792 resultados para communication performance evaluation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The government of the UK has set an ambitious target that all newly built homes be carbon neutral by 2016 and to achieving an overall 80% carbon emission by 2050. Carbon Trust in 2009 published a research revealing that non-domestic buildings accounted for 18% of the emissions in the UK. They argued that to achieve the targets of low carbon emission there is need for better building stock that are better used. The evaluation of the performance of buildings is therefore critical if the understanding of how they are used is to be known. This paper is a brief building performance evaluation of the newly build library at Queens University Belfast carried out during the summer of 2010. It employed the Post-Occupancy Evaluation (POE) methodology to assess its performance. The results reveal that despite the intelligent technologies in the building there was a mismatch between the measured data and the perception of users of its performance. The study suggests the need for further study for reasons of dichotomy of the data. Keywords: building performance evaluation, carbon reduction strategies, passive environmental design techniques, active renewable energy technologies, Northern Ireland

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent theoretical investigations of spatially correlated multitransmit and multireceive (MTMR) links show that not only independently and identically distributed links, but also spatially correlated links can offer linear capacity growth with increasing number of transmit and receive antennas. In this paper, we explore the suitability of the turbo-BLAST architecture in correlated Rayleigh-fading MTMR environments. In particular, for an MTMR system with a large number of receive antennas, a near optimal performance can be achieved by the turbo-BLAST architecture in spatially and temporarily correlated Rayleigh-fading environments. The performance of turbo-BLAST, in terms of both bit-error rate and spectral efficiency, is analyzed empirically in indoors and correlated outdoor environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper the authors propose a new technique for determining a confidence factor applied to the performance prediction of individual luminaires within an overall pattern of luminaires. This work has relevance to any application where it is necessary to determine the performance of a lighting pattern e.g. street lighting, signal lighting etc. In this paper we apply our technique to a transportation application, namely, an airport landing lighting pattern. In the aviation industry it is imperative that the landing lighting pattern at individual airports performs according to standards. We have developed an automated technique which can be used to access the performance of luminaires within this pattern. We extend this work to also derive a confidence factor related to this prediction based on the quality of the data being utilised. ©2010 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study explores the application of a two-stage electrokinetic washing system on remediation of lead (Pb) contaminated soil. The process involved an initial soil washing, followed by an electrokinetic process. The use of electrokinetic process in soil washing not only provided additional driving force for transporting the desorbed Pb away from the soil but also reduced the high usage of wash solution. In this study, the effect of NaNO3, HNO3, citric acid and EDTA as wash solutions on two-stage electrokinetic washing system were evaluated. The results revealed that a two-stage electrokinetic washing process enhanced Pb removal efficiency by 2.52-9.08% and 4.98-20.45% in comparison to a normal electrokinetic process and normal washing process, respectively. Low pH and adequate current were the most important criteria in the removal process as they provided superior desorption and transport properties. The effect of chelating by EDTA was less dominant as it delayed the removal process by forming a transport loop in anode region between Pb ion and complexes. HNO3 was not suitable as wash solution in electrokinetic washing in spite of offering highest removal efficiency as it caused pH fluctuation in the cathode chamber, corroded graphite anode and showed high power consumption. In contrast, citric acid not only yielded high Pb removal efficiency with low power consumption but also maintained a low soil: solution ratio of 1 g: <1 mL, stable pH and electrode integrity. Possible transport mechanisms for Pb under each wash solution are also discussed in this work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Demand response has gain increasing importance in the context of competitive electricity markets environment. The use of demand resources is also advantageous in the context of smart grid operation. In addition to the need of new business models for integrating demand response, adequate methods are necessary for an accurate determination of the consumers’ performance evaluation after the participation in a demand response event. The present paper makes a comparison between some of the existing baseline methods related to the consumers’ performance evaluation, comparing the results obtained with these methods and also with a method proposed by the authors of the paper. A case study demonstrates the application of the referred methods to real consumption data belonging to a consumer connected to a distribution network.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Journal of Cleaner Production, nº 17, p. 36-52

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electric power networks, namely distribution networks, have been suffering several changes during the last years due to changes in the power systems operation, towards the implementation of smart grids. Several approaches to the operation of the resources have been introduced, as the case of demand response, making use of the new capabilities of the smart grids. In the initial levels of the smart grids implementation reduced amounts of data are generated, namely consumption data. The methodology proposed in the present paper makes use of demand response consumers’ performance evaluation methods to determine the expected consumption for a given consumer. Then, potential commercial losses are identified using monthly historic consumption data. Real consumption data is used in the case study to demonstrate the application of the proposed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis examines the performance of Canadian fixed-income mutual funds in the context of an unobservable market factor that affects mutual fund returns. We use various selection and timing models augmented with univariate and multivariate regime-switching structures. These models assume a joint distribution of an unobservable latent variable and fund returns. The fund sample comprises six Canadian value-weighted portfolios with different investing objectives from 1980 to 2011. These are the Canadian fixed-income funds, the Canadian inflation protected fixed-income funds, the Canadian long-term fixed-income funds, the Canadian money market funds, the Canadian short-term fixed-income funds and the high yield fixed-income funds. We find strong evidence that more than one state variable is necessary to explain the dynamics of the returns on Canadian fixed-income funds. For instance, Canadian fixed-income funds clearly show that there are two regimes that can be identified with a turning point during the mid-eighties. This structural break corresponds to an increase in the Canadian bond index from its low values in the early 1980s to its current high values. Other fixed-income funds results show latent state variables that mimic the behaviour of the general economic activity. Generally, we report that Canadian bond fund alphas are negative. In other words, fund managers do not add value through their selection abilities. We find evidence that Canadian fixed-income fund portfolio managers are successful market timers who shift portfolio weights between risky and riskless financial assets according to expected market conditions. Conversely, Canadian inflation protected funds, Canadian long-term fixed-income funds and Canadian money market funds have no market timing ability. We conclude that these managers generally do not have positive performance by actively managing their portfolios. We also report that the Canadian fixed-income fund portfolios perform asymmetrically under different economic regimes. In particular, these portfolio managers demonstrate poorer selection skills during recessions. Finally, we demonstrate that the multivariate regime-switching model is superior to univariate models given the dynamic market conditions and the correlation between fund portfolios.