989 resultados para correction methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to differentiate the dentoalveolar and skeletal effects to better understand orthodontic treatment. We evaluated the treatment changes associated with the bionator and the removable headgear splint (RHS). Methods: The sample comprised 51 consecutively treated Class II patients from 1 office who had all been successfully treated with either a bionator (n = 17) or an RHS appliance (n = 17). Class II patients waiting to start treatment later served as controls (n = 17). A modified version of the Johnston pitchfork analysis was used to quantify the dentoalveolar and skeletal contributions to the anteroposterior correction at the levels of the molars and the incisors. Results: Both appliances significantly improved anteroposterior molar relationships (2.15 mm for the bionator, 2.27 mm for the RHS), primarily by dentoalveolar modifications (1.49 and 2.36 mm for the bionator and the RHS, respectively), with greater maxillary molar distalization in the RHS group. Overjet relationships also improved significantly compared with the controls (3.11 and 2.12 mm for the bionator and the RHS, respectively), due primarily to retroclination of the maxillary incisors (2.2 and 2.38 mm for the bionator and the RHS, respectively). The differences between overall corrections and dentoalveolar modifications for both molar and overjet relationships were explained by skeletal responses, with the bionator group showing significantly greater anterior mandibular displacement than the RHS group. Conclusions: The bionator and the RHS effectively corrected the molar relationships and overjets of Class II patients primarily by dentoalveolar changes. (Am J Orthod Dentofacial Orthop 2008; 134: 732-41)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An iterated deferred correction algorithm based on Lobatto Runge-Kutta formulae is developed for the efficient numerical solution of nonlinear stiff two-point boundary value problems. An analysis of the stability properties of general deferred correction schemes which are based on implicit Runge-Kutta methods is given and results which are analogous to those obtained for initial value problems are derived. A revised definition of symmetry is presented and this ensures that each deferred correction produces an optimal increase in order. Finally, some numerical results are given to demonstrate the superior performance of Lobatto formulae compared with mono-implicit formulae on stiff two-point boundary value problems. (C) 1998 Elsevier B.V. Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present paper deals with numerical corrections factors proposed as a function of the clearness index in order to correct the diffuse solar irradiance measured with the Melo-Escobedo Shadowring Measuring Method (ME shadowring). The global irradiance was measured by an Eppley - PSP pyranometer ; direct normal irradiance by an Eppley-NIP pyrheliometer fitted to a ST-3 sun tracking device and the diffuse irradiance by an Eppley-PSP pyranometer fitted to a ME shadowring. The validations were performed by the MBE and RMSE statistical indicators. The results showed that the numerical correction factors were appropriate to correct the shadowring diffuse irradiance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Patients with severe ptosis caused by poor or absent function of the levator muscle but with good frontalis muscle excursion usually benefit from a frontalis sling procedure. This is currently carried out using organic or inorganic material to connect the upper eyelid to the frontalis muscle. Methods: The aim of this study was to evaluate retrospectively 112 patients who underwent frontalis sling procedures between 1989 and 2011 using a preformed silicone implant suspensor to correct severe ptosis. Results: The results obtained using this technique were good or fair in 95.54 percent of the cases and poor in 4.46 percent of the cases. The authors discuss the results of the study and the cases in which the procedure should be indicated and highlight the advantages of the method. Conclusion: The availability of this low-cost sterile device, together with the fact that it is ready to use, requires less invasive surgery, saves time, and is sufficiently versatile to allow adjustments to be made at any time, makes the silicone eyelid sling an attractive choice for correcting ptosis. (Plast. Reconstr. Surg. 129: 453e, 2012.