971 resultados para dental prosthesis design


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les mesures de contrôle de la contamination croisée sont principalement concentrées dans la salle opératoire dentaire alors que les articles transférés entre la clinique et le laboratoire dentaire et les instruments de laboratoire ont reçu peu d’attention. Cette étude vise à documenter l’application des mesures d’asepsie sur ces articles par les professionnels du domaine dentaire ainsi que leurs perceptions entourant ces mesures. Un questionnaire autoadministré et anonyme a été envoyé à un échantillon aléatoire des dentistes, denturologistes et directeurs de laboratoire dentaire qui étaient inscrits aux listes des ordres professionnels en juin 2008 dans la province de Québec. Des 1100 questionnaires envoyés, 376 ont été retournés remplis. Presque trois quarts (72,1 %) des répondants affirment faire l’asepsie des instruments de laboratoire et 74,9 %, la désinfection des articles transférés mais avec des pourcentages variables selon le groupe d’articles (empreintes, prothèses, etc.). Seulement 9,1 % de professionnels identifient de façon générale les articles désinfectés avant l’envoi. Plus de la moitié des professionnels (51,4 %) trouvent qu’ils n’ont pas assez d’information sur l’asepsie des articles transférés et 62,4 %, qu’elle est difficile à appliquer. Cette étude est la première réalisée auprès des trois groupes de professionnels et la première à étudier leurs perceptions entourant l’asepsie des articles transférés et de l’instrumentation de laboratoire. Nous avons démontré que l’application des mesures d’asepsie à ces articles par les professionnels du domaine dentaire n’est pas toujours conforme aux normes proposées et qu’il existe un besoin de renforcer leur application, surtout en ce qui a trait aux articles transférés.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: Self-rating provides a simple direct way of capturing perceptions of health. The objective of this study was to estimate the prevalence and associated factors of poor self-rated oral health among elders. Methods: National data from a cross-sectional population-based study with a multistage random sample of 4786 Brazilian older adults (aged 65-74) in 250 towns were analysed. Data collection included oral examinations (WHO 1997) and struct-ured interviews at elderly households. The outcome was measured by a single five-point-response-scale question dichotomized into `poor` (fair/poor/very poor) and `good` (good/very good) self-rated oral health. Data analyses used Poisson regression models stratified by sex. Results: The prevalence of poor self-rated oral health was 46.6% (95% CI: 45.2-48%) in the whole sample, 50.3% (48-52.5) in men and 44.2% (42.4-46) in women. Higher prevalence ratios (PR) were found in elders reporting unfavourable dental appearance (PR = 2.31; 95% CI: 2.02-2.65), poor chewing ability (PR = 1.64; CI: 1.48-1.8) and dental pain (PR = 1.44; CI: 1.04-1.23) in adjusted analysis. Poor self-perception was also associated with being men, black, unfavourable socioeconomic circumstances, unfavourable clinical oral health and with not using or needing a dental prosthesis. Conclusion: Assessment and understanding of self-rated oral health should take into account social factors, subjective and clinical oral symptoms.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A frequently encountered difficulty in oral prosthetics is associated with the loss of metallic alloys during the melting stage of the production of metal-ceramic replacement systems. Remelting such materials could impar their use in oral rehabilitation due to loss in esthetics, as well as in the chemical, physical, electrochemical and mechanical properties. Nowadays, the Ni-Cr-Mo-Ti alloy is widely used in metal-ceramic systems. Manufacturers state that this material can be remelted without significant alterations in its behavior, however little has been established as to the changes in the performance of this alloy after successive remelting, which is common practice in oral prosthetics. Therefore, the objective of this study was to evaluate possible changes in the esthetics and associated properties of metalceramic samples consisting of Ni-Cr-Mo-Ti and dental porcelain. Three to five remelting steps were carried out. The results revealed that Ni-Cr-Mo-Ti can be safely used even after three remelting steps. Further remelting significantly affect the characteristics of the alloys and should not be recommended for the manufacture of metal-ceramic systems

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit, as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles

Relevância:

80.00% 80.00%

Publicador:

Resumo:

