934 resultados para computed tomographic scan artifact, false positive, facet subluxation
Resumo:
PURPOSE: The aim of the present report is to describe abnormal (18)F-fluorodeoxyglucose (FDG) accumulation patterns in the pleura and lung parenchyma in a group of lung cancer patients in whom lung infarction was present at the time of positron emission tomography (PET). METHODS: Between November 2002 and December 2003, a total of 145 patients (102 males, 43 females; age range 38-85 years) were subjected to whole-body FDG PET for initial staging (n=117) or restaging (n=11) of lung cancer or for evaluation of solitary pulmonary nodules (n=17). Of these patients, 24 displayed abnormal FDG accumulation in the lung parenchyma that was not consistent with the primary lesion under investigation (ipsilateral n=12, contralateral n=9 or bilateral n=3). Without correlative imaging, this additional FDG uptake would have been considered indeterminate in differential diagnosis. RESULTS: Of the 24 patients who were identified as having such lesions, six harboured secondary tumour nodules diagnosed as metastases, while in three the diagnosis of a synchronous second primary lung tumour was established. Additionally, nine patients were identified as having post-stenotic pneumonia and/or atelectasis (n=6) or granulomatous lung disease (n=3). In the remaining six (4% of all patients), a diagnosis of recent pulmonary embolism that topographically matched the additional FDG accumulation (SUV(max) range 1.4-8.6, mean 3.9) was made. Four of these six patients were known to have pulmonary embolism, and hence false positive interpretation was avoided by correlating the PET findings with those of the pre-existing diagnostic work-up. The remaining two patients were harbouring small occult infarctions that mimicked satellite nodules in the lung periphery. Based on histopathological results, the abnormal FDG accumulation in these two patients was attributed to the inflammatory reaction and tissue repair associated with the pathological cascade of pulmonary embolism. CONCLUSION: In patients with pulmonary malignancies, synchronous lung infarction may induce pathological FDG accumulation that can mimic active tumour manifestations. Identifying this potential pitfall may allow avoidance of false positive FDG PET interpretation.
Resumo:
BACKGROUND: The European Guidelines specify a minimum of 5,000 screening cases to be read yearly by radiologists carrying out second reading in non-centralized programs. This professional requirement is difficult to reach and/or to implement in regional programs covering a sparse population with a high number of participating radiology units, so that alternative blind double reading strategies must be devised. OBJECTIVE: To evaluate the effect on breast cancer screening performances of two second reading strategies used in non-centralized, low-volume programs. METHODS: Reading performances in two Swiss regional breast cancer screening programs (cantons of Wallis and Vaud), covering female populations, aged 50-69, of about 31'000 and 72'000 inhabitants were computed and compared. Both programs had similar screening regimens and organizations, but differed with respect to second reading. One setting applied a selective strategy whereby only experienced radiologists performed second reading; the other elicited not to restrict second readers on the basis of their individual screening activity. Analysis included some 140,000 mammograms performed between 1999 and 2005. RESULTS: Overall, screening performances improved with increasing total volume of reading, albeit not in a linear fashion. Regardless of setting, radiologists attained a higher level of screening accuracy when performing second rather than first readings, and incident rather than prevalent screening cases. The effect of a selective, small group of second readers appeared to impact favorably on the false-positive rate and other indicators of screening quality. As the learning curve depends on the number of mammograms read, these distinct strategies may bear different outcome in the long run. Implications and practical issues for low-volume programs are discussed.
Resumo:
RATIONALE AND OBJECTIVES: To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. METHODS AND MATERIALS: A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. RESULTS: Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind.
Resumo:
BACKGROUND AND PURPOSE: To investigate the effect of chronic hyperglycemia on cerebral microvascular remodeling using perfusion computed tomography. METHODS: We retrospectively identified 26 patients from our registry of 2453 patients who underwent a perfusion computed tomographic study and had their hemoglobin A1c (HbA1c) measured. These 26 patients were divided into 2 groups: those with HbA1c>6.5% (n=15) and those with HbA1c≤6.5% (n=11). Perfusion computed tomographic studies were processed using a delay-corrected, deconvolution-based software. Perfusion computed tomographic values were compared between the 2 patient groups, including mean transit time, which relates to the cerebral capillary architecture and length. RESULTS: Mean transit time values in the nonischemic cerebral hemisphere were significantly longer in the patients with HbA1c>6.5% (P=0.033), especially in the white matter (P=0.005). Significant correlation (R=0.469; P=0.016) between mean transit time and HbA1c level was observed. CONCLUSIONS: Our results from a small sample suggest that chronic hyperglycemia may be associated with cerebral microvascular remodeling in humans. Additional prospective studies with larger sample size are required to confirm this observation.
