952 resultados para axial gauges


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correlators of singlet and octet axial currents, as well as anomaly and pseudoscalar densities have been studied using QCD sum rules. Several of these sum rules are used to determine the couplings f(eta)(8),f(eta)(0), f(eta)('8) and f(eta)('0). We find mutually consistent values which are also in agreement with phenomenological values obtained from data on various decay and production rates. While most of the sum rules studied by us are independent of the contributions of direct instantons and screening correction, the singlet-singlet current correlator and the anomaly-anomaly correlator improve by their inclusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the important developments in rotary wing aeroelasticity in the recent past has been the growing awareness and acceptance of the fact that the problem is inherently non-linear and that correct treatment of aeroelastic problems requires the development of a consistent mathematical model [l]. This has led to a number of studies devoted to the derivation of a consistent set of “second order” non-linear equations, for example, those of Hodges and Dowel1 [2], of Rosen and Friedmann [3], and of Kvaternik, White and Kaza [4], each of which differs from the others on the question of the inclusion of certain terms in the equations of motion. The final form of the equations depends first upon the ordering scheme used for characterizing the displacements and upon the consistency with which this is applied in omitting terms of lower order. The ideal way of achieving this would be to derive the equations of motion with all the terms first included regardless of their relative orders of magnitude and then to apply the ordering scheme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aluminium rings of varying Image Image diameter ratios machined from extruded solid bars, were subjected to static axial compression. Etched diametral planes of deformed cylinders revealed the existence of shear bands, the configuration of which were found to change with initial specimen geometry and deformation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is well known that the use of a series of resistors, connected between the equipotential rings of a Van de Graaff generator, improves the axial voltage grading of the generator. The work reported in this paper shows how the resistor chain also improves the radial voltage gradient. The electrolytic field mapping technique was adopted in the present work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic venous disease (CVD), including uncomplicated varicose veins and chronic venous insufficiency, is one of the most common medical conditions in the Western world. The central feature of CVD is venous reflux, which may be primary, congenital, or result from an antecedent event, usually an acute deep venous thrombosis (DVT). When the history of DVT is clear, the clinical manifestations of secondary CVD are commonly referred to as the post-thrombotic syndrome. Regardless of the underlying etiology, the final pathway leading to symptoms is ambulatory venous hypertension. The spectrum of symptoms and signs of CVD ranges from minor cosmetic problems to venous ulceration, which results in considerable morbidity and increased medical costs. Aims of this study were to evaluate the outcome of superficial venous surgery performed with or without preoperative duplex evaluation and venous marking with hand-held doppler, to assess short-term outcome of ultrasound-guided foam sclerotherapy in patients with axial superficial venous incompetence, as well as to compare reflux patterns after catheter-directed and systemic thrombolysis of deep ileofemoral venous thrombosis, and to evaluate the long-term outcome of deep venous reconstructions for severe chronic venous insufficiency. The study consists of five separate retrospective projects and includes 315 patients. Of this, 133 patients had undergone superficial venous surgery 2 to 5 years earlier according to preoperative duplex examination and venous marking, or according to clinical evaluation alone, or to a written plan without venous marking. A total of 112 patients had undergone ultrasound-guided foam sclerotherapy 5.5 to 16.5 months before. In addition, 32 patients had received either catheter-directed or systemic thrombolysis for DVT 2 to 3 years earlier, and 38 patients had undergone deep venous reconstructions 2 to 7 years earlier. In the present studies, some venous reflux was present postoperatively irrespective of the method of evaluation or ablation of the reflux. It seemed, however, that preoperative examination with duplex ultrasound and marking of reflux sites before the operation by the operating surgeon improves the outcome of superficial venous surgery. Ultrasound-guided foam sclerotherapy is effective in elimination of venous reflux in selected cases in short-term follow-up. Catheter-directed thrombolysis for deep iliofemoral venous thrombosis reduces later reflux and most probably the development of post-thrombotic syndrome as well. The outcome of deep venous reconstructions, especially for post-thrombotic deep venous incompetence, is poor. Thus, prevention of valvular damage by active treatment of deep venous thrombosis is important.