At present, the material of choice for performing aesthetic dental prosthetic work is in the ceramic. Among them, the ceramic base of stabilized zirconia with 3% yttria (3Y - TZP) stand out for having excellent physical and mechanical properties. During the machining of blocks of zirconia in the laboratory to prepare the various types of prostheses, much of the material is given off in the form of powder, which is subsequently discarded. The waste of this material results in financial loss, reflecting higher final cost treatment for patients, as well as damage to the environment, thanks to the processes involved in the manufacture and disposal of the ceramic. This research, pioneered the recycling of zirconium oxide powder obtained during milling of dental crowns and bridges, we highlight the social and environmental aspects and aims to establish a protocol for the reuse of waste (powder of zirconia Zirkonzahn® system) discarded to obtain a new block of compacted zirconia to maintain the same mechanical and microstructural properties of commercial high-cost imported material. To compare with the commercial material, samples were uniaxially (20 MPa) and isostatically (100 MPa), and its mechanical and microstructural characterization was performed through tests of density, porosity, dilatometry, X-ray diffraction (XRD), hardness, fracture toughness, resistance to fracture electron microscopy (SEM) and analysis of grain size. The results observed in the samples were isostatically pressed similiares those obtained with samples from the commercial material demonstrating the viability of the process

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For a complete comprehension of the effect of tooth loss is necessary to listen to the patients that have it. This study, of qualitative approach, investigate, in the dental history of users of SUS, listening to his/her experiences with the services of dental care, the reason that lead his/her to dental lost and the repercussion of this in his/her life. The collect of data was made by narrative interview, obeying to a pre-defined schema. The subjects interviewed were six (three of urban zone and three of rural zone), all of them were users of Family Health Units. The criterions of inclusion were the followings: the presence of tooth lost (total lost in both dental arch or in one of them, or partial lost in at least six elements in one of the arches); age between 25 and 59; male or female; to live in municipal district of São Tomé/RN or Natal/RN. Based on previous interviews was elaborated the odontological history of each patient. Such narratives, systemized in odontological history, were analyzed taking as base the studies of Souza71 and the proposal of Schutze, suggested for Jovchelovitch, Bauer34. The results show that toothache was the main reason for the search of odontological care. The patients confront the ache with home-made medicaments, allopathic ones, and searching for dental care. The searching for exodontics was stimulated for geographic access difficulties or for repressed demand, which as a result produced the aggravation of the lesions and the discredit in restoration s treatment. The self-care practice of tooth-brush with juá or toothpaste and the controlled ingestion of sugar was not sufficient to avoid dental lost. Guilty sentiments were identified in relation with lack of care with teeth. The acceptance of dental lost as a natural factor is an important motivation in lack of pain and in the belief that it was a simple part of life in old age. Life with dental prosthesis makes clear the difference between which was natural and which was unnatural, and difficulties with the prosthesis appeared. The limitation of the prosthesis in its functional aspect can be compensated by esthetic restitution, making possible smiling expression. Starting with this study and considering the high number of dental lost, mainly in low-rent population, which live with toothless limitations or bad-quality prosthesis which do not rehabilitate adequately, we suggested the realization of qualitative researches which include, also, another actors in heath care services such as professionals and administrators

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: To evaluate user satisfaction and quality of prosthetic treatments performed in specialized dental clinics (CEOs) of Natal Metropolitan Region - RN. Methods: Cross-sectional study with subjects who underwent prosthetic CEOs in the cities of Natal, Macaíba, Parnamirim and Sao Goncalo do Amarante in the period 2007 to 2009. Data collection was performed by questionnaire, clinical examination of the oral cavity and examination of fabricated denture. This analysis involved the following aspects: retention, stability, aesthetics and prosthesis fixation. The variables are presented by means of absolute numbers and proportions. The determination of the association between the independent and dependent variables was conducted by the association of Chi-square test and Fisher exact test. Results: A total of 149 users, totaling 233 conventional dentures (148 upper and 85 lower). Most patients (56.4%) were rehabilitated with conventional complete dentures. The technical quality of the denture was regarded as satisfactory in the majority (52.7%), whereas the inferior dentures were rated as unsatisfactory in 90.5% of cases. Satisfaction with the prosthesis was 69.1% (N = 103). The average time to begin treatment was 3 months to receive while the prosthesis was 4 months old. The presence of injury from the upper prosthesis occurred in 21.5% of cases (N = 32), candidiasis being the most frequent (N = 18). The technical quality of the upper prosthesis (p=0,041), as well as retention (p=0,002) and stability (p<0,001) were significantly associated with user satisfaction. Conclusions: The specialized Dental clinics has been fulfilling its role of providing treatment of intermediate complexity for low-income population with the majority of satisfield patients, even when their dentures have problems of technical quality

