986 resultados para dot-ELISA
Resumo:
The Lanczos algorithm is appreciated in many situations due to its speed. and economy of storage. However, the advantage that the Lanczos basis vectors need not be kept is lost when the algorithm is used to compute the action of a matrix function on a vector. Either the basis vectors need to be kept, or the Lanczos process needs to be applied twice. In this study we describe an augmented Lanczos algorithm to compute a dot product relative to a function of a large sparse symmetric matrix, without keeping the basis vectors.
Resumo:
A blocking ELISA targeting an immunodominant West Nile epitope on the West Nile Virus NS1 protein was assessed for the detection of West Nile-specific antibodies in blood samples collected from 584 sentinel chickens and 238 wild birds collected in-New Jersey from May-December 2000. Ten mallard ducks (Anas platyrhynchos) experimentally infected with West Nile virus and six uninfected controls were also tested. The ELISA proved specific in detecting WNV antibodies in 9/10 chickens and 4/4 wild birds previously confirmed as positive by Plaque Reduction Neutralization test (PRNT) at the Center for Disease Control, Division of Vector Borne Diseases, Fort Collins, CO, USA (CDC). Nine out of the ten experimentally infected mallard ducks also tested positive for WN antibodies in the blocking ELISA, while 6/6 uninfected controls did not. Additionally, 1705 wild birds, collected in New Jersey from December 2000-November 2001 and Long Island, New York between November 1999 and August 2001 were also tested for WN antibodies by the blocking ELISA. These tests identified 30 positive specimens, 12 of which had formalin-fixed tissues available to allow detection of WN specific viral antigen in various tissues by WNV-specific immunohistochemistry. Our results indicate that rapid and specific detection of antibodies to WN virus in sera from a range of avian species by blocking ELISA is an effective strategy for WN Virus surveillance in avian hosts. In combination with detection of WN-specific antigens in tissues by immunohistochemistry (IHC) the blocking ELISA will also be useful for confirming WN infection in diseased birds.
Resumo:
We investigate coherent electron transport through a parallel circuit of two quantum dots (QDs), each of which has a single tunable. energy level. Electrons tunnelling via each dot from the left lead interfere with each other at the right lead. It is shown that due to the quantum interference of tunnelling electrons the double QD device is magnetically polarized by coherent circulation of electrons on the closed path through the dots and the leads. By varying the energy level of each dot one can make the magnetic states of the device be up-, non- or down-polarized. It is shown that for experimentally accessible temperatures and applied biases the magnetic polarization currents Should be sufficiently large to observe with current nanotechnology.
Resumo:
O desempenho do ensaio por enzimas imuno-adsorvidas (ELISA), mediante o emprego de conjuntos de reativos produzidos em escala comercial, para determinação de aflatoxina, foi avaliado em condições experimentais, através de análises repetidas, em amostras de leite em pó reconstituído contaminadas com concentrações conhecidas da fração M1 da toxina. Para os níveis de 0,10; 0,20; 0,50; e, 1,00 ng/ml, os percentuais de recuperação foram: 83,0%; 87,5%; 103,0%; e, 111,8%, respectivamente. O desvio-padrão relativo, para as referidas concentrações, foi, respectivamente, 65,5%; 31,8%; 10,9% e 13,6% (n=10, para cada nível de contaminação). Os resultados obtidos demonstram que o método é apropriado para pesquisas e levantamentos sobre a ocorrência de aflatoxina M1 em leite, sobretudo nas faixas de concentração entre 0,20 - 1,00 ng/ml.
