966 resultados para detection method


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Web servers are usually located in a well-organized data center where these servers connect with the outside Internet directly through backbones. Meanwhile, the application-layer distributed denials of service (AL-DDoS) attacks are critical threats to the Internet, particularly to those business web servers. Currently, there are some methods designed to handle the AL-DDoS attacks, but most of them cannot be used in heavy backbones. In this paper, we propose a new method to detect AL-DDoS attacks. Our work distinguishes itself from previous methods by considering AL-DDoS attack detection in heavy backbone traffic. Besides, the detection of AL-DDoS attacks is easily misled by flash crowd traffic. In order to overcome this problem, our proposed method constructs a Real-time Frequency Vector (RFV) and real-timely characterizes the traffic as a set of models. By examining the entropy of AL-DDoS attacks and flash crowds, these models can be used to recognize the real AL-DDoS attacks. We integrate the above detection principles into a modularized defense architecture, which consists of a head-end sensor, a detection module and a traffic filter. With a swift AL-DDoS detection speed, the filter is capable of letting the legitimate requests through but the attack traffic is stopped. In the experiment, we adopt certain episodes of real traffic from Sina and Taobao to evaluate our AL-DDoS detection method and architecture. Compared with previous methods, the results show that our approach is very effective in defending AL-DDoS attacks at backbones. © 2013 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper presents a functional observer based fault detection method. The fault detection is achieved using a functional observer based fault indicator that asymptotically converges to a fault indicator that can be derived based on the nominal system. The asymptotic value of the proposed fault indicator is independent of the functional observer parameters and also the convergence rate of the fault indicator can be altered by choosing appropriate functional observer parameters. The advantage of using this new method is that the observed system is not necessarily needed to be observable; therefore, the proposed fault detection technique is also applicable for systems where state observers cannot be designed; moreover, the functional observer fault detection scheme is always of reduced order in comparison to a state observer based scheme.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Proposing efficient methods for fire protection is becoming more and more important, because a small flame of fire may cause huge problems in social safety. In this paper, an effective fire flame detection method is investigated. This fire detection method includes four main stages: in the first step, a linear transformation is applied to convert red, green, and blue (RGB) color space through a 3∗3 matrix to a new color space. In the next step, fuzzy c-mean clustering method (FCM) is used to distinguish between fire flame and non-fire flame pixels. Particle Swarm Optimization algorithm (PSO) is also utilized in the last step to decrease the error value measured by FCM after conversion. Finally, we apply Otsu threshold method to the new converted images to make a binary picture. Empirical results show the strength, accuracy and fast-response of the proposed algorithm in detecting fire flames in color images.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Classification of electrocardiogram (ECG) data stream is essential to diagnosis of critical heart conditions. It is vital to accurately detect abnormality in the ECG in order to prevent possible beginning of life-threatening cardiac symptoms. In this paper, we focus on identifying premature ventricular contraction (PVC) which is one of the most common heart rhythm abnormalities. We use "Replacing" strategy to check the effects of each individual heartbeat on the variation of principal directions. Based on this idea, an online PVC detection method is proposed to classify the new arriving PVC beats in the real-time and online manner. The proposed approach is tested on the MIT-BIH arrhythmia database (MIT-BIH-AR). The PVC detection accuracy was 98.77%, with the sensitivity and positive predictivity of 96.12% and 86.48%, respectively. These results are an improvement on previous reported results for PVC detection. In addition, our proposed method is effective in terms of computation time. The average execution time of our proposed method was 3.83 s for a 30 min ECG recording. It shows the capability of the classifier to detect abnormal PVCs in online manner.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We present a two-colour photocurrent detection method for coherent control of a single InGaAs/GaAs self-assembled quantum dot. A pulse shaping technique provides a high degree of control over picosecond optical pulses. Rabi rotations on the exciton to biexciton transition are presented, and fine structure beating is detected via time-resolved measurements. (c) 2009 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A label-free electrochemical detection method for DNA hybridization based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes is reported. Synthetic single-stranded 27-mer oligonucleotides (probe) have been immobilized at 2,5-bis(2-thienyl)-N-(3-phosphorylpropyl)pyrrole film formed by electropolymerization on the previously formed polypyrrole layer. The 27- or 18-mer target oligonucleotides were monitored via the electrochemically driven anion exchange of the inner polypyrrole film. The performance of the miniaturized DNA biosensor system was studied in respect to selectivity, sensitivity, reproducibility, and regeneration of the sensor. Control experiments were performed with a noncomplementary target of 27-mer DNA and 12 base-pair mismatched 18-mer sequences, respectively, and did not show any unspecific binding. Under optimized experimental conditions, the label-free electrochemical biosensor enabled the detection limits of 0.16 and 3.5 fmol for the 18- and 2 7-mer DNA strand, respectively. Furthermore, we demonstrate reusability of the electrochemical DNA biosensor after successful recovery of up to 100% of the original signal by regenerating the DNA label-free electrode with 50 mM HCl at room temperature.