937 resultados para Wind-induced Natural Ventilation
Resumo:
In this letter, a new wind-vector algorithm is presented that uses radar backscatter sigma(0) measurements at two adjacent subscenes of RADARSAT-1 synthetic aperture radar (SAR) images, with each subscene having slightly different geometry. Resultant wind vectors are validated using in situ buoy measurements and compared with wind vectors determined from a hybrid wind-retrieval model using wind directions determined by spectral analysis of wind-induced image streaks and observed by colocated QuikSCAT measurements. The hybrid wind-retrieval model consists of CMOD-IFR2 [applicable to C-band vertical-vertical (W) polarization] and a C-band copolarization ratio according to Kirchhoff scattering. The new algorithm displays improved skill in wind-vector estimation for RADARSAT-1 SAR data when compared to conventional wind-retrieval methodology. In addition, unlike conventional methods, the present method is applicable to RADARSAT-1 images both with and without visible streaks. However, this method requires ancillary data such as buoy measurements to resolve the ambiguity in retrieved wind direction.
Resumo:
High pollution levels have been often observed in urban street canyons due to the increased traffic emissions and reduced natural ventilation. Microscale dispersion models with different levels of complexity may be used to assess urban air qualityand support decision-making for pollution control strategies and traffic planning. Mathematical models calculate pollutant concentrations by solving either analytically a simplified set of parametric equations or numerically a set of differential equations that describe in detail wind flow and pollutant dispersion. Street canyon models, which might also include simplified photochemistry and particle deposition–resuspension algorithms, are often nested within larger-scale urban dispersion codes. Reduced-scale physical models in wind tunnels may also be used for investigating atmospheric processes within urban canyons and validating mathematical models. A range of monitoring techniques is used to measure pollutant concentrations in urban streets. Point measurement methods (continuous monitoring, passive and active pre-concentration sampling, grab sampling) are available for gaseous pollutants. A number of sampling techniques (mainlybased on filtration and impaction) can be used to obtain mass concentration, size distribution and chemical composition of particles. A combination of different sampling/monitoring techniques is often adopted in experimental studies. Relativelysimple mathematical models have usually been used in association with field measurements to obtain and interpret time series of pollutant concentrations at a limited number of receptor locations in street canyons. On the other hand, advanced numerical codes have often been applied in combination with wind tunnel and/or field data to simulate small-scale dispersion within the urban canopy.
Resumo:
Natural ventilation is a sustainable solution to maintaining healthy and comfortable environmental conditions in buildings. However, the effective design, construction and operation of naturally ventilated buildings require a good understanding of complex airflow patterns caused by the buoyancy and wind effects.The work presented in this article employed a 3D computational fluid dynamics (CFD) analysis in order to investigate environmental conditions and thermal comfort of the occupants of a highly-glazed naturally ventilated meeting room. This analysis was facilitated by the real-time field measurements performed in an operating building, and previously developed formal calibration methodology for reliable CFD models of indoor environments. Since, creating an accurate CFD model of an occupied space in a real-life scenario requires a high level of CFD expertise, trusted experimental data and an ability to interpret model input parameters; the calibration methodology guided towards a robust and reliable CFD model of the indoor environment. This calibrated CFD model was then used to investigate indoor environmental conditions and to evaluate thermal comfort indices for the occupants of the room. Thermal comfort expresses occupants' satisfaction with thermal environment in buildings by defining the range of indoor thermal environmental conditions acceptable to a majority of occupants. In this study, the thermal comfort analysis, supported by both field measurements and CFD simulation results, confirmed a satisfactory and optimal room operation in terms of thermal environment for the investigated real-life scenario. © 2013 Elsevier Ltd.
