1000 resultados para consumo de oxigênio


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The oil activity in the Rio Grande do Norte State (RN) is a permanent threat to coastal ecosystems, particularly mangroves, with the possibility of oil spills. In this context, the objective of this study was to evaluate the potential resistance of the mangrove environment of a possible spill. Were selected and isolated microorganisms degrading oil by the technique of enrichment cultures and formation of a bacterial consortium. The kinetic study of the consortium was held in rotary incubator shaken at 150 rpm and 30° C. Samples were taken at intervals of 4 hours for analysis of cell concentration and surface tension. The biodegradation was monitored using two methods of respirometry: manometric (OxiTop-C ®) and conductivimetry, where the biodegradation of oil was estimated indirectly by oxygen consumption and CO2 production, respectively. Furthermore, it was used a full 2² factorial design with triplicate at central point to the runs that used the conductivimetric methodology.. The technique of enrichment cultures allowed to obtain thirteen bacterial strains. Kinetic study of the consortium, we can showed the absence of the lag phase, reaching a maximum cell concentration of 2.55 g / L at 16 h of cultivation and a reduction on surface tension. When we adopted the methodology of OxiTop-C was detected a band indicating biodegradability (1% oil v/v), however when we used the conductivimetry methodology did not observe any band that would indicate effective biodegradation. By monitoring a process of biodegradation is necessary to observe the methodology will be adopted to evaluate the biodegradation process, since for the same conditions adopted different methodologies can produce different results. The oil-degrading isolates from soils of the mangrove estuary Potengi / RN are largely to be used in bioremediation strategies of these places, in the case of a possible oil spill, or it can be used in the treatment of waste oil generated in saline environments, since they are optimized the conditions of the tests so that the efficiency of biodegradation reach the minimum level suggested by the standarts

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Petroleum Refinery wastewaters (PRW) have hart-to-degrade compounds, such as: phenols, ammonia, cyanides, sulfides, oils and greases and the mono and polynuclear aromatic hydrocarbons: benzene, toluene and xylene (BTX), acenaphthene, nitrobenzene and naphtalene. It is known that the microrganisms activity can be reduced in the presence of certain substances, adversely affecting the biological process of wastewater treatment. This research was instigated due the small number of studies regarding to this specific topic in the avaiable literature. This body of work ims to evaluate the effect of toxic substances on the biodegradability of the organic material found in PRW. Glucose was chosen as the model substrate due to its biodegradable nature. This study was divided into three parts: i) a survey of recalcitants compounds and the removal of phenol by using both biological and photochemical-biological processes; ii) biomass aclimation and iii) evaluation of the inhibitory effect certain compounds have on glucose biodegradation. The phenol degradation experiments were carried out in an activity sludge system and in a photochemical reactor. The results showed the photochemical-biological process to be more effective on phenol degradation, suggesting the superioruty of a combined photochemical-biological treatment when compared with a simple biological process for phenol removal from industry wastewaters. For the acclimation step, was used an activated sludge from industrial wastewaters. A rapid biomass aclimation to a synthetic solution composed of the main inhibitory compouns fpund in a PRW was obtained using the following operation condition: (pH = 7,0; DO ≥ 2,0 mg/L; RS = 20 days e qH = 31,2 and 20,4 hours), The last part was consisted of using respirometry evaluation toxicity effects of selected compounds over oxygen uptake rate to adaptated and non adaptated biomass in the presence of inhibitory compounds. The adaptated sludge showed greater degration capacity, with lower sensibility to toxic effects. The respirometry has proved to be very practical, as the techiniques used were simple and rapid, such as: Chemical Oxygen Demand (COD), Dissolved Oxygen (DO), and Volatile Suspended Solids (VSS). Using the latter it is possible to perform sludge selection to beggingthe process; thus allowing its use for aerobic treatment system`s behacior prediction

