970 resultados para Water Distribution Networks Infrastructure Health


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of expert system techniques in power distribution system design is examined. The selection and siting of equipment on overhead line networks is chosen for investigation as the use of equipment such as auto-reclosers, etc., represents a substantial investment and has a significant effect on the reliability of the system. Through past experience with both equipment and network operations, most decisions in selection and siting of this equipment are made intuitively, following certain general guidelines or rules of thumb. This heuristic nature of the problem lends itself to solution using an expert system approach. A prototype has been developed and is currently under evaluation in the industry. Results so far have demonstrated both the feasibility and benefits of the expert system as a design aid.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The peer-to-peer content distribution network (PCDN) is a hot topic recently, and it has a huge potential for massive data intensive applications on the Internet. One of the challenges in PCDN is routing for data sources and data deliveries. In this paper, we studied a type of network model which is formed by dynamic autonomy area, structured source servers and proxy servers. Based on this network model, we proposed a number of algorithms to address the routing and data delivery issues. According to the highly dynamics of the autonomy area, we established dynamic tree structure proliferation system routing, proxy routing and resource searching algorithms. The simulations results showed that the performance of the proposed network model and the algorithms are stable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Water quality modelling is becoming increasingly popular in the water industry due to its applications in drinking water and treated wastewater reuse. Microbial growth and disinfectant decay are the two most important factors to be considered in drinking water if they are to comply with stringent guidelines imposed by relevant water regulatory authorities. In the case of drinking water, an optimum level of disinfectant is an important criterion to have pathogen free water with minimal disinfectant by products (DBPs) below the acceptable levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nearly all drinking water distribution systems experience a "natural" reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the "optimum level", considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne's Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water's Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality of drinking water generally degrades when it is delivered through a distribution system due to the decay of disinfectant, which subsequently allows the re-growth of microorganisms in the distribution system. A model that describes the changes that occur in the water quality in distribution system is needed to determine whether to enhance the treatment processes or to improve the distribution system so that microbiological criteria are met. This paper describes how chlorine decay kinetics are modeled and the model output is used in finding the elements that are contributing to the consumption of chlorine at the treatment plant other than the water itself; this allows better control of chlorine dosing at the treatment plant, which in tum will reduce the formation of disinfectant by-products. In addition, the model will accurately predict the decay due to the organic/inorganic and nitrogenous compounds that are remaining in the water at any point in the distribution system, which will indicate the status of the distribution system with respect to its chlorine consumption. Further, if re-chlorination is introduced in the distribution system downstream of the treatment plant, the model will predict the chlorine decay due to the slow reacting organic and nitrogenous compounds accurately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dynamic water quality model for drinking water distribution systems has been developed in this study, to include processes that occur in the bulk water, as well as those occurring in the biofilm of a distribution system. The model has been validated against water quality data obtained from extensive experimental studies conducted with biofilm reactors. Protein and carbohydrate densities in the biofilm represent biofilm biomass. This model is able to predict the disinfectant decay due to organic matter in the bulk water, as well as that due to biofilm. It simultaneously predicts the growth of biofilm in terms of carbohydrate and protein densities. While this model is complex enough to describe the water quality changes in a distribution system, it is also simple enough to be incorporated into a hydraulic model in order to describe the interaction between disinfectant and microbiological quality throughout a drinking water distribution system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nearly all drinking water distribution systems experience a "natural" reduction of disinfection residuals. The most frequently used disinfectant is chlorine, which can decay due to reactions with organic and inorganic compounds in the water and by liquid/solids reaction with the biofilm, pipe walls and sediments. Usually levels of 0.2-0.5 mg/L of free chlorine are required at the point of consumption to maintain bacteriological safety. Higher concentrations are not desirable as they present the problems of taste and odour and increase formation of disinfection by-products. It is usually a considerable concern for the operators of drinking water distribution systems to manage chlorine residuals at the "optimum level", considering all these issues. This paper describes how the chlorine profile in a drinking water distribution system can be modelled and optimised on the basis of readily and inexpensively available laboratory data. Methods are presented for deriving the laboratory data, fitting a chlorine decay model of bulk water to the data and applying the model, in conjunction with a simplified hydraulic model, to obtain the chlorine profile in a distribution system at steady flow conditions. Two case studies are used to demonstrate the utility of the technique. Melbourne's Greenvale-Sydenham distribution system is unfiltered and uses chlorination as its only treatment. The chlorine model developed from laboratory data was applied to the whole system and the chlorine profile was shown to be accurately simulated. Biofilm was not found to critically affect chlorine decay. In the other case study, Sydney Water's Nepean system was modelled from limited hydraulic data. Chlorine decay and trihalomethane (THM) formation in raw and treated water were measured in a laboratory, and a chlorine decay and THM model was derived on the basis of these data. Simulated chlorine and THM profiles agree well with the measured values available. Various applications of this modelling approach are also briefly discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The decay of chlorine in drinking water involves a complex set of reactions that is usually simplified to first order kinetics in models of water quality in distribution systems. However, to be useful in optimising chlorine dosing regimes, the kinetics expression should accurately describe the shape of the chlorine decay curve for different chlorine doses and be able to simulate re-chlorination. After considering the nature of the reactions involved in chlorine decay, five simplified reaction schemes were evaluated for their suitability to describe chlorine concentration in bulk water. Each scheme was fitted to a sample of experimental data of chlorine decay in raw water obtained from Warragamba Dam (the major source of water supplied to Sydney, Australia). A scheme involving two parallel reactions of organic carbon compounds with chlorine is both necessary and sufficient to satisfy the requirements of modelling chlorine decay accurately.