Resumo:
The clinical and radiological data of 52 patients with subarachnoid haemorrhage (SAH) and a negative panangiography were analysed with an average follow-up period of 3.8 years. Of these 52 patients, only one (1.9%) was subsequently found to have an aneurysm. Second angiography proved to be inconclusive in all 24 cases where it was performed. Of the 51 'true' non-aneurysmal SAH, 80% were in a good clinical grade on admission and 12% developed cerebral ischaemia. The mortality rate following SAH was 4%. There was one rebleeding. At follow-up examination, 87% of the patients had made a good recovery and 6% were left disabled due to SAH. Four patients with an aneurysmal pattern of SAH required a permanent shunt. All of the 22 patients with a perimesencephalic SAH were in a good neurological condition upon admission; one of them developed an angiography-induced transient cerebral ischaemia and another one suffered from a fatal rebleeding. None of the 21 survivors was disabled at follow-up examination. The clinical course of patients with SAH of unknown cause, especially those with a perimesencephalic pattern of haemorrhage, is good. Repeated angiography in this latter group is not useful. In the aneurysmal pattern SAH group, repeat angiography is advised only if there is strong computed tomographic (CT) scan suspicion of an aneurysm.
Resumo:
OBJECTIVE: To systematically review and meta-analyze published data about the diagnostic performance of Fluorine-18-Fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (PET/CT) in the assessment of pleural abnormalities in cancer patients. METHODS: A comprehensive literature search of studies published through June 2013 regarding the role of (18)F-FDG-PET and PET/CT in evaluating pleural abnormalities in cancer patients was performed. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odd ratio (DOR) of (18)F-FDG-PET or PET/CT on a per patient-based analysis were calculated. The area under the summary ROC curve (AUC) was calculated to measure the accuracy of these methods in the assessment of pleural abnormalities. Sub-analyses considering (18)F-FDG-PET/CT and patients with lung cancer only were carried out. RESULTS: Eight studies comprising 360 cancer patients (323 with lung cancer) were included. The meta-analysis of these selected studies provided the following results: sensitivity 86% [95% confidence interval (95%CI): 80-91%], specificity 80% [95%CI: 73-85%], LR+ 3.7 [95%CI: 2.8-4.9], LR- 0.18 [95%CI: 0.09-0.34], DOR 27 [95%CI: 13-56]. The AUC was 0.907. No significant improvement considering PET/CT studies only and patients with lung cancer was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be useful diagnostic imaging methods in the assessment of pleural abnormalities in cancer patients, nevertheless possible sources of false-negative and false-positive results should be kept in mind. The literature focusing on the use of (18)F-FDG-PET and PET/CT in this setting remains still limited and prospective studies are needed.
Resumo:
INTRODUCTION: We describe a case of diffuse nesidioblastosis in an adult patient who presented with exclusively fasting symptoms and a focal pancreatic 111In-pentetreotide uptake mimicking an insulinoma. CASE PRESENTATION: A 23-year-old Caucasian man had severe daily fasting hypoglycemia with glucose levels below 2mmol/L. Besides rare neuroglycopenic symptoms (confusion, sleepiness), he was largely asymptomatic. His investigations revealed low venous plasma glucose levels, high insulin and C-peptide levels and a 72-hour fast test that were all highly suggestive for an insulinoma. Abdominal computed tomography and magnetic resonance imaging did not reveal any lesions. The sole imagery that was compatible with an insulinoma was a 111In-somatostatin receptor scintigraphy that showed a faint but definite focal tracer between the head and the body of the pancreas. However, this lesion could not be confirmed by endoscopic ultrasonography of the pancreas. Following duodenopancreatectomy, the histological findings were consistent with diffuse nesidioblastosis. Postoperatively, the patient continued to present with fasting hypoglycemia and was successfully treated with diazoxide. CONCLUSION: In the absence of gastrointestinal surgery, nesidioblastosis is very rare in adults. In addition, nesidioblastosis is usually characterized by post-prandial hypoglycemia, whereas this patient presented with fasting hypoglycemia. This case also illustrates the risk for a false positive result of 111In-pentetreotide scintigraphy in the case of nesidioblastosis. Selective arterial calcium stimulation and venous sampling is the most reliable procedure for the positive diagnosis of insulinoma or nesidioblastosis and should be used to confirm any suspicion based on imaging modalities.
