891 resultados para diagnostic delay


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumours of the brachial plexus region are rare and most publications are case reports or studies with a small series of patients. The aim of this study is to present our experience in managing these lesions. We review 18 patients with tumours in the brachial plexus region submitted to surgical treatment in a 6 year period, including their clinical presentation, neuro-imaging data, surgical findings and outcome. The tumours comprised a heterogeneous group of lesions, including schwannomas, neurofibromas, malignant peripheral nerve sheath tumour (MPNST), sarcomas, metastases, desmoids and an aneurysmal bone cyst. The most common presentation was an expanding lump (83.33%). Eleven tumours were benign and 7 were malignant. Neurofibromatosis was present in only 2 patients (11.11%). Gross total resection was achieved in 14 patients and sub-total resection in the others. Only 3 patients presented with new post-operative motor deficits. The incidence of complications was low (16.5 %). The majority of tumours were benign and most of them could be excised with a low incidence of additional deficits. Some of the malignant tumours could be controlled by surgery plus adjuvant therapy, but this category is still associated with high morbidity and mortality rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Design: Prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: Thirty-nine anesthetized mechanically ventilated supine pigs (31.0 +/- 3.2 kg, mean +/- SD). Interventions. In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 to 500 mL) through chest tubes or applied large positive end-expiratory pressure (PEEP) increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or preinjured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Measurements and Main Results: Primary EIT relative images were acquired online (50 images/sec) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20 mL could be detected with a sensitivity of 100% and specificity 95% and could be easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers, Their location was correctly identified in all cases, with a total delay of only three respiratory cycles. Conclusions. We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: A better means to accurately identify malignant thyroid nodules and to distinguish them from benign tumors is needed. We previously identified markers for detecting thyroid malignancy, with sensitivity estimated at or close to 100%. One lingering problem with these markers was that false positives occurred with Hurthle cell adenomas (HCA) which lowered test specificity. Methods: To locate accurate diagnostic markers, we profiled in depth the transcripts of a HCA and a Hurthle cell carcinoma (HCC). From 1146 differentially expressed genes, 18 transcripts specifically expressed in HCA were tested by quantitative PCR in a wide range of thyroid tumors (n = 76). Sensibility and specificity were calculated using receiver operating characteristic (ROC). Selected markers were further validated in an independent set of thyroid tumors (n = 82) by immunohistochemistry. To define the panel that would yield best diagnostic accuracy, these markers were tested in combination with our previous identified markers. Results: Seventeen of the 18 genes showed statistical significance based on a mean relative level of expression (P < 0.05). KLK1 (sensitivity = 0.97) and PVALB (sensitivity = 0.94) were the best candidate markers. The combination of PVALB and C1orf24 increased specificity to > 97% and maintained sensitivity for detection of carcinoma. Conclusion: We identified tumor markers that can be used in combination for a more accurate preoperative diagnosis of thyroid nodules and for postoperative diagnosis of thyroid carcinoma in tumor sections. This improved test would help physicians rapidly focus treatment on true malignancies and avoid unnecessary treatment of benign tumors, simultaneously improving medical care and reducing costs. (J Clin Endocrinol Metab 96: E151-E160, 2011)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orofacial granulomatosis is a condition that, may be difficult to diagnose for those unfamiliar with the entity. This paper describes two cases and addresses the presentation, pathogenesis and treatment. The clinical recognition of his condition is important as is the subsequent investigation by an appropriate specialist. Management of patients needs to take into account the results of further investigations, the patient's expectations, and the severity of the condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Upper airway stenosis (UAS) after endotracheal intubation is a common problem in children. Most literature refers to a surgical treatment for these lesions. Laryngotracheal reconstruction and cricotracheal resection are used for low- and high-grade stenosis, but decannulation is not always possible immediately after surgery. Purpose: The aim of this study was to verify the feasibility and results of endoscopic dilatations for treatment of subglottic stenosis. Method: The study encompassed a 12-year retrospective analysis of patients treated for UAS in a tertiary center. All children were symptomatic at the time of