721 resultados para Users satisfaction
Resumo:
Several companies are trying to improve their operation efficiency by implementing an enterprise resource planning (ERP) system that makes it possible to control the resources of the company in real time. However, the success of the implementation project is not a foregone conclusion; a significant part of these projects end in a failure, one way or another. Therefore it is important to investigate ERP system implementation more closely in order to increase understanding about factors influencing ERP system success and to improve the probability of a successful ERP implementation project. Consequently, this study was initiated because a manufacturing case company wanted to review the success of their ERP implementation project. To be exact, the case company hoped to gain both information about the success of the project and insight for future implementation improvement. This study investigated ERP success specifically by examining factors that influence ERP key-user satisfaction. User satisfaction is one of the most commonly applied indicators of information system success. The research data was mainly collected by conducting theme interviews. The subjects of the interviews were six key-users of the newly implemented ERP system. The interviewees were closely involved in the implementation project. Furthermore, they act as representative users that utilize the new system in everyday business processes. The collected data was analyzed by thematizing. Both data collection and analysis were guided by a theoretical frame of reference. This frame was based on previous research on the subject. The results of the study aligned with the theoretical framework to large extent. The four principal factors influencing key-user satisfaction were change management, contractor service, key-user’s system knowledge and characteristics of the ERP product itself. One of the most significant contributions of the research is that it confirmed the existence of a connection between change management and ERP key-user satisfaction. Furthermore, it discovered two new sub-factors influencing contractor service related key-user satisfaction. In addition, the research findings indicated that in order to improve the current level of key-user satisfaction, the case company should pay special attention to system functionality improvement and enhancement of the key-users’ knowledge. During similar implementation projects in the future, it would be important to assure the success of change management and contractor service related processes.
Resumo:
To compare variations in bone mineral density (BMD) and body composition (BC) in depot-medroxyprogesterone acetate (DMPA) users and nonusers after providing counselling on healthy lifestyle habits. An exploratory study in which women aged 18 to 40 years participated: 29 new DMPA users and 25 new non-hormonal contraceptive users. All participants were advised on healthy lifestyle habits: sun exposure, walking and calcium intake. BMD and BC were assessed at baseline and 12 months later. Statistical analysis included the Mann-Whitney test or Student's t-test followed by multiple linear regression analysis. Compared to the controls, DMPA users had lower BMD at vertebrae L1 and L4 after 12 months of use. They also had a mean increase of 2 kg in total fat mass and an increase of 2.2% in body fat compared to the non-hormonal contraceptive users. BMD loss at L1 was less pronounced in DMPA users with a calcium intake ≥ 1 g/day compared to DMPA users with a lower calcium intake. DMPA use was apparently associated with lower BMD and an increase in fat mass at 12 months of use. Calcium intake ≥ 1 g/day attenuates BMD loss in DMPA users. Counselling on healthy lifestyle habits failed to achieve its aims.
Resumo:
To identify the adherence rate of a statin treatment and possible related factors in female users from the Unified Health System. Seventy-one women were evaluated (64.2 ± 11.0 years) regarding the socio-economic level, comorbidities, current medications, level of physical activity, self-report of muscular pain, adherence to the medical prescription, body composition and biochemical profile. The data were analyzed as frequencies, Chi-Squared test, and Mann Whitney test (p<0.05). 15.5% of women did not adhere to the medical prescription for the statin treatment, whose had less comorbidities (p=0.01), consumed less quantities of medications (p=0.00), and tended to be younger (p=0.06). Those patients also presented higher values of lipid profile (CT: p=0.01; LDL-c: p=0.02). Musculoskeletal complains were not associated to the adherence rate to the medication. The associated factors to adherence of dyslipidemic women to statin medical prescription were age, quantity of comorbidities and quantity of current medication.
