378 resultados para eletrodo de minicavidade


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The textile industry is one of the most polluting in the world (AHMEDCHEKKAT et al. 2011), generating wastewater with high organic loading. Among the pollutants present in these effluents are dyes, substances with complex structures, toxic and carcinogenic characteristics, besides having a strong staining. Improper disposal of these substances to the environment, without performing a pre-treatment can cause major environmental impacts. The objective this thesis to use a technique of electrochemical oxidation of boron doped diamond anode, BDD, for the treatment of a synthetic dye and a textile real effluent. In addition to studying the behavior of different electrolytes (HClO4, H3PO4, NaCl and Na2SO4) and current densities (15, 60, 90 and 120 mA.cm-2 ), and compare the methods with Rhodamine B (RhB) photolysis, electrolysis and photoelectrocatalytic using H3PO4 and Na2SO4. Electrochemical oxidation studies were performed in different ratio sp3 /sp2 of BDD with solution of RhB. To achieve these objectives, analysis of pH, conductivity, UV-visible, TOC, HPLC and GC-MS were developed. Based on the results with the Rhodamine B, it was observed that in all cases occurred at mineralization, independent of electrolyte and current density, but these parameters affect the speed and efficiency of mineralization. The radiation of light was favorable during the electrolysis of RhB with phosphate and sulfate. Regarding the oxidation in BDD anode with different ratio sp3 /sp2 (165, 176, 206, 220, 262 e 329), with lower carbon-sp3 had a longer favoring the electrochemical conversion of RhB, instead of combustion. The greater the carbon content on the anodes BDD took the biggest favor of direct electrochemical oxidation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper suggests modifications in coating of electrodes providing an alternative for execution of welding with low hydrogen electrode AWS E7018 without having to dry it, reducing thus the cost and time of manufacturing of high resistance welds. The welds in this research were developed with basic coated electrodes (hygroscopic) – SMAW process – externally painted with aluminum spray paint for high temperatures or wrapped with thin plastic films (PVC) and aluminum foil films used commonly for food protection. The basic premise is that establishing a barrier between the atmosphere and the electrode coating could reduce the effects of high hygroscopicity presented by coatings of low hydrogen, minimizing this way the main source of supply of hydrogen to the fusion pool during welding. It is also expected that the addition of new materials from the electrode coating to the fusion pool would induce metallurgical changes in the deposited metal and, as a consequence, modifications in its mechanical properties. This research dealt with measuring the dissolved hydrogen in the deposited metal after welding with modified electrodes, evaluating the influence of these changes in the produced microstructures and in the mechanical properties of the resulting weld, and comparing the obtained results with the standard welding procedures and with the recently developed waterproof electrodes. The results obtained in most samples welded with modified electrodes showed increased mechanical resistance and increased tenacity due to the increased percentage of acicular ferrite in metal deposited without significant elevation of hardness, when compared with the traditional welding with AWS E7018 electrode and with ELBRÁS BRH4R waterproof electrode. The diffusing hydrogen measured in the modified electrodes was kept inside the parameters defined by international codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper suggests modifications in coating of electrodes providing an alternative for execution of welding with low hydrogen electrode AWS E7018 without having to dry it, reducing thus the cost and time of manufacturing of high resistance welds. The welds in this research were developed with basic coated electrodes (hygroscopic) – SMAW process – externally painted with aluminum spray paint for high temperatures or wrapped with thin plastic films (PVC) and aluminum foil films used commonly for food protection. The basic premise is that establishing a barrier between the atmosphere and the electrode coating could reduce the effects of high hygroscopicity presented by coatings of low hydrogen, minimizing this way the main source of supply of hydrogen to the fusion pool during welding. It is also expected that the addition of new materials from the electrode coating to the fusion pool would induce metallurgical changes in the deposited metal and, as a consequence, modifications in its mechanical properties. This research dealt with measuring the dissolved hydrogen in the deposited metal after welding with modified