917 resultados para depth filtration
Resumo:
High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.
Resumo:
RÉSUMÉ Introduction L'effet des agents myorelaxants ainsi que des anticholinestérases sur la profondeur d'anesthésie a été étudié avec des résultats contradictoires. C'est pourquoi nous avons évalué l'effet de l'atracurium et de la néostigmine sur le BIS (bispectral index) ainsi que sur les potentiels auditives évoqués (middle-latency auditory evoked potentials, A-Line® autoregressive index [AAI]). Méthodes Après avoir obtenu l'accord du comité d'éthique local, nous avons étudié 40 patients ayant donné leur consentement écrit, ASA I-II, âgé de 18-69 ans. L'anesthésie générale a consisté en anesthésie intra-veineuse à objectif de concentration avec du propofol et du remifentanil. La fonction de la jonction neuromusculaire était monitorée en continu au moyen d'un électromyographe. Le BIS et l'AAI ont été enregistrés en continu. Après avoir atteint des valeurs stables au niveau du BIS, les patients ont été attribués à deux groupes par randomisation. Les patients du groupe 1 ont reçu 0.4 mg kg-1 d'atracurium et 5 minutes plus tard le même volume de NaCI 0.9%, dans le groupe 2 la séquence d'injection était inversée, le NaCI 0.9% en premier et l'atracurium en deuxième. Au moment où le premier « twitch » d'un train de quatre atteignait 10% de l'intensité avant la relaxation, les patients ont été randomisés une deuxième fois. Les patients du groupe N ont reçu 0.04 mg kg-1 de néostigmine et 0.01 rn9 kg-1 de glycopyrrolate alors que le groupe contrôle (G) ne recevait que 0.01 mg kg-] de glycopyrrolate. Résultats : L 'injection d'atracurium ou de NaCI 0.9% n'a pas eu d'effet sur le BIS ou l'AAI. Après l'injection de néostigmine avec glycopyrrolate, le BIS et I `AAI a augmenté de manière significative (changement maximal moyen du BIS 7.1 ± 7.5, P< 0.001, de l'AAI 9.7 ± 10.5, P< 0.001). Suite à l'injection de glycopyrrolate seule, le BIS et l'AAI a augmenté également (changement maximal moyen du BIS 2.2 ± 3.4, P< 0.008, de l'AAI 3.5 ± 5.7, P< 0.012), mais cette augmentation était significativement moins importante que dans le groupe N (P< 0.012 pour le BIS, P< 0.027 pour l'AAI). Conclusion Ces résultats laissent supposer que la néostigmine peut altérer la profondeur de l'anesthésie. La diminution de la profondeur d'anesthésie enregistrée par le BIS et l'AAI correspond probablement à une réapparition brusque d'une stimulation centrale liée à la proprioception. Au contraire, lors de la curarisation, le tonus musculaire diminue de manière beaucoup plus progressive, pouvant ainsi expliquer l'absence d'effet sur la profondeur d'anesthésie. ABSTRACT Background. Conflicting effects of neuromuscular blocking drugs and anticholinesterases on depth of anaesthesia have been reported. Therefore we evaluated the effect of atracurium and neostigmine on bispectral index (BIS) and middle-latency auditory evoked potentials (AAI). Methods. We studied 40 patients (ASA I-II) aged 18-69 yr. General anaesthesia consisted of propofol and remifentanil by target-controlled infusion and neuromuscular function was monitored by electromyography. When BIS reached stable values, patients were randomly assigned to one of two groups. Group I received atracurium 0.4 mg kg-1 and, 5 min later, the same volume of NaCl 0.9%; group 2 received saline first and then atracurium. When the first twitch of a train of four reached 10% of control intensity, patients were again randomized: one group (N) received neostigmine 0.04 mg kg-1 and glycopyrrolate 0.01 mg kg-1, and the control group (G) received only glycopyrrolate. Results. Injection of atracurium or NaCl 0.9% had no effect on BIS or AAI. After neostigmine¬glycopyrrolate, BIS and AAI increased significantly (mean maximal change of BIS 7.1 [SD 7.5], P<0.001; mean maximal change of AAI 9.7 [10.5], P<0.001). When glycopyrrolate was injected alone BIS and AAI also increased (mean maximal change of BIS 2.2 [3.4], P=0.008; mean maximal change of AAI 3.5 [5.7], P=0.012), but this increase was significantly less than in group N (P=0.012 for BIS; P=0.027 for AAI). Conclusion. These data suggest that neostigmine alters the state of propofol-remifentanil anaesthesia and may enhance recovery.
