977 resultados para Water Pollution, Chemical
Pollution by hexachlorobenzene and pentachlorophenol in the coastal plain of São Paulo state, Brazil
Resumo:
Organochlorine compounds were dumped by chemical industries during the 1970s in many areas of the coastal plain of São Paulo state in Brazil. These dumps, located on hillsides and in valleys, in both rural and urban environments, are responsible for soil and water pollution. The objective of this work was to determine how the pollutants have spread in an area occupied by a spodosol-type soil mantle. The study combines soil morphological observations with soil and water analysis of hexachlorobenzene (HCB) and pentachlorophenol (PCP) in soil toposequences. The results indicate that the highest pollutant concentrations are observed near the dump site and that the compounds contamination is increasing. A map integrating topography and chemical concentrations was created to visualize the spatial distribution of HCB levels in the landscape. Physical and chemical analyses were performed to measure HCB and PCP levels in the soil. Soil water appears to act as a vector of HCB, probably through complexation with and dispersal of dissolved organic matter. The persistence of HCB at the studied site is most likely due to the low pH values in combination with a high content of organic matter. HCB was consistently found in higher concentrations than PCP. It is plausible that the cause of this difference is that PCP is degraded more easily under sunlight than HCB and that degradation of PCP under acid conditions leads to the formation of HCB. © 2003 Published by Elsevier B.V.
Resumo:
The Lagoon of Venice is a large water basin that exchanges water with the Northern Adriatic Sea through three large inlets. We examined two adjacent sites within the Southern Basin and at the Chioggia inlet in autumn 2007 and summer 2008. A pilot study in June 2007 on a surface water sample from Chioggia with a rather high salinity of 36.9 PSU had revealed a conspicuous bloom of CF319a-positive cells likely affiliated with the Cytophaga /Flavobacteria cluster of Bacteroidetes. These flavobacterial abundances were one to two orders of magnitude higher than in other marine surface waters. DAPI-stained cells were identified as bacteria with the general bacterial probe mixture EUB338 I-III. CARD-FISH counts with group-specific probes confirmed the dominance of Bacteroidetes (CF319a), Alphaproteobacteria (ALF968), and Gammaproteobacteria (GAM42a). CARD-FISH showed thatBetaproteobacteria and Planctomycetes were minor components of the bacterioplankton in the Lagoon of Venice.
Resumo:
Cover title.
Resumo:
On cover: Investigations of Illinois surface waters.
Resumo:
This document was prepared in response to a recommendation by the Governor's Small Business Environmental Task Force. It is intended to provide a guide or roadmap to assist you in determining whether your business requires an Air, Land or Water Pollution Control Permit from the Illinois EPA.
Resumo:
The chemical properties of deep profile samples ( up to 12 m) of Ferrosols from northern Queensland were investigated to provide an understanding of the accumulation of nitrate ( NO3) within these soil profiles. The influence of other cations and anions present in the soil solution or on the exchange and the charge chemistry of the profiles were examined with respect to the NO3 accumulations. The major ions in the soil solution were Na, NO3, and chloride ( Cl). Distinct regions of anion accumulation were observed; SO4 accumulated in the upper profile of all cores, whereas NO3 and Cl accumulations were restricted to the lower profile of cores with appreciable AEC (> 1 cmol(c)/kg). Gaines-Thomas selectivity coefficients were used to indicate exchange preference for cations and anions, and are as follows: Al > Ca similar to Mg > K > Na and sulfate (SO4) > Cl similar to NO3. The selectivity of SO4 increased and the extractable SO4 decreased in the lower profile of all cores. This has important implications for the adsorption of NO3 and Cl. The NO3 and Cl accumulations were shown to correspond to a region of low SO4 occupancy of the exchange sites in the lower profile. Along with the high SO4 selectivity, this suggests that SO4 may control the positioning of the NO3 accumulations. It was concluded that the NO3 accumulations were relatively stable under current management practices, although the reduction in NO3 inputs would likely see the gradual replacement of NO3 with Cl as a result of their comparable selectivity for exchange sites.