electrodes, evaluating the influence of these changes in the produced microstructures and in the mechanical properties of the resulting weld, and comparing the obtained results with the standard welding procedures and with the recently developed waterproof electrodes. The results obtained in most samples welded with modified electrodes showed increased mechanical resistance and increased tenacity due to the increased percentage of acicular ferrite in metal deposited without significant elevation of hardness, when compared with the traditional welding with AWS E7018 electrode and with ELBRÁS BRH4R waterproof electrode. The diffusing hydrogen measured in the modified electrodes was kept inside the parameters defined by international codes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências Médicas, Programa de Pós-Graduação em Ciências Médicas, 2011.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study aimed to compare the fluoride (F-) release pattern of a nanofilled resin-modified glass ionomer cement (GIC) (Ketac N100 - KN) with available GICs used in dental practice (resin-modified GIC - Vitremer - V; conventional GIC - Ketac Molar - KM) and a nanofilled resin composite (Filtek Supreme - RC). Discs of each material (n=6) were placed into 4 mL of deionized water in sealed polyethylene vials and shaken, for 15 days. F- release (μg F-/cm²) was measured each day using a fluoride-ion specific electrode. Cumulative F- release means were statistically analyzed by linear regression analysis. In order to analyze the differences among materials and the influence of time in the daily F- release, 2-way ANOVA test was performed (α=0.05). The linear fits between the cumulative F- release profiles of RC and KM and time were weak. KN and V presented a strong relationship between cumulative F- release and time. There were significant differences between the daily F- release overtime up to the third day only for GICs materials. The daily F- release means for RC were similar overtime. The results indicate that the F- release profile of the nanofilled resin-modified GIC is comparable to the resin-modified GIC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrochemical removals of color and organic load from solutions containing the dye reactive orange 16 (RO16) were performed in an electrochemical flow-cell, using a platinum working electrode. The influence of the process variables flow-rate, such as NaCl concentration, applied potential and solution pH, were studied. The best color removal achieved was 93% (λ = 493 nm) after 60 min at 2.2 V vs. RHE electrolysis, using 1.00 g L-1 NaCl as supporting electrolyte. The rises in the concentration of NaCl and applied potential increased the color removal rate. The best total organic carbon removal (57%) was obtained at 1.8 V, without the separating membrane, indicating that the ideal conditions for the color removal are not necessarily the same as those to remove the total organic carbon. The degradation efficiency decreased with the solution pH decrease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The possibility of using a graphite silicone-rubber composite electrode (GSR) in a differential pulse voltammetric(DPV) procedure for rutin (vitamin P) determination is described. Cyclic voltammograms of rutin presented a reversible pair of oxidation/reduction peaks respectively at 0.411 and 0.390 V (vs. SCE) at the GSR surface in Britton-Robinson(B-R) buffer solution pH 4.0. In DPV after optimization of conditions, an oxidation peak at 0.370 V (vs. SCE) was used to quantitative determination of rutin in B-R buffer solution pH 4.0. In this case a linear dynamic range of 5.0×10-8 to 50.0×10-8 mol L-1 was observed with a detection limit of 1.8×10-8 mol L-1 for the analyte. Recoveries from 94 to 113% were observed. The electrode surface was renewed by polishing after each determination, with a repeatability of 1.09 ± 0.06 µA (n = 10) peak current. Rutin was determined in a pharmaceutical formulation using the proposed electrode and the results agreed with those from an official method within 95% confidence level.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A bare graphite-polyurethane composite was evaluated as an amperometric flow injection detector in the determination of paracetamol (APAP) in pharmaceutical formulations. A linear analytical curve was observed in the 5.00 x 10-5 to 5.00 x 10-3 mol L-1 range with a minimum detectable net concentration of 18.9 µmol L-1 and 180 determinations h-1, after optimization of parameters such as the detection potential, sample loop volume, and carrier solution flow rate. Interference of ascorbic acid was observed, however, it was possible overcome the interference, reaching results that agreed with HPLC within 95% confidence level. These results showed that the graphite-polyurethane composite can be used as an amperometric detector for flow