967 resultados para bioanalytical method validation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work reports the optimization and method validation for sulfonamides (sulfamethazine, sulfaquinoxaline, sulfadimethoxine and sulfathiazole) in shrimp muscle using HPLC-UV. The sulfonamides were extracted with acetonitrile and acetic acid, and the extract cleaned up with a Strata SCX SPE cartridge prior to analysis. The method presented linearity in the range of 20-120 µg kg-1, good linear correlation (r > 0.99), and limits of quantification in the range of 4.7-20.2 µg kg-1. The recovery for shrimp muscles spiked with 50-150 µg kg-1 ranged from 63.2-108.0%. Precision and accuracy analysis showed acceptable relative standard deviation. Commercial shrimps were analyzed and sulfonamides don't were found above of the method limit of quantification.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present work consists of the development and validation of analytical method for evaluation of glycyrrhizic acid, salicylic acid, and caffeine in chitosan-alginate nanoparticles by high performance liquid chromatography. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The methods were applied to nanoparticles suspensions containing the drugs and were able to determine the entrapment efficiency successfully. The best entrapment efficiency was achieved with the glycyrrhizic acid (95.4%).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study investigated the levels of plasticizer endocrine disruptors (diethyl phthalate, dibutyl phthalate, and bisphenol A) in drinking water at Paraíba do Sul River region and release of these compounds from bottled water. An analytical method employing solid phase extraction and GC/MS was optimized and validated. The results showed that the method is selective, linear (r² > 0.99), precise (RSD <12%), accurate (recoveries between 62 and 105%), sensitive and robust. Applying the method, the presence of all studied pollutants in drinking water was observed for the three sampled plasticizers. These plasticizers were not found in mineral bottled water, before or after storage.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study validated a simple and applied method for determining mycotoxins aflatoxin B1, aflatoxin B2, ochratoxin A, zearalenone and deoxynivalenol, in water from the rice production chain. Five solvent combinations for extraction were tested, with quantification performed by TLC/HPTLC and confirmation by LC-MS/MS. Mycotoxins in water from field and rice industries were evaluated. Mycotoxin recovery levels were around 90%. Two samples from rice parboiling waste were contaminated (deoxynivalenol/aflatoxin B1, 110/9 ng mL-1; and deoxynivalenol, 100 ng mL-1). Zearalenone, deoxynivalenol and ochratoxin A (36, 30 and 28%) were carried to soaking water during parboiling.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The need for effective and reliable quality control in products from pharmaceutical industries renders the analyses of their active ingredients and constituents of great importance. This study presents the theoretical basis of ¹H NMR for quantitative analyses and an example of the method validation according to Resolution RE Nº 899 by the Brazilian National Health Surveillance Agency (ANVISA), in which the compound paracetamol was the active ingredient. All evaluated parameters (selectivity, linearity, accuracy, repeatability and robustness) showed satisfactory results. It was concluded that a single NMR measurement provides structural and quantitative information of active components and excipients in the sample.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Phenylpropanoid glycoside verbascoside was isolated and identified from the ethyl acetate fraction of the aerial parts of Buddleja stachyoides Cham. & Schltdl. by 1H-NMR. A method using high-performance liquid chromatography has been developed and validated for determination of verbascoside in alcoholic crude extract of the aerial parts of B. stachyoides. Analysis was performed on a Phenomenex® Gemini-NX C18 analytical column (250 mm × 4.6 mm; 5 µm) using a mobile phase (pump A - aqueous solution containing H2SO4 (0.01 M), H3PO4 (0.4%), and (C2H5)2NH (0.4%); pump B - methanol:aqueous (95:5) solution containing H2SO4 (0.05 M), H3PO4 (2%), and (C2H5)2NH (0.2%); pump C - acetonitrile:aqueous (90:10) solution containing H2SO4 (0.05 M) and H3PO4 (2%)) and a diode array detector at 325 nm. The method was validated in accordance with ANVISA guidelines and may be applied to quality control of herbal medicine with aerial parts of B. stachyoides.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

