991 resultados para electricity generating cost
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I- 100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
This thesis is a collection of essays about the instrumental use of commitment decisions to facilitate the completion of the European internal electricity market. European policy can shape markets in many ways, two most evident being regulation and competition enforcement. The interplay between these two instruments attracts a lot of scholarly attention. One of the major concerns in the competition vs. regulation debate is the instrumental use of competition rules. It has been observed that competition enforcement is triggered not only as a response to an anticompetitive harm occurring in the market, but that it sometimes becomes a powerful tool in the European Commission’s hands to pursue regulatory goals. This thesis looks for examples of such instrumentalisation in the context of electricity markets and finds that the Commission is very pragmatic in using all the possible instruments it has at hand to push forward its project of creating the internal electricity market. This includes regulation, competition enforcement and all sorts of political pressure. To the extent that commitment decisions accelerate sector-specific regulation and overcome political deadlocks, they contribute to the Commission’s energy policy goals. However, instrumentalisation of competition rules comes at a certain cost to competition policy, energy policy and, most importantly, to electricity markets themselves. Markets might be negatively affected either indirectly, by application of sector-specific regulation or competition policy building on previous commitment decisions, or directly, through the implementation of inadequate commitments in individual cases. Concluding, commitment decisions generally contributed to achieving the policy objectives of the internal electricity market, but their use for that purpose does not come without cost. Given that this cost is ultimately borne by the internal electricity market, the Commission should take a more balanced approach to the instrumental use of commitment decisions so that it does not do more harm than good.
Resumo:
The past decade has seen the energy consumption in servers and Internet Data Centers (IDCs) skyrocket. A recent survey estimated that the worldwide spending on servers and cooling have risen to above $30 billion and is likely to exceed spending on the new server hardware . The rapid rise in energy consumption has posted a serious threat to both energy resources and the environment, which makes green computing not only worthwhile but also necessary. This dissertation intends to tackle the challenges of both reducing the energy consumption of server systems and by reducing the cost for Online Service Providers (OSPs). Two distinct subsystems account for most of IDC’s power: the server system, which accounts for 56% of the total power consumption of an IDC, and the cooling and humidifcation systems, which accounts for about 30% of the total power consumption. The server system dominates the energy consumption of an IDC, and its power draw can vary drastically with data center utilization. In this dissertation, we propose three models to achieve energy effciency in web server clusters: an energy proportional model, an optimal server allocation and frequency adjustment strategy, and a constrained Markov model. The proposed models have combined Dynamic Voltage/Frequency Scaling (DV/FS) and Vary-On, Vary-off (VOVF) mechanisms that work together for more energy savings. Meanwhile, corresponding strategies are proposed to deal with the transition overheads. We further extend server energy management to the IDC’s costs management, helping the OSPs to conserve, manage their own electricity cost, and lower the carbon emissions. We have developed an optimal energy-aware load dispatching strategy that periodically maps more requests to the locations with lower electricity prices. A carbon emission limit is placed, and the volatility of the carbon offset market is also considered. Two energy effcient strategies are applied to the server system and the cooling system respectively. With the rapid development of cloud services, we also carry out research to reduce the server energy in cloud computing environments. In this work, we propose a new live virtual machine (VM) placement scheme that can effectively map VMs to Physical Machines (PMs) with substantial energy savings in a heterogeneous server cluster. A VM/PM mapping probability matrix is constructed, in which each VM request is assigned with a probability running on PMs. The VM/PM mapping probability matrix takes into account resource limitations, VM operation overheads, server reliability as well as energy effciency. The evolution of Internet Data Centers and the increasing demands of web services raise great challenges to improve the energy effciency of IDCs. We also express several potential areas for future research in each chapter.
Resumo:
Electricity markets in the United States presently employ an auction mechanism to determine the dispatch of power generation units. In this market design, generators submit bid prices to a regulation agency for review, and the regulator conducts an auction selection in such a way that satisfies electricity demand. Most regulators currently use an auction selection method that minimizes total offer costs ["bid cost minimization" (BCM)] to determine electric dispatch. However, recent literature has shown that this method may not minimize consumer payments, and it has been shown that an alternative selection method that directly minimizes total consumer payments ["payment cost minimization" (PCM)] may benefit social welfare in the long term. The objective of this project is to further investigate the long term benefit of PCM implementation and determine whether it can provide lower costs to consumers. The two auction selection methods are expressed as linear constraint programs and are implemented in an optimization software package. Methodology for game theoretic bidding simulation is developed using EMCAS, a real-time market simulator. Results of a 30-day simulation showed that PCM reduced energy costs for consumers by 12%. However, this result will be cross-checked in the future with two other methods of bid simulation as proposed in this paper.