Resumo:
This article seeks to investigate associations between satisfaction with life and sociodemographic variables, health conditions, functionality, social involvement and social support among elderly caregivers and non-caregivers, as well as between satisfaction and the intensity of stress in the caregiver group. A sample of 338 caregivers was selected according to two items of the Brazilian version of the Elders Life Stress Inventory. A comparison-group of elderly non-caregivers was selected at random, with a similar gender, age and income profile. Data were derived from self-reported questionnaires and scales. Elderly caregivers with low levels of satisfaction and high levels of stress revealed more symptoms of insomnia, fatigue, diseases and worse IADL performance. Those with greater satisfaction and less stress revealed a good level of social support. Insomnia, depression and fatigue were associated with low satisfaction among caregivers, and with fatigue, depression and low social support among non-caregivers. It was considered relevant that instrumental, psychological and informative support can improve the quality of life and the quality of care provided by elderly caregivers, especially if they are affected by unfavorable health and psychosocial conditions and low satisfaction with life.
Resumo:
Data on record regarding weight variation in depot-medroxyprogesterone acetate (DMPA) and levonorgestrel-releasing intrauterine system (LNG-IUS) users are controversial. To date, no studies have yet evaluated weight variation in DMPA and LNG-IUS users in up to ten years of use compared to non-hormonal contraceptive users. A retrospective study analysed weight variations in 2138 women using uninterruptedly DMPA (150 mg intramuscularly, three-monthly; n = 714), the LNG-IUS (n = 701) or a copper-intrauterine device (Cu-IUD; n = 723). At the end of the first year of use, there was a mean weight increase of 1.3 kg, 0.7 kg and 0.2 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively, compared to weight at baseline (p < 0.0001). After ten years of use, the mean weight had risen by 6.6 kg, 4.0 and 4.9 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively. DMPA-users had gained more weight than LNG-IUS- (p = 0.0197) and than Cu-IUD users (p = 0.0294), with the latter two groups not differing significantly from each other in this respect (p = 0.5532). Users of hormonal and non-hormonal contraceptive methods gained a significant amount of weight over the years. DMPA users gained more weight over the treatment period of up to ten years than women fitted with either a LNG-IUS or a Cu-IUD.
Resumo:
Objective To assess the prevalence of insulin resistance (IR) and associated factors in contraceptive users. Methods A total of 47 women 18 to 40 years of age with a body mass index (kg/m(2)) < 30, fasting glucose levels < 100 mg/dl and 2-hour glucose level < 140 mg/dl after a 75-g oral glucose load were submitted to a hyperinsulinemic-euglycemic clamp. The women were distributed in tertiles regarding M-values. The analysed variables were use of combined hormonal/non-hormonal contraception, duration of use, body composition, lipid profile, glucose levels and blood pressure. Results IR was detected in 19% of the participants. The women with low M-values presented significantly higher body fat mass, waist-to-hip ratio, fasting insulin, HOMA-IR and were nulligravida, showed > 1 year of contraceptive use and higher triglyceride levels. IR was more frequent among combined oral contraceptive users, however no association was observed after regression analysis. Conclusions The prevalence of IR was high among healthy women attending a family planning clinic independent of the contraceptive method used with possible long-term negative consequences regarding their metabolic and cardiovascular health. Although an association between hormonal contraception and IR could not be found this needs further research. Family planning professionals should be proactive counselling healthy women about the importance of healthy habits.
Resumo:
The objectives were to identify factors associated with decreased life satisfaction in community-dwelling elderly and describe such factors according to gender and age bracket. The study interviewed 2,472 elderly individuals 65 years or older without cognitive deficits suggestive of dementia, in probabilistic samples from seven Brazilian cities. All measures were self-reported except for functional performance, indicated by handgrip and gait speed. Women had more chronic diseases, worse functional performance, and greater social involvement when compared to men. The oldest participants showed worse functional performance and less social involvement when compared to the youngest. Low satisfaction was associated with three or more diseases, memory problems, low social involvement, low handgrip strength, and urinary incontinence. The authors conclude that health, functional performance, and social involvement interact with well-being, so interventions targeting these areas can favor quality of life for the elderly.