Resumo:
One of the main difficulties related to the detection of the Hepatitis Delta Virus (HDV) antigen and antibody has been the source of the needed HD antigen since HDV containing human and animal livers are very difficult to obtain and since yield is low. This fact prompted us to try to use the serum of patients in the acute phase of HDV infection as a source of HDAg and turn to enzyme immunoassays (EIA) instead of RIA for the sake of easiness and economy in the amount of HDAg needed. The antigen for EIA was obtained from patients during the acute phase of HDV infection and the antibody from patients who have been carriers for many years. For the detection of the antigen, a sandwich type method was employed, whereas for the antibody a competition assay was developed. In order to assess the relative specificity and sensibility of the test, the antibody assay was compared to a commercial RIA (C. RIA, Abbott) and to a non-commercial RIA (NC RIA). Forty-two sera were tested by the two methods and only in two cases discrepant results were obtained. Its is concluded that: 1) sera from patients in the acute and chronic phases of HDV infection can be used as source of both antigen and antibody, for immunoassays; 2) EIA and RIA have comparable relative specificity and sensibility and 3) EIA is easier to perform, cheaper, non-hazardous, has a longer shelf-life and saves scarce HDAg.
Resumo:
Foi avaliado o teste imunoenzimático (ELISA), para detecção de anticorpos da classe IgM na leptospirose humana. Nas amostras de soros analisadas, o teste ELISA demonstrou ser mais sensível, específico e precoce, quando comparado ao teste de soroaglutinação microscópica. A análise dos resultados obtidos nesta avaliação demonstra que o teste ELISA permite detectar níveis baixos de anticorpos circulantes, e também anticorpos não aglutinantes. não detectáveis através do teste de soroaglutinação microscópica.
Resumo:
Sera from 472 Brazilian subjects, confirmed to be either positive or negative for HIV antibodies and comprising the total clinical spectrum of HIV infection, were utilized in the evaluation of six commercially available enzyme-linked immunosorbent assays (ELISA), as well as of four alternative assays, namely indirect immunofluorescence (IIF), passive hemagglutination (PHA), dot blot and Karpas AIDS cell test. The sensitivities ranged from 100% (Abbott and Roche ELISA) to 84.2% (PHA) and the specificities ranged from 99.3% (IIF) to 80.2% (PHA). The sensitivity and specificity of the PHA and the sensitivity of the Karpas cell test were significantly lower than those of the other tests. Although the IFF and dot blot had good sensitivities and specificities, the six ELISA were more attractive than those tests when other parameters such as ease of reading and duration of assay were considered.
Resumo:
Comunicamos nuestra experiencia con la aplicación del inmunoensayo enzimático al diagnóstico serológico de Plasmodium vivax con antígeno homólogo. Este se obtuvo a partir de una muestra de sangre de un paciente y luego de lisar los glóbulos rojos con detergente (NP-40). En un "pool" conformado con 11 sueros de pacientes con malaria por P. vivax se encontraron anticuerpos de las clases IgM, IgG e IgA. Se introdujo además la proteína A como sonda secundaria para determinar la respuesta anti-P. vivax en una muestra de 30 sueros de pacientes con un primer episodio palúdico. Se encontró un 93% de correlación con el diagnóstico parasitológico y la prueba resultó específica y reproducible.
Resumo:
Realizou-se estudo comparativo de diferentes sorotipos de Leptospira interrogans utilizados na preparação de antígenos empregados no teste ELISA, para a detecção de anticorpos da classe IgM, em amostras de soro na fase precoce e tardia da leptospirose humana. Foram utilizados dez sorotipos, escolhidos entre os que apresentaram maior reatividade na soroaglutinação microscópica (SAM), na cidade de São Paulo. Os cinco sorotipos que apresentaram melhores resultados individualmente no teste ELISA-IgM (canicola, hebdomadis, icterohaemorrhagiae, cynopteri e brasiliensis), foram também estudados em mistura antigênica. Os antígenos não tratados apresentaram maior reatividade do que os antígenos tratados com Triton X - 100 (4%) à temperatura de 50ºC, durante 4 horas. O teste ELISA-IgM empregando os sorotipos não tratados, isoladamente, e em mistura antigênica, mostrou-se altamente sensível, podendo ser empregado como teste de triagem para o diagnóstico precoce da leptospirose humana. Outra aplicação do teste é permitir a detecção do início de situações epidêmicas ou de surtos, possibilitando acionar medidas de vigilância epidemiológica.
