975 resultados para enzyme-linked immunosorbent assay (ELISA)
Resumo:
Soluble adult Schistosoma mansoni antigen preparation (SWAP) was covalently fixed onto polyvinyl alcohol-glutaraldehyde discs and an enzyme linked-immunosorbent assay (ELISA) was set up. The best conditions for the assay were established and it was found that small amount of antigen such as 1.5 µg was required. A comparison between this procedure and the conventional ELISA was proceeded. A reliable method of antigen immobilization was achieved and the low prices of the employed reagents are economically attractive
Resumo:
Considering the impact of cysticercosis on public health, especially the neurologic form of the disease, neurocysticercosis (NC), we studied the frequency of positivity of anti-Taenia solium cysticercus antibodies in serum samples from 1,863 inhabitants of Cássia dos Coqueiros, SP, a municipal district located 80 km from Ribeirão Preto, an area considered endemic for cysticercosis. The 1,863 samples were tested by enzyme linked immunosorbent assay (ELISA) using an antigenic extract from Taenia crassiceps vesicular fluid (Tcra). The reactive and inconclusive ELISA samples were tested by immunoblotting. Of the 459 samples submitted to immunoblotting, 40 were strongly immunoreactive to the immunodominant 18 and 14 kD peptides. Considering the use of immunoblotting as confirmatory due to its high specificity, the anti-cysticercus serum prevalence in this population was 2.1%.
Resumo:
Using the indirect hemagglutination (IH), indirect immunofluorescence (IIF) and enzyme linked immunosorbent assay (ELISA) tests for the diagnosis of Chagas disease, 4000 serum samples were examined. This study was conducted with different purposes: clinical interest, research support and parasitological monitoring of those patients with Chagas disease who were treated with heart transplantations. The tests occurred without patient selection and in accordance with the medical requests. The results showed discrepancies and brought about several questions, considering the different results that all three methods showed when considered together. What was found brought about concerns and we suggest the adoption of different measures, aiming to avoid these mismatches in the context of this disease.
Resumo:
INTRODUCTION: The laboratory diagnosis of schistosomiasis is based mainly on the detection of parasite eggs in stool samples through the Kato-Katz (KK) technique, reading one slide by test. However, a widely known limitation of parasitological methods is reduced sensitivity, particularly in low endemic areas. METHODS: To increase sensitivity, we conducted further slide readings from the same stool sample using the parasitological method associated with a serological test. We used the KK method (three slides) and the IgG anti-Schistosoma mansoni-enzyme-linked immunosorbent assay (ELISA) technique to diagnose schistosomiasis in low endemic areas in the Brazilian State of Ceará. Fecal samples and sera from 250 individuals were analyzed. RESULTS: Sixteen percent and 47.2% of samples were positive in parasitological tests and serological tests, respectively. Parasitological methods showed that 32 (80%) individuals tested positive on the first slide, 6 (15%) on the second slide, and 2 (5%) on the third. The performance of the ELISA test in the diagnosis, using the KK method as diagnostic reference, showed a negative predictive value of 100%, with specificity and positive predictive values of 62.8% and 33.9%, respectively. CONCLUSIONS: In this study, the increase from one to three slides analyzed per sample using the KK technique was shown to be a useful procedure for increasing the diagnostic sensitivity of this technique.
Resumo:
Discs of polyvinyl alcohol cross-linked with glutaraldehyde were synthesized under acid catalysis (H2SO4). Then, the antigen F1 purified from Yersinia pestis was covalently linked to this modified polymer. Afterwards, an enzyme-linked immunosorbent assay (ELISA) was established for the diagnosis of plague in rabbit and human. The best conditions for the method were achieved by using 1.3 ¼g of F1 prepared in 0.067 M phosphate buffer, pH 7.2, containing 1 M NaCl (PBS); anti-IgG peroxidase conjugate diluted 6,000 times and as a blocking agent 3% w/v skim milk in PBS. The titration of positive rabbit serum according to this procedure detected antibody concentrations up to 1:12,800 times. The present method, the conventional ELISA and passive haemagglutination assay are compared.
