952 resultados para diagnostic laparoscopy
Resumo:
A significant number of Brazilian gestational-age women are still not tested for HIV, representing a high risk of transmission to their newborns. The current study sought to identify the number of pregnant women with no previous testing or undocumented for HIV referred to the Gynecology and Obstetrics Department of a Regional Teaching Hospital and included diagnosis of HIV infection determined by a rapid test and perinatal transmission in pregnancy. Medical records of all pregnant women admitted to hospital from January 2001 to December 2005 were reviewed. Pregnant women without HIV results were submitted to a rapid HIV test. Those who tested positive were further tested by ELISA and confirmed by indirect immunofluorescence assay (IIA) or Western blot (WB). The viral load from babies born to HIV-infected mothers was assessed by bDNA. Of the 16,424 pregnant women analyzed (6.6%), 1,089 were undocumented for HIV. Eleven women were positive in rapid testing and 10 were confirmed by ELISA, IIA or WB, with 0.9% seropositivity. Mother/infant pairs received zidovudine monotherapy prophylaxis and infant viral load was lower than 50 copies/mL. A higher number of pregnant women previously tested for HIV during antenatal care was verified, compared to that obtained nationwide.
Resumo:
Toxoplasma gondii causes severe fetal disease during acute infection in pregnant women, thus demanding early diagnosis for effective treatment and fetus preservation. Fetal tests are inefficient and risky, and diagnosis is based on maternal IgM serology, which had weak screening ability due to increased sensitivity, with alternative IgG avidity tests. Here, we performed ELISA and avidity assays using a recombinant T. gondii antigen, rROP2, in samples from 160 pregnant women screened from a large public hospital who were referred due to positive IgM assays. IgG serology and avidity assays were compared using whole T. gondii extract or rROP2. ELISA IgG detection with rROP2 showed good agreement with assays performed with T. gondii extract, but rROP2 IgG avidity assays were unrelated to whole extract antigen IgG avidity, regardless of the chaotrope used. These data show that avidity maturation is specific to individual antigen prevalence and immune response during infection. ELISA rROP2 IgG assays may be an alternative serological test for the diagnosis of toxoplasmosis during pregnancy, although our data do not support their use in avidity assays.
Resumo:
The main serological marker for the diagnosis of recent toxoplasmosis is the specific IgM antibody, along with IgG antibodies of low avidity. However, in some patients these antibodies may persist long after the acute/recent phase, contributing to misdiagnosis in suspected cases of toxoplasmosis. In the present study, the diagnostic efficiency of ELISA was evaluated, with the use of peptides derived from T. gondii ESA antigens, named SAG-1, GRA-1 and GRA-7. In the assay referred to, we studied each of these peptides individually, as well as in four different combinations, as Multiple Antigen Peptides (MAP), aiming to establish a reliable profile for the acute/recent toxoplasmosis with only one patient serum sample. The diagnostic performance of the assay using MAP1, with the combination of SAG-1, GRA-1 and GRA-7 peptides, demonstrated better discrimination of the acute/recent phase from non acute/recent phase of toxoplasmosis. Our results show that IgM antibodies to MAP1 may be useful as a serological marker, enhancing the diagnostic efficiency of the assay for acute/recent phase of toxoplasmosis.
Resumo:
Overview and Aims: The investigation of recurrent miscarriage includes the study of uterine morphology. 3D ultrasound allows the evaluation of the morphology (cavity and outer contour), reducing the need for invasive tests such as hystero - salpingography (HSG), hysteroscopy and laparoscopy. We evaluated the diagnostic agreement between HSG and 3D ultrasound in the study of the uterine cavity morphology. Study Design: Prospective study. Population: A total of 34 women referred to our institution with a history of recurrent miscarriage. Methods: To compare the results of 3D ultrasound and HSG, all women underwent both exams. 3D scans were performed by the same operator and HSG were evaluated by the same clinician. The concordance study was performed using the Kappa coefficient. Results: With 3D ultrasound and HSG, uterine anomalies were diagnosed in 52.9% (18/34) and 47% (16/34) of the cases and congenital malformations were the most frequent findings. The agreement between the two techniques was excellent(K = 0.825). The three cases of diagnostic disagreement were analyzed. Conclusion: A high level of diagnostic agreement was observed between HSG and 3D ultrasound. The 3D ultrasound, a low cost and well tolerated technique, when performed by an experienced operator, is the first line exam to study the uterine morphology in women with recurrent miscarriage.