analysis in the determination of APAP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical behavior of fluconazole showed an irreversible oxidation process, with the electrochemical - chemical mechanism being highly dependent on the electrode material. Adsorption of reagent at positive applied potential was observed at Pt electrode while preferential adsorption of the oxidation products was observed at Glassy Carbon surfaces. In pH below 7.0, the anodic current process was intensively decreased. At carbon paste electrode, the fluconazole oxidation current, recorded in phosphate buffer solution (pH 8.0), changed linearly with the fluconazole concentration, Ipa = 5.7×10-5 (mA) × 0.052 [Fluconazol] (μg mL-1), in the range of 48.0 to 250.0 μg mL-1. The detection limit obtained was 6.3 μg mL-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the study of photochemical behavior of polycyclic aromatic hydrocarbons (PAHs), potential pollutants in secondary reactions in aerosols, through Raman spectroscopy compared with its electrochemical behavior. The PAHs studied include pyrene, anthracene, phenanthrene and fluorene. These were adsorbed onto TiO2 and irradiated with ultraviolet light (254 nm). Their electrochemical oxidation was studied by in situ Surface-enhanced Raman Scattering (SERS) and led to the formation of carbonyl-containing products. Oxidized intermediates bearing the C=O group were also formed during photodegradation. The joint analysis of the photodegradation data with those produced by electrochemical means - using spectroscopic techniques for the identification and characterization of the products - revealed the formation of identical products for anthracene, but not for pyrene. A reasonable explanation for this difference in results is that photochemical and electrochemical oxidation reactions proceed via different mechanisms. While photocatalytic degradation over TiO2 is initiated by hydroxyl radicals, electrochemical oxidation is initiated by the direct electron transfer from adsorbed PAH to the electrode, generating PAH cation radicals that undergo subsequent reactions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An alternative technique for the fabrication of disposable electrochemical microcells containing working, reference and auxiliary electrodes on a single device is reported. The procedure is based on thermal-transfer of toner masks onto CD-R (recordable compact discs) gold surfaces to define the layout of the electrodes (contour). In a subsequent step, the layout is manually painted with a permanent marker pen. The unprotected gold surface is conveniently etched (chemical corrosion) and the ink is then easily removed with ethanol, generating gold surfaces without contamination. The final and reproducible area of the electrodes is defined by heat transference of a second toner mask. Silver epoxy is deposited on one of the gold bands which is the satisfactorily used as reference electrode. These microcells were electrochemically characterized by cyclic, linear, and square wave voltammetry, and several electroactive species were used as model systems. The area reproducibility of the electrodes for different microcells was studied and a relative standard deviation better than 1,0% (n = 10) was obtained. Disposable electrochemical microcells were successfully used in analysis of liquid samples with volumes lower than 200 µL and good stability and reproducibility (RSD less than 2.0%) were achieved. These microcells were also evaluated for quantification of paracetamol and dipyrone in pharmaceutical formulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An amperometric lactate biosensor with lactate oxidase immobilized into a Prussian Blue (PB) modified electrode was fabricated. The advantage of using cetyltrimethylammonium bromide (CTAB) in the electrodeposition step of PB films onto glassy carbon surfaces was confirmed taking into account both the stability and sensitivity of the measurements. The biosensor was used in the development of a FIA amperometric method for the determination of lactate. Under optimal operating conditions (pH = 6.9, E = -0.1 V), the linear response of the method was extended up to 0.28 µmol L-1 lactate with a limit of detection of 0.84 mmol L-1. The repeatability of the method for injections of a 0.28 mmol L-1 lactate solution was 2.2 % (n = 18). The usefulness of the method was demonstrated by determining lactate in beer samples and the results were in good agreement with those obtained by using a reference spectrophotometric enzyme method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eletrorretinograma (ERG) é o meio diagnóstico objetivo e não-invasivo para avaliar a função retiniana e detectar precocemente, em várias espécies, lesões nas suas camadas mais externas. As indicações mais comuns para ERG em cães são: avaliação pré-cirúrgica de pacientes com catarata, caracterização