Resumo:
Of 10 patients with neuroblastoma who had both 123I-MIBG scintigraphy and MRI at diagnosis, four presented with bone marrow metastasis that was diagnosed by both imaging modalities and confirmed by bone marrow biopsy and smears. This report focuses on the follow up of the four patients with bone marrow metastasis. MIBG scintigraphy and MRI were concordant in two patients, a case of normalization and a case of relapse in the seventh dorsal vertebra confirmed by surgical biopsy. The last two patients presented a normalized MIBG scan for marrow infiltration after chemotherapy but persistent abnormal MRI signal of several vertebrae, suggesting marrow infiltration, up to 27 mo after the end of chemotherapy in one case. In the second patient, MRI bone marrow aspect returned to normal 4 mo after the end of chemotherapy. Bone marrow biopsy remained negative in these two MIBG-negative patients. These cases suggest that in presence of complete normalization of the MIBG scan after chemotherapy, the persistence of a hypointense signal on bone marrow on T1WI does not necessarily indicate persistence of disease but may be due to delayed normalization. Therefore, attention must be paid to the delay of signal normalization on MRI (which can be as long as more than 2 yr after the end of chemotherapy) in order to avoid false-positive interpretation.
Resumo:
Selectome (http://selectome.unil.ch/) is a database of positive selection, based on a branch-site likelihood test. This model estimates the number of nonsynonymous substitutions (dN) and synonymous substitutions (dS) to evaluate the variation in selective pressure (dN/dS ratio) over branches and over sites. Since the original release of Selectome, we have benchmarked and implemented a thorough quality control procedure on multiple sequence alignments, aiming to provide minimum false-positive results. We have also improved the computational efficiency of the branch-site test implementation, allowing larger data sets and more frequent updates. Release 6 of Selectome includes all gene trees from Ensembl for Primates and Glires, as well as a large set of vertebrate gene trees. A total of 6810 gene trees have some evidence of positive selection. Finally, the web interface has been improved to be more responsive and to facilitate searches and browsing.
Resumo:
The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.
Resumo:
The general strategy to perform anti-doping analyses of urine samples starts with the screening for a wide range of compounds. This step should be fast, generic and able to detect any sample that may contain a prohibited substance while avoiding false negatives and reducing false positive results. The experiments presented in this work were based on ultra-high-pressure liquid chromatography coupled to hybrid quadrupole time-of-flight mass spectrometry. Thanks to the high sensitivity of the method, urine samples could be diluted 2-fold prior to injection. One hundred and three forbidden substances from various classes (such as stimulants, diuretics, narcotics, anti-estrogens) were analysed on a C(18) reversed-phase column in two gradients of 9min (including two 3min equilibration periods) for positive and negative electrospray ionisation and detected in the MS full scan mode. The automatic identification of analytes was based on retention time and mass accuracy, with an automated tool for peak picking. The method was validated according to the International Standard for Laboratories described in the World Anti-Doping Code and was selective enough to comply with the World Anti-Doping Agency recommendations. In addition, the matrix effect on MS response was measured on all investigated analytes spiked in urine samples. The limits of detection ranged from 1 to 500ng/mL, allowing the identification of all tested compounds in urine. When a sample was reported positive during the screening, a fast additional pre-confirmatory step was performed to reduce the number of confirmatory analyses.
Resumo:
Background: Conventional magnetic resonance imaging (MRI) techniques are highly sensitive to detect multiple sclerosis (MS) plaques, enabling a quantitative assessment of inflammatory activity and lesion load. In quantitative analyses of focal lesions, manual or semi-automated segmentations have been widely used to compute the total number of lesions and the total lesion volume. These techniques, however, are both challenging and time-consuming, being also prone to intra-observer and inter-observer variability.Aim: To develop an automated approach to segment brain tissues and MS lesions from brain MRI images. The goal is to reduce the user interaction and to provide an objective tool that eliminates the inter- and intra-observer variability.Methods: Based on the recent methods developed by Souplet et al. and de Boer et al., we propose a novel pipeline which includes the following steps: bias correction, skull stripping, atlas registration, tissue classification, and lesion segmentation. After the initial pre-processing steps, a MRI scan is automatically segmented into 4 classes: white matter (WM), grey matter (GM), cerebrospinal fluid (CSF) and partial volume. An expectation maximisation method which fits a multivariate Gaussian mixture model to T1-w, T2-w and PD-w images is used for this purpose. Based on the obtained tissue masks and using the estimated GM mean and variance, we apply an intensity threshold to the FLAIR image, which provides the lesion segmentation. With the aim of improving this initial result, spatial information coming from the neighbouring tissue labels is used to refine the final lesion segmentation.Results:The experimental evaluation was performed using real data sets of 1.5T and the corresponding ground truth annotations provided by expert radiologists. The following values were obtained: 64% of true positive (TP) fraction, 80% of false positive (FP) fraction, and an average surface distance of 7.89 mm. The results of our approach were quantitatively compared to our implementations of the works of Souplet et al. and de Boer et al., obtaining higher TP and lower FP values.Conclusion: Promising MS lesion segmentation results have been obtained in terms of TP. However, the high number of FP which is still a well-known problem of all the automated MS lesion segmentation approaches has to be improved in order to use them for the standard clinical practice. Our future work will focus on tackling this issue.
