977 resultados para balloon dilatation
Resumo:
Abstract. The electrification of stratiform clouds has is little investigated in comparison with thunderstorms and fair weather atmospheric electricity. Theory indicates that, at the upper and lower horizontal boundaries of layer clouds, charging will arise from vertical flow of cosmogenic ions in the global atmospheric electric circuit. Charge is transferred to droplets and particles, affecting cloud microphysical processes such as collision and droplet activation. Due to the lack of in-situ measurements, the magnitude and distribution of charge in stratiform clouds is not well known. A sensitive, inexpensive, balloon borne charge sensor has been developed to make in-situ measurements of edge charging in stratiform cloud using a standard meteorological radiosonde system. The charge sensor has now been flown through over 20 stratiform clouds and frequently detected charge up to 200 pC m-3 near cloud edges. These results are compared with measurements from the same sensor used to investigate charge in particle layers, such as volcanic ash from the Eyjafjallajökull eruption, and Saharan dust in the Cape Verde Isles. 1.
Resumo:
The ability to undertake repeat measurements of flow-mediated dilatation (FMD) within a short time of a previous measurement would be useful to improve accuracy or to repeat a failed initial procedure. Although standard methods report that a minimum of 10 min is required between measurements, there is no published data to support this. Thirty healthy volunteers had five FMD measurements performed within a 2-h period, separated by various time intervals (5, 15 and 30 min). In 19 volunteers, FMD was also performed as soon as the vessel had returned to its baseline diameter. There was no significant difference between any of the FMD measurements or parameters across the visits indicating that repeat measurements may be taken after a minimum of 5 min or as soon as the vessel has returned to its baseline diameter, which in some subjects may be less than 5 min.
Resumo:
A low cost, disposable instrument for measuring solar radiation during meteorological balloon flights through cloud layers is described. Using a photodiode detector and low thermal drift signal conditioning circuitry, the device showed less than 1% drift for temperatures varied from +20 °C to −35 °C. The angular response to radiation, which declined less rapidly than the cosine of the angle between the incident radiation and normal incidence, is used for cloud detection exploiting the motion of the platform. Oriented upwards, the natural motion imposed by the balloon allows cloud and clear air to be distinguished by the absence of radiation variability within cloud, where the diffuse radiation present is isotropic. The optical method employed by the solar radiation instrument has also been demonstrated to provide higher resolution measurements of cloud boundaries than relative humidity measurements alone.
Resumo:
Background and Purpose— Endothelium-derived hyperpolarizing factor (EDHF) and K+ are vasodilators in the cerebral circulation. Recently, K+ has been suggested to contribute to EDHF-mediated responses in peripheral vessels. The EDHF response to the protease-activated receptor 2 ligand SLIGRL was characterized in cerebral arteries and used to assess whether K+ contributes as an EDHF. Methods— Rat middle cerebral arteries were mounted in either a wire or pressure myograph. Concentration-response curves to SLIGRL and K+ were constructed in the presence and absence of a variety of blocking agents. In some experiments, changes in tension and smooth muscle cell membrane potential were recorded simultaneously. Results— SLIGRL (0.02 to 20 μmol/L) stimulated concentration and endothelium-dependent relaxation. In the presence of NG-nitro-L-arginine methyl ester, relaxation to SLIGRL was associated with hyperpolarization and sensitivity to a specific inhibitor of IKCa, 1-[(2-chlorophenyl)diphenylmethyl]-1H-pyrazole (1μmol/L), reflecting activation of EDHF. Combined inhibition of KIR with Ba2+ (30μmol/L) and Na+/K+-ATPase with ouabain (1 μmol/L) markedly attenuated the relaxation to EDHF. Raising extracellular [K+] to 15 mmol/L also stimulated smooth muscle relaxation and hyperpolarization, which was also attenuated by combined application of Ba2+ and ouabain. Conclusions— SLIGRL evokes EDHF-mediated relaxation in the rat middle cerebral artery, underpinned by hyperpolarization of the smooth muscle. The profile of blockade of EDHF-mediated hyperpolarization and relaxation supports a pivotal role for IKCa channels. Furthermore, similar inhibition of responses to EDHF and exogenous K+ with Ba2+ and ouabain suggests that K+ may contribute as an EDHF in the middle cerebral artery.