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to investigate, in a population of crossbred cattle, the obtainment of the non-additive genetic effects for the characteristics weight at 205 and 390 days and scrotal circumference, and to evaluate the consideration of these effects in the prediction of breeding values of sires using different estimation methodologies. In method 1, the data were pre-adjusted for the non-additive effects obtained by least squares means method in a model that considered the direct additive, maternal and non-additive fixed genetic effects, the direct and total maternal heterozygosities, and epistasis. In method 2, the non-additive effects were considered covariates in genetic model. Genetic values for adjusted and non-adjusted data were predicted considering additive direct and maternal effects, and for weight at 205 days, also the permanent environmental effect, as random effects in the model. The breeding values of the categories of sires considered for the weight characteristic at 205 days were organized in files, in order to verify alterations in the magnitude of the predictions and ranking of animals in the two methods of correction data for the non-additives effects. The non-additive effects were not similar in magnitude and direction in the two estimation methods used, nor for the characteristics evaluated. Pearson and Spearman correlations between breeding values were higher than 0.94, and the use of different methods does not imply changes in the selection of animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the effects produced by the MARA appliance in the treatment of Angle’s Class II, division 1 malocclusion. Methods: The sample consisted of 44 young patients divided into two groups: The MARA Group, with initial mean age of 11.99 years, treated with the MARA appliance for an average period of 1.11 years, and the Control Group, with initial mean age of 11.63 years, monitored for a mean period of 1.18 years with no treatment. Lateral cephalograms were used to compare the groups using cephalometric variables in the initial and final phases. For these comparisons, Student’s t test was employed. Results: MARA appliance produced the following effects: Maxillary growth restriction, no change in mandibular development, improvement in maxillomandibular relationship, increased lower anterior facial height and counterclockwise rotation of the functional occlusal plane. In the upper arch, the incisors moved lingually and retruded, while the molars moved distally and tipped distally. In the lower arch, the incisors proclined and protruded, whereas the molars mesialized and tipped mesially. Finally, there was a significant reduction in overbite and overjet, with an obvious improvement in molar relationship. Conclusions: It was concluded that the MARA appliance proved effective in correcting Angle’s Class II, division 1 malocclusion while inducing skeletal changes and particularly dental changes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The aim of this prospective clinical study was to investigate the cephalometric changes produced by bonded spurs associated with high-pull chincup therapy in children with Angle Class I malocclusion and anterior open bite. Methods: Thirty patients with an initial mean age of 8.14 years and a mean anterior open bite of 3.93 mm were treated with bonded spurs associated with chincup therapy for 12 months. An untreated control group of 30 subjects with an initial mean age of 8.36 years and a mean anterior open bite of 3.93 mm and the same malocclusion was followed for 12 months for comparison. Student t tests were used for intergroup comparisons. Results: The treated group demonstrated a significantly greater decrease of the gonial angle, and increase in overbite, palatal tipping of the maxillary incisors, and vertical dentoalveolar development of the maxillary and mandibular incisors compared with the control group. Conclusions: The association of bonded spurs with high-pull chincup therapy was efficient for the correction of the open bite in 86.7% of the patients, with a 5.23-mm (SD, 61.69) overbite increase.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare the classical neurosurgical technique with a new simplified technique for prenatal repair of a myelomeningocelelike defect in sheep. METHODS: A myelomeningocele-like defect (laminectomy and dural excision) was created in the lumbar region on day 90 of gestation in 9 pregnant sheep. Correction technique was randomized. In Group 1 the defect was corrected using the classic neurosurgical technique of three-layer suture (dura mater, muscle and skin closure) performed by a neurosurgeon. In Group 2, a fetal medicine specialist used a biosynthetic cellulose patch to protect the spinal cord and only the skin was sutured above it. Near term (day 132 of gestation) fetuses were sacrificed for pathological analysis. RESULTS: There were two miscarriages and one maternal death. In total, six cases were available for pathological analysis, three in each group. In Group 1, there were adherence of the spinal cord to the scar (meningo-neural adhesion) and spinal cord architecture loss with posterior funiculus destruction and no visualization of grey matter. In Group 2, we observed in all cases formation of a neo-dura mater, separating the nervous tissue from adjacent muscles, and preserving the posterior funiculus and grey matter. CONCLUSION: The new simplified technique