI, indivíduos com PAUn apresentaram melhora nas habilidades auditivas de localização sonora, ordenação e resolução temporal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: O implante coclear (IC) amplamente aceito como forma de intervenção e (re) habilitação nas perdas auditivas severas e profundas nas diversas faixas etárias. Contudo observa-se no usuário do IC unilateral queixas como localização e compreensão sonora em meio ao ruído, gerado pelo padrão anormal de estimulação sensorial. A fim de fornecer os benefícios da audição binaural, é preconizado a estimulação bilateral, seja por meio do IC bilateral ou com a adaptação de um aparelho de amplificação sonora individual (AASI) contralateralmente ao IC. Esta última condição é referida como estimulação bimodal, quando temos, concomitantemente dois modos de estimulação: Elétrica (IC) e acústica (AASI). Não há dados suficientes na literatura voltados à população infantil que esclareça ou demonstre o desenvolvimento do córtex auditivo na audição bimodal. Ressalta-se que não foram encontrados estudos em crianças. Objetivo: Caracterizar o PEAC complexo P1, N1 P2 em usuários da estimulação bimodal e verificar se há correlação com testes de percepção de fala. Metodologia: Estudo descritivo de séries de casos, com a realização do PEAC em cinco crianças usuárias da estimulação bimodal, a partir da metodologia proposta por Ventura (2008) utilizando o sistema Smart EP USB Jr da Intelligent Hearing Systems. Foi utilizado o som de fala /da/, apresentado em campo livre. O exame será realizado em três situações: Somente IC, IC e AASI e somente AASI. A análise dos dados dos potenciais corticais foi realizada após a marcação da presença ou ausência dos componentes do complexo P1-N1-P2 por dois juízes com experiência em potenciais evocados. Resultados: Foi obtida a captação do PEAC em todas as crianças em todas as situações de teste, além do que foi possível observar a correlação destes com os testes de percepção auditiva da fala. Foi possível verificar que o registro dos PEAC é um procedimento viável para a avaliação da criança com estimulação bimodal, porém, ainda não há dados suficientes quanto a utilização deste para a avaliação e indicação do IC bilateral.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Successful hearing aid fitting occurs when the person fitted wears the aid/s on a regular basis and reports benefit when the aid/s is used. A significant number of people fitted with unilateral or bilateral hearing aids for the first time do not continue to use one or both aids in the long term. In this paper, factors consistently found in previous research to be associated with unsuccessful fitting are explored; in particular, the negative attitudes of some clients towards hearing aids, their lack of motivation for seeking help, inability to identify goals for rehabilitation, and problems with the management of the devices. It is argued here that success in hearing aid fitting involves the same dynamics as found with other assistive technologies (e.g., wheelchairs, walking frames), and is dependent on a match between the characteristics of a prospective user, the technology itself, and the environments of use (Scherer, 2002). It is recommended that for clients who identify concerns about hearing aids, or who are unsure about when they would use them, and/or are likely to have problems with aid management, only one aid be fitted in the first instance, if hearing aid fitting is to proceed at all. Rehabilitation approaches to promote successful fitting are discussed in light of results obtained from a survey of clients who experienced both successful and unsuccessful aid fitting.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Screening measures of cognitive status are traditionally administered face to face. In survey research such screening mcasurcs, while desirable, must he administered by other means. As part of pilot survey research on a New Zealand war veteran population with some degree of hearing impairment, a face-to-face administration of the Mini-Mental State Examination (MMSE; Folstein, Folstein and McHugh, 1975) and a telephoneadministration of the Telephonc Interview for Cognitive Status (TICS; Brandt, Spencer and Folstein. 1988) were compared. Brandt ('/ u/. (1988) reported a very strong linear relationship between scores on the MMSE and the TICS (r=0.94, p < .0001) in an Alzheimer patient population with a mcan MMSE score of 12.06 (6.78). For a sample of 44 mildly to moderately hearing impaired veterans, with a mean MMSE score of 25.52 (2.16) and a mean TICS score of 32.52(5.43), the correlation between the instruments was .39. When veterans who wore hearing aids during the telephone interview ( N = 2 2 ) wcrc separated out from those who did not, the correlation rose to .54. Age was ncgatively correlated with the MMSE ( r = -0.41, / I < .01) and not significantly correlated with the TICS. Education level was unrelated to either measure. The data suggest that the wearing or non-wearing of hearing aids may contribute significantly to the reliability of the TICS. Furthermore, on non-demented populations with a less restricted range of scores. the correlation of the MMSE and TICS may he lower than previously reported.