925 resultados para espectrometria


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of veterinary drug residues in foods of animal origin is an important issue because of the risk these compounds pose to human health in addition to their persistence and tendency to bioaccumulate. In recent years, significant progress has been made in the area and this review presents the state of the art in sample preparation procedures associated with chromatographic techniques coupled to mass spectrometry for multiresidue determination of veterinary drugs in food of animal origin at concentration levels suitable for the control of residues and contaminants in food.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a method for determination of hexavalent chromium in aqueous samples using liquid-liquid microextraction (LLME) and detection by Flame Atomic Absorption Spectrometry (F AAS) was developed. The LLME procedure was based on the extraction of Cr (VI) by acetone at a sample pH of 1.2. The use of saturated ammonium sulphate solution allowed effective separation of the aqueous and organic phases and acetone extracted chromium. The sample pH, acetone volume and stirring time were optimized by a full factorial design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the development of methods in micro-scale for the determination of K, Mg, Na and Zn in meat by atomic spectrometry techniques. The limits of detection (LOD) for K and Na by microdigestion were 0.18 and 0.20 mg g-1, respectively whereas LOD for Mg and Zn by microsolubilization with TMAH were 2.40 and 18.4 µg g-1, respectively. The RSD values were lower than 6.0% and the CRMs analyzed showed values with 95% agreement. The proposed methods are simple, fast and use small amounts of sample (around 10 mg) yet do not require special equipment for sample preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports a practical case based on the use of microwave-assisted derivatization and GC-MS for the analysis of glucose. Using two different methods for derivatization, one reference compound and the calculated dipole moment, all the isomers of glucose were identified. Identification was corroborated for the assignment of structures using the mass spectra. With this work, students are expected to associate different types of information to solve the complex problem of the analysis of glucose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 µL resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 µg L-1 were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This aim of this work was to compare two methods for copper determination in insulating oils from power transformers by GFAAS. The first method was extraction induced by emulsion breaking, which determined the preconcentration of copper in an aqueous solution and exhibited a limit of quantification of 0.27 µg L-1. Also, a second method based on the direct introduction of samples into GFAAS in the form of detergent emulsions, prepared with Triton X-114 and HNO3, was investigated. In this case, the limit of quantification was 1.7 µg L-1. Seven samples of used oils were successfully analyzed by both methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the evaluation of simple and fast solubilization methods for the determination of Ca, Mg, and K in glycerin samples from biodiesel production by atomic spectrometry. The solubilization in water was compared with two other methods: solubilization in formic acid and solubilization in ethanol. Using solubilization in water, determination of the three analytes was possible; the values of limits of detection for Ca, K, Mg were 0.31, 0.06, and 0.16 mg kg−1, respectively. Because no adequate reference material was available, the accuracy was evaluated by assessing the recoveries tests with both solubilization methods; the evaluation ranged from 90% to 115%, with values of relative standard deviation >8%, indicating good accuracy of the measure. Four crude glycerin samples obtained from biodiesel plants of Rio Grande do Sul were analyzed after treatment with the different methods of solubilization, and the obtained results of Ca, Mg, and K concentration were in agreement with the values obtained from both solubilization methods. Therefore, solubilization in water is concluded to be a simpler, faster, and viable method for sample preparation of glycerin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure for ultrasound-assisted extraction and colorimetric determination of iron in soil samples was developed. The iron concentration in the analyzed samples was determined by the colorimetric method and the results compared with inductively coupled plasma mass spectrometry (ICP-MS). Fifteen soil samples were analyzed and the iron concentration results compared with those obtained by ICP-MS using microwave-assisted sample digestion. The proposed procedure showed good efficiency for iron extraction and the results obtained by colorimetric determination exhibited good agreement with ICP-MS. Moreover, ultrasound-assisted extraction and colorimetric determination is a simple, fast and low-cost procedure for application in routine analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Um sistema de injeção em fluxo envolvendo complexação com dietilditiofosfato de amônio e sorção de complexos metálicos em minicolunas de sílica gel modificada por grupos octadecil C18 é proposto