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The improper disposal of nitrogen in receiving water courses causes problems such as toxicity to living beings through the consumption of oxygen to meet the nitrogen demand, eutrophication and nitrate contamination of aquifers. For this reason it is often necessary to be carried out complementary treatment of wastewater to eliminate or reduce the concentration of this compound in the wastewater. The objective of this study is to evaluate the biological removal of nitrogen compounds using submerged aerated and anoxic filters as post-treatment of an anaerobic system, with low cost and innovative technology, which in previous studies has shown high removal efficiency of organic matter and great potential biological nitrogen compounds removal. The simple design with perforated hoses for air distribution and filling with plastic parts proved to be very efficient in relation to organic matter removal and nitrification. The system presented, in the best stage, efficiency in converting ammonia to nitrate by 71%, and produced a final effluent concentration below 10 mg / L of NH3-N. In addition, carbon concentration was removed by 77%, producing final effluent with 24 mg/L COD. However, denitrification in anoxic filter was not effective even with the addition of an external carbon source. There was a reduction of up to 56% of nitrogen caused by the process of simultaneous nitrification and denitrification (SND). The high voids space presented by this type of support material coupled with direct aeration of the sludge, allows the respiration of biomass retained between the endogenous phase, increased cell retention time and sludge retention capacity, producing a final effluent with turbidity less than 5 UT and total suspended solids around 5.0 mg/L

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Poucos são os estudos que possibilitam verificar quais as respostas fisiológicas são associadas ao desempenho em uma amostra de ciclistas de elite nacional. Portanto, o objetivo do presente estudo foi determinar e relacionar diferentes índices fisiológicos aeróbios com o desempenho em testes contra relógio de 4 e 20km em ciclistas de alto nível. A amostra foi composta por 14 ciclistas profissionais de elite nacional do sexo masculino (28,5 ± 4,7 anos, 73,47 ± 8,29 kg, 176 ± 6,76 cm), que realizaram um teste progressivo em laboratório para a determinação do consumo máximo de oxigênio (VO2max: 62,23 ± 8,28 ml·kg·min-1), intensidade relativa ao VO2max (iVO2max: 500,83 ± 58,65 w), economia de movimento (EM: 0,1166 ± 0,0362 ml·kg·min·w-1) e 1º e 2º limiares ventilatórios (LV1: 348,21 ± 43,26 w; LV2: 417,86 ± 60,79 w, respectivamente). Também foram submetidos a duas provas de 4 e 20km contra relógio. Para correlação entre os índices fisiológicos e desempenho, foi utilizado o coeficiente de correlação de Pearson (p< 0,05). Não foi encontrada correlação entre os índices fisiológicos (VO2max absoluto e relativo, iVO2max, EM, LV1 e LV2) e o desempenho de 4km (r= 0.38; 0.16; -0.33; 0.20; -0.50; -0.20, respectivamente) e 20km (r= 0.24; 0.01; -0.13; -0.12; -0.48; -0.19, respectivamente) contra relógio em atletas de alto nível. Estes resultados sugerem que tais variáveis não apresentam capacidade de explicar o desempenho em provas de contra relógio nas respectivas distâncias, provavelmente, devido à homogeneidade entre os sujeitos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Backgroud: Obesity is a major public health problem and is related to the low physical capacity when obese are compared to no-obese people, however the cause of this limitation is not completely understood. The measurement associated of physiological response to the telemetric 6MWT adds information of metabolic and respiratory system for diagnose of the functional limitation. Objective: Analyze physiological, metabolic and ventilatory responses in women with different body fat during the 6MWT. Methods: 32 women (8 non-obese, 8 Overweight, 8 Obese and 8 morbidly obese) were evaluated for anthropometry, lung function and exercise capacity. Results: Morbidly obese walked the shortest distance (400.2±38.7m), had lower VO2/Kg (12.75±3.20l/Kg/min) and lower R (0.74± 0.11) in the 6MWT compared to other groups. Analyses of metabolic (VO2 and VCO2) and respiratory (VE, VT and BF) during the test did not identify differences between groups. The evaluation of cardiac function (O2 pulse) found higher values in the OM (12.3 ± 4.9ml/bat). Conclusion: The OM had worse performance in the 6MWT compared to other groups. The physical performance may be reduced in this population related to a protocol-dependent response because the speed of 6MWT is self-adjusted allows the individual himself select the intensity of the test, making it set at a speed where there is energy saving