Resumo:
After the report of a second case of canine visceral leishmaniasis (CVL) in São Bento da Lagoa, Itaipuaçu, in the municipality of Maricá, Rio de Janeiro State, an epidemiological survey was carried out, through active search, totaling 145 dogs. Indirect immunofluorescence assay (IFA), enzyme-linked immunosorbent assay (ELISA), and rapid chromatographic immunoassay based on dual-path platform (DPP(r)) were used to perform the serological examinations. The parasitological diagnosis of cutaneous fragments was performed by parasitological culture, histopathology, and immunohistochemistry. In the serological assessment, 21 dogs were seropositive by IFA, 17 by ELISA, and 11 by DPP(r), with sensitivity of 66.7%, 66.7% and 50%, and specificity of 87.2%, 90.2% and 94%, respectively for each technique. The immunohistochemistry of bone marrow using the cell-block technique presented the best results, with six positive dogs found, three of which tested negative by the other parasitological techniques. Leishmania sp. was isolated by parasitological culture in three dogs. The detection of autochthonous Leishmania infantum in Itaipuaçu, and the high prevalence of seropositive dogs confirm the circulation of this parasite in the study area and alert for the risk of expansion in the State of Rio de Janeiro.
Resumo:
Mastocytosis refers to a group of disorders characterized by the infiltration of clonally derived mast cells to the skin or extracutaneous tissues resulting in a heterogeneous clinical picture. It is a rare hematologic disorder in all its forms. The exact incidence is unknown; it affects patients of any age and males and females equally. Its molecular pathogenesis is incompletely understood. The clinical features of mastocytosis result from both chronic and episodic mast cell mediator release, signs and symptoms arising from diffuse or focal tissue infiltration, and, occasionally, the presence of an associated non-mast cell clonal hematologic disease. The histopathologic analysis is essential for definitive diagnosis but there is no curative treatment. The authors report a clinical case of a 72-year-old woman with no history of allergies, with bicytopenia, weight loss, and diffuse axial osteolytic lesions. This is a rare clinical case of aggressive systemic mastocytosis for which palliative treatment can improve survival and quality of life. A brief review of the literature about this pathology is also included.
Resumo:
The liver abscess is the most frequent extraintestinal complication of intestinal amoebiasis: its diagnosis is suggested by the clinical picture but it must be confirmed by paraclinic tests. Themost stringent diagnosis requires identification of E. histolytica. But this is possible only in a few cases. Serological tests greatly improve the diagnosis of this severe complication of amoebiasis. We compared the Enzyme Linfed Immunosorbent Assay and the Counterimmunoeletrophoresis techniques. Both techniques were used to detect amoebic antibodies in 50 control patients, 30 patients with liver abscess and 30 patients with intestinal amoebiasis. All the sera from control patients gave negative results iin both techniques. When analysing the sera from patients with intestinal amoebiasis, 10% of them were positive by ELISA but non by CIE. The sera of patients with liver abscess, we found that 90% were positive by the ELISA method and 66.6% by the CIE technique. In patients with amoebic liver abscess, the results showed that the ELISA was more sensitive than the CIE, as it presented a higher sensitivity (100%) than that of the CIE technique (66%).
Resumo:
Dissertação para obtenção do Grau de Doutor em Química Sustentável
Resumo:
Some epidemiological characteristics of head lice, Pediculus capitis, were studied using two procedures: cut hair analysis and head inspection. Higher prevalence rates were observed in the middle and at the end of the school terms. Both procedures indicated that children were the main reservoir for this type of pediculosis in Uberlândia.
Resumo:
Trypanosoma cruzi infection is often not detected early on or actively diagnosed, partly because most infected individuals are either asymptomatic or oligosymptomatic. Moreover, in most places, neither blood banks nor healthcare units offer diagnostic confirmation or treatment access. By the time patients present clinical manifestations of advanced chronic Chagas disease, specific treatment with current drugs usually has limited effectiveness. Better-quality serological assays are urgently needed, especially rapid diagnostic tests for diagnosis patients in both acute and chronic phases, as well as for confirming that a parasitological cure has been achieved. Some new antigen combinations look promising and it is important to assess which ones are potentially the best, together with their requirements in terms of investigation and development. In August 2007, a group of specialized researchers and healthcare professionals met to discuss the state of Chagas infection diagnosis and to build a consensus for a plan of action to develop efficient, affordable, accessible and easy-to-use diagnostic tests for Chagas disease. This technical report presents the conclusions from that meeting.
