991 resultados para digital subtraction radiography


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conventional radiography, using industrial radiographic films, has its days numbered. Digital radiography, recently, has taken its place in various segments of products and services, such as medicine, aerospace, security, automotive, etc. As well as the technological trend, the digital technique has brought proven benefits in terms of productivity, sensitivity, the environment, tools for image treatment, cost reductions, etc. If the weld to be inspected is on a serried product, such as, for example, a pipe, the best option for the use of digital radiography is the plane detector, since its use can reduce the length of the inspection cycle due to its high degree of automation. This work tested welded joints produced with the submerged arc process, which were specially prepared in such a way that it shows small artificial cracks, which served as the basis forcomparing the sensitivity levels of the techniques involved. After carrying out the various experiments, the digital meth odshowed the highest sensitivity for the image quality indicator (IQI) of the wire and also in terms of detecting small discontinuities, indicating that the use of digital radiography using the plane detector had advantages over the conventional technique (Moreira et al. Digital radiography, the use of plane detectors for the inspection of welds in oil pipes and gas pipes.9th COTEQ and XXV National Testing Congress for Non Destructive Testing and Inspection; Salvador, Bahia, Brazil and Bavendiek et al. New digital radiography procedure exceeds film sensitivity considerably in aerospace applications. ECNDT; 2006; Berlin). The works were carried out on the basis of the specifications for oil and gas pipelines, API 5L 2004 edition (American Petroleum Institute. API 5L: specification for line pipe. 4th ed. p. 155; 2004) and ISO 3183 2007 edition (International Organization for Standardization, ISO 3183. Petroleum and gas industries - steel pipes for pi pelines transportation systems. p. 143; 2007). © 2010 Taylor & Francis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption) that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm). The apparent tooth length (APTL) was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0), whereas the actual tooth length (ACTL) was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To date the hospital radiological workflow is completing a transition from analog to digital technology. Since the X-rays digital detection technologies have become mature, hospitals are trading on the natural devices turnover to replace the conventional screen film devices with digital ones. The transition process is complex and involves not just the equipment replacement but also new arrangements for image transmission, display (and reporting) and storage. This work is focused on 2D digital detector’s characterization with a concern to specific clinical application; the systems features linked to the image quality are analyzed to assess the clinical performances, the conversion efficiency, and the minimum dose necessary to get an acceptable image. The first section overviews the digital detector technologies focusing on the recent and promising technological developments. The second section contains a description of the characterization methods considered in this thesis categorized in physical, psychophysical and clinical; theory, models and procedures are described as well. The third section contains a set of characterizations performed on new equipments that appears to be some of the most advanced technologies available to date. The fourth section deals with some procedures and schemes employed for quality assurance programs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To assess the sensitivity and image quality of chest radiography (CXR) with or without dual-energy subtracted (ES) bone images in the detection of rib fractures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objective of our study was to compare the performance of low-dose linear slit digital radiography (DR) with computed radiography (CR) for the detection of trauma sequelae in the chest including rib fractures, pneumothorax, and lung contusion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ATLS Guidelines recommend single plain radiography of the chest and pelvis as part of the primary survey. Such isolated radiographs, usually obtained by bedside machines, can result in limited, low-quality studies that can adversely affect management. A new digital, low-radiation imaging device, the "Lodox Statscan" (LS), provides full-body anterior and lateral views based on enhanced linear slot-scanning technology in just over 5 minutes. We have the first LS in Europe at our facility. The aim of this study was to compare LS with computed tomographic (CT) scanning, as the gold standard, to determine the sensitivity of LS investigation in detecting injuries to the chest, thoracolumbar spine, and pelvis from our own experience, and to compare our findings with those of conventional radiography in the literature.