de distúrbios que causam cegueira, além de servir como importante modelo para o estudo da distrofia retiniana que acomete o homem. Vários são os fatores que podem alterar o ERG tais como: eletrorretinógrafo, fonte de estimulação luminosa, tipo do eletrodo, tempo de adaptação ao escuro, tamanho pupilar, opacidade de meios e protocolo de sedação ou anestesia; além da espécie, raça e idade. Objetivou-se com este estudo padronizar o ERG para cães submetidos à sedação, seguindo o protocolo da International Society for Clinical Electrophysiology of Vision (ISCEV), utilizando Ganzfeld e eletrodos Burian Allen. Foram realizados 233 eletrorretinogramas em cães, 147 fêmeas e 86 machos, com idades entre um e 14 anos. Dos 233 cães examinados, 100 apresentavam catarata em diferentes estágios de maturação, 72 eram diabéticos e apresentavam catarata madura ou hipermadura, 26 apresentaram eletrorretinograma compatível com degeneração retiniana progressiva, três apresentaram eletrorretinograma compatível com síndrome da degeneração retiniana adquirida subitamente e 32 não apresentaram lesão retiniana capaz de atenuar as respostas do ERG, sendo considerados normais quanto à função retiniana. A sedação foi capaz de produzir boa imobilização do paciente sem rotacionar o bulbo ocular, permitindo adequada estimulação retiniana bilateralmente, com auxílio do Ganzfeld. O sistema eletrodiagnóstico Veris registrou com sucesso e simultaneamente de ambos os olhos, as cinco respostas preconizadas pela ISCEV. Como o ERG de campo total tornou-se exame fundamental na rotina oftalmológica, sua padronização é indispensável quando se objetiva comparar resultados de laboratórios distintos. A confiabilidade e reprodutibilidade deste protocolo foi demonstrada com a obtenção de registros de ótima qualidade utilizando protocolo padrão da ISCEV, eletrorretinógrafo Veris, Ganzfeld e eletrodos Burian Allen nos cães submetidos à sedação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O Transtorno do pânico (TP) é um transtorno mental comum que afeta até 5% da população em algum momento da vida, sendo caracterizada pela presença de ataques de pânico (AP) recorrentes. Constitui uma psicopatologia que pode ser afetada pela privação do sono (PS), relação que ainda é pouco compreendida. Neste contexto, modelos experimentais de AP e de PS são ferramentas úteis na investigação dessa possível correlação, especialmente motivado pela crescente condição de privação de sono, que tem se tornado cada vez mais frequente na sociedade moderna. Assim, este estudo avaliou os efeitos da privação de sono paradoxal (PSP) sobre os limiares dos comportamentos defensivos induzidos por estimulação intracraniana (EI) da MCPD e CS de ratos num modelo experimental de AP, assim como verificou a influência da corticosterona sobre esses limiares. Foram utilizados 160 ratos Wistar machos (300g), organizados em 4 grupos com 40 animais cada, como se segue: Grupo Controle (CTR) submetido à EI, porém sem PSP; Grupo Privação (PRV), submetido à EI e privado por 96 horas; Grupo Privação + Bloqueio da corticosterona (PRB), submetido ao tratamento com metirapona, EI, e privado por 96 horas, e Grupo Controle + Bloqueio da corticosterona (CTB), submetido ao tratamento com metirapona e EI, porém sem privação de sono. Após 10 dias do implante cirúrgico intracraniano de eletrodo na MCPD e CS, os animais passaram por 5 sessões de estimulação, como se segue: 1ª (TRI) considerada triagem - imediatamente antes da privação, 2ª (P48) após 48h de privação, 3ª (P96) após 96h de privação, 4ª (R48) após 48h de retirada da privação e 5ª (R96) após 96h de retirada da privação. As curvas de limiares das respostas individuais de defesa obtidas nas várias sessões de estimulação da MCPD e CS (TRI, P48, P96, R48 e R96) dos ratos foram comparadas entre si, bem como as curvas de limiares de uma dada resposta nos diferentes grupos (CTR, PRV, CTB e PRB). Além disso, os níveis de corticosterona (CORT) foram dosados nas diferentes sessões de EI, e comparadas num mesmo grupo, bem como nos diferentes grupos. No grupo CTR, todos os comportamentos foram iguais em todas as sessões quando comparados à TRI, entretanto, nos animais privados (PRV), o limiar do galope (GLP) reduziu significativamente em R48 e R96, não ocorrendo xix alterações nos demais comportamentos. Em contraste, no grupo PRB, o Trote (TRT) aumentou a partir de P48, enquanto o GLP não foi alterado em nenhuma sessão de EI. Na comparação entre os grupos, em Salto (SLT), Micção (MIC), Exoftalmia (EXO), Imobilidade (IMO), Defecação (DEF), TRT e GLP, não sofreram alterações decorrentes da CORT produzida decorrente da PSP, sugerindo que a corticosterona não altera os comportamentos defensivos característicos do Ataque de Pânico. Em adição, tais resultados sugerem que os efeitos tardios da PSP sobre os limiares de GLP possivelmente se devam a mecanismos neuroquímicos tempo-dependente.