934 resultados para full-scale testing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The full-scale base-isolated structure studied in this dissertation is the only base-isolated building in South Island of New Zealand. It sustained hundreds of earthquake ground motions from September 2010 and well into 2012. Several large earthquake responses were recorded in December 2011 by NEES@UCLA and by GeoNet recording station nearby Christchurch Women's Hospital. The primary focus of this dissertation is to advance the state-of-the art of the methods to evaluate performance of seismic-isolated structures and the effects of soil-structure interaction by developing new data processing methodologies to overcome current limitations and by implementing advanced numerical modeling in OpenSees for direct analysis of soil-structure interaction.

This dissertation presents a novel method for recovering force-displacement relations within the isolators of building structures with unknown nonlinearities from sparse seismic-response measurements of floor accelerations. The method requires only direct matrix calculations (factorizations and multiplications); no iterative trial-and-error methods are required. The method requires a mass matrix, or at least an estimate of the floor masses. A stiffness matrix may be used, but is not necessary. Essentially, the method operates on a matrix of incomplete measurements of floor accelerations. In the special case of complete floor measurements of systems with linear dynamics, real modes, and equal floor masses, the principal components of this matrix are the modal responses. In the more general case of partial measurements and nonlinear dynamics, the method extracts a number of linearly-dependent components from Hankel matrices of measured horizontal response accelerations, assembles these components row-wise and extracts principal components from the singular value decomposition of this large matrix of linearly-dependent components. These principal components are then interpolated between floors in a way that minimizes the curvature energy of the interpolation. This interpolation step can make use of a reduced-order stiffness matrix, a backward difference matrix or a central difference matrix. The measured and interpolated floor acceleration components at all floors are then assembled and multiplied by a mass matrix. The recovered in-service force-displacement relations are then incorporated into the OpenSees soil structure interaction model.

Numerical simulations of soil-structure interaction involving non-uniform soil behavior are conducted following the development of the complete soil-structure interaction model of Christchurch Women's Hospital in OpenSees. In these 2D OpenSees models, the superstructure is modeled as two-dimensional frames in short span and long span respectively. The lead rubber bearings are modeled as elastomeric bearing (Bouc Wen) elements. The soil underlying the concrete raft foundation is modeled with linear elastic plane strain quadrilateral element. The non-uniformity of the soil profile is incorporated by extraction and interpolation of shear wave velocity profile from the Canterbury Geotechnical Database. The validity of the complete two-dimensional soil-structure interaction OpenSees model for the hospital is checked by comparing the results of peak floor responses and force-displacement relations within the isolation system achieved from OpenSees simulations to the recorded measurements. General explanations and implications, supported by displacement drifts, floor acceleration and displacement responses, force-displacement relations are described to address the effects of soil-structure interaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A major weakness among loading models for pedestrians walking on flexible structures proposed in recent years is the various uncorroborated assumptions made in their development. This applies to spatio-temporal characteristics of pedestrian loading and the nature of multi-object interactions. To alleviate this problem, a framework for the determination of localised pedestrian forces on full-scale structures is presented using a wireless attitude and heading reference systems (AHRS). An AHRS comprises a triad of tri-axial accelerometers, gyroscopes and magnetometers managed by a dedicated data processing unit, allowing motion in three-dimensional space to be reconstructed. A pedestrian loading model based on a single point inertial measurement from an AHRS is derived and shown to perform well against benchmark data collected on an instrumented treadmill. Unlike other models, the current model does not take any predefined form nor does it require any extrapolations as to the timing and amplitude of pedestrian loading. In order to assess correctly the influence of the moving pedestrian on behaviour of a structure, an algorithm for tracking the point of application of pedestrian force is developed based on data from a single AHRS attached to a foot. A set of controlled walking tests with a single pedestrian is conducted on a real footbridge for validation purposes. A remarkably good match between the measured and simulated bridge response is found, indeed confirming applicability of the proposed framework.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on the development of specifications for an on-board mass monitoring (OBM) application for regulatory requirements in Australia. An earlier paper reported on feasibility study and pilot testing program prior to the specification development [1]. Learnings from the pilot were used to refine this testing process and a full scale testing program was conducted from July to October 2008. The results from the full scale test and evidentiary implications are presented in this report. The draft specification for an evidentiary on-board mass monitoring application is currently under development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This project set out to investigate the behaviour of a pole frame house subjected to a lateral wind load. The behaviour of poles embedded in the ground was examined. The existing theoretical methods for determining lateral load capacity of an embedded pole were reviewed, and three common methods of pole embedment were tested at different depths to gauge the response of poles and types of pole embedment to a lateral load. The most suitable embedment method was used in the foundation for a full-scale model pole house, which was constructed and tested at various stages during the construction to examine the response of a pole house to lateral wind load. The full scale testing was also used to monitor the effect of the various structural components on the overall stiffuess of the house. The results from the full scale tests were used to calibrate a computer model of a pole house which could then be used to predict the behaviour of different configurations of pole house construction without the need for further expensive full scale tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on the development of specifications for an on-board mass monitoring (OBM) application for regulatory requirements in Australia. An earlier paper reported on feasibility study and pilot testing program prior to the specification development [1]. Learnings from the pilot were used to refine this testing process and a full scale testing program was conducted from July to October 2008. The results from the full scale test and evidentiary implications are presented in this report. The draft specification for an evidentiary on-board mass monitoring application is currently under development.