Resumo:
Purpose: To compare the efficacy and safety of a slowly resorbable glaucoma implant, Healaflow (HF) and Healon 5 (H5) as spacers injected into failing filtration blebs at the time of bleb needlings, augmented with MMC Methods: Eighty-four glaucoma patients with filtration bleb failure following glaucoma surgery (deep sclerectomy/ trabeculectomy) underwent bleb needling using either HF (n=44) or H5 (n=40) as an intrableb viscoelastic spacer. All needlings were augmented by MMC and performed in the operating room, by a single surgeon. The choice between HF and H5 was randomised. Postoperative data for IOP, number of glaucoma medications (GMs), antimetabolite injections (AMIs), bleb morphology and all complications were recorded at day 1 (D1), weeks 1 (W1), 4 (W4), month 6 (M6) and last visit. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline Results: Age was comparable between groups (HF vs H5; 66 vs 72 years; p=0.13*). There were no differences in mean postoperative IOP or GMs at any time point between groups (mean IOP = HF vs H5; prior to needling=19.8mmHg vs 18.7mmHg, p=0.48*; D1=10.4mmHg vs 10.2mmHg, p=0.85*; W1=12.3mmHg vs 13.8mmHg, p=0.33*; W4=15.7mmHg vs 15.1mmHg, p=0.69*; M6=14.3mmHg vs 13.8mmHg, p=0.69*. Mean GMs= HF vs H5; prior to needling=1.7 vs 1.7, p=0.96*; M6=0.9 vs 1.1, p=0.66*). Success rates were comparable between HF and H5 groups (74% vs 71%). Requirements for AMIs were similar between groups; post filtration surgery and prior to needling (mean AMIs 1.54 vs 1.65 p=0.82*) and within the first six months following needling ( 0.77 vs 0.65 p=0.70*). Complication rates were infrequent in both groups (9%, HF; 3%, H5) * two-sample t-test Conclusions: The early to mid-term success rates of needlings using intrableb spacers were high. However there were no differences observed between the use of crosslinked and high molecular weight sodium hyaluronate
Resumo:
Purpose To evaluate the safety and efficacy of infliximab as an antifibrotic agent after experimental glaucoma filtration surgery in rabbits. Methods In a randomized, prospective, masked-observer study, 30 New Zealand Albino rabbits underwent glaucoma filtration surgery. The animals were allocated to receive either intraoperative application of infliximab (group A) or mitomycin C (MMC) at a concentration of 0.2mg/ml (group B) or balanced salt solution (BSS, control)(group C). Different infliximab doses, namely 1.0mg, 2.0mg, 3.0mg, 4.0mg, 5.0mg in 0.1ml were applied. Bleb survival and characteristics were evaluated over a 30day period. The animals were killed on postoperative day 15 and 30. Histology of the operated eyes was performed to evaluate and grade the amount of scarring in each group.Cellular density was evaluated in each case. Results Infliximab did not appear to improve the outcome of filtration surgery in this model of glaucoma filtration surgery.There was a significant decrease in cellular density in the MMC group compared to the control group (p=0.0352). There was neither a significant decrease in cellular density between the infliximab group and the control group nor between the infliximab group and the MMC group. Overall there was no difference in terms of fibrosis between the three different groups. There was slightly less inflammation in the infliximab group, but not significant. Conclusions In this study intraoperative application of infliximab does not appear to be superior to the application of MMC or a control with regard to bleb survival and fibrosis. This study however demonstrates that intraoperative application of MMC significantly reduces the cellular density of the filtration bleb.