Resumo:
In this paper we report on a study conducted using the Middle Atmospheric Nitrogen TRend Assessment (MANTRA) balloon measurements of stratospheric constituents and temperature and the Canadian Middle Atmosphere Model (CMAM). Three different kinds of data are used to assess the inter-consistency of the combined dataset: single profiles of long-lived species from MANTRA 1998, sparse climatologies from the ozonesonde measurements during the four MANTRA campaigns and from HALOE satellite measurements, and the CMAM climatology. In doing so, we evaluate the ability of the model to reproduce the measured fields and to thereby test our ability to describe mid-latitude summertime stratospheric processes. The MANTRA campaigns were conducted at Vanscoy, Saskatchewan, Canada (52◦ N, 107◦ W)in late August and early September of 1998, 2000, 2002 and 2004. During late summer at mid-latitudes, the stratosphere is close to photochemical control, providing an ideal scenario for the study reported here. From this analysis we find that: (1) reducing the value for the vertical diffusion coefficient in CMAM to a more physically reasonable value results in the model better reproducing the measured profiles of long-lived species; (2) the existence of compact correlations among the constituents, as expected from independent measurements in the literature and from models, confirms the self-consistency of the MANTRA measurements; and (3) the 1998 measurements show structures in the chemical species profiles that can be associated with transport, adding to the growing evidence that the summertime stratosphere can be much more disturbed than anticipated. The mechanisms responsible for such disturbances need to be understood in order to assess the representativeness of the measurements and to isolate longterm trends.
Resumo:
Charged aerosol particles and water droplets are abundant throughout the lower atmosphere, and may influence interactions between small cloud droplets. This note describes a small, disposable sensor for the measurement of charge in non-thunderstorm cloud, which is an improvement of an earlier sensor [K. A. Nicoll and R. G. Harrison, Rev. Sci. Instrum. 80, 014501 (2009)]. The sensor utilizes a self-calibrating current measurement method. It is designed for use on a free balloon platform alongside a standard meteorological radiosonde, measuring currents from 2 fA to 15 pA and is stable to within 5 fA over a temperature range of 5 °C to −60 °C. During a balloon flight with the charge sensor through a stratocumulus cloud, charge layers up to 40 pC m−3 were detected on the cloud edges.
Resumo:
A disposable backscatter instrument is described for optical detection of cloud in the atmosphere from a balloon-carried platform. It uses an ultra-bright light emitting diode (LED) illumination source with a photodiode detector. Scattering of the LED light by cloud droplets generates a small optical signal which is separated from background light fluctuations using a lock-in technique. The signal to noise obtained permits cloud detection using the scattered LED light, even in daytime. The response is interpreted in terms of the equivalent visual range within the cloud. The device is lightweight (150 g) and low power (∼30 mA), for use alongside a conventional meteorological radiosonde.
Resumo:
A weather balloon and its suspended instrument package behave like a pendulum with a moving pivot. This dynamical system is exploited here for the detection of atmospheric turbulence. By adding an accelerometer to the instrument package, the size of the swings induced by atmospheric turbulence can be measured. In test flights, strong turbulence has induced accelerations greater than 5g, where g = 9.81 m s−2. Calibration of the accelerometer data with a vertically orientated lidar has allowed eddy dissipation rate values of between 10−3 and 10−2 m2 s−3 to be derived from the accelerometer data. The novel use of a whole weather balloon and its adapted instrument package can be used as a new instrument to make standardized in situ measurements of turbulence.
Resumo:
Solar eclipses provide a rapidly changing solar radiation environment. These changes can be studied using simple photodiode sensors, if the radiation reaching the sensors is unaffected by cloud.Transporting the sensors aloft using standard meteorological instrument packages modified to carry extra sensors, provides one promising but hitherto unexploited possibility for making solar eclipse radiation measurements. For the 20th March 2015 solar eclipse, a coordinated campaign of balloon-carried solar radiation measurements was undertaken from Reading (51.44N, 0.94W), Lerwick (60.15N, 1.13W) and Reykjavik (64.13N, 21.90W), straddling the path of the eclipse.The balloons reached sufficient altitude at the eclipse time for eclipse-induced variations in solar radiation and solar limb darkening to be measured above cloud. Because the sensor platforms were free to swing, techniques have been evaluated to correct the measurements for their changing orientation. In the swing-averaged technique, the mean value across a set of swings was used to approximate the radiation falling on a horizontal surface; in the swing-maximum technique, the direct beam was estimated by assuming the sensing surface becomes normal to the solar beam direction at a maximum swing. Both approaches, essentially independent,give values that agree with theoretical expectations for the eclipse-induced radiation changes.