Resumo:
A Payment Cost Minimization (PCM) auction has been proposed as an alternative to the Offer Cost Minimization (OCM) auction to be used in wholesale electric power markets with the intention to lower the procurement cost of electricity. Efficiency concerns about this proposal have relied on the assumption of true production cost revelation. Using an experimental approach, I compare the two auctions, strictly controlling for the level of unilateral market power. A specific feature of these complex-offer auctions is that the sellers submit not only the quantities and the minimum prices at which they are willing to sell, but also the start-up fees that are designed to reimburse the fixed start-up costs of the generation plants. I find that both auctions result in start-up fees that are significantly higher than the start-up costs. Overall, the two auctions perform similarly in terms of procurement cost and efficiency. Surprisingly, I do not find a substantial difference between less market power and more market power designs. Both designs result in similar inefficiencies and equally higher procurement costs over the competitive prediction. The PCM auction tends to have lower price volatility than the OCM auction when the market power is minimal but this property vanishes in the designs with market power. These findings lead me to conclude that both the PCM and the OCM auctions do not belong to the class of truth revealing mechanisms and do not easily elicit competitive behavior.
Resumo:
This study of the wholesale electricity market compares the cost-minimizing performance of the auction mechanism currently in place in U.S. markets with the performance of a proposed replacement. The current mechanism chooses an allocation of contracts that minimizes a fictional cost calculated using pay-as-offer pricing. Then suppliers are paid the market clearing price. The proposed mechanism uses the market clearing price in the allocation phase as well as in the payment phase. In concentrated markets, the proposed mechanism outperforms the current mechanism even when strategic behavior by suppliers is taken into account. The advantage of the proposed mechanism increases with increased price competition.
Resumo:
In this paper, we present a depth-color scene modeling strategy for indoors 3D contents generation. It combines depth and visual information provided by a low-cost active depth camera to improve the accuracy of the acquired depth maps considering the different dynamic nature of the scene elements. Accurate depth and color models of the scene background are iteratively built, and used to detect moving elements in the scene. The acquired depth data is continuously processed with an innovative joint-bilateral filter that efficiently combines depth and visual information thanks to the analysis of an edge-uncertainty map and the detected foreground regions. The main advantages of the proposed approach are: removing depth maps spatial noise and temporal random fluctuations; refining depth data at object boundaries, generating iteratively a robust depth and color background model and an accurate moving object silhouette.
Resumo:
El mercado ibérico de futuros de energía eléctrica gestionado por OMIP (“Operador do Mercado Ibérico de Energia, Pólo Português”, con sede en Lisboa), también conocido como el mercado ibérico de derivados de energía, comenzó a funcionar el 3 de julio de 2006. Se analiza la eficiencia de este mercado organizado, por lo que se estudia la precisión con la que sus precios de futuros predicen el precio de contado. En dicho mercado coexisten dos modos de negociación: el mercado continuo (modo por defecto) y la contratación mediante subasta. En la negociación en continuo, las órdenes anónimas de compra y de venta interactúan de manera inmediata e individual con órdenes contrarias, dando lugar a operaciones con un número indeterminado de precios para cada contrato. En la negociación a través de subasta, un precio único de equilibrio maximiza el volumen negociado, liquidándose todas las operaciones a ese precio. Adicionalmente, los miembros negociadores de OMIP pueden liquidar operaciones “Over-The-Counter” (OTC) a través de la cámara de compensación de OMIP (OMIClear). Las cinco mayores empresas españolas de distribución de energía eléctrica tenían la obligación de comprar electricidad hasta julio de 2009 en subastas en OMIP, para cubrir parte de sus suministros regulados. De igual manera, el suministrador de último recurso portugués mantuvo tal obligación hasta julio de 2010. Los precios de equilibrio de esas subastas no han resultado óptimos a efectos retributivos de tales suministros regulados dado que dichos precios tienden a situarse ligeramente sesgados al alza. La prima de riesgo ex-post, definida como la diferencia entre los precios a plazo y de contado en el periodo de entrega, se emplea para medir su eficiencia de precio. El mercado de contado, gestionado por OMIE (“Operador de Mercado Ibérico de la Energía”, conocido tradicionalmente como “OMEL”), tiene su sede en Madrid. Durante los dos primeros años del mercado de futuros, la prima de riesgo media tiende a resultar positiva, al igual que en otros mercados europeos de energía eléctrica y gas natural. En ese periodo, la prima de riesgo ex-post tiende a ser negativa en los mercados de petróleo y carbón. Los mercados de energía tienden a mostrar niveles limitados de eficiencia de mercado. La eficiencia de precio del mercado de futuros aumenta con el desarrollo de otros mecanismos coexistentes dentro del mercado ibérico de