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The term fatigability concerns the degree of fatigue associated with performing an activity of any type (physical, mental, emotional and / or social). Recently scales for assessing fatigue in the English language were created, however, gaps exist regarding the validity of these scales in relation to oxygen consumption and levels of perceived fatigue. Objective: To investigate the validity of perceived fatigability scale in older women frail and non-frail by the expired gases kinetics. Methods: This is a study of type validation, where were evaluated 48 elderly. The evaluation was conducted at two different sessions. In the first, data were collected demographic partners, as well as assessment of cognitive function, physical health, and the phenotype of frailty. The second was composed by the test 6-minute walk (6MWT) associated the expired gases kinects and assessment of perceived fatigability. Statistical analysis was performed a descriptive analysis and then we used the Pearson correlation test to evaluate the relationship between the measure of perceived fatigue and variables oxygen consumption (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER)before and after 6MWT. We used a linear regression model initially considering the following explanatory variable: age, Body Mass Index (BMI), presence of frailty, comorbidities, level of physical activity, distance covered in the 6MWT , the energy cost of walking and severity of fatigability on performance. Results: The final sample consisted of 44 elderly women, 4 elderly were excluded because they didn t complete all phases of this study. The mean age obtained was 75 years (± 7.2 years). There was no significant correlation between fatigability measures and the values of VO2 ( r = .09 , p = .56 ) , VCO2 ( r = .173 , p = .26 ) , RER ( r = - .121 , p = .43 ). The final linear regression model showed that the energy cost of walking, the usual level of physical activity and the performance severity of fatigability explained 83.5 % (R2 = 0.835, p < 0.01) of the variation in the perceived fatigability. Conclusion: Our findings indicate a relationship between greater severity of fatigability and lower levels of physical activity and increased energy cost in walking, suggesting that the fatigability analyses using a simple numeric scale is valid and viable for assessment of fatigue in older women

Relevância:

60.00% 60.00%

Publicador:

Resumo:

obesity affects rightly functional capacity diminishing the cardiovascular system efficiency and oxygen uptake (VO2). Field tests, such as, Incremental Shuttle Walking Test (ISWT) and Six Minute Walk Test (6MWT) has been employed as alternative of Cardiopulmonary Exercise Test (CPX), to functional assessing for conditions which transport of oxygen to peripheral is diminished. Nevertheless, the knowing about metabolic variables response in real time and it comparing among different maximal and submaximal tests in obese is absent. Aim: to compare cardiopulmonary, metabolic response during CPX, ISWT and 6MWT and to analyse it influence of adiposity markers in obese. Material e Method: crosssectional, prospective study. Obese included if: (BMI>30Kg/m2; FVC>80%), were assessed as clinical, anthropometric (BMI, body adiposity index-BAI, waist-WC, hip- HC and neck-NC circumferences) and spirometry (forced vital capacity-FVC, Forced expiratory volume-1°second-FEV1, maximal voluntary ventilation-MVV) variables. Obese performed the sequence of tests: CPX, ISWT and 6MWT. Throughout tests was assessed breath-by-breath by telemetry system (Cortex-Biophysik-Metamax3B) variables; oxygen uptake on peak of activity (VO2peak); carbon dioxide production (VCO2); Volume Expiratory (VE); ventilatory equivalents for VO2 (VE/VO2) and CO2 (VE/VCO2); respiratory exchange rate (RER) and perceived effort-Borg6-20). Results: 15 obese (10women) 39.4+10.1years, normal spirometry (%CVF=93.7+9.7) finished all test. They have BMI (43.5+6.6kg/m2) and different as %adiposity (BAI=50.0+10.5% and 48.8+16.9% respectively women and men). Difference of VO2ml/kg/min and %VO2 were finding between CPX (18.6+4.0) and 6MWT (13.2+2.5) but not between ISWT (15.4+2.9). Agreement was found for ISWT and CPX on VO2Peak (3.2ml/kg/min; 95%; IC-3.0 9.4) and %VO2 (16.4%). VCO2(l/min) confirms similarity in production for CPX (2.3+1.0) and ISWT (1.7+0.7) and difference for 6MWT (1.4+0.6). WC explains more the response of CPX and ISWT than other adiposity markers. Adiposity diminishes 3.2% duration of CPX. Conclusion: ISWT promotes similar metabolic and cardiovascular response than CPX in obese. It suggesting that ISWT could be useful and reliable to assess oxygen uptake and functional capacity in obese