Resumo:
Le test ELISA-TÉTANOS (Biosys, France) a été utilisé pour le titrage des anti-corps tétaniques (sensibilité = 0,0025 UI/ml) en sérums humains de donneurs de sang, 566 hommes et 108 femmes, âges de 18 à 58 ans, moyenne de 29 ans, provenant de São Paulo, SP, Brésil. L'OMS, acceptant seulement la séroneutralisation sur souris (NT), la méthode de référence, pour les études sur la protection contre le tétanos, préconise le titre de 0,01 UI/ml comme minimum protecteur. BOURLEAUD & HUET ont proposé la limite de 0,06 UI/ml quand s'emploie le test ELISA, en attendant à une certaine discordance inévitable entre les méthodes. Parmi les 674 sérums étudiés, 178 (26,41%) n'ont pas présenté d'anticorps (< 0,0025 UI/ml); 413 (61,28%) ont présenté des résultats égaux ou supérieurs à 0,01 UI/ml et en 232 (34,42%) les titres ont été égaux ou supérieurs à 0,06 UI/ml. Le pourcentage d'individus protégés a été inversement proportionnel à 1'âge: environ 50% dans le groupe le plus jeune (hommes de 18 à 35 ans et femmes de 18 à 23 ans) contre environ 10% dans le groupe de plus de 42 ans ont présenté des titres sûrement protecteurs (> 0,06 UI/ml).
Resumo:
An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.
Resumo:
Para evaluar la utilidad del método de recolección de muestras de sangre en papel de filtro para la detección de anticuerpos anti-dengue mediante un ELISA de Inhibición recientemente desarrollado en nuestro laboratorio, se realizó una toma simultánea de muestras de sangre en papel de filtro y de suero, de donantes de Banco de Sangre. Ambas muestras fueron conservadas a -20ºC y probadas a los 15 dias, 3 y 6 meses respectivamente. A las muestras que resultaron positivos se les amplió el rango de dilución para determinar título. Al realizar la comparación entre ambas muestras, sangre en papel de filtro y suero, encontramos que no existían diferencias de detección significativas, tanto para los casos positivos como los negativos. No obstante se observó en ambas muestras y de forma general una disminución del titulo de anticuerpos (una dilución) al transcurrir el tiempo máximo establecido en nuestro estudio (6 meses).
Resumo:
En una zona endémica de la República Argentina se llevó a cabo un ensayo de campo de la prueba inmunoenzimática ELISA para la detección de antígenos (cAg) y complejos inmunes circulantes (CIC) en sueros de pacientes chagásicos crónicos. Del total de 215 muestras de sangre analizadas, 51 fueron positivas para ELISA-CIC y 45 lo fueron para ELISA-cAg. De los 74 (34,32% de la población) sujetos considerados infectados con dos reacciones serológicas positivas, 49 (66,21%) presentaron CIC en suero, en tanto que en 43 (58,11%) de ellos se encontró cAg por ELISA. Solo en 2 casos serológicamente no reactivos, se detectaron inespecíficamente CIC y cAg. Dentro del grupo considerado no infectado, se observó reactividad inespecífica de bajo título por una de las pruebas serológicas en 16 (11,35%) de 141 individuos. Estos sueros arrojaron resultados consistentemente negativos por ELISA-CIC y cAg demostrando la utilidad de estos métodos de diagnóstico antigénico en casos de serología conflictiva. La determinación de fracciones antigénicas circulantes por ELISA en individuos chagásicos crónicos permite evidenciar la infección por T. cruzi de manera más directa que midiendo la respuesta inmune humoral en el huésped, presentando además mayor sensibilidad que el diagnóstico parasitológico clásico
Resumo:
An Enzyme-linked immunosorbent assay ELISA was evaluated for the detection of IgA antibodies in the human leptospirosis. The assay proved to be sensitive and specific when compared with the ELISA-IgM, in the examinated serum samples. The results found suggest that IgA antibodies became positive later in leptospirosis, and will can be an evolutive indicator in the development of the disease