983 resultados para conflit armé
Resumo:
Objective.- The Patient-Rated Wrist Evaluation is a specific questionnaire for the wrist [1]. It consists of 15 questions with a total score of 100. It was recently translated into French [2]. However, its validity has not been tested in this language. The Disabilities Arm Shoulder and Hand (DASH), with well-established psychometric properties, is considered as the reference questionnaire for the evaluation of upper extremities. The objective of this study is to measure the construct validity of the PRWE-F with the DASH-F in patients with wrist pathology.Patients and methods.- Fifty-one patients (40 m, 11 w, mean age 42 years), 25 fractures of the radius and 26 lesions of the carpus.Questionnaires PRWE-F and DASH-F at entry and at discharge (0 to 100). Calculation of the construct validity of the PRWE-F comparing with the DASH-F with Pearson correlation coefficients (r) at entry and at discharge. Level of significance (alpha) was set at 5%.Results.- Correlation DASH/PRWE at entry: r = 0.799 (95% CI 0.671 to 0.881), P < 0.0001. Correlation DASH/PRWE at discharge: r = 0.847 (95% CI: 0.745 to 0.910), P < 0.0001.Discussion.- The construct validity of the two instruments indicates that they measure the same concept. Our correlation between DASH-F and PRWE-F, going from 0.799 to 0.847, are comparable to those published in different languages (0.71 to 0.84) [3,4]. The questionnaires PRWE-F can thus be used in rehabilitation patients presenting with wrist pathologies; it is comparable to the DASH but described by MacDermid [1] to be more specific. Compared to the DASH it has the advantage of consisting of two dimensions. Its construct validity is excellent. This questionnaire should be evaluated in other populations, and it should be compared with hand questionnaires more specific than the DASH.
Resumo:
BACKGROUND: Pegylated liposomal doxorubicin (PLD) and bevacizumab are active agents in the treatment of metastatic breast cancer (MBC). We carried out a multicenter, single-arm phase II trial to evaluate the toxicity and efficacy of PLD and bevacizumab as first-line treatment in MBC patients. METHODS: Bevacizumab (10 mg/kg) and PLD (20 mg/m(2)) were infused on days 1 and 15 of a 4-week cycle for a maximum of six cycles. Thereafter, bevacizumab monotherapy was continued at the same dose until progression or toxicity. The primary objective was safety and tolerability, and the secondary objective was to evaluate efficacy of the combination. RESULTS: Thirty-nine of 43 patients were assessable for the primary end point. Eighteen of 39 patients (46%, 95% confidence interval 30% to 63%) had a grade 3 toxicity. Sixteen (41%) had grade 3 palmar-plantar erythrodysesthesia, one had grade 3 mucositis, and one severe cardiotoxicity. Secondary end point of overall response rate among 43 assessable patients was 21%. CONCLUSIONS: In this nonrandomized single-arm trial, the combination of bimonthly PLD and bevacizumab in locally recurrent and MBC patients demonstrated higher than anticipated toxicity while exhibiting only modest activity. Based on these results, we would not consider this combination for further investigation in this setting.
Resumo:
The goals of the human genome project did not include sequencing of the heterochromatic regions. We describe here an initial sequence of 1.1 Mb of the short arm of human chromosome 21 (HSA21p), estimated to be 10% of 21p. This region contains extensive euchromatic-like sequence and includes on average one transcript every 100 kb. These transcripts show multiple inter- and intrachromosomal copies, and extensive copy number and sequence variability. The sequencing of the "heterochromatic" regions of the human genome is likely to reveal many additional functional elements and provide important evolutionary information.
