164 resultados para Unbalance


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three-phase three-wire power flow algorithms, as any tool for power systems analysis, require reliable impedances and models in order to obtain accurate results. Kron's reduction procedure, which embeds neutral wire influence into phase wires, has shown good results when three-phase three-wire power flow algorithms based on current summation method were used. However, Kron's reduction can harm reliabilities of some algorithms whose iterative processes need loss calculation (power summation method). In this work, three three-phase three-wire power flow algorithms based on power summation method, will be compared with a three-phase four-wire approach based on backward-forward technique and current summation. Two four-wire unbalanced medium-voltage distribution networks will be analyzed and results will be presented and discussed. © 2004 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage profile in the network, decrease loss etc. but can create safety and technical problems as well, This work report the application of the instantaneous space phasors and the instantaneous complex power in observing performances of the distribution networks with dispersed generators in steady state. New IEEE apparent power definition, the so called Buccholz-Goodhue apparent power, as well as new proposed power quality (oscillation) index in the three-phase distribution systems with unbalanced loads and dispersed generators, are applied. Results obtained from several case studies using IEEE 34 nodes test network are presented and discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We often face Patients searching for rehabilitation for lower back disorders during the physiotherapeutic routine, and it is known that the abdominal muscle, specially the rectus abdominis muscle, aid the stabilization of the pelvis. Therefore, this paper analyzes the electrical activity of the rectus abdominis muscle in the pelvic retroversion in dorsal decubitus and in orthostatic position and in the lowering of the lower limbs. 30 healthy students, male and female, 17-40 yr, divided into two groups - Group 1: 15 volunteers (pelvic balance); Group 2 (pelvic unbalance) took part in this study. The electrical activity of the right and left supra-umbilical and infra-umbilical portions of the rectus abdominis muscle was detected. The mean RMS values from three attempts ftom the electromyographic traces were usedfor the analysis of the electrical activity. The RMS value was submitted to the normalization process. The data were submitted to statistic treatment by the Friedman test, and the analyses of the means and standard deviation towards a level of significance of 95%. The results demonstrated that the portions of the rectus abdominis muscle presented low electrical activity for the groups studiedfor pelvic retroversion either in dorsal decubitus or and orthostatic position. However, the decreasing movement of the lower limbs towards the portions of the rectus abdominis muscle presented more significant electrical activity whereas the lower portions presented higher activity than the higher ones for Group 2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the importance of the voltage referential for power quality monitoring and power systempsilas instrumentation. Considering the operating conditions of simple power circuits, it will be demonstrated that an incorrect choice of the voltages referential may result in erroneous quantification of some power quality indices, especially in three-phase four wire circuits. The use of a virtual reference point and the neutral conductor as reference have been considered and the simulation results confirm the influence of the voltage reference selection in the evaluation of total harmonic distortion, unbalance factors and voltage sags. Finally a way of linking both methods will be discussed by means of Blakesleypsilas theorem. © Copyright 2010 IEEE - All Rights Reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aimed to compare fertigation to conventional fertilization in a five-year-old 'Valência' orange orchard, irrigated by microsprinklers. The conventional fertilization, using the recommended dosage for the crop, was parceled out in three during the year. In the fertigation treatments a complete dose, 1/2 and 1/3 of the conventional fertilization dose, parceled out in ten in a year, were used. Trunk circumference and leaf volume, leaf chlorophyll content and fruit yield and quality were measured. For the first year, significant differences among the treatments for the evaluated parameters were not observed; however, it was noticed that fertigation treatments caused less nutritional unbalance, obtained by DRIS. The fertigation treatment using half dosage showed the best result regarding to fruit yield and quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The chronic kidney disease (CKD) it is characterized by irreversible structural lesions that can develop progressively for uremia and chronic renal failure (CRF). In the CRF it happens the incapacity of executing the functions of maintenance of the electrolyte balance and acid-base, catabolitos excretion and hormonal regulation appropriately. When the mechanism basic physiopathology of the renal upset is analyzed, it is observed that present factors, predispose to the unbalance oxidative. Most of the time, the renal patient comes badly nurtured, with lack in reservations of vitamins and minerals, what reduces the antioxidant defense mechanisms, what favors the installation of the renal oxidative stress, with the formation of species you reactivate of reactive oxygen species (ROS), substances these potentially harmful to the organism. The reduction of the glomerular filtration