the endoscopic diagnosis. The stenosis was graded according to the Myer-Cotton criteria. Endoscopic dilatation was initiated immediately after the diagnosis. Children with grade IV stenosis underwent surgery. Results: Children with tracheal stenosis and no involvement of the subglottic area did not respond to endoscopic dilatations and underwent surgery. There were 45 children with grade I stenosis, 12 with grade II, 7 with grade III, and 4 with grade IV lesions. Patients with grade I, II, and III stenosis were a] I treated by endoscopic dilatations alone and were decannulated when asymptomatic. The average time for decannulation was 18.90 +/- 26.07 months for grade 1, 32.5 +/- 27.08 months for grade 11, and 27.57 +/- 20.60 months for grade III stenosis (P < .01, for grade II vs grade III). Conclusion: Grade I, II, and III subglottic stenoses can be safely managed by early endoscopic dilatations with a high rate of success and low rate of morbidity but require a significantly long period of treatment. (C) 2008 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the rate of comorbidities and the functional impairment associated with the social anxiety disorder (SAD), with an emphasis on the so-called subthreshold clinical signs and symptoms. Method: Psychiatric comorbidities and psychosocial functioning were evaluated in 355 volunteers (college students) who had been diagnosed as SAD (n = 141), Subthreshold SAD (n = 92) or Controls (n = 122). Results: The rate of comorbidities was 71.6% in the SAD group and 50% in subjects with Subthreshold SAD, both significantly greater than Controls (28.7%). Concerning psychosocial functioning, the SAD group had higher impairment than the other two groups in all domains evaluated, and subjects with Subthreshold SAD presented intermediate values. Conclusion: The rates of psychiatric comorbidities and the impairment of psychosocial functioning increase progressively along the spectrum of social anxiety. The fact that Subthreshold SAD causes considerable disability and suffering in comparison with control subjects justifies a review of the validity of the diagnostic criteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the use of Raman spectroscopy to identify the spectral differences between normal (N), benign hyperplasia (BPH) and adenocarcinoma (CaP) in fragments of prostate biopsies in vitro with the aim of developing a spectral diagnostic model for tissue classification. A dispersive Raman spectrometer was used with 830 nm wavelength and 80 mW excitation. Following Raman data collection and tissue histopathology (48 fragments diagnosed as N, 43 as BPH and 14 as CaP), two diagnostic models were developed in order to extract diagnostic information: the first using PCA and Mahalanobis analysis techniques and the second one a simplified biochemical model based on spectral features of cholesterol, collagen, smooth muscle cell and adipocyte. Spectral differences between N, BPH and CaP tissues, were observed mainly in the Raman bands associated with proteins, lipids, nucleic and amino acids. The PCA diagnostic model showed a sensitivity and specificity of 100%, which indicates the ability of PCA and Mahalanobis distance techniques to classify tissue changes in vitro. Also, it was found that the relative amount of collagen decreased while the amount of cholesterol and adipocyte increased with severity of the disease. Smooth muscle cell increased in BPH tissue. These characteristics were used for diagnostic purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This was a prospective study carried out during a period over 2 years (May/2006-September/2008) with a cohort of 1,099 individuals of both genders, aged 1 year old and older, from an endemic area of American visceral leishmaniasis (AVL) in Para state, Brazil. The object was to analyze the prevalence and incidence of human Leishmania (L.) infantum chagasi infection as well as the dynamics evolution of its clinical-immunological profiles prior identified: (1) asymptomatic infection (AI); (2) symptomatic infection (SI = AVL); (3) sub-clinical oligosymptomatic infection (SOI); (4) sub-clinical resistant infection (SRI) and; (5) indeterminate initial infection (III). The infection diagnosis was performed by using both the indirect fluorescent antibody test and leishmanin skin test with amastigotes and promastigotes antigens of L. (L.) i. chagasi, respectively. A total of 187 cases of infection were recorded in the prevalence (17%), 117 in the final incidence (6.9%), and 304 in the accumulated prevalence (26.7%), which provided the following distribution into the clinical-immunological profiles: AI, 51.6%; III, 22.4%; SRI, 20.1%; SOI, 4.3%; and SI (=AVL), 1.6%. The major finding regarding the dynamics evolution of infection was concerned to III profile, from which the cases of infection evolved to either the resistant profiles, SRI (21 cases, 30.8%) and AI (30 cases, 44.1%), or the susceptible SI (=AVL; 1 case, 1.5%); the latter 16 cases remained as III till the end of the study. These results provided the conclusion that this diagnostic approach may be useful for monitoring human L. (L.) i. chagasi infection in endemic area and preventing the high morbidity of severe AVL cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516