999 resultados para WET STORAGE
Resumo:
This work was focused on studies of the metal hydride materials having a potential in building hydrogen storage systems with high gravimetric and volumetric efficiencies of H storage and formed / decomposed with high rates of hydrogen exchange. In situ diffraction studies of the metal-hydrogen systems were explored as a valuable tool in probing both the mechanism of the phase-structural transformations and their kinetics. Two complementary techniques, namely Neutron Powder Diffraction (NPD) and Synchrotron X-ray diffraction (SR XRD) were utilised. High pressure in situ NPD studies were performed at D2 pressures reaching 1000 bar at the D1B diffractometer accommodated at Institute Laue Langevin, Grenoble. The data of the time resolved in situ SR XRD were collected at the Swiss Norwegian Beam Lines, ESRF, Grenoble in the pressure range up to 50 bar H2 at temperatures 20-400°C. The systems studied by NPD at high pressures included deuterated Al-modified Laves-type C15 ZrFe2-xAlx intermetallics with x = 0.02; 0.04 and 0.20 and the CeNi5-D2 system. D content, hysteresis of H uptake and release, unit cell expansion and stability of the hydrides systematically change with Al content. Deuteration exhibited a very fast kinetics; it resulted in increase of the unit cells volumes reaching 23.5 % for ZrFe1.98Al0.02D2.9(1) and associated with exclusive occupancy of the Zr2(Fe,Al)2 tetrahedra. For CeNi5 deuteration yielded a hexahydride CeNi5D6.2 (20°C, 776 bar D2) and was accompanied by a nearly isotropic volume expansion reaching 30.1% (∆a/a=10.0%; ∆c/c=7.5%). Deuterium atoms fill three different interstitial sites including Ce2Ni2, Ce2Ni3 and Ni4. Significant hysteresis was observed on the first absorption-desorption cycle. This hysteresis decreased on the absorption-desorption cycling. A different approach to the development of H storage systems is based on the hydrides of light elements, first of all the Mg-based ones. These systems were studied by SR XRD. Reactive ball milling in hydrogen (HRBM) allowed synthesis of the nanostructured Mg-based hydrides. The experimental parameters (PH2, T, energy of milling, ball / sample ratio and balls size), significantly influence rate of hydrogenation. The studies confirmed (a) a completeness of hydrogenation of Mg into MgH2; (b) indicated a partial transformation of the originally formed -MgH2 into a metastable -MgH2 (a ratio / was 3/1); (c) yielded the crystallite size for the main hydrogenation product, -MgH2, as close to 10 nm. Influence of the additives to Mg on the structure and hydrogen absorption/desorption properties and cycle behaviour of the composites was established and will be discussed in the paper.
Resumo:
Background Despite guideline recommendations, there are no published randomised controlled trial data on the efficacy of antibiotics for chronic wet cough in children. The majority of children with chronic wet cough have protracted bacterial bronchitis (PBB), a recognised condition in multiple national guidelines. The authors conducted a parallel 1:1 placebo randomised controlled trial to test the hypothesis that a 2-week course of amoxycillin clavulanate is efficacious in the treatment of children with chronic wet cough. Methods 50 children (median age 1.9 years, IQR 0.9–5.1) with chronic (>3 weeks) wet cough were randomised to 2 weeks of twice daily oral amoxycillin clavulanate (22.5 mg/kg/dose) or placebo. The primary outcome was ‘cough resolution’ defined as a >75% reduction in the validated verbal category descriptive cough score within 14 days of treatment compared with baseline scores, or cessation of cough for >3 days. In selected children, flexible bronchoscopy and bronchoalveolar lavage (BAL) were undertaken at baseline. Results Cough resolution rates (48%) were significantly higher in children who received amoxycillin clavulanate compared with those who received placebo (16%), p=0.016. The observed difference between proportions was 0.32 (95% CI 0.08 to 0.56). Post treatment, median verbal category descriptive score in the amoxycillin clavulanate group of 0.5 (IQR 0.0–2.0) was significantly lower than in the placebo group, 2.25 (IQR 1.15–2.9) (p=0.02). Pre-treatment BAL data were consistent with PBB in the majority of children, with no significant difference between groups. Conclusion A 2-week course of amoxycillin clavulanate will achieve cough resolution in a significant number of children with chronic wet cough. BAL data support the diagnosis of PBB in the majority of these children.