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The prevalence of hearing loss is considerably higher in individuals in residential care than in people within the community-dwelling population, and yet hearing aids and hearing services are relatively underused. Care staff have a key role in supporting access to services. Objectives: This study identifies staff perspectives on hearing loss and their views about potential hearing service improvements. Study design: A four-stage mixed methods study was used, made up of qualitative interviews, observation, a survey and a stakeholder involvement meeting. Results: The qualitative stages indicated that staff were concerned about their levels of interaction with residents. Staff considered maximizing communication as part of their professional role. The quantitative survey indicated that these views were widely held by staff, and the stakeholder stage identified the need for social support and dedicated staff training opportunities. Conclusion: Care home staff regard communication as a shared issue. Future interventions could enhance access to hearing services and provide care home staff with training in hearing loss and hearing aid management. © 2013 Informa Healthcare.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

General note: Title and date provided by Bettye Lane.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: In natural hearing, cochlear mechanical compression is dynamically adjusted via the efferent medial olivocochlear reflex (MOCR). These adjustments probably help understanding speech in noisy environments and are not available to the users of current cochlear implants (CIs). The aims of the present study are to: (1) present a binaural CI sound processing strategy inspired by the control of cochlear compression provided by the contralateral MOCR in natural hearing; and (2) assess the benefits of the new strategy for understanding speech presented in competition with steady noise with a speech-like spectrum in various spatial configurations of the speech and noise sources. DESIGN: Pairs of CI sound processors (one per ear) were constructed to mimic or not mimic the effects of the contralateral MOCR on compression. For the nonmimicking condition (standard strategy or STD), the two processors in a pair functioned similarly to standard clinical processors (i.e., with fixed back-end compression and independently of each other). When configured to mimic the effects of the MOCR (MOC strategy), the two processors communicated with each other and the amount of back-end compression in a given frequency channel of each processor in the pair decreased/increased dynamically (so that output levels dropped/increased) with increases/decreases in the output energy from the corresponding frequency channel in the contralateral processor. Speech reception thresholds in speech-shaped noise were measured for 3 bilateral CI users and 2 single-sided deaf unilateral CI users. Thresholds were compared for the STD and MOC strategies in unilateral and bilateral listening conditions and for three spatial configurations of the speech and noise sources in simulated free-field conditions: speech and noise sources colocated in front of the listener, speech on the left ear with noise in front of the listener, and speech on the left ear with noise on the right ear. In both bilateral and unilateral listening, the electrical stimulus delivered to the test ear(s) was always calculated as if the listeners were wearing bilateral processors. RESULTS: In both unilateral and bilateral listening conditions, mean speech reception thresholds were comparable with the two strategies for colocated speech and noise sources, but were at least 2 dB lower (better) with the MOC than with the STD strategy for spatially separated speech and noise sources. In unilateral listening conditions, mean thresholds improved with increasing the spatial separation between the speech and noise sources regardless of the strategy but the improvement was significantly greater with the MOC strategy. In bilateral listening conditions, thresholds improved significantly with increasing the speech-noise spatial separation only with the MOC strategy. CONCLUSIONS: The MOC strategy (1) significantly improved the intelligibility of speech presented in competition with a spatially separated noise source, both in unilateral and bilateral listening conditions; (2) produced significant spatial release from masking in bilateral listening conditions, something that did not occur with fixed compression; and (3) enhanced spatial release from masking in unilateral listening conditions. The MOC strategy as implemented here, or a modified version of it, may be usefully applied in CIs and in hearing aids.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Platform strategies reflect a firm’s technology policy towards its new product development (NPD) activities. Depending on the technological complexities embedded in the platform, certain degree of interdependence is created between the firm and its suppliers. Firms may decide to what extent the suppliers should be involved in its NPD activities. There has been an increasing interest with issues related to supplier involvement in NPD. Involving suppliers early in NPD can help firms reduce costs, reduce concept-to-customer development time, improve quality, and provide innovative technologies. However, it requires a great effort and many tradeoffs need to be considered. This paper discusses the implications of early supplier involvement in new product development, specifically regarding to sourcing decisions and NPD processes when new components are designed and incorporated into the new platform. We would like to understand to what