Resumo:
Le traumatisme de la moelle épinière est à l’origine d’une inflammation locale importante caractérisée par l’augmentation massive des cellules inflammatoires et la présence de réactions oxydatives. Cette inflammation locale peut déclencher une réponse inflammatoire systémique par voie hématogène. Au niveau cervical, les lésions médullaires peuvent entraîner des faiblesses ou la paralysie des muscles respiratoires. Le patient, qui ne peut plus respirer de façon autonome, doit avoir recours à un support respiratoire. Bien que la ventilation mécanique soit la thérapie traditionnellement appliquée aux blessés médullaires souffrant d’insuffisance respiratoire, les études ont démontré qu’elle pouvait contribuer à promouvoir une réponse inflammatoire ainsi que des dommages pulmonaires. L’interaction entre le traumatisme médullaire et la ventilation mécanique, indispensable au maintien de l’équilibre des échanges respiratoires, est inconnue à ce jour. En voulant protéger les tissus, cellules et organes, l’organisme met en œuvre toute une panoplie de réponses inflammatoires à différents endroits. Nous pensons que ces réponses peuvent être altérées via l’interaction entre ce traumatisme et cette ventilation mécanique, sous l’influence de la principale source cellulaire de cytokines pour la défense de l’hôte, le macrophage, récemment classé en deux phénotypes principaux: 1) l’activation classique de type M1 et 2) l’activation alternative de type M2. Le phénotype M1 est conduit par le facteur GM-CSF et induit par l’interféron IFN-ɣ ainsi que le lipopolysaccharide. Le phénotype M2 quant à lui, est conduit par le facteur M-CSF et induit par les interleukines IL-4, IL-13 ou IL-21. M1 relâche principalement IL-1β, IL-6, TNF-α et MIP-1α tandis que M2 principalement IL-10 et MCP-1. Toutefois, nous ignorons actuellement par quel type d’activation se manifestera cette réponse immunitaire et si l’application de support respiratoire pourrait entraîner un risque inflammatoire additionnel au site du traumatisme. Nous ignorons également si la ventilation mécanique affecterait, à distance, les tissus de la moelle épinière via une inflammation systémique et amplifierait alors le dommage initial. Il n’existe pas à ce jour, de thérapie qui ait montré d’effet bénéfique réel envers une récupération fonctionnelle des patients blessés médullaires. Il paraît donc essentiel de déterminer si la ventilation mécanique peut moduler l’inflammation post-traumatique à la fois au niveau pulmonaire et au site de la lésion. Ce travail visait à caractériser les liens entre l’inflammation issue du traumatisme médullaire et celle issue de la ventilation, dans le but de fournir une meilleure compréhension des mécanismes inflammatoires activés dans ce contexte. L’étude a été menée sur un modèle animal. Elle consistait à évaluer : 1) si le traumatisme médullaire influençait les réponses inflammatoires pulmonaires induites par la ventilation mécanique, y compris le phénotype des macrophages alvéolaires et 2) si la ventilation pouvait altérer à distance, les tissus de la moelle épinière. L’impact de la blessure médullaire sur l’inflammation pulmonaire et locale, induite par la ventilation fut interprété grâce à l’analyse des cellules inflammatoires dans les lavages broncho-alvéolaires et dans les tissus prélevés à l’endroit de la blessure après 24 heures. Ces analyses ont démontré un profil spécifique des cytokines pulmonaires et médullaires. Elles ont révélé que la ventilation mécanique a engendré un environnement pro-inflammatoire en faveur d’un phénotype M1 chez les animaux ayant bénéficié de la thérapie respiratoire. Inversement, l’atteinte thoracique chez les animaux sans ventilation, a montré qu’une réponse immunitaire avait été activée en faveur d’un environnement anti-inflammatoire de phénotype M2. La lésion cervicale quant à elle a induit un profil de cytokines différent et les réponses au stress oxydatif dans le poumon induites par la ventilation ont été réduites significativement. De plus, une lésion médullaire a augmenté l’expression d’IL-6 et la ventilation a diminué l’IL-1β et augmenté le TNF-α dans les tissus de la moelle. Finalement, ces données ont fourni les premières évidences que la ventilation a induit d’avantage à un phénotype pulmonaire M1 et que le traumatisme médullaire a impacté spécifiquement les réponses inflammatoires et oxydatives dans le poumon. La ventilation a contribué non seulement à distance à une inflammation des tissus médullaires lésés mais aussi des tissus sains.