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: To demonstrate the feasibility of panoramic image subtraction for implant assessment. STUDY DESIGN: Three titanium implants were inserted into a fresh pig mandible. One intraoral and 2 panoramic images were obtained at baseline and after each of 6 incremental (0.3, 0.6, 1.0, 1.5, 2.0, 2.5 mm) removals of bone. For each incremental removal of bone, the mandible was removed from and replaced in the holding device. Images representing incremental bone removals were registered by computer with the baseline images and subtracted. Assessment of the subtraction images was based on visual inspection and analysis of structured noise. RESULTS: Incremental bone removals were more visible in intraoral than in panoramic subtraction images; however, computer-based registration of panoramic images reduced the structured noise and enhanced the visibility of incremental removals. CONCLUSION: The feasibility of panoramic image subtraction for implant assessment was demonstrated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to simulate direct-digital cephalometric procedures and to record the head movements of probands. This study was prompted by the Committee for Insurance Matters of the Swiss National Invalidity Insurance which does not accept scanned digital cephalometric radiographs as a basis for its decisions. The reason for this is the required scanning time of several seconds during which even slight head movements can lead to kinetic blurring and landmark displacement. Incorrect angular measurements may result. By means of a Sirognathograph and a cephalostat of non-ferromagnetic material, the head movements of a total of 264 subjects were recorded in three dimensions, with a scanning time of up to 25 seconds. In a second series, the influence of a chin support to reduce head movements was also tested. The results of the first series of tests showed that, with an increasing scan time, movements became greater, mostly in the sagittal plane, and that maximum displacements could occur already at the start of the recording. With a scan time of 10 seconds the median movement amplitude in the vertical dimension was 2.14 mm. The second series of tests revealed a significant reduction in head movements in all dimensions owing to an additional stabilizing chin support. To minimize head movements, scanning times must be reduced and additional head stabilizing elements together with existing ones are necessary.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: In this experimental study we assessed the diagnostic performance of digital linear slit scanning radiography compared with computed radiography (CR) for the detection of urinary calculi in an anthropomorphic phantom imitating patients weighing approximately 58-88 kg. CONCLUSION: Compared with CR, linear slit scanning radiography is superior for the detection of urinary stones and may be used for pretreatment localization and follow-up at a lower patient exposure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this retrospective study was to intra-individually compare the image quality of computed radiography (CR) and low-dose linear-slit digital radiography (LSDR) for supine chest radiographs. A total of 90 patients (28 female, 62 male; mean age, 55.1 years) imaged with CR and LSDR within a mean time interval of 2.8 days +/- 3.0 were included in this study. Two independent readers evaluated the image quality of CR and LSDR based on modified European Guidelines for Quality Criteria for chest X-ray. The Wilcoxon test was used to analyse differences between the techniques. The overall image quality of LSDR was significantly better than the quality of CR (9.75 vs 8.16 of a maximum score of 10; p < 0.001). LSDR performed significantly better than CR for delineation of anatomical structures in the mediastinum and the retrocardiac lung (p < 0.001). CR was superior to LSDR for visually sharp delineation of the lung vessels and the thin linear structures in the lungs. We conclude that LSDR yields better image quality and may be more suitable for excluding significant pathological features of the chest in areas with high attenuation compared with CR.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have developed an empirically based simulation system to create images equivalent in SNR and SPR to those that would be acquired with various possible SEDR configurations. This system uses a collection of spot collimated full-field images (SCFFIs) of an anthropomorphic chest phantom, taken at high exposure levels and rescaled in noise and intensity, then digitally collimated and combined to produce the simulated SEDR images. This system allows for the study of design trade-offs between different equalization feedback schemes and scatter rejection geometries in addition to estimating the clinical benefits of SEDR over traditional imaging techniques. Data from this simulation system has demonstrated that SEDR techniques offer potential significant improvements over currently used digital radiography techniques for chest imaging. ^