electricidad (conocido como “MIBEL”) –es decir, el mercado dominante OTC, las subastas de centrales virtuales de generación conocidas en España como Emisiones Primarias de Energía, y las subastas para cubrir parte de los suministros de último recurso conocidas en España como subastas CESUR– y con una mayor integración de los mercados regionales europeos de energía eléctrica. Se construye un modelo de regresión para analizar la evolución de los volúmenes negociados en el mercado continuo durante sus cuatro primeros años como una función de doce indicadores potenciales de liquidez. Los únicos indicadores significativos son los volúmenes negociados en las subastas obligatorias gestionadas por OMIP, los volúmenes negociados en el mercado OTC y los volúmenes OTC compensados por OMIClear. El número de creadores de mercado, la incorporación de agentes financieros y compañías de generación pertenecientes a grupos integrados con suministradores de último recurso, y los volúmenes OTC compensados por OMIClear muestran una fuerte correlación con los volúmenes negociados en el mercado continuo. La liquidez de OMIP está aún lejos de los niveles alcanzados por los mercados europeos más maduros (localizados en los países nórdicos (Nasdaq OMX Commodities) y Alemania (EEX)). El operador de mercado y su cámara de compensación podrían desarrollar acciones eficientes de marketing para atraer nuevos agentes activos en el mercado de contado (p.ej. industrias consumidoras intensivas de energía, suministradores, pequeños productores, compañías energéticas internacionales y empresas de energías renovables) y agentes financieros, captar volúmenes del opaco OTC, y mejorar el funcionamiento de los productos existentes aún no líquidos. Resultaría de gran utilidad para tales acciones un diálogo activo con todos los agentes (participantes en el mercado, operador de mercado de contado, y autoridades supervisoras). Durante sus primeros cinco años y medio, el mercado continuo presenta un crecimento de liquidez estable. Se mide el desempeño de sus funciones de cobertura mediante la ratio de posición neta obtenida al dividir la posición abierta final de un contrato de derivados mensual entre su volumen acumulado en la cámara de compensación. Los futuros carga base muestran la ratio más baja debido a su buena liquidez. Los futuros carga punta muestran una mayor ratio al producirse su menor liquidez a través de contadas subastas fijadas por regulación portuguesa. Las permutas carga base liquidadas en la cámara de compensación ubicada en Madrid –MEFF Power, activa desde el 21 de marzo de 2011– muestran inicialmente valores altos debido a bajos volúmenes registrados, dado que esta cámara se emplea principalmente para vencimientos pequeños (diario y semanal). Dicha ratio puede ser una poderosa herramienta de supervisión para los reguladores energéticos cuando accedan a todas las transacciones de derivados en virtud del Reglamento Europeo sobre Integridad y Transparencia de los Mercados de Energía (“REMIT”), en vigor desde el 28 de diciembre de 2011. La prima de riesgo ex-post tiende a ser positiva en todos los mecanismos (futuros en OMIP, mercado OTC y subastas CESUR) y disminuye debido a la curvas de aprendizaje y al efecto, desde el año 2011, del precio fijo para la retribución de la generación con carbón autóctono. Se realiza una comparativa con los costes a plazo de generación con gas natural (diferencial “clean spark spread”) obtenido como la diferencia entre el precio del futuro eléctrico y el coste a plazo de generación con ciclo combinado internalizando los costes de emisión de CO2. Los futuros eléctricos tienen una elevada correlación con los precios de gas europeos. Los diferenciales de contratos con vencimiento inmediato tienden a ser positivos. Los mayores diferenciales se dan para los contratos mensuales, seguidos de los trimestrales y anuales. Los generadores eléctricos con gas pueden maximizar beneficios con contratos de menor vencimiento. Los informes de monitorización por el operador de mercado que proporcionan transparencia post-operacional, el acceso a datos OTC por el regulador energético, y la valoración del riesgo regulatorio pueden contribuir a ganancias de eficiencia. Estas recomendaciones son también válidas para un potencial mercado ibérico de futuros de gas, una vez que el hub ibérico de gas –actualmente en fase de diseño, con reuniones mensuales de los agentes desde enero de 2013 en el grupo de trabajo liderado por el regulador energético español– esté operativo. El hub ibérico de gas proporcionará transparencia al atraer más agentes y mejorar la competencia, incrementando su eficiencia, dado que en el mercado OTC actual no se revela precio alguno de gas. ABSTRACT The Iberian Power Futures Market, managed by OMIP (“Operador do Mercado Ibérico de Energia, Pólo Português”, located in Lisbon), also known as the Iberian Energy Derivatives Market, started operations on 3 July 2006. The market efficiency, regarding how well the future price predicts the spot price, is analysed for this energy derivatives exchange. There are two trading modes coexisting within OMIP: the continuous market (default mode) and the call auction. In the continuous trading, anonymous buy and sell orders interact immediately and individually with opposite side orders, generating trades with an undetermined number of prices for each contract. In the call auction trading, a single price auction maximizes the traded volume, being all trades settled at the same price (equilibrium price). Additionally, OMIP trading members may settle Over-the-Counter (OTC) trades through OMIP clearing house (OMIClear). The five largest Spanish distribution companies have been obliged to purchase in auctions managed by OMIP until July 2009, in order to partly cover their portfolios of end users’ regulated supplies. Likewise, the Portuguese last resort supplier kept that obligation until July 2010. The auction equilibrium prices are not optimal for remuneration purposes of regulated supplies as such prices seem to be slightly upward biased. The ex-post forward risk premium, defined as the difference between the forward and spot prices in the delivery period, is used to measure its price efficiency. The spot market, managed by OMIE (Market Operator of the Iberian Energy Market, Spanish Pool, known traditionally as “OMEL”), is located in Madrid. During the first two years of the futures market, the average forward risk premium tends to be positive, as it occurs with other European power and natural gas markets. In that period, the ex-post forward risk premium tends to be negative in oil and coal markets. Energy markets tend to show limited levels of market efficiency. The price efficiency of the Iberian Power Futures Market improves with the market development of all the coexistent forward contracting mechanisms within the Iberian Electricity Market (known as “MIBEL”) – namely, the dominant OTC market, the Virtual Power Plant Auctions known in Spain as Energy Primary Emissions, and the auctions catering for part of the last resort supplies known in Spain as CESUR auctions – and with further integration of European Regional Electricity Markets. A regression model tracking the evolution of the traded volumes in the continuous market during its first four years is built as a function of twelve potential liquidity drivers. The only significant drivers are the traded volumes in OMIP compulsory auctions, the traded volumes in the OTC market, and the OTC cleared volumes by OMIClear. The amount of market makers, the enrolment of financial members and generation companies belonging to the integrated group of last resort suppliers, and the OTC cleared volume by OMIClear show strong correlation with the traded volumes in the continuous market. OMIP liquidity is still far from the levels reached by the most mature European markets (located in the Nordic countries (Nasdaq OMX Commodities) and Germany (EEX)). The market operator and its clearing house could develop efficient marketing actions to attract new entrants active in the spot market (e.g. energy intensive industries, suppliers, small producers, international energy companies and renewable generation companies) and financial agents as well as volumes from the opaque OTC market, and to improve the performance of existing illiquid products. An active dialogue with all the stakeholders (market participants, spot market operator, and supervisory authorities) will help to implement such actions. During its firs five and a half years, the continuous market shows steady liquidity growth. The hedging performance is measured through a net position ratio obtained from the final open interest of a month derivatives contract divided by its accumulated cleared volume. The base load futures in the Iberian energy derivatives exchange show the lowest ratios due to good liquidity. The peak futures show bigger ratios as their reduced liquidity is produced by auctions fixed by Portuguese regulation. The base load swaps settled in the clearing house located in Spain – MEFF Power, operating since 21 March 2011, with a new denomination (BME Clearing) since 9 September 2013 – show initially large values due to low registered volumes, as this clearing house is mainly used for short maturity (daily and weekly swaps). The net position ratio can be a powerful oversight tool for energy regulators when accessing to all the derivatives transactions as envisaged by European regulation on Energy Market Integrity and Transparency (“REMIT”), in force since 28 December 2011. The ex-post forward risk premium tends to be positive in all existing mechanisms (OMIP futures, OTC market and CESUR auctions) and diminishes due to the learning curve and the effect – since year 2011 – of the fixed price retributing the indigenous coal fired generation. Comparison with the forward generation costs from natural gas (“clean spark spread”) – obtained as the difference between the power futures price and the forward generation cost with a gas fired combined cycle plant taking into account the CO2 emission rates – is also performed. The power futures are strongly correlated with European gas prices. The clean spark spreads built with prompt contracts tend to be positive. The biggest clean spark spreads are for the month contract, followed by the quarter contract and then by the year contract. Therefore, gas fired generation companies can maximize profits trading with contracts of shorter maturity. Market monitoring reports by the market operator providing post-trade transparency, OTC data access by the energy regulator, and assessment of the regulatory risk can contribute to efficiency gains. The same recommendations are also valid for a potential Iberian gas futures market, once an Iberian gas hub – currently in a design phase, with monthly meetings amongst the stakeholders in a Working Group led by the Spanish energy regulatory authority since January 2013 – is operating. The Iberian gas hub would bring transparency attracting more shippers and improving competition and thus its efficiency, as no gas price is currently disclosed in the existing OTC market.