Resumo:
Purpose: Obesity is an established independent risk factor for chronic kidney disease. Thus, measurement of glomerular filtration rate (GFR) is important in this population. Traditionally, GFR has been indexed for body surface area (BSA), but this indexation may not be appropriate in obese individuals. Therefore, the objective of the study was to compare absolute GFR with GFR indexed for BSA and with GFR indexed for height. Methods and materials: The study was conducted in 66 families from the Seychelles islands that included several members with hypertension. GFR and effective renal plasma flow (ERPF) were measured using inulin and PAH clearances, respectively. Antihypertensive treatment, if used, was withheld 2 weeks before conducting the clearances. Participants with diabetes mellitus were excluded from the analysis. BSA was calculated using the Dubois formula. We assessed trend across BMI categories using a non parametric test. Results: Participants included 174 women and 127 men. The prevalence of hypertension was 61%, of which 68% were treated. The table shows that absolute GFR, GFR indexed for height, ERPF, filtration fraction were significantly higher across BMI categories. When GFR was indexed for BSA, the association between GFR and BMI categories was lost. Conclusion: Indexing GFR for BSA in overweight and obese individuals leads to a substantial underestimation of GFR. Filtration fraction, which does not depend on BSA, is higher in obese individuals, which suggests glomerular hyperfiltration. Indexing GFR for BSA therefore would mask the underlying glomerular hyperfiltration. As the number of nephrons does not increase with weight gain, absolute GFR represents a better marker of single nephron GFR and is more appropriate.
Resumo:
With inflation, there is no longer a completely adequate budget for highway construction and maintenance. Restricted budgets have generated development and implementation of pavement management programs. A need for management guidelines generated National Cooperative Highway Research Program Synthesis of Highway Practice 84, "Evaluation Criteria and Priority Setting for State Highway Programs". Traffic volumes and present conditions are two major factors in determining the priority of a proposed highway improvement. The Iowa DOT, Highway Division, Office of Materials has been conducting pavement condition inventory surveys on a three-year frequency since 1969 as input for pavement management. Development of substantial wheel rutting on paved roadways results in a potential hazard to highway safety. During periods of rain, these water-filled ruts may cause hydroplaning and loss of vehicle control. It is, therefore, imparitive that Iowa roadways be continually monitored for rut depths and further that this data be used in a pavement management program to determine priorities for rehabilitation or resurfacing.
Resumo:
We introduce a model of strategic thinking in games of initial response. Unlike standard level-k models, in this framework the player's `depth of reasoning' is endogenously determined, andit can be disentangled from his beliefs over his opponent's cognitive bound. In our approach,individuals act as if they follow a cost-benefit analysis. The depth of reasoning is a function ofthe player's cognitive abilities and his payoffs. The costs are exogenous and represent the gametheoretical sophistication of the player; the benefit instead is related to the game payoffs. Behavioris in turn determined by the individual's depth of reasoning and his beliefs about the reasoningprocess of the opponent. Thus, in our framework, payoffs not only affect individual choices inthe traditional sense, but they also shape the cognitive process itself. Our model delivers testableimplications on players' chosen actions as incentives and opponents change. We then test themodel's predictions with an experiment. We administer different treatments that vary beliefs overpayoffs and opponents, as well as beliefs over opponents' beliefs. The results of this experiment,which are not accounted for by current models of reasoning in games, strongly support our theory.Our approach therefore serves as a novel, unifying framework of strategic thinking that allows forpredictions across games.
Resumo:
We sought to assess the feasibility and reproducibility of performing tissue-based immune characterization of the tumor microenvironment using CT-compatible needle biopsy material. Three independent biopsies were obtained intraoperatively from one metastatic epithelial ovarian cancer lesion of 7 consecutive patients undergoing surgical cytoreduction using a 16-gauge core biopsy needle. Core specimens were snap-frozen and subjected to immunohistochemistry (IHC) against human CD3, CD4, CD8, and FoxP3. A portion of the cores was used to isolate RNA for 1) real-time quantitative (q)PCR for CD3, CD4, CD8, FoxP3, IL-10 and TGF-beta, 2) multiplexed PCR-based T cell receptor (TCR) CDR3 Vβ region spectratyping, and 3) gene expression profiling. Pearson's correlations were examined for immunohistochemistry and PCR gene expression, as well as for gene expression array data obtained from different tumor biopsies. Needle biopsy yielded sufficient tissue for all assays in all patients. IHC was highly reproducible and informative. Significant correlations were seen between the frequency of CD3+, CD8+ and FoxP3+ T cells by IHC with CD3ε, CD8A, and FoxP3 gene expression, respectively, by qPCR (r=0.61, 0.86, and 0.89; all p< 0.05). CDR3 spectratyping was feasible and highly reproducible in each tumor, and indicated a restricted repertoire for specific TCR Vβ chains in tumor-infiltrating T cells. Microarray gene expression revealed strong correlation between different biopsies collected from the same tumor. Our results demonstrate a feasible and reproducible method of immune monitoring using CT-compatible needle biopsies from tumor tissue, thereby paving the way for sophisticated translational studies during tumor biological therapy.