Relevância:

40.00% 40.00%

Publicador:

Resumo:

FAPESP:95/02610

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to develop and test new digital imaging equipment and methods for diagnosis and follow-up of ocular diseases. Methods: The whole material comprised 398 subjects (469 examined eyes), including 241 patients with melanocytic choroidal tumours, 56 patients with melanocytic iris tumours, 42 patients with diabetes, a 52-year old patient with chronic phase of VKH disease, a 30-year old patient with an old blunt eye injury, and 57 normal healthy subjects. Digital 50° (Topcon TRC 50 IA) and 45° (Canon CR6-45NM) fundus cameras, a new handheld digital colour videocamera for eye examinations (MediTell), a new subtraction method using the Topcon Image Net Program (Topcon corporation, Tokyo, Japan), a new method for digital IRT imaging of the iris we developed, and Zeiss photoslitlamp with a digital camera body were used for digital imaging. Results: Digital 50° red-free imaging had a sensitivity of 97.7% and two-field 45° and 50° colour imaging a sensitivity of 88.9-94%. The specificity of the digital 45°-50° imaging modalities was 98.9-100% versus the reference standard and ungradeable images that were 1.2-1.6%. By using the handheld digital colour video camera only, the optic disc and central fundus located inside 20° from the fovea could be recorded with a sensitivity of 6.9% for detection of at least mild NPDR when compared with the reference standard. Comparative use of digital colour, red-free, and red light imaging showed 85.7% sensitivity, 99% specificity, and 98.2 % exact agreement versus the reference standard in differentiation of small choroidal melanoma from pseudomelanoma. The new subtraction method showed growth in four of 94 melanocytic tumours (4.3%) during a mean ±SD follow-up of 23 ± 11 months. The new digital IRT imaging of the iris showed the sphincter muscle and radial contraction folds of Schwalbe in the pupillary zone and radial structural folds of Schwalbe and circular contraction furrows in the ciliary zone of the iris. The 52-year-old patient with a chronic phase of VKH disease showed extensive atrophy and occasional pigment clumps in the iris stroma, detachment of the ciliary body with severe ocular hypotony, and shallow retinal detachment of the posterior pole in both eyes. Infrared transillumination imaging and fluorescein angiographic findings of the iris showed that IR translucence (p=0.53), complete masking of fluorescence (p=0.69), presence of disorganized vessels (p=0.32), and fluorescein leakage (p=1.0) at the site of the lesion did not differentiate an iris nevus from a melanoma. Conclusions: Digital 50° red-free and two-field 50° or 45° colour imaging were suitable for DR screening, whereas the handheld digital video camera did not fulfill the needs of DR screening. Comparative use of digital colour, red-free and red light imaging was a suitable method in the differentiation of small choroidal melanoma from different pseudomelanomas. The subtraction method may reveal early growth of the melanocytic choroidal tumours. Digital IRT imaging may be used to study changes of the stroma and posterior surface of the iris in various diseases of the uvea. It contributed to the revealment of iris atrophy and serous detachment of the ciliary body with ocular hypotony together with the shallow retinal detachment of the posterior pole as new findings of the chronic phase of VKH disease. Infrared translucence and angiographic findings are useful in differential diagnosis of melanocytic iris tumours, but they cannot be used to determine if the lesion is benign or malignant.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ensaio não destrutivo é uma ferramenta essencial quando um equipamento, dispositivo ou componente não pode ser submetido a procedimentos destrutivos ou invasivos devido a razões de segurança, alto custo ou outras restrições físicas ou logísticas. Dentro deste quadro radiografias por transmissão com raios gama e nêutrons térmicos são técnicas singulares para inspecionar um objeto e desvendar sua estrutura interna devido à capacidade de atravessar uma vasta gama de materiais utilizados na indústria. Grosso modo, raios gama são mais atenuados por materiais pesados enquanto nêutrons térmicos são mais atenuados por materiais mais leves, tornando-as ferramentas complementares. Este trabalho apresenta os resultados obtidos na inspeção de vários componentes mecânicos, através da radiografia por transmissão com nêutrons térmicos e raios gama. O fluxo de nêutrons térmicos de 4,46x105 n.cm-2.s-1 disponível no canal principal do reator de pesquisa Argonauta do Instituto de Engenharia Nuclear foi usado como fonte para as imagens radiográficas com nêutrons. Raios dekeV emitidos pelo 198Au, também produzido no reator, foram usados como fonte de radiação para radiografias . Imaging Plates, especificamente produzidos para operar com nêutrons térmicos ou com raios X, foram empregados como detectores e dispositivos de armazenamento e captação de imagens para cada uma dessas radiações. Esses dispositivos exibem varias vantagens quando comparados ao filme radiográfico convencional. Com efeito, além de maior sensibilidade e serem reutilizáveis não são necessários câmaras escuras e processamento químico para a revelação. Em vez disso, ele é lido por um feixe de laser que libera elétrons armadilhados na rede cristalina durante a exposição à radiação, fornecendo uma imagem final digital. O desempenho de ambos os sistemas de aquisição de imagens, assim constituído, foi avaliado com respeito à sensibilidade, resolução espacial, linearidade e range dinâmico, incluído uma comparação com sistemas radiográficos com nêutrons empregando filmes e folhas de gadolínio como conversor de nêutrons em partículas carregadas. Além desta caracterização, diversos equipamentos e componentes foram radiografados com ambos os sistemas visando-se avaliar suas capacidades de desvendar a estrutura interna desses objetos e detectar estruturas e estados anormais. Dentro desta abordagem, uma neutrongrafia detectou a presença de material cerâmico remanescente empregado como molde no processo de fabricação nos canais de refrigeração de uma aleta do estator de uma turbina tipo turbo-fan, que deveria estar livre desse material. O reostato danificado de um sensor de pressão automotivo, foi identificado por neutrongrafia, embora nesse caso a radiografia também conseguiu realizar essa tarefa com melhor resolução, corroborando assim as curvas de resolução espacial obtidas na caracterização dos dois sistemas. A homogeneidade da distribuição do material encapsulado em uma gaxeta explosiva de chumbo utilizada na indústria aeroespacial foi igualmente verificada por neutrongrafia porque esse metal é relativamente transparente para nêutrons, mas suficientemente opaco para o explosivo rico em hidrogênio. Diversos outros instrumentos e componentes tais como variômetro, altímetro, bússola aeronáutica, injetor automotivo de combustível, foto-camera, disco rígido de computador, motor de passo, conectores eletrônicos e projéteis foram radiografados com ambos os sistemas visando avaliar suas habilidades em desvendar diferentes peculiaridades em função do agente interrogador.