999 resultados para Xe lamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

DC-LAMP, a member of the lysosomal-associated membrane protein (LAMP) family, is specifically expressed by human dendritic cells (DC) upon activation and therefore serves as marker of human DC maturation. DC-LAMP is detected first in activated human DC within MHC class II molecules-containing compartments just before the translocation of MHC class II-peptide complexes to the cell surface, suggesting a possible involvement in this process. The present study describes the cloning and characterization of mouse DC-LAMP, whose predicted protein sequence is over 50% identical to the human counterpart. The mouse DC-LAMP gene spans over 25 kb and shares syntenic chromosomal localization (16B2-B4 and 3q26) and conserved organization with the human DC-LAMP gene. Analysis of mouse DC-LAMP mRNA and protein revealed the expression in lung peripheral cells, but also its unexpected absence from mouse lymphoid organs and from mouse DC activated either in vitro or in vivo. In conclusion, mouse DC-LAMP is not a marker of mature mouse DC and this observation raises new questions regarding the role of human DC-LAMP in human DC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A full-electron coupled-state treatment of positronium (Ps)- inert gas scattering is developed within the context of the frozen target approximation. Calculations are performed for Ps(Is) scattering by Ne and Ar in the impact energy range 0-40 eV using coupled pseudostate expansions consisting of nine and 22 Ps states. The purpose of the pseudostates is primarily to represent ionization of the Ps which is found to be a major process at the higher energies. First Born estimates of target excitation are used to complement the frozen target results. The available experimental data are discussed in detail. It is pointed out that the very low energy measurements (less than or equal to2 eV) correspond to the momentum transfer cross section sigma(mom) and not to the elastic cross section sigma(el). Calculation shows that sigma(mom), and sigma(el) diverge very rapidly with increasing energy and consequently comparisons of the low-energy data with ITel can be very misleading. Agreement between the calculations and the low-energy measurements of anion as well;as higher energy (greater than or equal to15 eV) beam measurements of the total cross section, is less than satisfactory. Results for Ps(1s) scattering by Kr and Xe in the static-exchange approximation are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The least-mean-fourth (LMF) algorithm is known for its fast convergence and lower steady state error, especially in sub-Gaussian noise environments. Recent work on normalised versions of the LMF algorithm has further enhanced its stability and performance in both Gaussian and sub-Gaussian noise environments. For example, the recently developed normalised LMF (XE-NLMF) algorithm is normalised by the mixed signal and error powers, and weighted by a fixed mixed-power parameter. Unfortunately, this algorithm depends on the selection of this mixing parameter. In this work, a time-varying mixed-power parameter technique is introduced to overcome this dependency. A convergence analysis, transient analysis, and steady-state behaviour of the proposed algorithm are derived and verified through simulations. An enhancement in performance is obtained through the use of this technique in two different scenarios. Moreover, the tracking analysis of the proposed algorithm is carried out in the presence of two sources of nonstationarities: (1) carrier frequency offset between transmitter and receiver and (2) random variations in the environment. Close agreement between analysis and simulation results is obtained. The results show that, unlike in the stationary case, the steady-state excess mean-square error is not a monotonically increasing function of the step size. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loop-mediated isothermal amplification (LAMP) is an innovative technique that allows the rapid detection of target nucleic acid sequences under isothermal conditions without the need for complex instrumentation. The development, optimization, and clinical validation of a LAMP assay targeting the ctrA gene for the rapid detection of capsular Neisseria meningitidis were described. Highly specific detection of capsular N. meningitidis type strains and clinical isolates was demonstrated, with no cross-reactivity with other Neisseria spp. or with a comprehensive panel of other common human pathogens. The lower limit of detection was 6 ctrA gene copies detectable in 48 min, with positive reactions readily identifiable visually via a simple color change. Higher copy numbers could be detected in as little as 16 min. When applied to a total of 394 clinical specimens, the LAMP assay in comparison to a conventional TaqMan® based real-time polymerase chain reaction system demonstrated a sensitivity of 100% and a specificity of 98.9% with a ? coefficient of 0.942. The LAMP method represents a rapid, sensitive, and highly specific technique for the detection of N. meningitidis and has the potential