Resumo:
The present article relates the occurrence of Proventricular Dilatation Disease (PDD) in a 20 years old blue-fronted amazon parrot (Amazona aestiva). The bird was raised in captivity and was examined at the Ornitopathology Laboratory of São Paulo State University's Veterinarian Hospital, São Paulo State, Brazil. The parrot clinically presented regurgitation, tremors and dyspnea. This is the first case of PDD followed by megaesophagus in a blue-fronted amazon parrot (A. aestiva). This pathological case was not described in birds at all.
Resumo:
Trinta e duas papilas mamárias de vacas da raça Holandesa, em período seco, foram submetidas a telotomia lateral que produziu defeito linear na mucosa da parte papilar do seio lactífero (PPSL). Houve excisão de um retângulo de mucosa de tamanho padronizado que provocou um defeito retangular na mucosa do PPSL, oposto à telotomia. Todas as telotomias foram suturadas e, aleatoriamente, em 16 delas foram introduzidas sondas de Foley de 2,7mm de diâmetro, formando o grupo de papilas com dilatador. A distensão dos balonetes das sondas de Foley provocou a dilatação da PPSL o que forçou a manutenção das sondas, por sete dias, na papila mamária. As 16 papilas restantes formaram o grupo de papilas sem dilatador. Foram realizadas videoteloscopias antes (dia 0) e após as telotomias (dia 8, após a retirada das sondas de Foley e dia 15). As avaliações morfológica e histológica do processo de cicatrização dos defeitos lineares e retangulares evidenciaram que o uso de dilatador na PPSL auxiliou na orientação cicatricial, mantendo a patência do seio lactífero em um maior número de papilas, quando os dois grupos foram comparados. A dilatação da PPSL interferiu na cicatrização das telotomias, e provocou maior número de alterações no epitélio de revestimento do seio lactífero.
Resumo:
INTRODUÇÃO: O excesso de peso na população aumentou de forma significante nas últimas décadas e as bebidas gasosas tornaram-se um fator ambiental importante no comportamento alimentar das pessoas, sendo os EUA, México e Brasil, nesta ordem, os três maiores paises produtores e consumidores de refrigerantes. OBJETIVO: Investigar os efeitos da dilatação gástrica em ratos submetidos a ingestão de água gaseificada, veículo uniforme para todos os refrigerantes, sobre parâmetros metabólicos da função hepática. MÉTODOS: Foram constituídos dois grupos de 15 ratos acompanhados por 15 semanas. Ao Grupo-I, foram oferecidos 200 g/dia de ração ad libitum e 100 ml de água não gaseificada em 3 períodos diários, ao Grupo-II, foram oferecidos 200 g/dia de ração ad libitum e 100 ml de água gaseificada em 3 períodos diários; em cada grupo,foram calculados a média (x) e o desvio padrão (s); para todos os atributos estudados foi utilizado o método estatístico de teste t pareado, comparando-se GI com GII, testando-se o efeito dos tipos de água. RESULTADOS: Os resultados identificaram que os animais que foram submetidos ao tratamento com água gaseificada (Grupo-II), apresentaram um aumento de transaminase glutâmica pirúvica (TGP) e fosfatase alcalina p<0,01), tendência de aumento da transaminase glutâmica oxalacética (TGO) (0,10>p>0,05) e aumento da área gástrica com alterações morfológicas macroscópicas como o desaparecimento do pregueamento mucoso característico. CONCLUSÃO: A água gaseificada favoreceu o aumento da área gástrica com conseqüente desaparecimento macroscópico do pregueamento mucoso do órgão, que ocasionou alterações metabólicas da função hepática.
Resumo:
Toxic megacolon occurs in colitis of differing aetiology. This report describes 15 patients with chagasic megacolon with this complication. The clinical signs and symptoms in all patients were pain and progressive abdominal distension accompanied by fever, severe toxaemia and shock. Seven patients developed this clinical pattern after manual removal of faeces. The remaining patients had pain and abdominal distension followed by signs of severe toxaemia when first examined. Nine patients underwent total colectomy with ileostomy (one death), four partial colectomy (all died) and two received medical treatment (both died). At autopsy, three of the four patients undergoing partial colectomy had residual colitis and enteritis. The surgical procedure of choice for this complication of chagasic megacolon is total colectomy.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Six patients with advanced Chagas' megaesophagus with poor condition for surgical indication due to severe malnutrition and concomitant diseases were submitted to pneumatic dilatation with the aid of the endoscope. The method consists in leading the tip of the pneumatic dilatator into the cardia with the tip of the endoscope. Insufflation of the balloon must be slow and progressive with visualization of the mucosa of the cardia after insufflating of 2 pounds of air pressure. An excellent symptomatic relief was seen in the five-year follow-up but without improvement in the degree of the esophageal dilatation.