rate (GFR) in the evolution of CKD in dogs and cats is a component for the installation of the renal oxidative stress. The ROS possesses important action in the kidneys, and these substances are highly reactivate, and when presents in excess damage lipids, proteins, DNA and carbohydrate, driving functional and structural abnormalities taking the cellular apoptosis and necrosis. Against the harmful potential action of these substances you reactivate, she becomes fundamental a delicate control of his production and consumption in the half intracellular, in other words, a balance of his concentration intra and extracellular. That is possible due to the activity of the antioxidants. Like this, to present literature revision had as objective describes the participation of the oxidative stress in CRF, as well as the mechanisms defenses against the harmful action of those substances.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering the Conservative Power Theory (CPT), this paper proposes some novel compensation strategies for shunt passive or active devices. The CPT current decompositions result in several current terms, which are associated with specific physical phenomena (average power consumption P, energy storage Q, load and source distortion D, unbalances N). These current components were used in this work for the definition of different current compensators, which can be selective in terms of minimizing particular disturbing effects. Compensation strategies for single and three-phase four-wire circuits have also been considered. Simulation results have been demonstrated in order to validate the possibilities and performance of the proposed strategies. © 2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Smart micro-grids offer a new challenging domain for power theories and metering techniques, because they include a variety of intermittent power sources which positively impact on power flow and distribution losses, but may cause voltage asymmetry and frequency variation. Due to the limited power capability of smart micro-grids, the voltage distortion can also get worse (in case of supplying non-linear loads), affecting measurement accuracy and possibly causing tripping of protections. In such a context, a reconsideration of power theories is required, since they form the basis for supply and load characterization. A revision of revenue metering techniques is also needed, to ensure a correct penalization of the loads for their responsibility in generating reactive power, voltage unbalance and distortion. This paper shows that the Conservative Power Theory (CPT) provides a suitable background to cope with smart grids characterization and metering needs. Experimental results validate the proposed approach. © 2010 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Problems as voltage increase at the end of a feeder, demand supply unbalance in a fault condition, power quality decline, increase of power losses, and reduction of reliability levels may occur if Distributed Generators (DGs) are not properly allocated. For this reason, researchers have been employed several solution techniques to solve the problem of optimal allocation of DGs. This work is focused on the ancillary service of reactive power support provided by DGs. The main objective is to price this service by determining the costs in which a DG incurs when it loses sales opportunity of active power, i.e, by determining the Loss of Opportunity Costs (LOC). The LOC will be determined for different allocation alternatives of DGs as a result of a multi-objective optimization process, aiming the minimization of losses in the lines of the system and costs of active power generation from DGs, and the maximization of the static voltage stability margin of the system. The effectiveness of the proposed methodology in improving the goals outlined was demonstrated using the IEEE 34 bus distribution test feeder with two DGs cosidered to be allocated. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the study of the so called Generalized Symmetrical Components, proposed by Tenti et. al. to the analysis of unbalanced periodic non sinusoidal three phase systems. As a result, it was possible to establish a proper relationship between such of generalized symmetrical components and Fortescue symmetrical components to the harmonic frequencies that compose a generic periodic non sinusoidal three phase system. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a set of performance factors for load characterization and revenue metering. They are based on the Conservative Power Theory, and each of them relates to a specific load non-ideality (unbalance, reactivity, distortion). The performance factors are capable to characterize the load under different operating conditions, considering also the effect of non-negligible line impedances and supply voltage deterioration. © 2012 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Based on the framework of the Conservative Power Theory (CPT), this paper proposes some compensation strategies for shunt current compensators. CPT current decompositions result in several current-related terms associated with specific load characteristics, such as power consumption, energy storage, unbalances and load nonlinearities. These current components are decoupled (orthogonal) from each other and are used here to define different compensation strategies, which can be selective in minimizing particular effects of disturbing loads. Compensation strategies for single- and three-phase four-wire circuits are also considered. Simulated and experimental results are described to validate the possibilities and performance of the proposed strategies. © 2013 Brazilian Society for Automatics - SBA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)