Resumo:
A statistical approach is used in the design of a battery-supercapacitor energy storage system for a wind farm. The design exploits the technical merits of the two energy storage mediums, in terms of the differences in their specific power and energy densities, and their ability to accommodate different rates of change in the charging/discharging powers. By treating the input wind power as random and using a proposed coordinated power flows control strategy for the battery and the supercapacitor, the approach evaluates the energy storage capacities, the corresponding expected life cycle cost/year of the storage mediums, and the expected cost/year of unmet power dispatch. A computational procedure is then developed for the design of a least-cost/year hybrid energy storage system to realize wind power dispatch at a specified confidence level.
Resumo:
This paper presents the modeling and position-sensorless vector control of a dual-airgap axial flux permanent magnet (AFPM) machine optimized for use in flywheel energy storage system (FESS) applications. The proposed AFPM machine has two sets of three-phase stator windings but requires only a single power converter to control both the electromagnetic torque and the axial levitation force. The proper controllability of the latter is crucial as it can be utilized to minimize the vertical bearing stress to improve the efficiency of the FESS. The method for controlling both the speed and axial displacement of the machine is discussed. An inherent speed sensorless observer is also proposed for speed estimation. The proposed observer eliminates the rotary encoder, which in turn reduces the overall weight and cost of the system while improving its reliability. The effectiveness of the proposed control scheme has been verified by simulations and experiments on a prototype machine.
Resumo:
In this paper, a wind energy conversion system interfaced to the grid using a dual inverter is proposed. One of the two inverters in the dual inverter is connected to the rectified output of the wind generator while the other is directly connected to a battery energy storage system (BESS). This approach eliminates the need for an additional dc-dc converter and thus reduces power losses, cost, and complexity. The main issue with this scheme is uncorrelated dynamic changes in dc-link voltages that results in unevenly distributed space vectors. A detailed analysis on the effects of these variations is presented in this paper. Furthermore, a modified modulation technique is proposed to produce undistorted currents even in the presence of unevenly distributed and dynamically changing space vectors. An analysis on the battery charging/discharging process and maximum power point tracking of the wind turbine generator is also presented. Simulation and experimental results are presented to verify the efficacy of the proposed modulation technique and battery charging/discharging process.
Resumo:
The Wet Tropics region has a unique water asset and is also considered a priority region for the improvement of water quality entering the Great Barrier Reef due to a combination of high rainfall, intensive agricultural use, urban areas and the proximity of valuable reef assets to the coast. Agricultural activities are one of many identified threats to water quality and water flows in the Wet Tropics in terms of sediment and pollutant-related water quality decline. Information describing the current state of agricultural management practices across the region is patchy at best. Based on the best available information on agricultural management practices in the Wet Tropics in 2008, it is clear that opportunities exist to improve nutrient, sediment and pesticide management practice to reduce the impact on the water asset and the Great Barrier Reef. Based on current understandings of practices and the relationship between practices and reef water quality, the greatest opportunities for improved water quality are as follows: · nutrients – correct rate and the placement of fertilisers; · pesticides – improve weed control planning, herbicide rates and calibration practice; and · soil and sediment – implement new farming system practices. The 2008-09 Reef Rescue program sought to accelerate the rate of adoption of improved management practices and through Terrain invested $6.8M in the 2008-09 year for: · landholder water quality improvement incentive payments; · cross regional catchment repair of wetlands and riparian lands in areas of high sediment or nutrient loss; and · partnerships in the region to lever resources and support for on-ground practice change. The program delivered $3,021,999 in onground incentives to landholders in the Wet Tropics to improve farm practices from D or C level to B or A level. The landholder Water Quality Incentives Grants program received 300 individual applications for funding and funded 143 individual landholders to implement practice change across 36,098 ha of farm land. It is estimated that the Reef Rescue program facilitated practice change across 21% of the cane industry, and 20% of the banana industry. The program levered an additional $2,441,166 in landholder cash contributions and a further $907,653 in non-cash in-kind contributions bringing the total project value of the landholder grants program in the Wet Tropics to $6,370,819. Most funded projects targeted multiple water quality objectives with a focus on nutrient and sediment reduction. Of the 143 projects funded, 115 projects addressed nutrient management either as the primary focus or in combination with strategies that targeted other water quality objectives. Overall, 82 projects addressed two or more water quality targets. Forty-five