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A gas chromatography-mass-selective (GC-MS) detection method to determine buprofezin, pyridaben, and tebufenpyrad on the pulp, peel, and whole fruit of clementines is described. The extraction/partition procedure was performed in one step and no cleanup was necessary with the GC-MS in the SIM-mode pesticide determination. Recovery ranged from 75 to 124% with coefficients of variance ranging between 1 and 13%. The limit of determination was 0.01 mg/kg for all pesticides. The field trials showed a similar degradative behavior for all active ingredients (AI), with a great residue decrease during the first week and stability in the second. Just after treatment buprofezin and tebufenpyrad showed lower residues than the maximum residue limit (MRL) fixed in Italy, while pyridaben was below the MRL after a week.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

PCR and nested-PCR methods were used to assess the frequency of Babesia bovis and Babesia bigemina infection in Boophilus microplus engorged females and eggs and in cattle reared in an area with endemic babesiosis. Blood and the engorged female ticks were from 27 naturally infested calves and 25 crossbred cows. The frequency of both Babesia species was similar in calves and cows (P > 0.05). Babesia bovis was detected in 23 (85.2%) calves and in 25 (100%) cows and B. bigemina was detected in 25 (92.6%) calves and in 21 (84%) cows. Mixed infections with the both Babesia species were identified in 42 animals, 21 in each age category. Of female ticks engorged on calves, 34.9% were negative and single species infection with B. bigemina (56.2%) was significantly more frequent (P < 0.01) than with B. bovis (4.7%). Most of the females (60.8%) engorged on cows did not show Babesia spp. infection and the frequency of single B. bovis infection (17.6%) was similar (P > 0.05) to the frequency of single B. bigemina infection (15.9%). Mixed Babesia infection was lower (P < 0.01) than single species infection in female ticks engorged either in cows (5.7%) or in calves (4.3%). An egg sample from each female was analysed for the presence of Babesia species. Of the egg samples from female ticks infected with B. bovis, 26 (47.3%) were infected while from those from female ticks infected with B. bigemina 141 (76.6%) were infected (P < 0.01). The results showed that although the frequency of both species of Babesia was similar in calves and cows, the infectivity of B. bigemina was higher to ticks fed on calves while to those ticks fed on cows the infectivity of both Babesia species was similar. © 2004 Australian Society for Parasitology Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This project has been developed to evaluate the possible relationship between the cesspit (pit latrine) in as far as it degrades the quality of underground water. Its importance is due to the fact that in the rural communities in the State of São Paulo (Brazil) this type of cesspit is very common as a means of sewage disposal and these communities use underground water for their supply of drinking water. Rural properties distributed over the rural area in the municipality of São José do Rio Preto were selected. A preliminary study was then set up to determine the social situation and health of the households as well as qualitative evaluations on the type of water supply and sewage disposal of these communities. Campaigns of water sampling then followed and laboratory analyses of water taken from wells were carried out. Parameters were set up to evaluate the potability according to Brazilian legislation (2004) paying attention to microbiologic (coliforms, Crytosporidium sp., and adenovirus). The analyses showed evidence of possible interaction between the wells and the sewage effluents and drainage in these communities. A PCR reaction to detect adenovirus showed a presence in 53.3% of the samples. The tests for the detection of Cryotosporidium sp all showed a negative result.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: In epidemiological surveys, a good reliability among the examiners regarding the caries detection method is essential. However, training and calibrating those examiners is an arduous task because it involves several patients who are examined many times. To facilitate this step, we aimed to propose a laboratory methodology to simulate the examinations performed to detect caries lesions using the International Caries Detection and Assessment System (ICDAS) in epidemiological surveys. Methods: A benchmark examiner conducted all training sessions. A total of 67 exfoliated primary teeth, varying from sound to extensive cavitated, were set in seven arch models to simulate complete mouths in primary dentition. Sixteen examiners (graduate students) evaluated all surfaces of the teeth under illumination using buccal mirrors and ball-ended probe in two occasions, using only coronal primary caries scores of the ICDAS. As reference standard, two different examiners assessed the proximal surfaces by direct visual inspection, classifying them in sound, with non-cavitated or with cavitated lesions. After, teeth were sectioned in the bucco-lingual direction, and the examiners assessed the sections in stereomicroscope, classifying the occlusal and smooth surfaces according to lesion depth. Inter-examiner reproducibility was evaluated using weighted kappa. Sensitivities and specificities were calculated at two thresholds: all lesions and advanced lesions (cavitated lesions in proximal surfaces and lesions reaching the dentine in occlusal and smooth surfaces). Conclusion: The methodology purposed for training and calibration of several examiners designated for epidemiological surveys of dental caries in preschool children using the ICDAS is feasible, permitting the assessment of reliability and accuracy of the examiners previously to the survey´s development.