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Informações experimentais e clínicas têm sugerido que os b-bloqueadores apresentam efeitos hemodinâmicos importantes e protetores durante o ato anestésico-cirúrgico. O objetivo deste trabalho é revisar as informações farmacológicas e clínicas dos b-bloqueadores para sua utilização adequada na medicina per-operatória. CONTEÚDO: Os b-bloqueadores seletivos inibem preferencialmente os b1-receptores reduzindo a freqüência e inotropismo cardíacos e determinando redução no consumo de oxigênio do miocárdio. Os b-bloqueadores não seletivos inibem também os b2-receptores, aumentando a resistência bronquiolar e vascular periférica. Alguns b-bloqueadores são, também, vasodilatadores. O tratamento prolongado com os b-bloqueadores aumenta a densidade dos b-receptores na membrana celular, o que pode explicar a hiperatividade simpática que pode ocorrer durante a parada do tratamento desses medicamentos. em cirurgia não cardíaca, os efeitos benéficos do b-bloqueadores em pacientes hipertensos ou nos que apresentam doença coronariana têm sido demonstrados, com redução da incidência de isquemia miocárdica no pós-operatório e da mortalidade durante o período de dois anos que se segue à operação. CONCLUSÕES: O tratamento com b-bloqueadores deve ser mantido até o período da manhã da operação, exceto nos pacientes com sinais de intolerância à droga, como hipotensão ou bradicardia importante. Os b-bloqueadores exercem efeito benéfico na recuperação pós-operatória de pacientes com doenças cardiovasculares ou nos que apresentam fatores de risco. Por isso, o emprego desses medicamentos é importante na medicina per-operatória e deve ser ampliado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Diversos modelos experimentais têm sido utilizados para ilustrar as alterações hemodinâmicas e metabólicas que ocorrem durante o choque hemorrágico. O objetivo da pesquisa é o de observar os comportamentos hemodinâmicos e metabólicos que acontecem em um modelo seqüencial e progressivo de choque hemorrágico no cão, verificando quais índices alteram-se mais precocemente. MÉTODO: O estudo foi realizado em 13 cães sob anestesia venosa total com pentobarbital sódico, em normoventilação e previamente esplenectomizados. Os animais não foram hidratados e a velocidade do sangramento foi ditada pela pressão arterial em que o animal se encontrava. Os atributos estudados foram divididos em hemodinâmicos (freqüência cardíaca - FC, pressão arterial média - PAM, índice de resistência vascular sistêmica - IRVS, índice sistólico - IS, índice cardíaco - IC, índice de choque - I.choque, índice de trabalho sistólico do ventrículo esquerdo - ITSVE, pressão capilar pulmonar - PCP, pressão venosa central - PVC) e metabólicos (saturação venosa mista - SvO2, pressão venosa de oxigênio - PvO2, transporte de oxigênio - DO2, consumo de oxigênio - VO2, extração de oxigênio - TEO2, lactato sérico). A coleta de dados e os atributos foram estudados em 6 momentos distintos, sendo M1, o momento controle e os outros momentos correspondentes a decréscimos gradativos de 10% da volemia calculada para cada animal. RESULTADOS: A hemorragia determinou diminuição significativa da FC somente em M6; queda da PAM, IC, IS e ITSVE a cada momento estudado; discreta alteração da PVC e PCP em cada momento; diminuição da PvO2 e da SvO2 nos momentos estudados; redução do DO2, estabilização do VO2 e elevação da TEO2 nos momentos; o