Resumo:
This article addresses the need for providing good standards of indoor air quality (IAQ) in buildings from the view point of health, well-being and productivity of building occupants. It briefly outlines the role of ventilation in achieving the required IAQ targets and discusses the performance of different types of ventilation systems in use. As a result of new energy efficiency directives and legislations in Europe and elsewhere, the ventilation energy component of HVAC systems has increased in relative terms and this article introduces a method for evaluating the performance air distribution systems that is based on ventilation and energy effectiveness. A range of ventilation systems are discussed, including mechanical and natural ventilation, and results for more recently developed mechanical air distribution systems are compared with conventional systems. The article provides an assessment and comparison of some of these systems with reference to ventilation performance and energy efficiency
Resumo:
Systematic natural ventilation effects on measured temperatures within a standard large wooden thermometer screen are investigated under summer conditions, using well-calibrated platinum resistance thermometers. Under low ventilation (2mwind speed u2 < 1.1 m s−1), the screen slightly underestimates daytime air temperature but overestimates air temperature nocturnally by 0.2◦C. The screen’s lag time L lengthens with decreasing wind speed, following an inverse power law relationship between L and u2. For u2 > 2 m s−1, L ∼ 2.5 min, increasing, when calm, to at least 15 min. Spectral response properties of the screen to air temperature fluctuations vary with wind speed because of the lag changes. Ventilation effects are particularly apparent at the higher (>25◦C) temperatures, both through the lag effect and from solar heating. For sites where wind speed decreases with increasing daytime temperature, thermometer screen temperatures may consequently show larger uncertainties at the higher temperatures. Under strong direct beam solar radiation (>850W m−2) the radiation effect is likely to be <0.4◦C. Copyright c 2011 RoyalMeteorological Society
Resumo:
Airflow through urban environments is one of the most important factors affecting human health, outdoor and indoor thermal comfort, air quality and the energy performance of buildings. This paper presents a study on the effects of wind induced airflows through urban built form using statistical analysis. The data employed in the analysis are from the year-long simultaneous field measurements conducted at the University of Reading campus in the United Kingdom. In this study, the association between typical architectural forms and the wind environment are investigated; such forms include: a street canyon, a semi-closure, a courtyard form and a relatively open space in a low-rise building complex. Measured data captures wind speed and wind direction at six representative locations and statistical analysis identifies key factors describing the effects of built form on the resulting airflows. Factor analysis of the measured data identified meteorological and architectural layout factors as key factors. The derivation of these factors and their variation with the studied built forms are presented in detail.
Resumo:
This work analyses a study on natural ventilation and its relation to the urban legislation versus the building types in an urban fraction of coastal area of Praia do Meio in the city of Natal/RN, approaching the type or types of land use most appropriate to this limited urban fraction. The objective of this study is to analyse the effects of the present legislation as well as the types of buildings in this area on the natural ventilation. This urban fraction was selected because it is one of the sites from where the wind flows into the city of Natal. This research is based on the hypothesis stating that the reduction on the porosity of the urban soil (decrease in the set back/boundary clearance), and an increase in the form (height of the buildings) rise the level of the ventilation gradient, consequently causing a reduction on the wind speed at the lowest part of the buildings. Three-dimensional computational models were used to produce the modes of occupation allowed in the urban fraction within the area under study. A Computational Fluid Dynamics (CFD) software was also used to analyse the modes of land occupation. Following simulation, a statistical assessment was carried out for validation of the hypothesis. It was concluded that the reduction in the soil porosity as a consequence of the rates that defined the minimum boundary clearance between the building and the boundary of the plot (and consequently the set back), as well as the increase in the building form (height of the buildings) caused a reduction in the wind speed, thus creating heat islands
Resumo:
Natural ventilation is an efficient bioclimatic strategy, one that provides thermal comfort, healthful and cooling to the edification. However, the disregard for quality environment, the uncertainties involved in the phenomenon and the popularization of artificial climate systems are held as an excuse for those who neglect the benefits of passive cooling. The unfamiliarity with the concept may be lessened if ventilation is observed in every step of the project, especially in the initial phase in which decisions bear a great impact in the construction process. The tools available in order to quantify the impact of projected decisions consist basically of the renovation rate calculations or computer simulations of fluids, commonly dubbed CFD, which stands for Computational Fluid Dynamics , both somewhat apart from the project s execution and unable to adapt for use in parametric studies. Thus, we chose to verify, through computer simulation, the representativeness of the results with a method of simplified air reconditioning rate calculation, as well as making it more compatible with the questions relevant to the first phases of the project s process. The case object consists of a model resulting from the recommendations of the Código de Obras de Natal/ RN, customized according to the NBR 15220. The study has shown the complexity in aggregating a CFD tool to the process and the need for a method capable of generating data at the compatible rate to the flow of ideas and are discarded during the project s development. At the end of our study, we discuss the necessary concessions for the realization of simulations, the applicability and the limitations of both the tools used and the method adopted, as well as the representativeness of the results obtained
Resumo:
The present work studies the natural ventilation and its relationship with the urban standards, which establishes the form of occupation and use of the land in our cities. The method simulates the application of the urban standards of the City Master Plan over the last three years. The simulation takes place in the District of Petrópolis, in the city of Natal , Brazil and analyses the effects of the standards of natural ventilation. The formulated hypothesis states that the reductions in the urban spaces between buildings rises up the vertical profile of ventilation, reducing, therefore, the velocity of the wind at the lower levels of the buildings. To develop the study, occupation models were built, using computerized, three-dimensional models. These occupation models were analyzed using the CFD (Computational Fluid Dynamics) code. The conclusion is that the more we reduce the urban space between buildings, the more we reduce the wind speed in constructed areas, increasing, therefore, the possibility to generate heat islands
Resumo:
A presente dissertação de mestrado estuda o desempenho térmico de materiais de fachada em uma edificação verticalizada na cidade de Belém – PA, Brasil. Este trabalho tem por objetivo contribuir com estudo do desempenho térmico e eficiência de materiais utilizados na envoltória das edificações residenciais verticalizadas, entre os elementos opacos, foram selecionados dois tipos de materiais, bastante utilizados atualmente na construção civil, a pintura e revestimento cerâmico. Também estuda-se a influência da altura da edificação sobre seu desempenho térmico e eficiência energética. O estudo foi desenvolvido com o uso de modelagem em código computacional no programa EnergyPlus que permite avaliar o desempenho térmico da edificação, a influência da altura na eficiência energética da mesma. Compara-se o desempenho térmico dos dois materiais selecionados, verificou-se que o prédio com revestimento cerâmico apresentou a temperatura interna média anual de 0,42 º C acima da temperatura referente ao prédio pintado, portanto com menor desempenho térmico. A influência da altura do pavimento não produziu uma variação significativa na temperatura interna, pois com seu acréscimo, ocorreu pequena diminuição da temperatura interna, com gradiente térmico da ordem de -0,07ºC /m em decorrência da velocidade do vento que é maior quando mais alto é o pavimento. Considera-se também para este estudo a ventilação natural como estratégia passiva para a edificação em estudo, que segundo a análise da Carta Bioclimática de Givoni contribuiria positivamente para a condição de temperatura interna e umidade do ar, e consequentemente do usuário.
Resumo:
Estratégias passivas de projeto reduzem significativamente o uso de ar condicionado e melhoram o conforto térmico dos usuários. Isto pode ser ilustrado através dos hospitais da Rede Sarah Kubitschek projetados pelo arquiteto João Filgueiras Lima, Lelé, cujas soluções além de propiciarem ambientes mais agradáveis e salubres, evitam o uso de sistemas mecânicos de resfriamento, reduzindo o consumo de energia elétrica. Deste modo, o presente artigo tem como objetivo avaliar o conforto térmico dos hospitais Sarah de Salvador e do Rio de Janeiro, através de medições in loco da temperatura do ar, umidade relativa do ar e velocidade do ar. A análise dos resultados foi baseada em leituras de projeto, na norma ASHRAE Standard 55/2004 e em parâmetros adquiridos na literatura especializada. Os resultados demonstram a preocupação de Lelé na incorporação de aspectos bioclimáticos nos projetos. No Sarah - Salvador, alguns ambientes permaneceram fora da zona de conforto no período do meio dia, devido ao ganho de calor pela cobertura. No entanto, o uso da ventilação natural auxilia no efeito de resfriamento, melhorando o conforto térmico nos espaços internos. Já no Sarah - Rio, todos os ambientes permanecem dentro da zona de conforto proposta pela ASHRAE 55.