percent of incentive funds were allocated to new farming system practices (direct drill legumes, zonal tillage equipment, permanent beds, min till planting equipment, GPS units, laser levelling), followed by 24% allocated to subsurface fertiliser applicators (subsurface application of fertiliser using a stool splitter or beside the stool, at the correct Six Easy Steps rate). As a result, Terrain estimates that the incentive grants achieved considerable reductions in nitrogen, phosphorus, sediment and pesticide loads. The program supported nutrient management training of 167 growers managing farms covering over 20% of the area harvested in 2008, and 18 industry advisors and resellers. This resulted in 115 growers (155 farms) developing nutrient management plans. The program also supported Integrated Weed Management training of 80 growers managing farms covering 8% of the area harvested in 2008, and 6 industry advisors and resellers. This report, which draws on the best available Reef Rescue Management Monitoring, Evaluation, Reporting, and Improvement (MERI) information to evaluate program performance and impact on water quality outcomes, is the first in a series of annual reports that will assess and evaluate the impact of the Reef Rescue program on agricultural practices and water quality outcomes. The assessment is predominantly focused on the cane industry because of data availability. In the next stage, efforts will expand to: · improve practice data for the banana and grazing industry; · gain a better understanding of the water quality trends and the factors influencing them in the Wet Tropics; in particular work will focus on linking the results of the Paddock to Reef monitoring program and practice change data to assess program impact; · enhance estimations of the impact of practice change on pollutant loads from agricultural land use; · gain a better understanding of the extent of ancillary practice (change not directly funded) resulting from Reef Rescue training/ education/communication programs; and · provide a better understanding of the economic cost of practice change across the Wet Tropics region. From an ecological perspective, water quality trends and the factors that may be contributing to change, require further investigation. There is a critical need to work towards an enhanced understanding of the link between catchment land management practice change and reef water quality, so that reduced nutrient, sediment, and pesticide discharge to the Great Barrier Reef can be quantified. This will also assist with future prioritisation of grants money to agricultural industries, catchments and sub catchments. From a social perspective, the program has delivered significant water quality benefits from landholder education and training. It is believed that these activities are giving landholders the information and tools to implement further lasting change in their production systems and in doing so, creating a change in attitude that is supportive and inclusive of Natural Resource Management (NRM). The program in the Wet Tropics has also considerably strengthened institutional partnerships for NRM, particularly between NRM and industry and extension organisations. As a result of the Reef Rescue program, all institutions are actively working together to collectively improve water quality. The Reef Rescue program is improving water quality entering the Great Barrier Reef Lagoon by catalysing substantial activity in the Wet Tropics region to improve land management practices and reduce the water quality impact of agricultural landscapes. The solid institutional partnerships between the regional body, industry, catchment and government organisations have been fundamental to the successful delivery of the landholder grant and catchment rehabilitation programs. Landholders have generally had a positive perception and reaction to the program, its intent, and the practical, focused nature of grant-based support. Demand in the program was extremely high in 2008-09 and is expected to increase in 2009-2010.
Resumo:
Design of a battery energy storage system (BESS) in a buffer scheme is examined for the purpose of attenuating the effects of unsteady input power from wind farms. The design problem is formulated as maximization of an objective function that measures the economic benefit obtainable from the dispatched power from the wind farm against the cost of the BESS. Solution to the problem results in the determination of the capacity of the BESS to ensure constant dispatched power to the connected grid, while the voltage level across the dc-link of the buffer is kept within preset limits. A computational procedure to determine the BESS capacity and the evaluation of the dc voltage is shown. Illustrative examples using the proposed design method are included.
Resumo:
This paper examines a buffer scheme to mitigate the negative impacts of power-conditioned loads on network voltage and transient stabilities. The scheme is based on the use of battery energy-storage systems in the buffers. The storage systems ensure that protected loads downstream of the buffers can ride through upstream voltage sags and swells. Also, by controlling the buffers to operate in either constant impedance or constant power modes, power is absorbed or injected by the storage systems. The scheme thereby regulates the rotor-angle deviations of generators and enhances network transient stability. A computational method is described in which the capacity of the storage systems is determined to achieve simultaneously the above dual objectives of load ride-through and stability enhancement. The efficacy of the resulting scheme is demonstrated through numerical examples.