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Este estudo apresenta resultados preliminares obtidos com um novo filtro permanente de veia cava, baseado no desenho de Greenfield, com três hastes prolongadas de um total de seis, para dar estabilidade central ao filtro na luz da veia cava. Neste artigo, relatamos sua avaliação clínica preliminar quanto à aplicabilidade, eficácia e segurança. de agosto de 2004 a dezembro de 2006, 15 filtros foram implantados em nove homens e seis mulheres, com idades variando de 38 a 79 anos (média de 57,8 anos). O acesso foi feito sempre por via transjugular. As indicações foram: trombose venosa proximal, com contra-indicação de anticoagulação em 12 pacientes; complicações hemorrágicas com anticoagulação em dois pacientes; e embolia pulmonar, apesar de anticoagulação adequada, em um paciente. Os filtros foram avaliados quanto à liberação, inclinação, mau posicionamento e perfuração de cava. No seguimento, avaliou-se trombose no local de acesso, tromboembolismo venoso recorrente, migração do filtro e trombose de cava pelo ultra-som. Nenhum paciente recebeu anticoagulantes no seguimento. O filtro foi liberado com sucesso em todos os casos sem mau posicionamento, inclinação, perfuração ou trombose de acesso. Os pacientes foram seguidos entre 3 e 23 meses (média de 11 meses). Nenhum paciente teve recorrência de tromboembolismo venoso. Não houve casos de trombose de veia cava ou migração do filtro. Óbito ocorreu em sete casos, todos relacionados com a moléstia de base. Os resultados preliminares indicam potencial eficácia e segurança do uso do novo filtro no período estudado.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar os adipócitos da gordura orbitária de coelhos após enucleação e evisceração. MÉTODOS: Foram estudados vinte e três espécimes de gordura orbitária, provenientes de 23 coelhos com idade de 42 dias, sendo 11 submetidos à cirurgia de enucleação e 12 à evisceração. Os animais foram sacrificados 30, 90 e 180 dias após a cirurgia, avaliando-se a gordura orbitária ao microscópio óptico (aumento de 200x) e usando o programa IpWin 32. A área média celular foi calculada a partir do número de adipócitos por campo e da área de cada adipócito, tendo sido comparados os resultados dos grupos (enucleação e evisceração) usando teste estatístico não paramétrico para avaliação da área dos adipócitos. RESULTADOS: Não houve diferença significativa entre a área média dos adipócitos quando considerado o procedimento cirúrgico (enucleação e evisceração), ou quando considerado o momento de sacrifício. CONCLUSÃO: Tendo em vista que a área dos adipócitos foi semelhante e não variou significativamente após a enucleação ou a evisceração, em período de observação de até 180 dias, a diminuição de volume orbitário que ocorre nas cavidades anoftálmicas deve ser conseqüência de outros mecanismos, como mudanças na distribuição espacial da gordura da órbita.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of implant-supported prosthesis to replace missing teeth became a predictable treatment. Although high success rate has been reported, implant treatment is suitable to complications, failures, and limitations such as peri-implant bone loss after implant loading. Stress evaluation on the bone-abutment-implant interface has been carried out to develop new designs of prosthetic platform and to understand the stress distribution in this interface. Several types of prosthetic platforms are available such as external and internal hexagon, Morse cone connection, and the concept of platform switching. Therefore, this study aimed to critically describe the different options of prosthetic platforms in implant dentistry, by discussing their biomechanical concepts, clinical use, and advantages and disadvantages. It was observed that all types of prosthetic platforms provided high success rate of the implant treatment by following a strict criteria of indication and limitation. In conclusion, a reverse planning of implant treatment is strongly indicated to reduce implant overload, and the use of advanced surgical-prosthetic techniques is required to obtain a long-term success of oral rehabilitations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purposes of this study were to photoelastically measure the biomechanical behavior of 4 implants retaining different cantilevered bar mandibular overdenture designs and to compare a fixed partial denture (FPD). A photoelastic model of a human edentulous mandible was fabricated, which contained 4 screw-type implants (3.75 x 10 mm) embedded in the parasymphyseal area. An FPD and 3 overdenture designs with the following attachments were evaluated: 3 plastic Hader clips, 1 Hader clip with 2 posterior resilient cap attachments, and 3 ball/O-ring attachments. Vertical occlusal forces of 100 N were applied between the central incisor and unilaterally to the right and left second premolars and second molars. Stresses that developed in the supporting structure were monitored photoelastically and recorded photographically. The results showed that the anterior loading, the overdenture with 3 plastic Hader clips, displayed the largest stress concentration at the medium implant. With premolar loading, the FPD and overdenture with 3 plastic Hader clips displayed the highest stresses to the ipsilateral terminal implant. With molar loading, the overdenture with 3 ball/O-ring attachments displayed the most uniform stress distribution in the posterior edentulous ridge, with less overloading in the terminal implant. It was concluded that vertical forces applied to the bar-clip overdenture and FPD created immediate stress patterns of greater magnitude and concentration on the ipsilateral implants, whereas the ball/O-ring attachments transferred minimal stress to the implants. The increased cantilever in the FPD caused the highest stresses to the terminal implant.