Resumo:
The high sensitivity and the possibility of automation of the enzyme-linked-immunosorbent-assay (ELISA) has indicated this technique as one of the most useful serological test for epidemiological studies. In the present study, an ELISA for detection of IgG antibodies against adult worm antigens (IgG-ELISA) was investigated for epidemiological purposes, in a rural area of the municipality of Itariri (São Paulo, Brazil). Blood on filter paper (1,180 samples) from about 650 schoolchildren were submitted to ELISA and the data compared to the results of the parasitological method of Kato-Katz and also to the IgM-IFT (immunofluorescence test for IgM antibodies to gut associated antigens). The prevalence rates respectively of 8.5%, 43.0%, and 56.2% by the Kato-Katz, IgG-ELISA, and IgM-IFT methods suggest the poor sensitivity of the parasitological method for detection of Schistosoma mansoni eggs in individuals with low worm burden, situation commonly observed in low endemic areas. These results can partially explain the poor degree of agreement between the IgG-ELISA and the Kato-Katz, as suggested by the Kappa index of 0.170. Otherwise, the Kappa index of 0.675 showed substantial agreement between the two serological tests. Some discrepancy of results between the two serological techniques must be better investigated.
Resumo:
Indirect enzyme-linked immunosorbent assays (ELISAs) based on recombinant MSP1a and MSP2 from a Brazilian isolate of Anaplasma marginale were developed to detect antibodies against this rickettsia in cattle. The high sensitivities (99% for both tests) and specificities (100% for both tests) were confirmed with sera from cattle positive or negative for A. marginale antibodies, respectively, by immunofluorescent antibody test. By the analysis of 583 sera from cattle of three regions of the state of Pernambuco, Brazil, the agreement between both tests was high, with a kappa index of 0.89. The similar performances of the ELISAs suggest that both tests can be used in epidemiological surveys for detection of antibodies to A. marginale in cattle.
Resumo:
A rapid indirect enzyme-linked immunosorbent assay (ELISA) was developed for measuring antibodies against Leishmania chagasi using total antigen from lysed promastigotes. Fifty symptomatic mixed breed dogs from a region of high incidence of visceral leishmaniasis in Brazil were examined. The results showed that in the positive animals, diagnosed by cytological examination, the ELISA using protein A assay system (mean optical density ± SD / 2.078 ± 0.631) detected more antibodies than the anti-IgG assay (mean optical density ± SD / 1.008 ± 0.437), while in the negative animals, the results by both systems were similar. These results suggest that the ELISA assay using protein A peroxidase conjugated could be useful to detect early infected animals in endemic areas, and thus help to control the spread of the infection.
Resumo:
A comparação das técnicas de Enzyme Linked Immunosorbent Assay (ELISA) e cromatografia em camada delgada (CCD) por quantificação visual e densitométrica foi utilizada na determinação de aflatoxina total, em amostras de milho naturalmente contaminadas. Os teores de aflatoxina total encontrados pelas técnicas de CCD e ELISA, apresentaram maior freqüência na faixa de 0-30 mig/kg e acima de 300 mig/kg. Os resultados das amostras apresentaram coeficiente de variação concentrados abaixo de 20, 30 e 40% para a técnica de ELISA e CCD com quantificação densitométrica e visual, respectivamente. Os coeficientes de correlação foram altamente significativos para as relações entre as quantificações visual e densitométrica (r = 0,9219; t = 26,36; p < 0,001), ELISA e visual (r = 0,8277; t = 17,58; p < 0,001), ELISA e densitometria (r = 0,7373; t = 13,01; p < 0,001), na determinação de aflatoxina total em todas as amostras de milho pesquisadas, confirmando haver equivalência das técnicas estudadas.