was better than the classic neurosurgical technique. It preserved the nervous tissue and prevented the adherence of the spinal cord to the scar. This suggests the current technique used for the correction of spina bifida in humans may need to be reassessed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis some multivariate spectroscopic methods for the analysis of solutions are proposed. Spectroscopy and multivariate data analysis form a powerful combination for obtaining both quantitative and qualitative information and it is shown how spectroscopic techniques in combination with chemometric data evaluation can be used to obtain rapid, simple and efficient analytical methods. These spectroscopic methods consisting of spectroscopic analysis, a high level of automation and chemometric data evaluation can lead to analytical methods with a high analytical capacity, and for these methods, the term high-capacity analysis (HCA) is suggested. It is further shown how chemometric evaluation of the multivariate data in chromatographic analyses decreases the need for baseline separation. The thesis is based on six papers and the chemometric tools used are experimental design, principal component analysis (PCA), soft independent modelling of class analogy (SIMCA), partial least squares regression (PLS) and parallel factor analysis (PARAFAC). The analytical techniques utilised are scanning ultraviolet-visible (UV-Vis) spectroscopy, diode array detection (DAD) used in non-column chromatographic diode array UV spectroscopy, high-performance liquid chromatography with diode array detection (HPLC-DAD) and fluorescence spectroscopy. The methods proposed are exemplified in the analysis of pharmaceutical solutions and serum proteins. In Paper I a method is proposed for the determination of the content and identity of the active compound in pharmaceutical solutions by means of UV-Vis spectroscopy, orthogonal signal correction and multivariate calibration with PLS and SIMCA classification. Paper II proposes a new method for the rapid determination of pharmaceutical solutions by the use of non-column chromatographic diode array UV spectroscopy, i.e. a conventional HPLC-DAD system without any chromatographic column connected. In Paper III an investigation is made of the ability of a control sample, of known content and identity to diagnose and correct errors in multivariate predictions something that together with use of multivariate residuals can make it possible to use the same calibration model over time. In Paper IV a method is proposed for simultaneous determination of serum proteins with fluorescence spectroscopy and multivariate calibration. Paper V proposes a method for the determination of chromatographic peak purity by means of PCA of HPLC-DAD data. In Paper VI PARAFAC is applied for the decomposition of DAD data of some partially separated peaks into the pure chromatographic, spectral and concentration profiles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The subject of this Ph.D. research thesis is the development and application of multiplexed analytical methods based on bioluminescent whole-cell biosensors. One of the main goals of analytical chemistry is multianalyte testing in which two or more analytes are measured simultaneously in a single assay. The advantages of multianalyte testing are work simplification, high throughput, and reduction in the overall cost per test. The availability of multiplexed portable analytical systems is of particular interest for on-field analysis of clinical, environmental or food samples as well as for the drug discovery process. To allow highly sensitive and selective analysis, these devices should combine biospecific molecular recognition with ultrasensitive detection systems. To address the current need for rapid, highly sensitive and inexpensive devices for obtaining more data from each sample,genetically engineered whole-cell biosensors as biospecific recognition element were combined with ultrasensitive bioluminescence detection techniques. Genetically engineered cell-based sensing systems were obtained by introducing into bacterial, yeast or mammalian cells a vector expressing a reporter protein whose expression is controlled by regulatory proteins and promoter sequences. The regulatory protein is able to recognize the presence of the analyte (e.g., compounds with hormone-like activity, heavy metals…) and to consequently activate the expression of the reporter protein that can be readily measured and directly related to the analyte bioavailable concentration in the sample. Bioluminescence represents the ideal detection principle for miniaturized analytical devices and multiplexed assays thanks to high detectability in small sample volumes allowing an accurate signal localization and quantification. In the first chapter of this dissertation is discussed the obtainment of improved bioluminescent proteins emitting at different wavelenghts, in term of