Resumo:
The aim of this work is to study the influence of several analytical parameters on the variability of Raman spectra of paint samples. In the present study, microtome thin section and direct (no preparation) analysis are considered as sample preparation. In order to evaluate their influence on the measures, an experimental design such as 'fractional full factorial' with seven factors (including the sampling process) is applied, for a total of 32 experiments representing 160 measures. Once the influence of sample preparation highlighted, a depth profile of a paint sample is carried out by changing the focusing plane in order to measure the colored layer under a clearcoat. This is undertaken in order to avoid sample preparation such a microtome sectioning. Finally, chemometric treatments such as principal component analysis are applied to the resulting spectra. The findings of this study indicate the importance of sample preparation, or more specifically, the surface roughness, on the variability of the measurements on a same sample. Moreover, the depth profile experiment highlights the influence of the refractive index of the upper layer (clearcoat) when measuring through a transparent layer.
Resumo:
This piece of work which is Identification of Research Portfolio for Development of Filtration Equipment aims at presenting a novel approach to identify promising research topics in the field of design and development of filtration equipment and processes. The projected approach consists of identifying technological problems often encountered in filtration processes. The sources of information for the problem retrieval were patent documents and scientific papers that discussed filtration equipments and processes. The problem identification method adopted in this work focussed on the semantic nature of a sentence in order to generate series of subject-action-object structures. This was achieved with software called Knowledgist. List of problems often encountered in filtration processes that have been mentioned in patent documents and scientific papers were generated. These problems were carefully studied and categorized. Suggestions were made on the various classes of these problems that need further investigation in order to propose a research portfolio. The uses and importance of other methods of information retrieval were also highlighted in this work.
Resumo:
Estimer la filtration glomérulaire chez les personnes âgées, tout en tenant compte de la difficulté supplémentaire d'évaluer leur masse musculaire, est difficile et particulièrement important pour la prescription de médicaments. Le taux plasmatique de la creatinine dépend à la fois de la fraction d'élimination rénale et extra-rénale et de la masse musculaire. Actuellement, pour estimer là filtration glomérulaire différentes formules sont utilisées, qui se fondent principalement sur la valeur de la créatinine. Néanmoins, en raison de la fraction éliminée par les voies tubulaires et intestinales la clairance de la créatinine surestime généralement le taux de filtration glomérulaire (GFR). Le but de cette étude est de vérifier la fiabilité de certains marqueurs et algorithmes de la fonction rénale actuellement utilisés et d'évaluer l'avantage additionnel de prendre en considération la masse musculaire mesurée par la bio-impédance dans une population âgée (> 70 ans) et avec une fonction rénale chronique compromise basée sur MDRD eGFR (CKD stades lll-IV). Dans cette étude, nous comparons 5 équations développées pour estimer la fonction rénale et basées respectivement sur la créatinine sérique (Cockcroft et MDRD), la cystatine C (Larsson), la créatinine combinée à la bêta-trace protéine (White), et la créatinine ajustée à la masse musculaire obtenue par analyse de la bio-impédance (MacDonald). La bio-impédance est une méthode couramment utilisée pour estimer la composition corporelle basée sur l'étude des propriétés électriques passives et de la géométrie des tissus biologiques. Cela permet d'estimer les volumes relatifs des différents tissus ou des fluides dans le corps, comme par exemple l'eau corporelle totale, la masse musculaire (=masse maigre) et la masse grasse corporelle. Nous avons évalué, dans une population âgée d'un service interne, et en utilisant la clairance de l'inuline (single shot) comme le « gold standard », les algorithmes de Cockcroft (GFR CKC), MDRD, Larsson (cystatine C, GFR CYS), White (beta trace protein, GFR BTP) et Macdonald (GFR = ALM, la masse musculaire par bio-impédance. Les résultats ont montré que le GFR (mean ± SD) mesurée avec l'inuline et calculée avec les algorithmes étaient respectivement de : 34.9±20 ml/min pour l'inuline, 46.7±18.5 ml/min pour CKC, 47.2±23 ml/min pour CYS, 54.4±18.2ml/min pour BTP, 49±15.9 ml/min pour MDRD et 32.9±27.2ml/min pour ALM. Les courbes ROC comparant la sensibilité et la spécificité, l'aire sous la courbe (AUC) et l'intervalle de confiance 95% étaient respectivement de : CKC 0 68 (055-0 81) MDRD 0.76 (0.64-0.87), Cystatin C 0.82 (0.72-0.92), BTP 0.75 (0.63-0.87), ALM 0.65 (0.52-0.78). ' En conclusion, les algorithmes comparés dans cette étude surestiment la GFR dans la population agee et hospitalisée, avec des polymorbidités et une classe CKD lll-IV. L'utilisation de l'impédance bioelectrique pour réduire l'erreur de l'estimation du GFR basé sur la créatinine n'a fourni aucune contribution significative, au contraire, elle a montré de moins bons résultats en comparaison aux autres equations. En fait dans cette étude 75% des patients ont changé leur classification CKD avec MacDonald (créatinine et masse musculaire), contre 49% avec CYS (cystatine C), 56% avec MDRD,52% avec Cockcroft et 65% avec BTP. Les meilleurs résultats ont été obtenus avec Larsson (CYS C) et la formule de Cockcroft.