17α-methyltestosterone (17α-MT) is a hormone used in medicine and aquaculture which can be found in natural waters. It is considered an emerging organic pollutant and its accurate and precise analysis is required. Therefore, this study presents the in-house validation of a new voltammetric methodology for 17α-MT analysis in natural waters. A hanging mercury drop electrode and NaOH 5.0×10-3 mol L-1 solution as the electrolyte were employed in the voltammetric determinations. To confirm the presence of 17α-MT in water samples quantitative analysis was performed by ESI-MS/MS. The methodology exhibited good selectivity, linearity, accuracy (recovery of between 100.4 and 108.8%) and precision (RSDs for repeatability of 2.85% and for intermediate precision of 14.10%, with n = 5, respectively). LOD and LOQ were 3.07 µg L-1 and 10.78 µg L-1, respectively. The methodology was suitable for determination of 17α-MT in natural waters due to low-cost, good performance and no sample pre-treatment required.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We describe a low-cost, high quality device capable of monitoring indirect activity by detecting touch-release events on a conducting surface, i.e., the animal's cage cover. In addition to the detecting sensor itself, the system includes an IBM PC interface for prompt data storage. The hardware/software design, while serving for other purposes, is used to record the circadian activity rhythm pattern of rats with time in an automated computerized fashion using minimal cost computer equipment (IBM PC XT). Once the sensor detects a touch-release action of the rat in the upper portion of the cage, the interface sends a command to the PC which records the time (hours-minutes-seconds) when the activity occurred. As a result, the computer builds up several files (one per detector/sensor) containing a time list of all recorded events. Data can be visualized in terms of actograms, indicating the number of detections per hour, and analyzed by mathematical tools such as Fast Fourier Transform (FFT) or cosinor. In order to demonstrate method validation, an experiment was conducted on 8 Wistar rats under 12/12-h light/dark cycle conditions (lights on at 7:00 a.m.). Results show a biological validation of the method since it detected the presence of circadian activity rhythm patterns in the behavior of the rats

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work describes a method to predict the solubility of essential oils in supercritical carbon dioxide. The method is based on the formulation proposed in 1979 by Asselineau, Bogdanic and Vidal. The Peng-Robinson and Soave-Redlich-Kwong cubic equations of state were used with the van der Waals mixing rules with two interaction parameters. Method validation was accomplished calculating orange essential oil solubility in pressurized carbon dioxide. The solubility of orange essential oil in carbon dioxide calculated at 308.15 K for pressures of 50 to 70 bar varied from 1.7± 0.1 to 3.6± 0.1 mg/g. For same the range of conditions, experimental solubility varied from 1.7± 0.1 to 3.6± 0.1 mg/g. Predicted values were not very sensitive to initial oil composition.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction & Objectifs : Pour assurer l’analgésie postopératoire, l’anesthésiste dispose, en plus des différentes classes de médicaments administrés par voie orale ou intraveineuse, de diverses techniques pour bloquer l’influx nerveux douloureux en administrant les anesthésiques locaux (AL) de manière centrale ou périphérique. La ropivacaïne (ROP), un AL à longue durée d’action, est un médicament de première intention partout dans le monde, en raison de sa grande efficacité et de son faible risque de toxicité. Contrairement à certains pays, la ROP n'est toujours pas indiquée au Canada pour la rachianesthésie (bloc central) en raison d'un manque de données probantes. Jusqu'à présent, les efforts de recherche ont essentiellement porté sur la sécurité ainsi que sur la durée d’action du médicament lorsqu’administré par voie spinale. De plus, les doses optimales de ROP pour l’anesthésie régionale périphérique ne sont pas encore précisément connues. La posologie devrait être adaptée au site d’administration ainsi qu’à l’intensité et la durée du stimulus produit par la chirurgie. Ultimement, cela permettrait aux cliniciens d’identifier le régime optimal en fonction des facteurs démographiques qui pourraient affecter la pharmacocinétique (PK) et la pharmacodynamie (PD) de l’AL (objectif global de ces travaux). Validation de la Méthode Analytique Manuscrit 1 : Une méthode analytique spécifique et sensible permettant de déterminer les concentrations plasmatiques de ROP a d’abord été optimisée et validée. Validation du Biomarqueur Manuscrit 2 : Nous avons ensuite mis au point et évalué la fiabilité d’une méthode quantitative basée sur la mesure du seuil de perception sensorielle (CPT) chez le volontaire sain. Ce test nécessite l’application d’un courant électrique transcutané qui augmente graduellement et qui, selon la fréquence choisie, est capable de stimuler spécifiquement les fibres nerveuses impliquées dans le cheminement de l’influx nerveux douloureux. Les résultats obtenus chez les volontaires sains indiquent que la mesure CPT est fiable, reproductible et permet de suivre l’évolution temporelle du bloc sensitif. Études cliniques Manuscrit 3 : Nous avons ensuite caractérisé, pendant plus de 72 h, l’absorption systémique de la ROP lorsqu’administrée pour un bloc du nerf fémoral chez 19 patients subissant une chirurgie du genou. Le modèle PK populationnel utilisé pour analyser nos résultats comporte une absorption biphasique durant laquelle une fraction de la dose administrée pénètre rapidement (temps d’absorption moyen : 27 min, IC % 19 – 38 min) dans le flux sanguin systémique pendant que l’autre partie, en provenance du site de dépôt, est redistribuée beaucoup plus lentement (demi-vie (T1/2) : 2.6 h, IC % 1.6 – 4.3 h) vers la circulation systémique. Une relation statistiquement significative entre l’âge de nos patients et la redistribution de l’AL suggère que la perméabilité tissulaire est augmentée avec l’âge. Manuscrit 4 : Une analyse PK-PD du comportement sensitif du bloc fémoral (CPT) a été effectuée. Le modèle développé a estimé à 20.2 ± 10.1 mg la quantité de ROP nécessaire au site d’action pour produire 90 % de l’effet maximal (AE90). À 2 X la AE90, le modèle prédit un début d’action de 23.4 ± 12.5 min et une durée de 22.9 ± 5.3 h. Il s’agit de la première étude ayant caractérisé le comportement sensitif d’un bloc nerveux périphérique. Manuscrit 5 : La troisième et dernière étude clinique a été conduite chez les patients qui devaient subir une chirurgie du genou sous rachianesthésie. Tout comme pour le bloc du nerf fémoral, le modèle PK le plus approprié pour nos données suggère que l’absorption systémique de la ROP à partir du liquide céphalo-rachidien est biphasique; c.