991 resultados para box-counting method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to compare three different methods for counting white blood cells [WBC] (Natt and Herrick method, estimation with 1,000 and 2,000 erythrocytes) and three methods for counting total thrombocytes [TT] (Wojtaszek method, estimation with 1,000 and 2,000 erythrocytes) in a South American freshwater turtle species, Podocnemis expansa, Schweigger 1812 (Reptilia, Pelomedusidae). Direct WBC counts using the Natt and Herrick method showed limitations, which are discussed here. The WBC and TT counts using 1,000 erythrocytes from blood smears are not recommended for Amazon turtles nor other reptilian species, since wide variation in counts can be observed. Estimation methods for determining WBC and TT based on 2,000 erythrocytes of blood smears were most acceptable because they allow a differentiation between leukocytes and thrombocytes and also had a smaller variation. The methods investigated here for the Amazon turtle, which have been widely used in other reptile species, provided evidence that the most acceptable method is not that of using diluted stains and a hemocytometer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we address the complexity of the analysis of water use in relation to the issue of sustainability. In fact, the flows of water in our planet represent a complex reality which can be studied using many different perceptions and narratives referring to different scales and dimensions of analysis. For this reason, a quantitative analysis of water use has to be based on analytical methods that are semantically open: they must be able to define what we mean with the term “water” when crossing different scales of analysis. We propose here a definition of water as a resource that deal with the many services it provides to humans and ecosystems. WE argue that water can fulfil so many of them since the element has many characteristics that allow for the resource to be labelled with different attributes, depending on the end use –such as drinkable. Since the services for humans and the functions for ecosystems associated with water flows are defined on different scales but still interconnected it is necessary to organize our assessment of water use across different hierarchical levels. In order to do so we define how to approach the study of water use in the Societal Metabolism, by proposing the Water Metabolism, tganized in three levels: societal level, ecosystem level and global level. The possible end uses we distinguish for the society are: personal/physiological use, household use, economic use. Organizing the study of “water use” across all these levels increases the usefulness of the quantitative analysis and the possibilities of finding relevant and comparable results. To achieve this result, we adapted a method developed to deal with multi-level, multi-scale analysis - the Multi-Scale Integrated Analysis of Societal and Ecosystem Metabolism (MuSIASEM) approach - to the analysis of water metabolism. In this paper, we discuss the peculiar analytical identity that “water” shows within multi-scale metabolic studies: water represents a flow-element when considering the metabolism of social systems (at a small scale, when describing the water metabolism inside the society) and a fund-element when considering the metabolism o ecosystems (at a larger scale when describing the water metabolism outside the society). The theoretical analysis is illustrated using two case which characterize the metabolic patterns regarding water use of a productive system in Catalonia and a water management policy in Andarax River Basin in Andalusia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper addresses the issue of double counting of health impacts in the context of cost of illness valuation. Double counting occurs when estimates are jointly used, which rely on valuation techniques that overlap. As a solution, we propose to limit the scope of each of the valuation method to a specific range of impacts. In order to limit the contingentvaluation method to the exclusive valuation of intangible costs, we propose a three steps approach : (1) leave the respondents free to valuate the consequences which matter to them, (2) elicit respondent's motivations, (3) control for the influence motivations have on elicited values. This procedure was applied in a Swiss contingent-valuation. An econometric treatment was applied in order to limit the scope of the estimates of the contingent valuation method to intangibles,therefore the possibility to a combination of methods with the risk of double-counting and underestimating costs being kept to a minimum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A solution of (18)F was standardised with a 4pibeta-4pigamma coincidence counting system in which the beta detector is a one-inch diameter cylindrical UPS89 plastic scintillator, positioned at the bottom of a well-type 5''x5'' NaI(Tl) gamma-ray detector. Almost full detection efficiency-which was varied downwards electronically-was achieved in the beta-channel. Aliquots of this (18)F solution were also measured using 4pigamma NaI(Tl) integral counting and Monte Carlo calculated efficiencies as well as the