Resumo:
Purpose: This study aimed to evaluate the assistance quality through the perception of the users and municipal health managers (mayors, health secretaries and screening team). Methods: A transversal and descriptive study was carried out. Results: The sample was comprised by 359 users and 48 managers. Medical assistance was considered excellent by 79.6% of the users, 93.7% of the managers, 87.5% of the health secretaries and 100% of the screening team. Reception received a great evaluation by 73.8% of the users and 93.8% of the selectors. Conclusion: The assistance model used at the Ophthalmologic Clinic of Divinolândia obtained a high level of satisfaction pleasing both users and managers.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
O consentimento do paciente antes do início de qualquer procedimento é uma condição a ser respeitada pelos profissionais da odontologia, sem nenhuma exceção. É necessário que o paciente esteja ciente de seu status de saúde, de suas necessidades específicas, do propósito de cada tratamento, conheça os planejamentos alternativos (incluindo o não tratamento), saiba do seu prognóstico, riscos, consequências, limitações e se conscientize das suas responsabilidades e as do seu cirurgião-dentista, proporcionando o sucesso do tratamento. O termo de consentimento livre e esclarecido (TCLE) visa fortalecer e esclarecer a posição do paciente, estabelecendo os direitos e deveres de ambas as partes paciente e profissional. O conhecimento integral do tratamento diminuirá a ansiedade do paciente e as complicações de tratamento, promoverá maior qualidade dos serviços odontológicos e maior satisfação do dentista e do paciente. Entretanto, no Brasil, poucos artigos são encontrados e existem alguns problemas éticos envolvendo as clínicas odontológicas, no que diz respeito a este documento de esclarecimento para o paciente. Diante disso, este trabalho tem por objetivo realizar uma revisão crítica sobre o tema abordado, demonstrando a importância do TCLE na clínica odontológica brasileira e na vida profissional dos cirurgiões-dentistas.
Resumo:
Two experiments evaluated an operant procedure for establishing stimulus control using auditory and electrical stimuli as a baseline for measuring the electrical current threshold of electrodes implanted in the cochlea. Twenty-one prelingually deaf children, users of cochlear implants, learned a Go/No Go auditory discrimination task (i.e., pressing a button in the presence of the stimulus but not in its absence). When the simple discrimination baseline became stable, the electrical current was manipulated in descending and ascending series according to an adapted staircase method. Thresholds were determined for three electrodes, one in each location in the cochlea (basal, medial, and apical). Stimulus control was maintained within a certain range of decreasing electrical current but was eventually disrupted. Increasing the current recovered stimulus control, thus allowing the determination of a range of electrical currents that could be defined as the threshold. The present study demonstrated the feasibility of the operant procedure combined with a psychophysical method for threshold assessment, thus contributing to the routine fitting and maintenance of cochlear implants within the limitations of a hospital setting.
Resumo:
Com o objetivo de comparar a satisfação das mulheres com a experiência do parto em três modelos assistenciais, foi realizada pesquisa descritiva, com abordagem quantitativa, em dois hospitais públicos de São Paulo, um promovendo o modelo "Típico" e o outro com um centro de parto intra-hospitalar (modelo "CPNIH") e um peri-hospitalar (modelo "CPNPH"). A amostra foi constituída por 90 puérperas, 30 de cada modelo. A comparação entre os resultados referentes à satisfação das mulheres com o atendimento prestado pelos profissionais de saúde, com a qualidade da assistência e os motivos de satisfação e insatisfação, com a indicação ou recomendação dos serviços recebidos, com a sensação de segurança no processo e com as sugestões de melhorias, mostrou que o modelo CPHPH foi o melhor avaliado, vindo em seguida o CPNIH e por último o Típico. Conclui-se que o modelo peri-hospitalar de assistência ao parto deveria receber maior apoio do SUS, por se constituir em serviço em que as mulheres se mostram satisfeitas com a atenção recebida
Resumo:
The present study sought to identify the perception of a given group of users of the Brazilian Public Health System (Sistema Unico de Saude) regarding organ donation and to implement an educational policy. Structured interviews were conducted with the aim of describing the profile of donor and nondonor subjects, the importance of organ donation, and the knowledge regarding donation and brain death. One hundred subjects were interviewed: 33% of them considered themselves potential donors; 40% were donors; 13% were nondonors; and 14% were ill-informed potential donors. However, only 40% of users have already officially expressed to their families a willingness to donate. Regarding their knowledge about the propitious moment for organ donation, only 64% of them associated the donation act with brain death. Although the present results revealed that users of the Brazilian Public Health System are prone to organ donation, there actually was a high amount of refusals, which may be due to lack of information and knowledge regarding the donation-transplantation process.