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bhatnagar and Rathna (Quar. Journ. Mech. Appl. Maths., 1963,16, 329) investigated the flows of Newtonian, Reiner-Rivlin and Rivlin-Ericksen fluids between two rotating coaxial cones. In case of the last two types of fluids, they predicted the breaking of secondary flow field in any meridian plane. We find that such breaking is avoided by the application of a sufficiently strong azimuthal magnetic field arising from a line current along the axis of the cones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present note we have studied the harmonic and anharmonic oscillations of cylindrical plasma using Lagrangian formalism. In order to study the harmonic oscillations, the equations are linearized and the resulting equation for the displacement has been numerically solved. For situations present in thermonuclear reactors, the presence of axial magnetic field is found necessary to make the periods of oscillation to become comparable with the time required for the thermonuclear reactions to set in. A detailed analysis of the anharmonic oscillations reveals that the significant interaction is between the first and the second mode. The fundamental period of anharmonic oscillation is more than the corresponding period of harmonic oscillations by 9·2%. Graphs have been drawn for the amplitudes of relative variations in density and magnetic field and of the time-varying part of anharmonic oscillation.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review gives a brief description of the historical development followed by the origin and the principle of operation of strain gauges. The features of an ideal strain gauge for measurement purposes and the general classes of strain gauges are given. The remaning part is devoted to an important development in strain gauge technology, namely thin film strain gauges. After highlighting the advantages of thin film strain gauges, a review of current data is given. Detailed description of metallic thin film strain gauges is provided and avaliable information on alloy semiconductor and cermet films for their possible use as strain gauge elements has also been included. The importance of ion implantation in tailoring the properties of strain gauges is highlighted. 33 ref.--AA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results of photoelastic investigations conducted on cylindrical tubes (made of Araldite material) containing cracks oriented at 0°, 30°, 45°, 60° and 90° to the axis of the tube and subjected to axial and torsional loads are reported. The stress-intensity factors (SIFs) were determined by analysing the crack-tip stress fields. Smith and Smith's method [Engng Fracture Mech.4, 357–366 (1972)] and a new method developed by the authors by modifying Rakesh et al.'s method [Proc. 26th Congress of ISTAM, India (1981)] were employed to evaluate the mixed-mode SIFs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The isoscalar axial-vector renormalization constant is reevaluated using the QCD sum-rule method. It is found to be substantially different from the anomaly-free octet axial-vector u¯γμγ5+d¯γμγ5-2s¯γμγ5 coupling. Combining this determination with the known values of the isovector coupling GA and the F/D ratio for the octet current, we find the integral of the polarized proton structure function to be Gp=Fgp1(x)dx=0.135, in agreement with recent measurement by the European Muon Collaboration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mandelstam�s argument that PCAC follows from assigning Lorentz quantum numberM=1 to the massless pion is examined in the context of multiparticle dual resonance model. We construct a factorisable dual model for pions which is formulated operatorially on the harmonic oscillator Fock space along the lines of Neveu-Schwarz model. The model has bothm ? andm ? as arbitrary parameters unconstrained by the duality requirement. Adler self-consistency condition is satisfied if and only if the conditionm?2?m?2=1/2 is imposed, in which case the model reduces to the chiral dual pion model of Neveu and Thorn, and Schwarz. The Lorentz quantum number of the pion in the dual model is shown to beM=0.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A conformationally locked fluoropentol undergoes an interesting transformation to (trans,anti,trans,anti,trans)-perhydro-2,3,4a,6,7,8a-naphthalenehexol essentially under conditions of base-induced transesterification. The proposed rationale for the observed metamorphosis involves a nucleophilic displacement of fluoride, and subsequent stereo- and regioselective anti-Furst-Plattner-type ring-opening of the epoxide thus formed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of a pressure transducer with meandering-path thin film strain gauges has been studied. Details of the procedure followed to prepare the thin film strain gauge system on the pressure transducer diaphragm are given. The effect of post-deposition heat treatment on the resistance of the sensing films of the strain gauges and the insulating base layers are discussed. The output of the pressure transducer was studied with various input pressures and excitation voltages. It was found that up to a maximum of 10 V bridge excitation the output was stable and repetitive. The maximum non-linearity and hysteresis observed are ±0.15%, ±0.16% and ±0.14% FSO (full-scale output) for 5, 7.5 and 10 V excitation respectively. Information on the output behaviour of the pressure transducer with temperature is also included.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tripod ligand possessing two pyridine moieties and a phenolato group as pendants forms a mononuclear complex with an axial copper(II)–phenolate co-ordination in a square-pyramidal environment.