à.d. une phase initiale (T1/2 : 49 min, IC %: 24 – 77 min) suivie (délai: 18 ± 2 min) d'une phase légèrement plus lente (T1/2 : 66 min, IC %: 36 – 97 min). L’effet maximal a été observé beaucoup plus rapidement, soit aux environs de 12.6 ± 4.9 min, avant de revenir aux valeurs de base 210 ± 55 min suivant l’administration de l’agent. Ces données ont permis d’estimer une AE50 de 7.3 ± 2.3 mg pour l'administration spinale. Conclusion : En somme, ces modèles peuvent être utilisés pour prédire l’évolution temporelle du bloc sensitif de l’anesthésie rachidienne et périphérique (fémorale), et par conséquent, optimiser l’utilisation clinique de la ROP en fonction des besoins des cliniciens, notamment en ce qui a trait à l’âge du patient.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tomato (Lycopersicon esculentum L.) is one of the main constituents of the Mediterranean diet. Its consumption has been proposed to reduce the risk of cardiovascular diseases and certain types of cancer. It is therefore one of the most popular and extensively consumed vegetable crop worldwide. To gain insights on the potential of Lycopersicon esculentum L. as bioactive food, two analytical methodologies were developed to determine the levels of the lipophilic -tocopherol, α-tocopherol, β-carotene, lycopene; and hydrophilic antioxidants ascorbic acid. The quantification of total carotenoids (β-carotene and lycopene) was assessed through a liquid–liquid ultrasound assisted extraction (LL-USAE) in combination with ultraviolet-visible spectroscopy (UV-Vis), according to method of mean, for total carotenoids (λmáx = 450 nm. The ultra-high performance liquid chromatographic using both photodiode array and fluorescence detection (UHPLC-PDA/FLR), allows the identification and quantification of the target lipophilic and hydrophilic antioxidants. This methodology UHPLC-PDA/FLR is fast, simple and revealed a high sensitivity for the compounds under study. The limits of detection (LODs) and quantification (LOQs) obtained were much lower (about 10 times) than the reported in literature. The method LL-USAE/UV-Vis was validated and applied to different tomato foodstuffs. The results reveal a small increase of carotenoids content during maturation, reaching the maximum level when ripe. These results complement those obtained by the ORAC and TBARS assays that show an increase of antioxidant capacity during maturation. The LODs ans LOQs obtained were also about 10 times lower than reported in literature. The carotenoid content was also evaluated by LL-USAE/UV-Vis in different tomatoes varieties. Regional variety present the high carotenoid level, followed by campari and gordal, and at last grape. This methodology was also applied to different processed food samples containing tomatoes derivatives. Highest carotenoids content were obtained in concentrated tomato foodstuffs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The herbal medicine Sanativo® is produced by the Pernambucano Laboratory since 1888 with indications of healing and hemostasis. It is composed of a fluid extract about Piptadenia colubrina, Schinus terebinthifolius, Cereus peruvianus and Physalis angulata. Among the plants in their composition, S. terebinthifolius and P. colubrina have in common phenolic compounds which are assigned most of its pharmacological effects. The tannins, gallic acid and catechin were selected as markers for quality control. The aim of this study was the development and validation of analytical method by HPLC/UV/DAD for the separation and simultaneous quantification of gallic acid (GAC) and catechin (CTQ) in Sanativo®. The chromatographic system was to stationary phase, C-18 RP column, 4,6 x 150 mm (5 mm) under a temperature of 35 ° C, detection at 270 and 210 nm. The mobile phase consisted of 0.05% trifluoroacetic acid and methanol in the proportions 88:12 (v/v), a flow rate of 1 ml/min. The analytical method presented a retention factor of 0.30 and 1.36, tail factor of 1.8 and 1.63 for gallic acid and catechin, respectively, resolution of 18.2, and theoretical plates above 2000. The method validation parameters met the requirements of Resolution n º 899 of May 29, 2003, ANVISA. The correlation coefficient of linear regression analysis for GAC and CTQ from the standard solution was 0.9958 and 0.9973 and when performed from the Sanativo® 0.9973 and 0.9936, the matrix does not interfere in the range 70 to 110 %. The limits of detection and quantification for GAC and CQT were 3.25 and 0.863, and 9.57 and 2.55 mg/mL, respectively. The markers, GAC and CQT, showed repetibility (coefficient of variation of 0.94 % and 2.36 %) and satisfactory recovery (100.02 ± 1.11 % and 101.32 ± 1.36 %). The method has been characterized selective and robust quantification of GAC and CTQ in the Sanativo® and was considered validated