CIEMAT-NIST method. Secondary measurements of the same solution were also performed with an IG11 ionisation chamber whose equivalent activity is traceable to the Système International de Référence through the contribution IRA-METAS made to it in 2001; IRA's degree of equivalence was found to be close to the key comparison reference value (KCRV). The (18)F activity predicted by this coincidence system agrees closely with the ionisation chamber measurement and is compatible within one standard deviation of the other primary measurements. This work demonstrates that our new coincidence system can standardise short-lived radionuclides used in nuclear medicine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The display tray holds the specimens over a thin cotton layer glued to a thick paper attached to the cd holder tray. Althought only a temporary storing method, it is a good alternative when compared to other layer models. It has the advantages of low cost, protection of specimens, minimal or no damage, as well as good visibility through its cover.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bridge deck deterioration due to corrosive effect of deicers on reinforcing steel is a major problem facing many agencies. Cathodic protection is one method used to prevent reinforcing steel corrosion. The application of a direct current to the embedded reinforcing steel and a sacrificial anode protects the steel from corrosion. This 1992 project involved placing an Elgard Titanium Anode Mesh Cathodic Protection System on a bridge deck. The anode was fastened to the deck after the Class A repair-work and the overlay was placed using the Iowa Low Slump Dense Concrete System. The system was set up initially at 1 mA/sq ft.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When decommissioning a nuclear facility it is important to be able to estimate activity levels of potentially radioactive samples and compare with clearance values defined by regulatory authorities. This paper presents a method of calibrating a clearance box monitor based on practical experimental measurements and Monte Carlo simulations. Adjusting the simulation for experimental data obtained using a simple point source permits the computation of absolute calibration factors for more complex geometries with an accuracy of a bit more than 20%. The uncertainty of the calibration factor can be improved to about 10% when the simulation is used relatively, in direct comparison with a measurement performed in the same geometry but with another nuclide. The simulation can also be used to validate the experimental calibration procedure when the sample is supposed to be homogeneous but the calibration factor is derived from a plate phantom. For more realistic geometries, like a small gravel dumpster, Monte Carlo simulation shows that the calibration factor obtained with a larger homogeneous phantom is correct within about 20%, if sample density is taken as the influencing parameter. Finally, simulation can be used to estimate the effect of a contamination hotspot. The research supporting this paper shows that activity could be largely underestimated in the event of a centrally-located hotspot and overestimated for a peripherally-located hotspot if the sample is assumed to be homogeneously contaminated. This demonstrates the usefulness of being able to complement experimental methods with Monte Carlo simulations in order to estimate calibration factors that cannot be directly measured because of a lack of available material or specific geometries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper presents a method of analyzing Rigid Frames by use of the Conjugate Beam Theory. The development of the method along with an example is given. This method has been used to write a computer program for the analysis of twin box culverts. The culverts may be analyzed under any fill height and any of the standard truck loadings. The wall and slab thickness are increased by the computer program as necessary. The final result is steel requirements both for moment and shear, and the slab and wall thickness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The diagnosis of malignant hematologic diseases has become increasingly complex during the last decade. It is based on the interpretation of results from different laboratory analyses, which range from microscopy to gene expression profiling. Recently, a method for the analysis of RNA phenotypes has been developed, the nCounter technology (Nanostring® Technologies), which allows for simultaneous quantification of hundreds of RNA molecules in biological samples. We evaluated this technique in a Swiss multi-center study on eighty-six samples from acute leukemia patients. METHODS: mRNA and protein profiles were established for normal peripheral blood and bone marrow samples. Signal intensities of the various tested antigens with surface expression were similar to those found in previously performed Affymetrix microarray analyses. Acute leukemia samples were analyzed for a set of twenty-two validated antigens and the Pearson Correlation Coefficient for nCounter and flow cytometry results was calculated. RESULTS: Highly significant values between 0.40 and 0.97 were found for the twenty-two