Resumo:
In the present study, the validation of an enzyme-linked immunosorbent assay (ELISA) for serodiagnosis of canine brucellosis is described. Two different antigenic extracts, obtained by heat or ultrasonic homogenization of microbial antigens from a wild isolate of Brucella canis bacteria, were compared by ELISA and Western blot (WB). A total of 145 canine sera were used to define sensitivity, specificity and accuracy of the ELISA as follows: (1) sera from 34 animals with natural B. canis infection, confirmed by blood culture and PCR, as well as 51 sera samples from healthy dogs with negative results by the agar-gel immunodiffusion (ACID) test for canine brucellosis, were used as the control panel for B. cants infection; and (2) to scrutinize the possibility of cross reactions with other common dog infections in the same geographical area in Brazil, 60 sera samples from dogs harboring known infections by Leptospira sp., Ehrlichia canis, canine distemper virus (CDV), Neospora caninum, Babesia canis and Leishmania chagasi (10 in each group) were included in the study. The ELISA using heat soluble bacterial extract (HE-antigen) as antigen showed the best values of sensitivity (91.18%), specificity (100%) and accuracy (96.47%). In the WB analyses, the HE-antigen showed no cross-reactivity with sera from dogs with different infections, while the B. canis sonicate had various protein bands identified by those sera. The performance of the ELISA standardized with the heat soluble B. canis antigen indicates that this assay can be used as a reliable and practical method to confirm infection by this microorganism, as well as a tool for seroepidemiological studies. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
O presente trabalho estudou um ensaio imunoenzimático (ELISA) indireto para a detecção de anticorpos anti-Babesia canis no soro de cães, tendo a Reação de Imunofluorescência Indireta (RIFI), como teste de referência O antígeno utilizado no ELISA do presente estudo consistiu em uma preparação antigênica solúvel de merozoítas B. canis e as diluições ótimas do antígeno, soros e conjugado foram determinadas por titulação em bloco, utilizando soros de referência positivos e negativos. A preparação antigênica solúvel de B. canis ótima foi de 10 µg.mL-1, com soros de referência positivos e negativos em uma única diluição de 1:100, e conjugado a 1:4.000. Um total de 246 amostras séricas foram colhidas em cães, durante a campanha de vacinação anti-rábica em Jaboticabal, São Paulo, Brasil e a presença de anticorpos anti-B. canis foi avaliada pelo ELISA e RIFI. Nestas condições, a média de absorbância dos soros de referência negativos foi de 0,129 ± 0,025, resultando em um ponto de corte de 0,323 (Nível de ELISA 3) e a média da absorbância dos soros de referência positivos foi de 2,156 ± 1,187. As amostras com sorologia positiva para B. canis por ELISA e RIFI foram 67,89% (n = 167) e 59,35% (n = 146), respectivamente. Os resultados obtidos sugerem que o ELISA descrito revelou-se um teste sorológico eficaz no diagnóstico da babesiose canina.
Resumo:
Um ensaio de imunoadsorção enzimática para detecção de anticorpos contra Leishmania chagasi, utilizando antígeno total de formas promastigotas lisados foi desenvolvido. Cinqüenta cães com sintomas clínicos de leishmaniose visceral foram examinados. Esta técnica utilizou anti-IgG de cão conjugado a peroxidase ou proteína A conjugado a peroxidase. Foi verificado que nos animais positivos diagnosticados por exame parasitológico direto o ensaio ELISA utilizando proteína A conjugada a peroxidase (média da densidade óptica ± desvio padrão 2,078 ± 0,631) detecta mais anticorpos do que o sistema utilizando anti-IgG de cão conjugado a peroxidase (média da densidade óptica ± desvio padrão 1,008 ± 0,437), enquanto para os animais negativos o resultado obtido nos dois sistemas de detecção são similares. Esse resultado sugere que o sistema de ELISA utilizando proteína A conjugado a peroxidase pode ser útil na detecção de animais na fase aguda da infecção e desta forma auxiliar na identificação dos animais positivos e no controle desta importante zoonose.
Detection of Cryptosporidium parvum oocysts in calf fecal samples by direct immunofluorescence assay
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Um ensaio de imunoadsorção enzimática (ELISA) baseado em antígeno bruto foi avaliado na detecção de anticorpos contra Babesia bigemina. A sensibilidade e a especificidade do teste foram de 98,0% e 99,0%, respectivamente. Concordando com a alta especificidade do teste, não foram verificadas reações cruzadas com soros de bezerros inoculados três vezes com 10(7) merozoítos de Babesia bovis. Com relação à comparação do ELISA com a imunofluorescência indireta (IFAT) na detecção de anticorpos contra B. bigemina em bezerros experimentalmente infectados com cinco isolados brasileiros geograficamente distintos deste hemoparasito, o IFAT foi capaz de detectar anticorpos um dia antes do ELISA na maioria dos soros dos animais. Houve uma boa concordância entre os resultados encontrados no ELISA e no IFAT com soros de bovinos de região de estabilidade enzoótica (k=0.61). No entanto, não houve concordância entre os testes sorológicos com soros de animais de área de instabilidade enzoótica (k=0.33). O ELISA foi empregado em um inquérito epidemiológico com 1.367 soros de quatro municípios do Pantanal de Mato Grosso do Sul e caracterizou esta região como uma área de estabilidade enzoótica, uma vez que as prevalências variaram de 87,7 a 98,9%. Dessa forma, este ELISA, que apresentou alta sensibilidade, especificidade e desempenho similar ao IFAT, pode ser utilizado no diagnóstico sorológico de B. bigemina.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)