índice de choque apresentou elevação até M3, diminuição em M4 e nova elevação até M6; o IRVS elevou-se até M6, ficou inalterado em M5 e apresentou diminuição significativa em M6; o lactato apresentou elevações a partir de M5 e M6. CONCLUSÕES: Considerou-se que a pressão arterial média, freqüência cardíaca, pressão venosa central e pressão capilar pulmonar não refletem o real estado volêmico dos cães no nosso modelo experimental e que o transporte, consumo e a taxa de extração de oxigênio são parâmetros úteis na determinação da reversibilidade e prognóstico do choque hemorrágico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Determinar a acurácia das variáveis: tempo de escada (tTE), potência de escada (PTE), teste de caminhada (TC6) e volume expiratório forçado (VEF1) utilizando o consumo máximo de oxigênio (VO2máx) como padrão-ouro. MÉTODOS: Os testes foram realizados em 51 pacientes. O VEF1 foi obtido através da espirometria. O TC6 foi realizado em corredor plano de 120m. O TE foi realizado em escada de 6 lances obtendo-se tTE e PTE. O VO2máx foi obtido por ergoespirometria, utilizando o protocolo de Balke. Foram calculados a correlação linear de Pearson (r) e os valores de p, entre VO2máx e variáveis. Para o cálculo da acurácia, foram obtidos os pontos de corte, através da curva característica operacional (ROC). A estatística Kappa (k) foi utilizada para cálculo da concordância. RESULTADOS: Obteve-se as acurácias: tTE - 86%, TC6 - 80%, PTE - 71%, VEF1(L) - 67%, VEF1% - 63%. Para o tTE e TC6 combinados em paralelo, obteve-se sensibilidade de 93,5% e em série, especificidade de 96,4%. CONCLUSÃO: O tTE foi a variável que apresentou a melhor acurácia. Quando combinados o tTE e TC6 podem ter especificidade e sensibilidade próxima de 100%. Estes testes deveriam ser mais usados rotineiramente, especialmente quando a ergoespirometria para a medida de VO2máx não é disponível.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O principal objetivo deste estudo foi comparar a intensidade correspondente à máxima fase estável de lactato (MLSS) e a potência crítica (PC) durante o ciclismo em indivíduos bem treinados. Seis ciclistas do sexo masculino (25,5 ± 4,4 anos, 68,8 ± 3,0kg, 173,0 ± 4,0cm) realizaram em diferentes dias os seguintes testes: exercício incremental até a exaustão para a determinação do pico de consumo de oxigênio (VO2pico) e sua respectiva intensidade (IVO2pico); cinco a sete testes de carga constante para a determinação da MLSS e da PC; e um exercício até a exaustão na PC. A MLSS foi considerada com a maior intensidade de exercício onde a concentração de lactato não aumentou mais do que 1mM entre o 10º e o 30º min de exercício. Os valores individuais de potência (95, 100 e 110% IVO2pico) e seu respectivo tempo máximo de exercício (Tlim) foram ajustados a partir do modelo hiperbólico de dois parâmetros para a determinação da PC. Embora altamente correlacionadas (r = 0,99; p = 0,0001), a PC (313,5 ± 32,3W) foi significantemente maior do que a MLLS (287,0 ± 37,8W) (p = 0,0002). A diferença percentual da PC em relação à MLSS foi de 9,5 ± 3,1%. No exercício realizado na PC, embora tenha existido componente lento do VO2 (CL = 400,8 ± 267,0 ml.min-1), o VO2pico não foi alcançado (91,1 ± 3,3 %). Com base nesses resultados pode-se concluir que a PC e a MLSS identificam diferentes intensidades de exercício, mesmo em atletas com elevada aptidão aeróbia. Entretanto, o percentual da diferença entre a MLLS e PC (9%) indica que relação entre esses dois índices pode depender da aptidão aeróbia. Durante o exercício realizado até a exaustão na PC, o CL que é desenvolvido não permite que o VO2pico seja alcançado.