Resumo:
A gestão dos recursos hídricos necessita da integração entre os critérios físicos e químicos, e os aspectos bióticos, os quais possibilitam identificar os efeitos combinados de substâncias e avaliar suas influências. Os sistemas testes Allium cepa e Tradescantia pallida, são utilizados para o estudo da poluição aquática a partir de aspectos citogenéticos. Além destes biomarcadores, os teores de clorofila também são utilizados em estudos de estresse devido ao reflexo a múltiplos fatores. Assim, o objetivo deste trabalho foi avaliar a qualidade da água da lagoa Juara (Município de Serra/ES) pela análise integrada de aspectos físicos, químicos e ecotoxicológicos a partir de estudos citogenéticos em A. cepa e T. pallida, e fotossintéticos nesta última espécie. Foram definidas três estações amostrais ao longo da lagoa e a partir de amostras de água foram analisados parâmetros tais como condutividade, oxigênio dissolvido, concentração de nutrientes e metais. A determinação dos metais ocorreu por análises de espectrometria de massa. O teste do A. cepa foi realizado a partir sementes germinadas em amostras de água da lagoa. Com plantas de T. pallida, foi realizado o ensaio da mitose em ponta de raiz de T. pallida e dosado os teores de pigmentos cloroplastídicos em folhas totalmente expandidas. Para tanto, foi realizado ensaio utilizando-se a água da lagoa como solvente para solução de Hoagland onde estacas previamente enraizadas de T. pallida foram expostas durante 24 horas e 40 dias para as avaliações citogenéticas e fotossintéticas, respectivamente. Foi realizado novo teste do A. cepa nas águas da lagoa após os 40 dias de ensaio para aferir a manutenção das propriedades químicas das amostras. A avaliação citogenética nas duas espécies envolveu a análise dos índice mitótico (IM), índice de aberrações cromossômicas (AC) e frequência de micronúcleos (MN). Para a análise estatística foi utilizada a análise de variância seguida pelo teste de Tukey (p < 0.05) para a comparação dos tratamentos durante a mesma campanha, e teste de Bonferroni (p < 0,05) para a comparação entre as campanhas. Os resultados físicos e químicos mensurados demonstram que a lagoa Juara apresenta indícios de eutroficação artificial. Duas estações amostrais, em pelo menos uma campanha amostral, apresentaram potenciais citotóxico, genotóxico e mutagênico. Todavia, esses potenciais não demonstram relação com os teores de Fe e Mn quantificados, levando a crer que tais pontos apresentam outros potenciais poluentes. Os danos citogenéticos observados apresentaram efeitos maximizados durante a segunda campanha, demostrando o efeito do período de chuva na intensificação da poluição nesse ambiente. O estudo do metabolismo fotossintético em T. pallida, demonstrou os teores de pigmentos cloroplastídicos relacionados ao elevado aporte de nutrientes presentes nas estações J2 e J3. Sendo o excesso destes, o provável responsável pelo teor inferior de pigmentos em J3. Observa-se que os ensaios com A. cepa e T. pallida responderam de maneira fidedigna ao risco potencial do ambiente, complementando as análises físicas e químicas usualmente utilizadas na avaliação da qualidade da água de ambientes lacustres.
Resumo:
OBJECTIVE: To assess the impact of town planning, infrastructure, sanitation and rainfall on the bacteriological quality of domestic water supplies. METHODS: Water samples obtained from deep and shallow wells, boreholes and public taps were cultured to determine the most probable number of Escherichia coli and total coliform using the multiple tube technique. Presence of enteric pathogens was detected using selective and differential media. Samples were collected during both periods of heavy and low rainfall and from municipalities that are unique with respect to infrastructure planning, town planning and sanitation. RESULTS: Contamination of treated and pipe distributed water was related with distance of the collection point from a utility station. Faults in pipelines increased the rate of contamination (p<0.5) and this occurred mostly in densely populated areas with dilapidated infrastructure. Wastewater from drains was the main source of contamination of pipe-borne water. Shallow wells were more contaminated than deep wells and boreholes and contamination was higher during period of heavy rainfall (p<0.05). E. coli and enteric pathogens were isolated from contaminated supplies. CONCLUSIONS: Poor town planning, dilapidated infrastructure and indiscriminate siting of wells and boreholes contributed to the low bacteriological quality of domestic water supplies. Rainfall accentuated the impact.