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analysis of the variability in the responses of large structural systems and quantification of their linearity or nonlinearity as a potential non-invasive means of structural system assessment from output-only condition remains a challenging problem. In this study, the Delay Vector Variance (DVV) method is used for full scale testing of both pseudo-dynamic and dynamic responses of two bridges, in order to study the degree of nonlinearity of their measured response signals. The DVV detects the presence of determinism and nonlinearity in a time series and is based upon the examination of local predictability of a signal. The pseudo-dynamic data is obtained from a concrete bridge during repair while the dynamic data is obtained from a steel railway bridge traversed by a train. We show that DVV is promising as a marker in establishing the degree to which a change in the signal nonlinearity reflects the change in the real behaviour of a structure. It is also useful in establishing the sensitivity of instruments or sensors deployed to monitor such changes. (C) 2015 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper a methodology for the application of computer simulation to the evacuation certification of aircraft is suggested. The methodology suggested here involves the use of computer simulation, historic certification data, component testing and full-scale certification trials. The proposed methodology sets out a protocol for how computer simulation should be undertaken in a certification environment and draws on experience from both the marine and building industries. Along with the suggested protocol, a phased introduction of computer models to certification is suggested. Given the sceptical nature of the aviation community regarding any certification methodology change in general, this would involve as a first step the use of computer simulation in conjunction with full-scale testing. The computer model would be used to reproduce a probability distribution of likely aircraft performance under current certification conditions and in addition, several other more challenging scenarios could be developed. The combination of full-scale trial, computer simulation (and if necessary component testing) would provide better insight into the actual performance capabilities of the aircraft by generating a performance probability distribution or performance envelope rather than a single datum. Once further confidence in the technique is established, the second step would only involve computer simulation and component testing. This would only be contemplated after sufficient experience and confidence in the use of computer models have been developed. The third step in the adoption of computer simulation for certification would involve the introduction of several scenarios based on for example exit availability instructed by accident analysis. The final step would be the introduction of more realistic accident scenarios into the certification process. This would require the continued development of aircraft evacuation modelling technology to include additional behavioural features common in real accident scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper a methodology for the application of computer simulation to evacuation certification of aircraft is suggested. This involves the use of computer simulation, historic certification data, component testing, and full-scale certification trials. The methodology sets out a framework for how computer simulation should be undertaken in a certification environment and draws on experience from both the marine and building industries. In addition, a phased introduction of computer models to certification is suggested. This involves as a first step the use of computer simulation in conjunction with full-scale testing. The combination of full-scale trial, computer simulation (and if necessary component testing) provides better insight into aircraft evacuation performance capabilities by generating a performance probability distribution rather than a single datum. Once further confidence in the technique is established the requirement for the full-scale demonstration could be dropped. The second step in the adoption of computer simulation for certification involves the introduction of several scenarios based on, for example, exit availability, instructed by accident analysis. The final step would be the introduction of more realistic accident scenarios. This would require the continued development of aircraft evacuation modeling technology to include additional behavioral features common in real accident scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rigid wall model has been used widely in the numerical simulation of rail vehicle impacts. Finite element impact modelling of rail vehicles is generally based on a half-width and full-length or half-length structure, depending on the symmetry. The structure and components of rail vehicles are normally designed to cope with proof loading to ensure adequate ride performance. In this paper, the authors present a study of a rail vehicle with driving cab focused on improving the modelling approach and exploring the intrinsic structural weaknesses to enhance its crashworthiness. The underpinning research used finite element analysis and compared the behaviour of the rail vehicle in different impact scenarios. It was found that the simulation of a rigid wall impact can mask structural weaknesses; that even a completely symmetrical impact may lead to an asymmetrical result; that downward bending is an intrinsic weakness of conventional rail vehicles and that a rigid part of the vehicle structure, such as the body bolster, may cause uncoordinated deformation and shear fracture between the vehicle sections. These findings have significance for impact simulation, the full-scale testing of rail vehicles and rail vehicle design in general.