Resumo:
Energía termosolar (de concentración) es uno de los nombres que hacen referencia en español al término inglés “concentrating solar power”. Se trata de una tecnología basada en la captura de la potencia térmica de la radiación solar, de forma que permita alcanzar temperaturas capaces de alimentar un ciclo termodinámico convencional (o avanzado); el futuro de esta tecnología depende principalmente de su capacidad para concentrar la radiación solar de manera eficiente y económica. La presente tesis está orientada hacia la resolución de ciertos problemas importantes relacionados con este objetivo. La mencionada necesidad de reducir costes en la concentración de radiación solar directa, asegurando el objetivo termodinámico de calentar un fluido hasta una determinada temperatura, es de vital importancia. Los colectores lineales Fresnel han sido identificados en la literatura científica como una tecnología con gran potencial para alcanzar esta reducción de costes. Dicha tecnología ha sido seleccionada por numerosas razones, entre las que destacan su gran libertad de diseño y su actual estado inmaduro. Con el objetivo de responder a este desafío se desarrollado un detallado estudio de las propiedades ópticas de los colectores lineales Fresnel, para lo cual se han utilizado métodos analíticos y numéricos de manera combinada. En primer lugar, se han usado unos modelos para la predicción de la localización y la irradiación normal directa del sol junto a unas relaciones analíticas desarrolladas para estudiar el efecto de múltiples variables de diseño en la energía incidente sobre los espejos. Del mismo modo, se han obtenido analíticamente los errores debidos al llamado “off-axis aberration”, a la apertura de los rayos reflejados en los espejos y a las sombras y bloqueos entre espejos. Esto ha permitido la comparación de diferentes formas de espejo –planos, circulares o parabólicos–, así como el diseño preliminar de la localización y anchura de los espejos y receptor sin necesidad de costosos métodos numéricos. En segundo lugar, se ha desarrollado un modelo de trazado de rayos de Monte Carlo con el objetivo de comprobar la validez del estudio analítico, pero sobre todo porque este no es preciso en el estudio de la reflexión en espejos. El código desarrollado está específicamente ideado para colectores lineales Fresnel, lo que ha permitido la reducción del tiempo de cálculo en varios órdenes de magnitud en comparación con un programa comercial más general. Esto justifica el desarrollo de un nuevo código en lugar de la compra de una licencia de otro programa. El modelo ha sido usado primeramente para comparar la intensidad de flujo térmico y rendimiento de colectores Fresnel, con y sin reflector secundario, con los colectores cilíndrico parabólicos. Finalmente, la conjunción de los resultados obtenidos en el estudio analítico con el programa numérico ha sido usada para optimizar el campo solar para diferentes orientaciones –Norte-Sur y Este-Oeste–, diferentes localizaciones –Almería y Aswan–, diferentes inclinaciones hacia el Trópico –desde 0 deg hasta 32 deg– y diferentes mínimos de intensidad del flujo en el centro del receptor –10 kW/m2 y 25 kW/m2–. La presente tesis ha conducido a importantes descubrimientos que deben ser considerados a la hora de diseñar un campo solar Fresnel. En primer lugar, los espejos utilizados no deben ser plano, sino cilíndricos o parabólicos, ya que los espejos curvos implican mayores concentraciones y rendimiento. Por otro lado, se ha llegado a la conclusión de que la orientación Este-Oeste es más propicia para localizaciones con altas latitudes, como Almería, mientras que en zonas más cercanas a los trópicos como Aswan los campos Norte-Sur conducen a mayores rendimientos. Es de destacar que la orientación Este-Oeste requiere aproximadamente la mitad de espejos que los campos Norte-Sur, puediendo estar inclinados hacia los Trópicos para mejorar el rendimiento, y que alcanzan parecidos valores de intensidad térmica en el receptor todos los días a mediodía. Sin embargo, los campos con orientación Norte-Sur permiten un flujo más constante a lo largo de un día. Por último, ha sido demostrado que el uso de diseños pre-optimizados analíticamente, con anchura de espejos y espaciado entre espejos variables a lo ancho del campo, pueden implicar aumentos de la energía generada por metro cuadrado de espejos de hasta el 6%. El rendimiento óptico anual de los colectores cilíndrico parabólicos es 23 % mayor que el rendimiento de los campos Fresnel en Almería, mientras que la diferencia es de solo 9 % en Aswan. Ello implica que, para alcanzar el mismo precio de electricidad que la tecnología de referencia, la reducción de costes de instalación por metro cuadrado de espejo debe estar entre el 10 % y el 25 %, y que los colectores lineales Fresnel tienen más posibilidades de ser desarrollados en zonas de bajas latitudes. Como consecuencia de los estudios desarrollados en esta tesis se ha patentado un sistema de almacenamiento que tiene en cuenta la variación del flujo térmico en el receptor a lo largo del día, especialmente para campos con orientación Este-Oeste. Este invento permitiría el aprovechamiento de la energía incidente durante más parte del año, aumentando de manera apreciable los rendimientos óptico y térmico. Abstract Concentrating solar power is the common name of a technology based on capturing the thermal power of solar radiation, in a suitable way to reach temperatures able to activate a conventional (or advanced) thermodynamic cycle to generate electricity; this quest