Resumo:
The modern eastern equatorial Pacific (EEP) is a major natural source for atmospheric carbon dioxide and is thought to be connected to high-latitude ocean dynamics by oceanic teleconnections on glacial-interglacial timescales. A wealth of sedimentary records aiming at reconstructing last Quaternary changes in primary productivity and nutrient utilization have been devoted to understanding those linkages between the EEP and other distant oceanic areas. Most of these records are, however, clustered in the pelagic EEP cold tongue, with comparatively little attention devoted to coastal areas. Here we present downcore measurements of the composition and concentration of the diatom assemblage together with opal (biogenic silica) concentration at site MD02-2529 recovered in the coastal Panama Basin. Piston core MD02-2529, collected in an area affected by a multitude of processes, provides evidence for strong variations in diatom production at the millennial timescale during the last glacial cycle. The maxima in total diatom concentration occurred during the early marine isotopic stage (MIS) 4 as well as during the MIS 4/3 transition and MIS 3. Rapid changes in diatom concentrations during the MIS 3 mimics Bond cycles as independently recorded by the SSS estimation derived from planktonic foraminifera from the same core. Such patterns indicate a clear linkage between diatom production in the coastal EEP and rapid climate changes in the high-latitude North Atlantic. In parallel, the long-term succession of the diatom community from coastal diatoms, predominantly thriving during MIS 5 and 4, towards pelagic diatoms, dominant during MIS 3 and 2, points to a long-term change in the surface hydrology. During Heinrich Events, diatoms strongly reduced their production, probably due to enhanced stratification in the upper water column. After the last glacial maximum, diatom production and valve preservation strongly decreased in response to the advection of nutrient (H2SiO4)-depleted, warmer water masses. Our high-resolution record highlights how regional climatic processes can modulate rapid changes in siliceous primary production as triggered by wind-induced local upwelling, indicating that millennial climatic variability can overtake other prominent hydrological processes such as those related to silicic acid leakage.
Resumo:
Tall buildings are wind-sensitive structures and could experience high wind-induced effects. Aerodynamic boundary layer wind tunnel testing has been the most commonly used method for estimating wind effects on tall buildings. Design wind effects on tall buildings are estimated through analytical processing of the data obtained from aerodynamic wind tunnel tests. Even though it is widely agreed that the data obtained from wind tunnel testing is fairly reliable the post-test analytical procedures are still argued to have remarkable uncertainties. This research work attempted to assess the uncertainties occurring at different stages of the post-test analytical procedures in detail and suggest improved techniques for reducing the uncertainties. Results of the study showed that traditionally used simplifying approximations, particularly in the frequency domain approach, could cause significant uncertainties in estimating aerodynamic wind-induced responses. Based on identified shortcomings, a more accurate dual aerodynamic data analysis framework which works in the frequency and time domains was developed. The comprehensive analysis framework allows estimating modal, resultant and peak values of various wind-induced responses of a tall building more accurately. Estimating design wind effects on tall buildings also requires synthesizing the wind tunnel data with local climatological data of the study site. A novel copula based approach was developed for accurately synthesizing aerodynamic and climatological data up on investigating the causes of significant uncertainties in currently used synthesizing techniques. Improvement of the new approach over the existing techniques was also illustrated with a case study on a 50 story building. At last, a practical dynamic optimization approach was suggested for tuning structural properties of tall buildings towards attaining optimum performance against wind loads with less number of design iterations.
Resumo:
The increasing nationwide interest in intelligent transportation systems (ITS) and the need for more efficient transportation have led to the expanding use of variable message sign (VMS) technology. VMS panels are substantially heavier than flat panel aluminum signs and have a larger depth (dimension parallel to the direction of traffic). The additional weight and depth can have a significant effect on the aerodynamic forces and inertial loads transmitted to the support structure. The wind induced drag forces and the response of VMS structures is not well understood. Minimum design requirements for VMS structures are contained in the American Association of State Highway Transportation Officials Standard Specification for Structural Support for Highway Signs, Luminaires, and Traffic Signals (AASHTO Specification). However the Specification does not take into account the prismatic geometry of VMS and the complex interaction of the applied aerodynamic forces to the support structure. In view of the lack of code guidance and the limited number research performed so far, targeted experimentation and large scale testing was conducted at the Florida International University (FIU) Wall of Wind (WOW) to provide reliable drag coefficients and investigate the aerodynamic instability of VMS. A comprehensive range of VMS geometries was tested in turbulence representative of the high frequency end of the spectrum in a simulated suburban atmospheric boundary layer. The mean normal, lateral and vertical lift force coefficients, in addition to the twisting moment coefficient and eccentricity ratio, were determined using the measured data for each model. Wind tunnel testing confirmed that drag on a prismatic VMS is smaller than the 1.7 suggested value in the current AASHTO Specification (2013). An alternative to the AASHTO Specification code value is presented in the form of a design matrix. Testing and analysis also indicated that vortex shedding oscillations and galloping instability could be significant for VMS signs with a large depth ratio attached to a structure with a low natural frequency. The effect of corner modification was investigated by testing models with chamfered and rounded corners. Results demonstrated an additional decrease in the drag coefficient but a possible Reynolds number dependency for the rounded corner configuration.