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Polymerase chain reaction (PCR) is a sensitive tool for detection of respiratory picornaviruses. However, the clinical relevance of picornavirus detection by PCR is unclear. Immunofluorescence (IF), widely used to detect other respiratory viruses, has recently been introduced as a promising detection method for respiratory picornaviruses. OBJECTIVES: To compare the clinical manifestations of respiratory picornavirus infections detected by IF with those of respiratory picornavirus infections detected by xTAG multiplex PCR in hospitalized children. STUDY DESIGN: During a 1-year period, nasopharyngeal aspirates (NPA) from all children hospitalized due to an acute respiratory infection were prospectively analyzed by IF. All respiratory picornavirus positive IF samples and 100 IF negative samples were further tested with xTAG multiplex PCR. After exclusion of children with co-morbidities and viral co-infections, monoinfections with respiratory picornaviruses were detected in 108 NPA of 108 otherwise healthy children by IF and/or PCR. We compared group 1 children (IF and PCR positive, n=84) with group 2 children (IF negative and PCR positive, n=24) with regard to clinical manifestations of the infection. RESULTS: Wheezy bronchitis was diagnosed more often in group 1 than in group 2 (71% vs. 46%, p=0.028). In contrast, group 2 patients were diagnosed more frequently with pneumonia (17% vs. 6%, p=0.014) accompanied by higher levels of C-reactive protein (46mg/l vs. 11mg/l, p=0.009). CONCLUSIONS: Picornavirus detection by IF in children with acute respiratory infection is associated with the clinical presentation of wheezy bronchitis. The finding of a more frequent diagnosis of pneumonia in picornavirus PCR positive but IF negative children warrants further investigation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This report presents the development of a Stochastic Knock Detection (SKD) method for combustion knock detection in a spark-ignition engine using a model based design approach. Knock Signal Simulator (KSS) was developed as the plant model for the engine. The KSS as the plant model for the engine generates cycle-to-cycle accelerometer knock intensities following a stochastic approach with intensities that are generated using a Monte Carlo method from a lognormal distribution whose parameters have been predetermined from engine tests and dependent upon spark-timing, engine speed and load. The lognormal distribution has been shown to be a good approximation to the distribution of measured knock intensities over a range of engine conditions and spark-timings for multiple engines in previous studies. The SKD method is implemented in Knock Detection Module (KDM) which processes the knock intensities generated by KSS with a stochastic distribution estimation algorithm and outputs estimates of high and low knock intensity levels which characterize knock and reference level respectively. These estimates are then used to determine a knock factor which provides quantitative measure of knock level and can be used as a feedback signal to control engine knock. The knock factor is analyzed and compared with a traditional knock detection method to detect engine knock under various engine operating conditions. To verify the effectiveness of the SKD method, a knock controller was also developed and tested in a model-in-loop (MIL) system. The objective of the knock controller is to allow the engine to operate as close as possible to its border-line spark-timing without significant engine knock. The controller parameters were tuned to minimize the cycle-to-cycle variation in spark timing and the settling time of the controller in responding to step increase in spark advance resulting in the onset of engine knock. The simulation results showed that the combined system can be used adequately to model engine knock and evaluated knock control strategies for a wide range of engine operating conditions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fuzzy community detection is to identify fuzzy communities in a network, which are groups of vertices in the network such that the membership of a vertex in one community is in [0,1] and that the sum of memberships of vertices in all communities equals to 1. Fuzzy communities are pervasive in social networks, but only a few works have been done for fuzzy community detection. Recently, a one-step forward extension of Newman’s Modularity, the most popular quality function for disjoint community detection, results into the Generalized Modularity (GM) that demonstrates good performance in finding well-known fuzzy communities. Thus, GMis chosen as the quality function in our research. We first propose a generalized fuzzy t-norm modularity to investigate the effect of different fuzzy intersection operators on fuzzy community detection, since the introduction of a fuzzy intersection operation is made feasible by GM. The experimental