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a novel method for modelling a scaled vehicle–barrier crash test similar to the 20◦ angled barrier test specified in EN 1317 is reported. The intended application is for proof-of-concept evaluation of novel roadside barrier designs, and as a cost-effective precursor to full-scale testing or detailed computational modelling. The method is based on the combination of the conservation of energy law and the equation of motion of a spring mass system representing the impact, and shows, for the first time, the feasibility of applying classical scaling theories to evaluation of roadside barrier design. The scaling method is used to set the initial velocity of the vehicle in the scaled test and to provide scaling factors to convert the measured vehicle accelerations in the scaled test to predicted full-scale accelerations. These values can then be used to calculate the Acceleration Severity Index score of the barrier for a full-scale test. The theoretical validity of the method is demonstrated by comparison to numerical simulations of scaled and full-scale angled barrier impacts using multibody analysis implemented in the crash simulation software MADYMO. Results show a maximum error of 0.3% ascribable to the scaling method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper shows the process of the virtual production development of the mechanical connection between the top leaf of a dual composite leaf spring system to a shackle using finite element methods. The commercial FEA package MSC/MARC has been used for the analysis. In the original design the joint was based on a closed eye-end. Full scale testing results showed that this configuration achieved the vertical proof load of 150 kN and 1 million cycles of fatigue load. However, a problem with delamination occurred at the interface between the fibres going around the eye and the main leaf body. To overcome this problem, a second design was tried using transverse bandages of woven glass fibre reinforced tape to wrap the section that is prone to delaminate. In this case, the maximum interlaminar shear stress was reduced by a certain amount but it was still higher than the material’s shear strength. Based on the fact that, even with delamination, the top leaf spring still sustained the maximum static and fatigue loads required, the third design was proposed with an open eye-end, eliminating altogether the interface where the maximum shear stress occurs. The maximum shear stress predicted by FEA is reduced significantly and a safety factor of around 2 has been obtained. Thus, a successful and safe design has been achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Canada, increases in rural development has led to a growing need to effectively manage the resulting municipal and city sewage without the addition of significant cost- and energy- expending infrastructure. Storring Septic Service Limited is a family-owned, licensed wastewater treatment facility located in eastern Ontario. It makes use of a passive waste stabilization pond system to treat and dispose of waste and wastewater in an environmentally responsible manner. Storring Septic, like many other similar small-scale wastewater treatment facilities across Canada, has the potential to act as a sustainable eco-engineered facility that municipalities and service providers could utilize to manage and dispose of their wastewater. However, it is of concern that the substantial inclusion of third party material could be detrimental to the stability and robustness of the pond system. In order to augment the capacity of the current facility, and ensure it remains a self-sustaining system with the capacity to safely accept septage from other sewage haulers, it was hypothesized that pond effluent treatment could be further enhanced through the incorporation of one of three different technology solutions, which would allow the reduction of wastewater quality parameters below existing regulatory effluent discharge limits put in place by Ontario’s Ministry of the Environment and Climate Change (MOECC). Two of these solutions make use of biofilm technologies in order to enhance the removal of wastewater parameters of interest, and the third utilizes the natural water filtration capabilities of zebra mussels. Pilot-scale testing investigated the effects of each of these technologies on treatment performance under both cold and warm weather operation. This research aimed to understand the important mechanisms behind biological filtration methods in order to choose and optimize the best treatment strategy for full-scale testing and implementation. In doing so, a recommendation matrix was elaborated provided with the potential to be used as a universal operational strategy for wastewater treatment facilities located in environments of similar climate and ecology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The authors would like to thank their supporters. New Zealand Earthquake Commission (EQC) Research Foundation provided financial support for experimental work (Grant No. UNI/578). New Zealand Transport Agency (NZTA) provided access to the bridge. Piotr Omenzetter’s work within the LRF Centre for Safety and Reliability Engineering at the University of Aberdeen is supported by Lloyd’s Register Foundation. The Foundation helps to protect life and property by supporting engineering-related education, public engagement and the application of research. Ge-Wei Chen’s doctoral study is supported by China Scholarship Council (CSC) (Grant No. 2011637065).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Canada, increases in rural development has led to a growing need to effectively manage the resulting municipal and city sewage without the addition of significant cost- and energy- expending infrastructure. Storring Septic Service Limited is a family-owned, licensed wastewater treatment facility located in eastern Ontario. It makes use of a passive waste stabilization pond system to treat and dispose of waste and wastewater in an environmentally responsible manner. Storring Septic, like many other similar small-scale wastewater treatment facilities across Canada, has the potential to act as a sustainable eco-engineered facility that municipalities and service providers could utilize to manage and dispose of their wastewater. However, it is of concern that the substantial inclusion of third party material could be detrimental to the stability and robustness of the pond system. In order to augment the capacity of the current facility, and ensure it remains a self-sustaining system with the capacity to safely accept septage from other sewage haulers, it was hypothesized that pond effluent treatment could be further enhanced through the incorporation of one of three different technology solutions, which would allow the reduction of wastewater quality parameters below existing regulatory effluent discharge limits put in place by Ontario’s Ministry of the Environment and Climate Change (MOECC). Two of these solutions make use of biofilm technologies in order to enhance the removal of wastewater parameters of interest, and the third utilizes the natural water filtration capabilities of zebra mussels. Pilot-scale testing investigated the effects of each of these technologies on treatment performance under both cold and warm weather operation. This research aimed to understand the important mechanisms behind biological filtration methods in order to choose and optimize the best treatment strategy for full-scale testing and implementation. In doing so, a recommendation matrix was elaborated provided with the potential to be used as a universal operational strategy for wastewater treatment facilities located in environments of similar climate and ecology.