986 resultados para adiabatic calorimetry
Resumo:
Combined with the national standard biomonitoring method (polyurethane foam units method), calorimetry was applied to study the metabolic activities of PFU microbial communities in fresh water to determine the effects of anthropotgenic stresses on the activity of the microbial community. Comparisons were made at four sampling stations with different eutrophic status in Lake Donghu. Water quality variables, species number of protozoa, abundances of microorganisms, biomass, heterotrophy indexes and diversity indexes are reported. The heat rate-time curves of the native and concentrated PFU microbial communities were determined at 28 degrees C. Growth rate, measured maximum power output and total heat were calculated from the heat rate-time curves. The values of metabolic variables are higher at the more eutrophic stations, which suggests that organic pollution increases the activity of PFU microbial communities. The metabolic variables are in good agreement with chemical and biotic variables. And calorimetry will be useful for biomonitoring of the PFU microbial community. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
Thermal effects will make chip temperature change with bias current of semiconductor lasers, which results in inaccurate intrinsic response by the conventional subtraction method. In this article, an extended subtraction method of scattering parameters for characterizing adiabatic responses of laser diode is proposed. The pulsed injection operation is used to determine the chip temperature of packaged semiconductor laser, and an optimal injection condition is obtained by investigating the dependence of the lasing wavelength on the width and period of the injection pulse in a relatively wide temperature range. In this case, the scattering parameters of laser diode are measured on adiabatic condition and the adiabatic intrinsic responses of packaged laser diode are first extracted. It is found that the adiabatic intrinsic responses are evidently superior to those without thermal consideration. The analysis results indicate that inclusion of thermal. effects is necessary to acquire accurate intrinsic responses of semiconductor lasers. (C) 2008 Wiley Periodicals, Inc.
Resumo:
Based on the analytical solution to the time-dependent Schrodinger equations, we evaluate the holonomic quantum computation beyond the adiabatic limit. Besides providing rigorous confirmation of the geometrical prediction of holonomies, the present dynamical resolution offers also a practical means to study the nonadiabaticity induced effects for the universal qubit operations.
Resumo:
An extended subtraction method of scattering parameters for characterizing laser diode is introduced in this paper. The intrinsic small-signal response can be directly extracted from the measured transmission coefficients of laser diode by the method. However the chip temperature may change with the injection bias current due to thermal effects, which causes inaccurate intrinsic response by our method. Therefore, how to determine the chip temperature and keep the laser chip adiabatic is very critical when extracting the intrinsic response. To tackle these problems, the dependence of the lasing wavelength of the laser diode on the chip temperature is investigated, and an applicable measurement setup which keeps the chip temperature stable is presented. The scattering parameters of laser diode are measured on diabatic and adiabatic conditions, and the extracted intrinsic responses for both conditions are compared. It is found that the adiabatic intrinsic responses are evidently superior to those without thermal consideration. The analysis indicates that inclusion of thermal effects is necessary to acquire accurate intrinsic response.
Resumo:
The heat capacities of berberine sulphate [(C20H18NO4)(2)SO4.3H(2)O] were measured from 80 to 390 K by means of an automated adiabatic calorimeter. Smoothed heat capacities,{H-T-H-298.15} and {S-T-S-298.15} were calculated. The loss of crystalline water started at about 339.3+/-0.2 K, and its peak temperature was 365.8+/-0.6 K. The peak temperature of decomposition for berberine sulphate was at about 391.4+/-0.4 K by DSC curve. TG-DTG analysis of this material was carried out in temperature range from 310 to 970 K. TG and DSC curves show that there is no melting in the whole heating process.
Resumo:
The melting behavior of poly(methyl methacrylate)-grafted nascent polyethylene reactor powder by plasma irradiation was studied by differential scanning calorimetry (DSC). The grafting yield ranged hom 11 to 190%. Grafting was found to lower both melting point and heat of fusion during the first run of DSC determination. The heat of fusion was used to calculate the apparent grafting yield of the samples. There was little strain induced by plasma-irradiated grafting on the surface of the polyethylene crystals. A method to determine the covalent grafting yield in the graft copolymer systems was developed. (C) 1995 John Wiley & Sons, Inc.
Resumo:
The aim of this work is to describe the most recent achievements in the field of the physical chemistry of mixing. The systems studied have been classified according to the amount of thermic effect due to the blending and its interpretation. When polystyrene (PS) and poly(alpha-methylstyrene) (P alpha MS) are blended, the interaction is weak and Delta(mix)H is close to zero. The presence of polar atoms and/or groups increases the stability of the blend and, therefore, Delta(mix)H becomes more negative. Poly(ethylene oxide) (PEO), poly(methyl acrylate) (PMA), poly(methyl methacrylate) (PMMA) and poly(vinylacetate) (PVAc), when mixed to form binary systems, show large differences from their properties when pure. If hydrogen bonding takes place, the interactions are readily detected and a large effect is calorimetrically determined. Cellulose diacetate (CDA) and poly(vinylpyrrolidone) (PVP) have been studied as an example of a strongly interacting system.
Resumo:
The stability constants and thermodynamic functions for complexes of rare earth with L-phenylalanine have been determined by potentiometry and calorimetry at 25-degrees-C and ionic strength of 0.15mol.dm-3(NaCl). Stability of the complexes shows the "Tetrad effect". The entropy change makes a predominant contribution to the stability of these complexes. The ligand is coordinated to rare earth ions through its -CO2- and -NH2 group, and dehydration of ions plays an important role in coordination reaction.
Resumo:
The crystallinity of two series of uniform oligo(oxyethylene) mono-n-alkyl ethers has been investigated: alpha-alkyl,omega-hydroxyoligo(oxyethylene)s, H(CH2)n(OCH2CH2)mOH, and alpha-alkyl,omega-methoxyoligo(oxyethylene)s, H(CH2)n(OCH2CH2)mOCH3. The hydroxy-ended oligomers formed bilayer crystals, and the methoxy-ended oligomers formed monolayer crystals. The helical oxyethylene blocks were oriented normal to the layer-crystal end-group plane, whilst the trans-planar alkyl blocks were generally tilted at an angle delta = 60-degrees. The melting temperature and enthalpy of fusion were higher for hydroxy-ended oligomers than for corresponding methoxy-ended oligomers.
Resumo:
Fe-B ultrafine amorphous alloy particles (UFAAP) were prepared by chemical reduction of Fe3+ with NaBHO4 and confirmed to be ultrafine amorphous particles by transmission electron microscopy and X-ray diffraction. The specific heat of the sample was measured by a high precision adiabatic calorimeter, and a differential scanning calorimeter was used for thermal stability analysis. A topological structure of Fe-B atoms is proposed to explain two crystallization peaks and a melting peak observed at T=600, 868 and 1645 K, respectively.
Resumo:
The heat capacities of Wood alloy have been measured with an automatic adiabatic calorimeter over the temperature range of 80 similar to 360 K. The thermodynamic data of solid-liquid phase transition have been obtained from the heat capacity measurements. The melting temperature, enthalpy and entropy of fusion of the substance are 345.662 K, 18.47 J.g(-1) and 0.05343 J.g(-1).K-1, respectively. The necessary thermal data are provided for the low temperature thermodynamic study of the alloy.