Resumo:
BACKGROUND: The cause of acute exacerbation of chronic obstructive pulmonary disease (COPD) is often difficult to determine. Pulmonary embolism may be a trigger of acute dyspnoea in patients with COPD. AIM: To determine the prevalence of pulmonary embolism in patients with acute exacerbation of COPD. METHODS: 123 consecutive patients admitted to the emergency departments of two academic teaching hospitals for acute exacerbation of moderate to very severe COPD were included. Pulmonary embolism was investigated in all patients (whether or not clinically suspected) following a standardised algorithm based on d-dimer testing, lower-limb venous ultrasonography and multidetector helical computed tomography scan. RESULTS: Pulmonary embolism was ruled out by a d-dimer value <500 microg/l in 28 (23%) patients and a by negative chest computed tomography scan in 91 (74%). Computed tomography scan showed pulmonary embolism in four patients (3.3%, 95% confidence interval (CI), 1.2% to 8%), including three lobar and one sub-segmental embolisms. The prevalence of pulmonary embolism was 6.2% (n = 3; 95% CI, 2.3% to 16.9%) in the 48 patients who had a clinical suspicion of pulmonary embolism and 1.3% (n = 1; 95% CI, 0.3% to 7.1%) in those not suspected. In two cases with positive computed tomography scan, the venous ultrasonography also showed a proximal deep-vein thrombosis. No other patient was diagnosed with venous thrombosis. CONCLUSIONS: The prevalence of unsuspected pulmonary embolism is very low in patients admitted in the emergency department for an acute exacerbation of their COPD. These results argue against a systematic examination for pulmonary embolism in this population.
Resumo:
OBJECTIVE: Gadolinium-enhanced pulmonary magnetic resonance angiography (MRA) can be an option in patients with a history of previous adverse reaction to iodinated contrast material and renal insufficiency. Radiation is also avoided. The aim of this study is to prospectively compare the diagnostic value of MRA with that of a diagnostic strategy, taking into account catheter angiography, computed tomography angiography (CTA), and lung scintigraphy [ventilation-perfusion (VQ)]. MATERIAL AND METHODS: Magnetic resonance angiography was done in 48 patients with clinically suspected pulmonary embolism (PE) using fast gradient echo coronal acquisition with gadolinium. Interpretation was done with native coronal images and multiplanar maximum intensity projection reconstructions. Results were compared to catheter angiography (n=15), CTA (n=34), VQ (n=45), as well as 6-12 months clinical follow-ups, according to a sequenced reference tree. RESULTS: The final diagnosis of PE was retained in 11 patients (23%). There were two false negatives and no false positive results with MRA. Computed tomography angiography resulted in no false negatives or false positives. Magnetic resonance angiography had a sensitivity of 82% and a specificity of 100%. CONCLUSION: In our study, pulmonary MRA had a sensitivity of 82% and a specificity of 100% for the diagnosis of PE, with slightly less sensitivity than CTA. In the diagnostic algorithm of PE, pulmonary MRA should be considered as an alternative to CTA when iodine contrast injection or radiation is a significant matter.
Resumo:
OBJECTIVE: Transcranial Doppler (TCD) is widely used to monitor the temporal course of vasospasm after subarachnoid hemorrhage (SAH), but its ability to predict clinical deterioration or infarction from delayed cerebral ischemia (DCI) remains controversial. We sought to determine the prognostic utility of serial TCD examination after SAH. METHODS: We analyzed 1877 TCD examinations in 441 aneurysmal SAH patients within 14 days of onset. The highest mean blood flow velocity (mBFV) value in any vessel before DCI onset was recorded. DCI was defined as clinical deterioration or computed tomographic evidence of infarction caused by vasospasm, with adjudication by consensus of the study team. Logistic regression was used to calculate adjusted odds ratios for DCI risk after controlling for other risk factors. RESULTS: DCI occurred in 21% of patients (n = 92). Multivariate predictors of DCI included modified Fisher computed tomographic score (P = 0.001), poor clinical grade (P = 0.04), and female sex (P = 0.008). After controlling for these variables, all TCD mBFV thresholds between 120 and 180 cm/s added a modest degree of incremental predictive value for DCI at nearly all time points, with maximal sensitivity by SAH day 8. However, the sensitivity of any mBFV more than 120 cm/s for subsequent DCI was only 63%, with a positive predictive value of 22% among patients with Hunt and Hess grades I to III and 36% in patients with Hunt and Hess grades IV and V. Positive predictive value was only slightly higher if mBFV exceeded 180 cm/s. CONCLUSION: Increased TCD flow velocities imply only a mild incremental risk of DCI after SAH, with maximal sensitivity by day 8. Nearly 40% of patients with DCI never attained an mBFV more than 120 cm/s during the course of monitoring. Given the poor overall sensitivity of TCD, improved methods for identifying patients at high risk for DCI after SAH are needed.