Resumo:
Female genital schistosomiasis is not uncommon in endemic areas for schistosomiasis, but there are few reports in the Brazilian medical literature. Here, we describe the case of a 31-year-old woman with lower abdominal pain who was diagnosed as presenting a fallopian tube tumor caused by Manson's schistosomiasis. The diagnosis was delayed because her symptoms were considered nonspecific. Involvement of the parietal peritoneum of the ovarian fossa was observed during laparoscopy and confirmed by histological analysis. The left tube and the tumor were excised and schistosomiasis was treated with praziquantel. She presented a full recovery and options for future reproduction are under evaluation.
Resumo:
The use, manipulation and application of electrical currents, as a controlled interference mechanism in the human body system, is currently a strong source of motivation to researchers in areas such as clinical, sports, neuroscience, amongst others. In electrical stimulation (ES), the current applied to tissue is traditionally controlled concerning stimulation amplitude, frequency and pulse-width. The main drawbacks of the transcutaneous ES are the rapid fatigue induction and the high discomfort induced by the non-selective activation of nervous fibers. There are, however, electrophysiological parameters whose response, like the response to different stimulation waveforms, polarity or a personalized charge control, is still unknown. The study of the following questions is of great importance: What is the physiological effect of the electric pulse parametrization concerning charge, waveform and polarity? Does the effect change with the clinical condition of the subjects? The parametrization influence on muscle recruitment can retard fatigue onset? Can parametrization enable fiber selectivity, optimizing the motor fibers recruitment rather than the nervous fibers, reducing contraction discomfort? Current hardware solutions lack flexibility at the level of stimulation control and physiological response assessment. To answer these questions, a miniaturized, portable and wireless controlled device with ES functions and full integration with a generic biosignals acquisition platform has been created. Hardware was also developed to provide complete freedom for controlling the applied current with respect to the waveform, polarity, frequency, amplitude, pulse-width and duration. The impact of the methodologies developed is successfully applied and evaluated in the contexts of fundamental electrophysiology, psycho-motor rehabilitation and neuromuscular disorders diagnosis. This PhD project was carried out in the Physics Department of Faculty of Sciences and Technology (FCT-UNL), in straight collaboration with PLUX - Wireless Biosignals S.A. company and co-funded by the Foundation for Science and Technology.
Resumo:
INTRODUCTION: West Nile virus (WNV) is a flavivirus with a natural cycle involving mosquitoes and birds. Over the last 11 years, WNV has spread throughout the Americas with the imminent risk of its introduction in Brazil. METHODS: Envelope protein domain III of WNV (rDIII) was bacterially expressed and purified. An enzyme-linked immunosorbent assay with WNV rDIII antigen was standardized against mouse immune fluids (MIAFs) of different flavivirus. RESULTS: WNV rDIII reacted strongly with St. Louis encephalitis virus (SLEV) MIAF but not with other flaviviruses. CONCLUSIONS: This antigen may be a potentially useful tool for serologic diagnosis and may contribute in future epidemiological surveillance of WNV infections in Brazil.
Resumo:
Introduction Dengue is prevalent in many tropical and sub-tropical regions. The clinical diagnosis of dengue is still complex, and not much data are available. This work aimed at assessing the diagnostic accuracy of the tourniquet test in patients with suspected dengue infection and its positivity in different classifications of this disease as reported to the Information System for Notifiable Disease in Belo Horizonte, State of Minas Gerais, Brazil between 2001 and 2006. Methods Cross-section analysis of the diagnostic accuracy of the tourniquet test for dengue, using IgM-anti-DENV ELISA as a gold standard. Results We selected 9,836 suspected cases, of which 41.1% were confirmed to be dengue. Classic dengue was present in 95.8%, dengue with complications in 2.5% and dengue hemorrhagic fever in 1.7%. The tourniquet test was positive in 16.9% of classic dengue cases, 61.7% of dengue cases with complications and 82.9% of cases of dengue hemorrhagic fever. The sensitivity and specificity of the tourniquet test were 19.1% and 86.4%, respectively. Conclusions A positive tourniquet test can be a valuable tool to support diagnosis of dengue where laboratory tests are not available. However, the absence of a positive test should not be read as the absence of infection. In addition, the tourniquet test was demonstrated to be an indicator of dengue severity.