Resumo:
This paper analyzes the production of apartment buildings for the middle-income segment in the city of So Paulo, Brazil, from a historical perspective. Tracing the response to the occupants` needs, the focus is on family profiles and their demands, the relationship between architectural design and marketing, and satisfaction levels of current users. The paper begins with a brief historical overview of how apartment buildings have evolved over the past eight decades, highlighting the consolidation of the tripartite model. Next, it analyzes family profiles and their current needs, which would call for a redesign of domestic space. From a different angle, it shows how the real-estate market reacts to this situation, namely by introducing minor changes in the domestic space that are closely linked to major investments in marketing. This leads to a discussion on the quality of recent architectural designs in light of Post-Occupancy Evaluation (POE) case studies, which corroborate the tendencies previously outlined. The conclusions drawn from the POEs suggest that the market should establish a closer and deeper relationship between the assessment of the human behavior in the domestic space and the architectural quality of homes as a means of increasing satisfaction levels and improving design performance.
Resumo:
NUNES ALVES, M. J. N., M. R. DOS SANTOS, R. G. DIAS, C. A. AKIHO, M. C. LATERZA, M. U. P. B. RONDON, R. L. DE MORAES MOREAU, and C. E. NEGRAO. Abnormal Neurovascular Control in Anabolic Androgenic Steroids Users. Med. Sci. Sports Exerc., Vol. 42, No. 5, pp. 865-871, 2010. Purpose: Previous studies showed that anabolic androgenic steroids (AAS) increase vascular resistance and blood pressure (BP) in humans. In this study, we tested the hypotheses 1) that AAS users would have increased muscle sympathetic nerve activity (MSNA) and reduced forearm blood flow (FBF) compared with AAS nonusers and 2) that there would be an association between MSNA and 24-h BP. Methods: Twelve AAS users aged 31 +/- 2 yr (means +/- SE) and nine age-matched AAS nonusers aged 29 T 2 yr participated in the study. All individuals were involved in strength training for at least 2 yr. AAS was determined by urine test (chromatography-mass spectrometry). MSNA was directly measured by microneurography technique. FBF was measured by venous occlusion plethysmography. BP monitoring consisted of measures of BP for 24 h. Results: MSNA was significantly higher in AAS users than that in AAS nonusers (29 +/- 3 vs 20 +/- 1 bursts per minute, P = 0.01). FBF (1.92 +/- 0.17 vs 2.77 +/- 0.24 mL.min(-1).100 mL(-1), P = 0.01) and forearm vascular conductance (2.01 +/- 0.17 vs 2.86 +/- 0.31 U, P = 0.02) were significantly lower in AAS users than that in AAS nonusers. Systolic (131 +/- 4 vs 120 +/- 3 mm Hg, P = 0.001), diastolic (74 +/- 4 vs 68 +/- 3 mm Hg, P = 0.02), and mean BP (93 +/- 4 vs 86 +/- 3 mm Hg, P = 0.005) and heart rate (74 +/- 3 vs 68 +/- 3 bpm, P = 0.02) were significantly higher in AAS users when compared with AAS nonusers. Further analysis showed that there was a significant correlation between MSNA and 24-h mean BP (r = 0.75, P = 0.002). Conclusions: AAS increases MSNA and reduces muscle blood flow in young individuals. In addition, the increase in BP levels in AAS users is associated with augmented sympathetic outflow. These findings suggest that AAS increases the susceptibility for cardiovascular disease in humans.