mainly depends on our ability to concentrate solar radiation in a cheap and efficient way. The present thesis is focused to highlight and help solving some of the important issues related to this problem. The need of reducing costs in concentrating the direct solar radiation, but without jeopardizing the thermodynamic objective of heating a fluid up to the required temperature, is of prime importance. Linear Fresnel collectors have been identified in the scientific literature as a technology with high potential to reach this cost reduction. This technology has been selected because of a number of reasons, particularly the degrees of freedom of this type of concentrating configuration and its current immature state. In order to respond to this challenge, a very detailed exercise has been carried out on the optical properties of linear Fresnel collectors. This has been done combining analytic and numerical methods. First, the effect of the design variables on the ratio of energy impinging onto the reflecting surface has been studied using analytically developed equations, together with models that predict the location and direct normal irradiance of the sun at any moment. Similarly, errors due to off-axis aberration, to the aperture of the reflected energy beam and to shading and blocking effects have been obtained analytically. This has allowed the comparison of different shapes of mirrors –flat, cylindrical or parabolic–, as well as a preliminary optimization of the location and width of mirrors and receiver with no need of time-consuming numerical models. Second, in order to prove the validity of the analytic results, but also due to the fact that the study of the reflection process is not precise enough when using analytic equations, a Monte Carlo Ray Trace model has been developed. The developed code is designed specifically for linear Fresnel collectors, which has reduced the computing time by several orders of magnitude compared to a wider commercial software. This justifies the development of the new code. The model has been first used to compare radiation flux intensities and efficiencies of linear Fresnel collectors, both multitube receiver and secondary reflector receiver technologies, with parabolic trough collectors. Finally, the results obtained in the analytic study together with the numeric model have used in order to optimize the solar field for different orientations –North-South and East-West–, different locations –Almería and Aswan–, different tilts of the field towards the Tropic –from 0 deg to 32 deg– and different flux intensity minimum requirements –10 kW/m2 and 25 kW/m2. This thesis work has led to several important findings that should be considered in the design of Fresnel solar fields. First, flat mirrors should not be used in any case, as cylindrical and parabolic mirrors lead to higher flux intensities and efficiencies. Second, it has been concluded that, in locations relatively far from the Tropics such as Almería, East-West embodiments are more efficient, while in Aswan North- South orientation leads to a higher annual efficiency. It must be noted that East-West oriented solar fields require approximately half the number of mirrors than NS oriented fields, can be tilted towards the Equator in order to increase the efficiency and attain similar values of flux intensity at the receiver every day at midday. On the other hand, in NS embodiments the flux intensity is more even during each single day. Finally, it has been proved that the use of analytic designs with variable shift between mirrors and variable width of mirrors across the field can lead to improvements in the electricity generated per reflecting surface square meter up to 6%. The annual optical efficiency of parabolic troughs has been found to be 23% higher than the efficiency of Fresnel fields in Almería, but it is only around 9% higher in Aswan. This implies that, in order to attain the same levelized cost of electricity than parabolic troughs, the required reduction of installation costs per mirror square meter is in the range of 10-25%. Also, it is concluded that linear Fresnel collectors are more suitable for low latitude areas. As a consequence of the studies carried out in this thesis, an innovative storage system has been patented. This system takes into account the variation of the flux intensity along the day, especially for East-West oriented solar fields. As a result, the invention would allow to exploit the impinging radiation along longer time every day, increasing appreciably the optical and thermal efficiencies.
Resumo:
In this paper we present a solution for building a better strategy to take part in external electricity markets. For an optimal strategy development, both the internal system costs as well as the future values of the series of electricity prices in external markets need to be known. But in practice, the real problems that must be faced are that both future electricity prices and costs are unknown. Thus, the first ones must be modeled and forecasted and the costs must be calculated. Our methodology for building an optimal strategy consists of three steps: The first step is modeling and forecasting market prices in external systems. The second step is the cost calculation on internal system taking into account the expected prices in the first step. The third step is based on the results of the previous steps, and consists of preparing the bids for external markets. The main goal is to reduce consumers' costs unlike many others that are oriented to increase GenCo's profits.