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJETIVO: Determinar os efeitos do estado e especificidade de treinamento aeróbio na relação entre o percentual do consumo máximo de oxigênio (%VO2max) e o percentual da frequência cardíaca máxima (%FCmax) durante o exercício incremental realizado no cicloergômetro. MÉTODOS: Sete corredores, 9 ciclistas, 11 triatletas e 12 sedentários, todos do sexo masculino e aparentemente saudáveis, foram submetidos a um teste incremental até a exaustão no cicloergômetro. Regressões lineares entre %VO2max e %FCmax foram determinadas para cada indivíduo. Com base nessas regressões, foram calculados %FCmax correspondentes a determinados %VO2max (50, 60, 70, 80 e 90%) de cada participante. RESULTADOS: Não foram encontradas diferenças significantes entre todos os grupos nos %FCmax para cada um dos %VO2max avaliados. Analisando-se os voluntários como um único grupo, as médias dos %FCmax correspondentes a 50, 60, 70, 80 e 90% %VO2max foram 67, 73, 80, 87, e 93%, respectivamente. CONCLUSÃO: Nos grupos analisados, a relação entre o %VO2max e %FCmax durante o exercício incremental no ciclismo não é dependente do estado e especificidade do treinamento aeróbio.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo do presente estudo foi desenvolver um snorquel (SNQ) de baixo custo para mensuração de parâmetros cardiorrespiratórios em natação. Para isso, a máscara do analisador de gases VO2000 (MASC) foi adaptada a um SNQ desenvolvido artesanalmente com espaço morto de 250ml. Oito participantes foram submetidos a dois testes incrementais (TI) em cicloergômetro utilizando a MASC e o SNQ. Os TI foram realizados até a exaustão voluntária e foram compostos por estágios de 3min com carga inicial e incrementos de 35W. em ambas as situações, amostras gasosas foram coletadas em intervalos de 10s para determinação dos volumes de oxigênio (VO2), gás carbônico (VCO2), ventilatório (VE) e mensuração da freqüência cardíaca (FC). A comparação dos parâmetros cardiorrespiratórios (VO2, VE, VCO2 e FC) mensurados com o SNQ e a MASC foi realizada com o teste t de Student para amostras dependentes, enquanto que o teste de correlação de Pearson e a análise gráfica de Bland e Altman foram utilizados para verificar as associações e concordância entre parâmetros. em todos os casos, o nível de significância foi de P < 0,05. A adequação das equações de correção para os valores provenientes do SNQ foi verificada pelos erros sistemáticos (bias), aleatórios (precisão) e acurácia (ac). Não foram observadas diferenças significativas entre os valores de VO2, VCO2 e FC obtidos com a MASC e SNQ. Os valores de VE mensurados com o SNQ foram significativamente superiores aos obtidos com a MASC. No entanto, todos os parâmetros apresentaram elevada concordância e coeficiente de correlação (0,88 a 0,97). Além disso, foram verificados reduzidos valores de bias (VO2 = 0,11L/min; VE = 4,11L/min; VCO2 = 0,54L/min; 8,87bpm), precisão (VO2 = 0,24L/min; VE = 11,02L/ min; VCO2 = 0,18L/min; 7,42bpm) e ac (VO2 = 0,27L/min; VE = 11,76L/min; VCO2 = 0,56L/min; 11,56bpm). Desse modo, pode-se concluir que o SNQ desenvolvido neste estudo possibilita a mensuração válida de parâmetros cardiorrespiratórios em natação.