antigens tested. A second correlation analysis performed on a per sample basis resulted in concordant results between flow cytometry and nCounter in 44-100% of the antigens tested (mean = 76%), depending on the number of blasts present in a sample, the homogeneity of the blast population, and the type of leukemia (AML or ALL). CONCLUSIONS: The nCounter technology allows for fast and easy depiction of a mRNA profile from hematologic samples. This technology has the potential to become a valuable tool for the diagnosis of acute leukemias, in addition to multi-color flow cytometry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a polarimetric-based optical encoder for image encryption and verification. A system for generating random polarized vector keys based on a Mach-Zehnder configuration combined with translucent liquid crystal displays in each path of the interferometer is developed. Polarization information of the encrypted signal is retrieved by taking advantage of the information provided by the Stokes parameters. Moreover, photon-counting model is used in the encryption process which provides data sparseness and nonlinear transformation to enhance security. An authorized user with access to the polarization keys and the optical design variables can retrieve and validate the photon-counting plain-text. Optical experimental results demonstrate the feasibility of the encryption method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method is presented for determining the time to first division of individual bacterial cells growing on agar media. Bacteria were inoculated onto agar-coated slides and viewed by phase-contrast microscopy. Digital images of the growing bacteria were captured at intervals and the time to first division estimated by calculating the "box area ratio". This is the area of the smallest rectangle that can be drawn around an object, divided by the area of the object itself. The box area ratios of cells were found to increase suddenly during growth at a time that correlated with cell division as estimated by visual inspection of the digital images. This was caused by a change in the orientation of the two daughter cells that occurred when sufficient flexibility arose at their point of attachment. This method was used successfully to generate lag time distributions for populations of Escherichia coli, Listeria monocytogenes and Pseudomonas aeruginosa, but did not work with the coccoid organism Staphylococcus aureus. This method provides an objective measure of the time to first cell division, whilst automation of the data processing allows a large number of cells to be examined per experiment. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several pixel-based people counting methods have been developed over the years. Among these the product of scale-weighted pixel sums and a linear correlation coefficient is a popular people counting approach. However most approaches have paid little attention to resolving the true background and instead take all foreground pixels into account. With large crowds moving at varying speeds and with the presence of other moving objects such as vehicles this approach is prone to problems. In this paper we present a method which concentrates on determining the true-foreground, i.e. human-image pixels only. To do this we have proposed, implemented and comparatively evaluated a human detection layer to make people counting more robust in the presence of noise and lack of empty background sequences. We show the effect of combining human detection with a pixel-map based algorithm to i) count only human-classified pixels and ii) prevent foreground pixels belonging to humans from being absorbed into the background model. We evaluate the performance of this approach on the PETS 2009 dataset using various configurations of the proposed methods. Our evaluation demonstrates that the basic benchmark method we implemented can achieve an accuracy of up to 87% on sequence ¿S1.L1 13-57 View 001¿ and our proposed approach can achieve up to 82% on sequence ¿S1.L3 14-33 View 001¿ where the crowd stops and the benchmark accuracy falls to 64%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for linearly constrained optimization which modifies and generalizes recent box-constraint optimization algorithms is introduced. The new algorithm is based on a relaxed form of Spectral Projected Gradient iterations. Intercalated with these projected steps, internal iterations restricted to faces of the polytope are performed, which enhance the efficiency of the algorithm. Convergence proofs are given and numerical experiments are included and commented. Software supporting this paper is available through the Tango Project web page: http://www.ime.usp.br/similar to egbirgin/tango/.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Global optimization seeks a minimum or maximum of a multimodal function over a discrete or continuous domain. In this paper, we propose a hybrid heuristic-based on the CGRASP and GENCAN methods-for finding approximate solutions for continuous global optimization problems subject to box constraints. Experimental results illustrate the relative effectiveness of CGRASP-GENCAN on a set of benchmark multimodal test functions.