extent the NPD collaborates with suppliers, and at which stage of the NPD process suppliers are invited to participate in platform designs. A case study of Oticon, a Danish manufacturer of hearing aids, is presented. We describe how the successful introduction of a new platform of hearing aids is realized as well as how and when Oticon’s suppliers were involved during this process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Older adults frequently report that they can hear what they have been told but cannot understand the meaning. This is particularly true in noisy conditions, where the additional challenge of suppressing irrelevant noise (i.e. a competing talker) adds another layer of difficulty to their speech understanding. Hearing aids improve speech perception in quiet, but their success in noisy environments has been modest, suggesting that peripheral hearing loss may not be the only factor in the older adult’s perceptual difficulties. Recent animal studies have shown that auditory synapses and cells undergo significant age-related changes that could impact the integrity of temporal processing in the central auditory system. Psychoacoustic studies carried out in humans have also shown that hearing loss can explain the decline in older adults’ performance in quiet compared to younger adults, but these psychoacoustic measurements are not accurate in describing auditory deficits in noisy conditions. These results would suggest that temporal auditory processing deficits could play an important role in explaining the reduced ability of older adults to process speech in noisy environments. The goals of this dissertation were to understand how age affects neural auditory mechanisms and at which level in the auditory system these changes are particularly relevant for explaining speech-in-noise problems. Specifically, we used non-invasive neuroimaging techniques to tap into the midbrain and the cortex in order to analyze how auditory stimuli are processed in younger (our standard) and older adults. We will also attempt to investigate a possible interaction between processing carried out in the midbrain and cortex.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Estudio cualitativo exploratorio con enfoque fenomenológico que estudió en 10 Niños, Niñas y Adolescentes Sordos / HipoAcústicos (NNA-S/HA) las relaciones de convivencia con la familia, los profesionales de salud, los maestros, los amigos, la comunidad sorda; las cualidades de resiliencia de los NNA-S/HA encontró que las madres aunque tienen altos niveles de estrés son las que afrontan las dificultades y apoyan la intervención, los NNA-S/HA se refugian en sus madres; y los padres se retraen en sus sentimientos y evaden los problemas, y por eso abandonan el hogar al enterarse de que su hijo es sordo. Los profesionales carecen de estrategias para la atención y la comunicación, son distantes del NNA-S/HA, las familias relatan mala calidad en los servicios de salud. Los maestros y los amigos de los NNA-S/HA que van escuelas regulares les excluyen causando convivencias desagradables para los NNA-S/HA. Aquellos que se encuentran en la escuela para sordos se sienten más adaptados, con mejor autoestima y son más resiliente. La mitad de los NNA-S/HA usan dispositivos auditivos pero todos usan o lengua de señas formal o señas familiares para comunicarse con sus amigos y familias. Los NNA-S/HA que usan los dispositivos auditivos no tienen contacto con la comunidad sorda de su región no así los otros que no lo usan y cuya lengua principal es la de señas. Los NNA-S/HA desarrollan como todos los demás sueños, proyectos de vida y luchan por conseguirlo. El estudio permite plantear hipótesis para futuras investigaciones en torno a las estrategias de afrontamiento de las familias, la resiliencia de los NNA-S/HA y la asociación con las relaciones de convivencia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: To compare oral health and hearing outcomes from the Clinical Standards Advisory Group (CSAG, 1998) and the Cleft Care UK (CCUK, 2013) studies. SETTING AND SAMPLE POPULATION: Two UK-based cross-sectional studies of 5-year-olds born with non-syndromic unilateral cleft lip and palate undertaken 15 years apart. CSAG children were treated in a dispersed model of care with low-volume operators. CCUK children were treated in a centralized, high volume operator system. MATERIALS AND METHODS: Oral health data were collected using a standardized proforma. Hearing was assessed using pure tone audiometry and middle ear status by otoscopy and tympanometry. ENT and hearing history were collected from medical notes and parental report. RESULTS: Oral health was assessed in 264 of 268 children (98.5%). The mean dmft was 2.3, 48% were caries free, and 44.7% had untreated caries. There was no evidence this had changed since the CSAG survey. Oral hygiene was generally good, 96% were enrolled with a dentist. Audiology was assessed in 227 of 268 children (84.7%). Forty-three per cent of children received at least one set of grommets--a 17.6% reduction compared to CSAG. Abnormal middle ear status was apparent in 50.7% of children. There was no change in hearing levels, but more children with hearing loss were managed with hearing aids. CONCLUSIONS: Outcomes for dental caries and hearing were no better in CCUK than in CSAG, although there was reduced use of grommets and increased use of hearing aids. The service specifications and recommendations should be scrutinized and implemented.