Resumo:
In clinical settings, functional evaluation of shoulder movement is primarily based on what the patient thinks he/she is able to do rather than what he/she is actually performing. We proposed a new approach for shoulder assessment based on inertial sensors to monitor arm movement in the daily routine. The detection of movement of the humerus relative to the trunk was first validated in a laboratory setting (sensitivity>95%, specificity>97%). Then, 41 control subjects and 21 patients suffering from a rotator cuff tear were evaluated (before and after surgery) using clinical questionnaires and a one-day measurement of arm movement. The quantity of movement was estimated with the movement frequency and its symmetry index (SIFr). The quality of movement was assessed using the Kolmogorov-Smirnov distance (KS) between the cumulative distribution of the arm velocity for controls and the same distribution for each patient. SIFr presented differences between patients and controls at 3 month follow-up (p<0.05) while KS showed differences also after 6 months (p<0.01). SIFr illustrated a change in dominance due to the disorder whereas KS, which appeared independent of the dominance and occupation, showed a change in movement velocity. Both parameters were correlated to clinical scores (R(2) reaching 0.5). This approach provides clinicians with new objective parameters for evaluating the functional ability of the shoulder in daily conditions, which could be useful for outcome assessment after surgery.
Resumo:
Many types of tumors exhibit characteristic chromosomal losses or gains, as well as local amplifications and deletions. Within any given tumor type, sample specific amplifications and deletions are also observed. Typically, a region that is aberrant in more tumors, or whose copy number change is stronger, would be considered as a more promising candidate to be biologically relevant to cancer. We sought for an intuitive method to define such aberrations and prioritize them. We define V, the "volume" associated with an aberration, as the product of three factors: (a) fraction of patients with the aberration, (b) the aberration's length and (c) its amplitude. Our algorithm compares the values of V derived from the real data to a null distribution obtained by permutations, and yields the statistical significance (p-value) of the measured value of V. We detected genetic locations that were significantly aberrant, and combine them with chromosomal arm status (gain/loss) to create a succinct fingerprint of the tumor genome. This genomic fingerprint is used to visualize the tumors, highlighting events that are co-occurring or mutually exclusive. We apply the method on three different public array CGH datasets of Medulloblastoma and Neuroblastoma, and demonstrate its ability to detect chromosomal regions that were known to be altered in the tested cancer types, as well as to suggest new genomic locations to be tested. We identified a potential new subtype of Medulloblastoma, which is analogous to Neuroblastoma type 1.
Resumo:
Innovative Rail Ltd. of Cedar Rapids, Iowa produced a new rail/highway crossing gate arm that shows promise in two areas: a. Minimizing arm breakage, and b. Added target value to motorists. The new gate was demonstrated to the Chicago and North Western Transportation Company, and that railroad has requested its use at two crossings on an "experimental basis" to determine if its installation provides relief in those areas. On April 18, 1986, the Department observed a test of the material under field conditions with the Transportation Company. The gate received four mid-center strikes at 5 MPH by a company truck while in the lowered position, and showed no damage. In a fifth mid-center strike at 15 MPH, the gate was visibly damaged at the connection to its raising mechanism, but continued to function though at a 5-10 degree drop. Several pictures of the gate and its saddle mechanism are shown in Appendix A of this report. Innovative Rail established distributorships in the United States and Canada, and has since gone out of business.
Resumo:
OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.
Resumo:
When a rubber hand is placed on a table top in a plausible position as if part of a person"s body, and is stroked synchronously with the person"s corresponding hidden real hand, an illusion of ownership over the rubber hand can occur (Botvinick and Cohen 1998). A similar result has been found with respect to a virtual hand portrayed in a virtual environment, a virtual hand illusion (Slater et al. 2008). The conditions under which these illusions occur have been the subject of considerable study. Here we exploited the flexibility of virtual reality to examine four contributory factors: visuo-tactile synchrony while stroking the virtual and the real arms, body continuity, alignment between the real and virtual arms, and the distance between them. We carried out three experiments on a total of 32 participants where these factors were varied. The results show that the subjective illusion of ownership over the virtual arm and the time to evoke this illusion are highly dependent on synchronous visuo-tactile stimulation and on connectivity of the virtual arm with the rest of the virtual body. The alignment between the real and virtual arms and the distance between these were less important. It was found that proprioceptive drift was not a sensitive measure of the illusion, but was only related to the distance between the real and virtual arms.