Resumo:
Woven monofilament, multifilament, and spun yarn filter media have long been the standard media in liquid filtration equipment. While the energy for a solid-liquid separation process is determined by the engineering work, it is the interface between the slurry and the equipment - the filter media - that greatly affects the performance characteristics of the unit operation. Those skilled in the art are well aware that a poorly designed filter medium may endanger the whole operation, whereas well-performing filter media can make the operation smooth and economical. As the mineral and pulp producers seek to produce ever finer and more refined fractions of their products, it is becoming increasingly important to be able to dewater slurries with average particle sizes around 1 ¿m using conventional, high-capacity filtration equipment. Furthermore, the surface properties of the media must not allow sticky and adhesive particles to adhere to the media. The aim of this thesis was to test how the dirt-repellency, electrical resistance and highpressure filtration performance of selected woven filter media can be improved by modifying the fabric or yarn with coating, chemical treatment and calendering. The results achieved by chemical surface treatments clearly show that the woven media surface properties can be modified to achieve lower electrical resistance and improved dirt-repellency. The main challenge with the chemical treatments is the abrasion resistance and, while the experimental results indicate that the treatment is sufficiently permanent to resist standard weathering conditions, they may still prove to be inadequately strong in terms of actual use.From the pressure filtration studies in this work, it seems obvious that the conventional woven multifilament fabrics still perform surprisingly well against the coated media in terms of filtrate clarity and cake build-up. Especially in cases where the feed slurry concentration was low and the pressures moderate, the conventional media seemed to outperform the coated media. In the cases where thefeed slurry concentration was high, the tightly woven media performed well against the monofilament reference fabrics, but seemed to do worse than some of the coated media. This result is somewhat surprising in that the high initial specific resistance of the coated media would suggest that the media will blind more easily than the plain woven media. The results indicate, however, that it is actually the woven media that gradually clogs during the coarse of filtration. In conclusion, it seems obvious that there is a pressure limit above which the woven media looses its capacity to keep the solid particles from penetrating the structure. This finding suggests that for extreme pressures the only foreseeable solution is the coated fabrics supported by a strong enough woven fabric to hold thestructure together. Having said that, the high pressure filtration process seems to follow somewhat different laws than the more conventional processes. Based on the results, it may well be that the role of the cloth is most of all to support the cake, and the main performance-determining factor is a long life time. Measuring the pore size distribution with a commercially available porometer gives a fairly accurate picture of the pore size distribution of a fabric, but failsto give insight into which of the pore sizes is the most important in determining the flow through the fabric. Historically air, and sometimes water, permeability measures have been the standard in evaluating media filtration performance including particle retention. Permeability, however, is a function of a multitudeof variables and does not directly allow the estimation of the effective pore size. In this study a new method for estimating the effective pore size and open pore area in a densely woven multifilament fabric was developed. The method combines a simplified equation of the electrical resistance of fabric with the Hagen-Poiseuille flow equation to estimate the effective pore size of a fabric and the total open area of pores. The results are validated by comparison to the measured values of the largest pore size (Bubble point) and the average pore size. The results show good correlation with measured values. However, the measured and estimated values tend to diverge in high weft density fabrics. This phenomenon is thought to be a result of a more tortuous flow path of denser fabrics, and could most probably be cured by using another value for the tortuosity factor.