Resumo:
Hailstones in wet growth are commonly found in thunderclouds. While the ice-ice relative growth rate mechanism is generally accepted as the most likely cause of thunderstorm electrification, it is uncertain if this mechanism will operate under wet growth conditions because ice crystals are more likely to stick to the wet surface of a hailstone rather than bounce off it. Experiments were carried out in the laboratory to investigate if there was any charge separated when vapor-grown ice crystals bounced off a wet hailstone. A cloud of supercooled droplets, with and without ice crystals, was drawn past a simulated hailstone. In the dry growth regime, the hailstone charged strongly positive when droplets and crystals co-existed in the cloud. With only droplets in the cloud, there was no charging in the dry growth regime. However, as the hailstone attained wet growth, positive charging currents of about 0.5 and 3.5 pA were observed at 12 and 20 m s-1, respectively. We hypothesize that this observed charging was due to the evaporation of melt water. This so called Dinger-Gunn Effect is due to the ejection of negatively charged minute droplets produced by air bubbles bursting at the surface of the melt water. However the charge separated in wet growth was an order of magnitude smaller than that in dry growth and, therefore, we conclude that it is unlikely to play an important role in the electrification of thunderstorms.
Resumo:
A novel replaceable, modularized energy storage system with wireless interface is proposed for a battery operated electric vehicle (EV). The operation of the proposed system is explained and analyzed with an equivalent circuit and an averaged state-space model. A non-linear feedback linearization based controller is developed and implemented to regulate the DC link voltage by modulating the phase shift ratio. The working and control of the proposed system is verified through simulation and some preliminary results are presented.
Resumo:
Battery-supercapacitor hybrid energy storage systems are becoming popular in the renewable energy sector due to their improved power and energy performances. These hybrid systems require separate dc-dc converters, or at least one dc-dc converter for the supercapacitor bank, to connect them to the dc-link of the grid interfacing inverter. These additional dc-dc converters increase power losses, complexity and cost. Therefore, possibility of their direct connection is investigated in this paper. The inverter system used in this study is formed by cascading two 3-level inverters, named as the “main inverter” and the “auxiliary inverter”, through a coupling transformer. In the test system the main inverter is connected with the rectified output of a wind generator while the auxiliary inverter is directly attached to a battery and a supercapacitor bank. The major issues with this approach are the dynamic changes in dc-link voltages and inevitable imbalances in the auxiliary inverter voltages, which results in unevenly distributed space vectors. A modified SVM technique is proposed to solve this issue. A PWM based time sharing method is proposed for power sharing between the battery and the supercapacitor. Simulation results are presented to verify the efficacy of the proposed modulation and control techniques.
Resumo:
A hybrid energy storage system (HESS) consisting of battery and supercapacitor (SC) is proposed for use in a wind farm in order to achieve power dispatchability. In the designed scheme, the rate of charging/discharging powers of the battery is controlled while the faster wind power transients are diverted to the SC. This enhances the lifetime of the battery. Furthermore, by taking into consideration the random nature of the wind power, a statistical design method is developed to determine the capacities of the HESS needed to achieve specified confidence level in the power dispatch. The proposed approach is useful in the planning of the wind farm-HESS scheme and the coordination of the power flows between the battery and SC.
Resumo:
The close relationship between rain and lightning is well known. However, there are numerous documented observations of heavy rain accompanied by little or no lightning activity (Williams et al, 1992; Jayaratne, 1993). Kuleshov et al (2002) studied thunderstorm distribution and frequency in Australia and concluded that thunderstorm frequency (as expressed by number of thunder-days) in Australia does not, in general, appear to vary in any consistent way with rainfall. However, thunder-days describe occurrence of thunderstorms as heard by an observer, and therefore could be only proxy data to evaluate actual lightning activity (i.e. number of total or cloud-to-ground flashes). Field experiments have demonstrated a strong increase in lightning activity with convective available potential energy (CAPE). It has also been shown that CAPE increases linearly with potential wet bulb temperature, Tw (Williams et al, 1992). In this study, we examine the relationship between lightning ground flash incidence and the two parameters – surface rainfall and surface wet bulb maximum temperature for selected localities around Australia...
Resumo:
Additional converters that are used to interface energy storage devices incur power losses as well as increased system cost and complexity. The need for additional converters can be eliminated if the grid side inverter can itself be effectively used as the interface for energy storage. This paper therefore proposes a technique whereby the grid side inverter can also be used as an interface to connect a supercapacitor energy storage for wind energy conversion systems. The proposed grid side inverter is formed by cascading a 3-level inverter and a 2-level inverter through a coupling transformer. The three-level inverter is the main inverter and it is powered by the rectified output of the wind turbine coupled AC generator while the 2-level auxiliary inverter is connected to the super capacitor bank that is used to compensate short term power fluctuations. Novel modulation and control techniques are proposed to address the problems associated with non-integer and dynamically-changing dc-link voltage ratio, which is caused by the random nature of wind. Simulation results are presented to verify the efficacy of the proposed system in suppressing short term wind power fluctuations.