increased thermostability, enhanced emission decay kinetic and spectral resolution. The second chapter is mainly focused on the use of these proteins in the development of whole-cell based assay with improved analytical performance. In particular since the main drawback of whole-cell biosensors is the high variability of their analyte specific response mainly caused by variations in cell viability due to aspecific effects of the sample’s matrix, an additional bioluminescent reporter has been introduced to correct the analytical response thus increasing the robustness of the bioassays. The feasibility of using a combination of two or more bioluminescent proteins for obtaining biosensors with internal signal correction or for the simultaneous detection of multiple analytes has been demonstrated by developing a dual reporter yeast based biosensor for androgenic activity measurement and a triple reporter mammalian cell-based biosensor for the simultaneous monitoring of two CYP450 enzymes activation, involved in cholesterol degradation, with the use of two spectrally resolved intracellular luciferases and a secreted luciferase as a control for cells viability. In the third chapter is presented the development of a portable multianalyte detection system. In order to develop a portable system that can be used also outside the laboratory environment even by non skilled personnel, cells have been immobilized into a new biocompatible and transparent polymeric matrix within a modified clear bottom black 384 -well microtiter plate to obtain a bioluminescent cell array. The cell array was placed in contact with a portable charge-coupled device (CCD) light sensor able to localize and quantify the luminescent signal produced by different bioluminescent whole-cell biosensors. This multiplexed biosensing platform containing whole-cell biosensors was successfully used to measure the overall toxicity of a given sample as well as to obtain dose response curves for heavy metals and to detect hormonal activity in clinical samples (PCT/IB2010/050625: “Portable device based on immobilized cells for the detection of analytes.” Michelini E, Roda A, Dolci LS, Mezzanotte L, Cevenini L , 2010). At the end of the dissertation some future development steps are also discussed in order to develop a point of care (POCT) device that combine portability, minimum sample pre-treatment and highly sensitive multiplexed assays in a short assay time. In this POCT perspective, field-flow fractionation (FFF) techniques, in particular gravitational variant (GrFFF) that exploit the earth gravitational field to structure the separation, have been investigated for cells fractionation, characterization and isolation. Thanks to the simplicity of its equipment, amenable to miniaturization, the GrFFF techniques appears to be particularly suited for its implementation in POCT devices and may be used as pre-analytical integrated module to be applied directly to drive target analytes of raw samples to the modules where biospecifc recognition reactions based on ultrasensitive bioluminescence detection occurs, providing an increase in overall analytical output.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work of thesis is the refined estimations of source parameters. To such a purpose we used two different approaches, one in the frequency domain and the other in the time domain. In frequency domain, we analyzed the P- and S-wave displacement spectra to estimate spectral parameters, that is corner frequencies and low frequency spectral amplitudes. We used a parametric modeling approach which is combined with a multi-step, non-linear inversion strategy and includes the correction for attenuation and site effects. The iterative multi-step procedure was applied to about 700 microearthquakes in the moment range 1011-1014 N•m and recorded at the dense, wide-dynamic range, seismic networks operating in Southern Apennines (Italy). The analysis of the source parameters is often complicated when we are not able to model the propagation accurately. In this case the empirical Green function approach is a very useful tool to study the seismic source properties. In fact the Empirical Green Functions (EGFs) consent to represent the contribution of propagation and site effects to signal without using approximate velocity models. An EGF is a recorded three-component set of time-histories of a small earthquake whose source mechanism and propagation path are similar to those of the master event. Thus, in time domain, the deconvolution method of Vallée (2004) was applied to calculate the source time functions (RSTFs) and to accurately estimate source size and rupture velocity. This technique was applied to 1) large event, that is Mw=6.3 2009 L’Aquila mainshock (Central Italy), 2) moderate events, that is cluster of earthquakes of 2009 L’Aquila sequence with moment magnitude ranging between 3 and 5.6, 3) small event, i.e. Mw=2.9 Laviano mainshock (Southern Italy).