Resumo:
OBJECTIVE: To evaluate the microbiological quality of treated and untreated water samples came from urban and rural communities and to examine the relationship between coliforms occurrence and average water temperature, and a comparison of the rainfall levels. METHODS: A sample of 3,073 untreated and treated (chlorinated) water from taps (1,594), reservoir used to store treated water (1,033), spring water (96) and private well (350) collected for routine testing between 1996 and 1999 was analyzed by the multiple dilution tube methods used to detect the most probable number of total and fecal coliforms. These samples were obtained in the region of Maringá, state of Paraná, Brazil. RESULTS: The highest numbers water samples contaminated by TC (83%) and FC (48%) were found in the untreated water. TC and FC in samples taken from reservoirs used to store treated water was higher than that from taps midway along distribution lines. Among the treated water samples examined, coliform bacteria were found in 171 of the 1,033 sampling reservoirs. CONCLUSIONS: Insufficient treatment or regrowth is suggested by the observation that more than 17% of these treated potable water contained coliform. TC and FC positive samples appear to be similar and seasonally influenced in treated water. Two different periods must be considered for the occurrence of both TC and FC positive samples: (i) a warm-weather period (September-March) with high percentage of contaminated samples; and (ii) cold-weather period (April-August) were they are lower. Both TC and TF positive samples declined with the decreased of water temperature.
Resumo:
A existência de estações de tratamentos de águas residuais (ETAR) é, nos dias de hoje, fundamental na medida em que permite, reduzir a poluição ambiental associada às águas e, também, a reutilização da água tratada para diversos fins. A constante necessidade de cumprir os limites de descargas nos meios recetores conduziu a um melhoramento nas técnicas e processos de tratamento de efluentes, nomeadamente, nos processos biológicos. O processo por lamas ativadas é um processo amplamente utilizado para a remoção de poluentes orgânicos presentes nas águas residuais, pelo que um estudo mais intensivo sobre estes tratamentos resultou na publicação de uma série de conceitos e pressupostos, através de modelos numéricos. A modelação numérica de processos de tratamento de águas residuais e a utilização de ferramentas de simulação numérica têm sido largamente utilizadas, a nível mundial, por exemplo em investigação, desenvolvimento de processos, atividade de consultoria e igualmente por entidades reguladoras, na medida em que os auxiliam no planeamento, dimensionamento e análise do comportamento de infraestruturas de tratamento. No presente trabalho, recorreu-se ao software de simulação GPS-X (versão 6.0) para implementar o esquema de tratamento da ETAR de Beirolas. O objetivo deste trabalho é verificar a aplicabilidade de modelos numéricos na simulação de unidades de tratamento de efluentes e avaliar a resposta dos diferentes modelos, assim como a influência na alteração de características das águas afluentes no comportamento dos modelos. Os resultados obtidos permitiram concluir que os modelos numéricos podem ser utilizados para prever a resposta dos sistemas biológicos e as suas perturbações. Conclui-se ainda que o comportamento, dos modelos estudados (ASM1, ASM2d, ASM3 e mantis), é semelhante, contudo deve-se referir que devido à complexidade do modelo e a falta de informação experimental sobre as características do efluente, não permitiram efetuar uma completa caracterização e calibração do caso de estudo, e toda a informação disponível sobre as características físico-químicas da água foram baseadas em estimativas de concentrações de carências de oxigénio e sólidos suspensos.
Resumo:
Dissertation elaborated for the partial fulfilment of the requirements of the Master Degree in Civil Engineering in the Speciality Area of Hydarulics
Resumo:
OBJECTIVE: To assess the health risk of exposure to benzene for a community affected by a fuel leak. METHODS: Data regarding the fuel leak accident with, which occurred in the Brasilia, Federal District, were obtained from the Fuel Distributor reports provided to the environmental authority. Information about the affected population (22 individuals) was obtained from focal groups of eight individuals. Length of exposure and water benzene concentration were estimated through a groundwater flow model associated with a benzene propagation model. The risk assessment was conducted according to the Agency for Toxic Substances and Disease Registry methodology. RESULTS: A high risk perception related to the health consequences of the accident was evident in the affected community (22 individuals), probably due to the lack of assistance and a poor risk communication from government authorities and the polluting agent. The community had been exposed to unsafe levels of benzene (> 5 µg/L) since December 2001, five months before they reported the leak. The mean benzene level in drinking water (72.2 µg/L) was higher than that obtained by the Fuel Distributer using the Risk Based Corrective Action methodology (17.2 µg/L).The estimated benzene intake from the consumption of water and food reached a maximum of 0.0091 µg/kg bw/day (5 x 10-7 cancer risk per 106 individuals). The level of benzene in water vapor while showering reached 7.5 µg/m3 for children (1 per 104 cancer risk). Total cancer risk ranged from 110 to 200 per 106 individuals. CONCLUSIONS: The population affected by the fuel leak was exposed to benzene levels that might have represented a health risk. Local government authorities need to develop better strategies to respond rapidly to these types of accidents to protect the health of the affected population and the environment.