Resumo:
Energy storage at low maintenance cost is one of the key challenges for generating electricity from the solar energy. This paper presents the theoretical analysis (verified by CFD) of the night time performance of a recently proposed conceptual system that integrates thermal storage (via phase change materials) and thermophotovoltaics for power generation. These storage integrated solar thermophotovoltaic (SISTPV) systems are attractive owing to their simple design (no moving parts) and modularity compared to conventional Concentrated Solar Power (CSP) technologies. Importantly, the ability of high temperature operation of these systems allows the use of silicon (melting point of 1680 K) as the phase change material (PCM). Silicon's very high latent heat of fusion of 1800 kJ/kg and low cost ($1.70/kg), makes it an ideal heat storage medium enabling for an extremely high storage energy density and low weight modular systems. In this paper, the night time operation of the SISTPV system optimised for steady state is analysed. The results indicate that for any given PCM length, a combination of small taper ratio and large inlet hole-to-absorber area ratio are essential to increase the operation time and the average power produced during the night time. Additionally, the overall results show that there is a trade-off between running time and the average power produced during the night time. Average night time power densities as high as 30 W/cm(2) are possible if the system is designed with a small PCM length (10 cm) to operate just a few hours after sun-set, but running times longer than 72 h (3 days) are possible for larger lengths (50 cm) at the expense of a lower average power density of about 14 W/cm(2). In both cases the steady state system efficiency has been predicted to be about 30%. This makes SISTPV systems to be a versatile solution that can be adapted for operation in a broad range of locations with different climate conditions, even being used off-grid and in space applications.
Resumo:
La presente tesis doctoral, “Aprovechamiento térmico de residuos estériles de carbón para generación eléctrica mediante tecnologías de combustión y gasificación eficientes y con mínimo impacto ambiental”, desarrolla la valorización energética de los residuos del carbón, estériles de carbón, producidos durante las etapas de extracción y lavado del carbón. El sistema energético se encuentra en una encrucijada, estamos asistiendo a un cambio en el paradigma energético y, en concreto, en el sector de la generación eléctrica. Se precipita un cambio en la generación y el consumo eléctricos. Una mayor concienciación por la salud está forzando la contención y eliminación de agentes contaminantes que se generan por la utilización de combustibles fósiles de la forma en la que se viene haciendo. Aumenta la preocupación por el cambio climático y por contener en 2°C el aumento de la temperatura de la Tierra para final de este siglo, circunstancia que está impulsando el desarrollo e implantación definitiva de tecnología de control y reducción de emisiones CO2. Generar electricidad de una manera sostenible se está convirtiendo en una obligación. Esto se materializa en generar electricidad respetando el medioambiente, de una forma eficiente en la utilización de los recursos naturales y a un coste competitivo, pensando en el desarrollo de la sociedad y en el beneficio de las personas. En la actualidad, el carbón es la principal fuente de energía utilizada para generar electricidad, y su empleo presenta la forma de energía más barata para mejorar el nivel de vida de cualquier grupo y sociedad. Además, se espera que el carbón siga presente en el mix de generación eléctrica, manteniendo una significativa presencia y extrayéndose en elevadas cantidades. Pero la producción de carbón lleva asociada la generación de un residuo, estéril, que se produce durante la extracción y el lavado del mineral de carbón. Durante décadas se ha estudiado la posibilidad de utilizar el estéril y actualmente se utiliza, en un limitado porcentaje, en la construcción de carreteras, terraplenes y rellenos, y en la producción de algunos materiales de construcción. Esta tesis doctoral aborda la valorización energética del estéril, y analiza el potencial aprovechamiento del residuo para generar electricidad, en una instalación que integre tecnología disponible para minimizar el impacto medioambiental. Además, persigue aprovechar el significativo contenido en azufre que presenta el estéril para producir ácido sulfúrico (H2SO4) como subproducto de la instalación, un compuesto químico muy demandado por la industria de los fertilizantes y con multitud de aplicaciones en otros mercados. Se ha realizado el análisis de caracterización del estéril, los parámetros significativos y los valores de referencia para su empleo como combustible, encontrándose que su empleo como combustible para generar electricidad es posible. Aunque en España se lleva extrayendo carbón desde principios del siglo XVIII, se ha evaluado para un período más reciente la disponibilidad del recurso en España y la normativa existente que condiciona su aplicación en el territorio nacional. Para el período evaluado, se ha calculado que podrían estar disponibles más de 68 millones de toneladas de estéril susceptibles de ser valorizados energéticamente. Una vez realizado el análisis de la tecnología disponible y que podría considerarse para emplear el estéril como combustible, se proponen cuatro configuraciones posibles de planta, tres de ellas basadas en un proceso de combustión y una de ellas en un proceso de gasificación. Tras evaluar las cuatro configuraciones por su interés tecnológico, innovador y económico, se desarrolla el análisis conceptual de una de ellas, basada en un proceso de combustión. La instalación propuesta tiene una capacidad de 65 MW y emplea como combustible una mezcla de carbón y estéril en relación 20/80 en