para determinações multielementares em espectrometria de massa com plasma indutivamente acoplado. Influência da concentração de reagentes, natureza do ácido, tempo de reação, tempos de comutação, vazões e interferência de sódio foram investigadas. Água ou solução 2% v/v HNO3 podem ser utilizadas para lavar a coluna antes da eluição dos analitos com etanol. Amostras contendo 5000 mg Na L-1 e analisadas diretamente com o sistema proposto produzem uma concentração aparente de 63Cu de 0,45 µg L-1; por outro lado não foi observada interferência para As, Pb, Bi, Se, In, Tl, Cd, Hg e 65Cu. Para 0,25 % w/v NH4DTP e 3 mL de solução de amostra, curvas analíticas para Bi, Cu, Pb, As, Se, In, Tl, Cd, Hg no intervalo de 0,10 a 2,00 µg L-1 podem ser construídas com boas correlações (r2 > 0.998). A velocidade analítica e sensibilidade podem ser melhoradas pois dependem das condições de pré-concentração e eluição selecionadas. Com os parâmetros acima fixados, limites de detecção de 0.014 (Cu), 0.027 (As), 0.06 (Se), 0.02 (Cd), 0.029 (In), 0.043 (Hg), 0.02 (Tl), 0.06 (Pb) e 0.002 µg L-1 (Bi) foram obtidos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho descreve uma revisão a respeito do emprego da técnica de espectrometria de absorção atômica simultânea em forno de grafite (SIMAAS) em determinações multielementares de elementos-traço em diferentes matrizes. Os principais parâmetros envolvidos e que devem ser considerados em medidas multielementares, tais como, fonte de radiação, geometria do forno, programa de aquecimento e natureza e quantidade de modificador químico, são descritos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A influência de digeridos e suspensões de açúcar no comportamento térmico de As usando Pd(NO3)2, Pd(NO3)2 + Mg(NO3)2, and Ni(NO3)2 como modificadores químicos foi investigada. Influência de 0,2%, 5%, 10% e 35% (v/v) HNO3 na calibração (1,00 - 10,0 µg As L-1) também foi feita. Um volume de 20 µL de amostra mais 5 µL Pd ou 5 µL Pd + 3 µL Mg, ou 20 µL Ni foi injetado no atomizador do GF AAS. Para cada modificador, temperaturas de pirólise e atomização foram avaliadas por meio de curvas de pirólise e de atomização, respectivamente. Para suspensão de açúcar, temperaturas de pirólise e atomização (Tp, Ta) obtidas foram: sem modificador (400° C, 2000° C); Pd (1400° C, 2200° C); Pd/Mg (1400° C, 2200° C) e Ni (1600° C, 2200° C). Os valores para digeridos de açúcar foram: sem modificador (400° C, 2200° C); Pd (1400° C, 2200° C); Pd/Mg (1400° C, 2200° C) e Ni (600° C, 2200° C). Paládio foi selecionado como o melhor modificador químico. O tempo de vida do tubo de grafte foi de aproximadamente 350 queimas, o RSD (n = 12) para uma amostra típica contendo 5,52 µg As L-1 foi < 2,2% e o limite de detecção foi 2,4 pg As. Recuperações entre 80 e 92% foram encontradas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho propõe um método simples, rápido e confiável para determinação direta e simultânea de Al, As, Fe, Mn e Ni em cachaça por espectrometria de absorção atômica em forno de grafite (GFAAS). A superfície superior da plataforma do tubo de grafite foi revestida com filme à base de tungstênio (WxCyOz).O programa de aquecimento otimizado (temperatura, tempo de rampa, tempo de patamar) foi o seguinte: secagem 1 (100ºC, 5 s, 5 s); secagem 2 (120ºC, 5 s, 5 s); pirólise (1300ºC, 10 s, 30 s); atomização (2200ºC, 1 s, 6 s) e limpeza (2550ºC, 1 s, 3s). Os desvios padrões relativos (n=3) foram < 4,4%, < 0,7%, < 11%, < 6,0%, < 1,2% para os elementos Al, As, Fe, Mn e Ni, respectivamente. A exatidão foi avaliada por meio de testes de adição e recuperação dos analitos em 8 amostras de cachaças comerciais, e as recuperações situaram-se nos seguintes intervalos: 80 - 105% (Al), 81 - 92% (As), 82 - 108% (Fe), 83 - 106% (Mn), 83 - 108% (Ni). Os limites de detecção calculados foram 9,7 µg L-1 Al, 2,3 µg L-1 As, 12 µg L-1 Fe, 14 µg L-1 Mn e 0,8 µg L-1 Ni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A determinação de selênio utilizando a geração de hidretos acoplada às técnicas atômicas vêm sendo utilizada com sucesso em amostras de urina. Devido a necessidade de se dispor de um método analítico capaz de determinar pequenas quantidades de selênio; é proposto o sistema de fluxo, por zonas coalescentes, utilizando a técnica de geração de hidretos, seguida da detecção por espectrometria de absorção atômica para a determinação de selênio em amostras de urina. O limite de detecção obtido é 0,3 ng mL-1, correspondendo a 30 pg de selênio e a freqüência analítica de 140 determinações por hora. A precisão (d.p.r.) do método foi de 2,0% para 1,0 ng mL-1. A quantidade de reagente (0,5 mg de NaBH4 para cada determinação) e de resíduo químico gerado no laboratório (170 mL h-1) é mínima. A aplicação do método proposto para análises de amostras de urina evidenciou a presença média de 4,0 ng mL-1 de selênio para pacientes que não ingeriram nenhum medicamento contendo selênio. Para pacientes que ingeriram uma dose única de medicamento contendo selênio, o teor encontrado nas amostras de urina analisadas variaram de 5,0 a 16,0 ng mL-1. Estudos de recuperação mostraram valores de 90,0% e 103,0% para 1,0 e 10,0 ng mL-1 de selênio adicionado, respectivamente, nas amostras de urina. A certificação do método foi avaliada para análises de material de referência de urina SRM 2670 (valor certificado: 30,0±8,0 ng mL-1 e valor obtido: 27,0±2,0 ng mL-1).