results show that the Yager operator with a proper parameter value performs better than the product operator in revealing community structure. Then, we focus on how to find optimal fuzzy communities in a network by directly maximizing GM, which we call it Fuzzy Modularity Maximization (FMM) problem. The effort on FMM problem results into the major contribution of this thesis, an efficient and effective GM-based fuzzy community detection method that could automatically discover a fuzzy partition of a network when it is appropriate, which is much better than fuzzy partitions found by existing fuzzy community detection methods, and a crisp partition of a network when appropriate, which is competitive with partitions resulted from the best disjoint community detections up to now. We address FMM problem by iteratively solving a sub-problem called One-Step Modularity Maximization (OSMM). We present two approaches for solving this iterative procedure: a tree-based global optimizer called Find Best Leaf Node (FBLN) and a heuristic-based local optimizer. The OSMM problem is based on a simplified quadratic knapsack problem that can be solved in linear time; thus, a solution of OSMM can be found in linear time. Since the OSMM algorithm is called within FBLN recursively and the structure of the search tree is non-deterministic, we can see that the FMM/FBLN algorithm runs in a time complexity of at least O (n2). So, we also propose several highly efficient and very effective heuristic algorithms namely FMM/H algorithms. We compared our proposed FMM/H algorithms with two state-of-the-art community detection methods, modified MULTICUT Spectral Fuzzy c-Means (MSFCM) and Genetic Algorithm with a Local Search strategy (GALS), on 10 real-world data sets. The experimental results suggest that the H2 variant of FMM/H is the best performing version. The H2 algorithm is very competitive with GALS in producing maximum modularity partitions and performs much better than MSFCM. On all the 10 data sets, H2 is also 2-3 orders of magnitude faster than GALS. Furthermore, by adopting a simply modified version of the H2 algorithm as a mutation operator, we designed a genetic algorithm for fuzzy community detection, namely GAFCD, where elite selection and early termination are applied. The crossover operator is designed to make GAFCD converge fast and to enhance GAFCD’s ability of jumping out of local minimums. Experimental results on all the data sets show that GAFCD uncovers better community structure than GALS.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Enzootic pneumonia (EP) of pigs, caused by Mycoplasma hyopneumoniae has been a notifiable disease in Switzerland since May 2003. The diagnosis of EP has been based on multiple methods, including clinical, bacteriological and epidemiological findings as well as pathological examination of lungs (mosaic diagnosis). With the recent development of a real-time PCR (rtPCR) assay with 2 target sequences a new detection method for M. hyopneumoniae became available. This assay was tested for its applicability to nasal swab material from live animals. Pigs from 74 herds (average 10 pigs per herd) were tested. Using the mosaic diagnosis, 22 herds were classified as EP positive and 52 as EP negative. From the 730 collected swab samples we were able to demonstrate that the rtPCR test was 100% specific. In cases of cough the sensitivity on herd level of the rtPCR is 100%. On single animal level and in herds without cough the sensitivity was lower. In such cases, only a positive result would be proof for an infection with M. hyopneumoniae. Our study shows that the rtPCR on nasal swabs from live pigs allows a fast and accurate diagnosis in cases of suspected EP.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Methods of heat detection were compared in the Mid- Crest Area Cattle Evaluation Program (MACEP) heifer development program in the 1998-breeding season. A total of 189 heifers from thirteen consignors entered the program on November 10, 1997. These heifers were condition scored, hip height measured, weighed, disposition scored, booster vaccinated, and treated for parasites at the time of arrival. Determination of the heifer’s mature weight was made and a target of 65% of their mature weight at breeding was established. The ration was designed to meet this goal. The heifers were kept in a dry lot until all heifers were AI bred once. The heifers were periodically weighed and condition scored to monitor their gains and the ration was adjusted as needed. The estrus synchronization program consisted of an oral progesterone analog for 14 days; 17 days after completion of the progesterone analog treatment a single injection of prostaglandin was given and the heifers were then estrus detected. Two concurrent methods of estrus detection were utilized: 1) Ovatec â electronic breeding probe (probe), 2) HeatWatchâ estrus detection system (HW), and 3) a combination of probe and HW. Probe readings were obtained each 12 hours and the heifers were continuously monitored for estrus activity using the HW system. The probe was used as the primary estrus detection method and the HW system was used as a back-up system. Those heifers that did not demonstrate any estrus signs prior to 96 hours post prostaglandin treatment were mass inseminated at 96 hours. Post AI breeding, 151 of the heifers were placed on pasture and ran with clean-up bulls for 60 days. The remaining heifers left the program after the AI breeding was completed. Pregnancy to the AI breeding was determined by ultrasound on June 29, 1998. Results from using both probe and HW were 60% pregnant by AI, probe alone was 32% pregnant by AI, and HW alone was 27% pregnant by AI. The result of mass insemination was 20% pregnant by AI.