peso. La instalación integra tecnología para eliminar en un 99,8% el SO2 presente en el gas de combustión y en más de un 99% las partículas generadas. La instalación incorpora una unidad de producción de H2SO4, capaz de producir 18,5 t/h de producto, y otra unidad de captura para retirar un 60% del CO2 presente en la corriente de gases de combustión, produciendo 48 tCO2/h. La potencia neta de la planta es 49,7 MW. Se ha calculado el coste de inversión de la instalación, y su cálculo resulta en un coste de inversión unitario de 3.685 €/kW. ABSTRACT The present doctoral thesis, “Thermal utilisation of waste coal for electricity generation by deployment of efficient combustion and gasification technologies with minimum environmental impact”, develops an innovative waste-to-energy concept of waste coals produced during coal mining and washing. The energy system is at a dilemma, we are witnessing a shift in the energy paradigm and specifically in the field of electricity generation. A change in the generation and electrical consumption is foreseen. An increased health consciousness is forcing the containment and elimination of pollutants that are generated by the use of fossil fuels in the way that is being done. Increasing concern about climate change and to contain the rise of global temperature by 2°C by the end of this century, is promoting the development and final implementation of technology to control and reduce the CO2 emission. Electricity generation in a sustainable manner is becoming an obligation. This concept materialised in generating electricity while protecting the environment and deployment of natural resources at a competitive cost, considering the development of society and people´s benefit. Currently, coal is the main source of energy employ to generate electricity, and its use represents the most cost competitive form of energy to increase the standard of living of any group or society. Moreover, coal will keep playing a key role in the global electricity generation mix, maintaining a significant presence and being extracting in large amounts. However, coal production implies the production of waste, termed waste coal or culm in Pennsylvania anthracite extraction, produced during coal mining and coal washing activities. During the last decades, the potential use of waste coal has been studied, and currently, in a limited amount, waste coal is used in roads construction, embankments and fillings, and to produce some construction materials. This doctoral thesis evaluates the waste to energy of waste coals and assesses its potential use to generate electricity, implementing available technology to minimise the environment impact. Additionally, it pursues the significant advantage that presents sulphur content in waste coal to produce sulphuric acid (H2SO4) as a byproduct of the waste-to-energy process, a chemical compound highly demanded by the fertiliser industry and many applications in other markets. It analyses the characteristics of waste coal, and assesses the significant parameters and reference values for its use as fuel, being its fuel use for electricity generation very possible. While mining coal is taking place in Spain since the 1700s, it has been evaluated for a more recent period the waste coal available in Spain and the existing legislation that affects its application and deploy to generate electricity in the country. For the evaluation period has been calculated that may be available more than 68 million tons of waste coal that can be waste-toenergy. The potential available technology to deploy waste coal as fuel has been evaluated and assessed. After considering this, the doctoral thesis proposes four innovative alternatives of facility configuration, three of them based on a combustion process and one in a gasification process. After evaluating the four configurations for its technological, innovative and economic interest, the conceptual analysis of one of alternatives, based on a combustion process, takes place. The proposed alternative facility developed has a capacity of 65 MW, using as fuel a mixture of coal and waste coal 80/20 by weight. The facility comprises technology to remove 99.8% SO2 present in the flue gas and more than 99% of the particles. The facility includes a unit capable of producing 18.5 t/h of H2SO4, and another capture facility, removing 60% of CO2 present in the flue gas stream, producing 48 tCO2/h. The net capacity of the power station is 49.7 MW. The facility unitary cost of investment is 3,685 €/kW.
Resumo:
Linear Fresnel collectors are identified as a technology that should play a main role in order to reduce cost of Concentrating Solar Power. An optical and thermal analysis of the different blocks of the solar power plant is carried out, where Fresnel arrays are compared with the most extended linear technology: parabolic trough collectors. It is demonstrated that the optical performance of Fresnel array is very close to that of PTC, with similar values of maximum flux intensities. In addition, if the heat carrier fluid flows in series by the tubes of the receiver, relatively high thermal efficiencies are achieved. Thus, an annual solar to electricity efficiency of 19% is expected, which is similar to the state of the art in PTCs; this is done with a reduction of costs, thanks to lighter structures, that drives to an estimation of LCOE of around 6.5 c€/kWh.
Resumo:
Given the complex structure of electricity tariffs and their steady growth in Spanish, we've studied its effect over the operating costs of the wastewater treatment plants (WWTP), concluding that in the last three years the revisions of electricity rates have meant increases in electricity costs of 64.5% in the rate 3.1.A and 79.1% in the rate 6.1. This has caused the cost of electricity, which was the most important, has increased from a 44% of total operating costs in the year 2009, to more than a 56% in the year 2012.