to be used as a point-of-care molecular test and in resource-poor settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Energy levels, radiative rates, oscillator strengths, line strengths, and lifetimes have been calculated for transitions in B-like to F-like Xe ions, Xe L–XLVI. For the calculations, a fully relativistic grasp code has been adopted, and results are reported for all electric dipole, electric quadrupole, magnetic dipole, and magnetic quadrupole transitions among the lowest 125, 236, 272, 226, and 113 levels of Xe L, Xe XLIX, Xe XLVIII, Xe XLVII, and Xe XLVI, respectively, belonging to the n ⩽ 3 configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare clinical age-related maculopathy (ARM) grading using slit-lamp biomicroscopy (SLB) versus photographic grading of stereoscopically captured fundus photographs (FP) using a high-resolution fundus camera.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photoionization cross section calculations on the halogen-like ions; Kr + and Xe + have been performed for a photon energy range from each ion threshold to 15 eV, using large-scale close-coupling calculations within the Dirac--Coulomb R -matrix approximation. The results from our theoretical work are compared with recent measurements made at the ASTRID merged-beam set-up at the University of Aarhus in Denmark and from the Fourier transform ion cyclotron resonance trap method at the SOLEIL synchrotron radiation facility in Saint-Aubin, France Bizau et al (2011 J. Phys. B: At. Mol. Opt. Phys. 44 055205) and the advanced light source M{ü}ller (2012 private communication), Aguliar et al (2012 J. Phys.: Conf. Ser . at press). For each of these complex ions our theoretical cross section results over the photon energy range investigated are seen to be in excellent agreement with experiment. Resonance energy positions and quantum defects of the prominent Rydberg resonances series identified in the spectra are compared with experiment for these complex halogen-like ions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Configuration-average distorted-wave calculations are carried out for the electron-impact single ionization of Xe 24 + . Contributions are included from direct ionization of the 3s, 3p, 3d and 4s subshells and from indirect ionization via 3s → nl , 3p → nl and 3d → nl excitations followed by autoionization. Branching ratios are found for single versus double ionization of the 3s and 3p subshells and for autoionization versus radiative decay of all 3 l → nl excitations. Additional distorted-wave and R -matrix calculations find resonant-capture double-autoionization contributions to be quite small. The total ionization cross section for Xe 24 + is found to be dominated by indirect excitation–autoionization contributions, especially near the single-ionization threshold. An approximate 15% reduction in the total ionization cross section is found due to the radiative decays included in the branching ratios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have carried out a 129 close-coupling level Dirac-Coulomb R-matrix calculation for the electron-impact excitation of Ni-like Xe. We have utilized this data to generate the spectral signature of Xe26+ in terms of feature photon-emissivity coefficients (F-PεCs). We have compared these F-PεCs with those generated using semi-relativistic plane-wave Born excitation data, which forms the heavy species baseline for the Atomic Data and Analysis Structure (ADAS), We find that the Born-based F-PεCs give a reasonable qualitative description of the spectral signature but that, quantitatively, the R-matrix-based F-PεCs differ by up to a factor of 2. The spectral signature of heavy species is key to diagnosing hot plasmas such as will be found in the International Thermonuclear Experimental Reactor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-resolution photoionization measurements of Xe + ions have been performed at the Advanced Light Source in Berkeley, California, USA. The experimental cross sections are compared with results from Dirac-Coulomb R-matrix calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Double photoionization accompanied by loss of n C atoms (n=0, 2, 4, 6) was investigated by merging beams of Xe@C60+ ions and synchrotron radiation and measuring the yields of product ions. The giant 4d dipole resonance of the caged Xe atom has a prominent signature in the cross section for these product channels, which together account for 6.2 ± 1.4 of the total Xe 4d oscillator strength of 10. Compared to that for a free Xe atom, the oscillator strength is redistributed in photon energy due to multipath interference of outgoing Xe 4d photoelectron waves that may be transmitted or reflected by the spherical C60+ molecular cage, yielding so-called confinement resonances. The data are compared with an earlier measurement and with theoretical predictions for this single-molecule photoelectron interferometer system. Relativistic R-matrix calculations for the Xe atom in a spherical potential shell representing the fullerene cage show the sensitivity of the interference pattern to the molecular geometry. © 2013 American Physical Society.