924 resultados para Tricuspid valve
Resumo:
Patients who develop a severe stenosis in biological pulmonary conduits previously implanted for pulmonary outflow trunk reconstructions are treated either by surgical re-replacement, or by transcatheter stent-valve implantation through a femoral vein access. A catheter-based sub-xyphoidian access through the right ventricle for stent-valve positioning in a pulmonary conduit has rarely been proposed. We describe the case of a 20-year-old man who underwent a pulmonary trunk reconstruction for a congenital pulmonary valve dysplasia and a few years later developed a stenosis in the pulmonary conduit. He was successfully treated with a 23 mm Edwards Sapien stent-valve implantation in pulmonary position, through an unusual right ventricular, sub-xyphoidian access and without contrast medium injections and pleura opening.
Resumo:
AIMS: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. METHODS AND RESULTS: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. CONCLUSION: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.
Resumo:
GOAL: To evaluate the impact of the Ross operation, recently (1997) introduced in our unit, for the treatment of patients with congenital aortic valve stenosis. METHODS: The period from January 1997 to December 2000 was compared with the previous 5 years (1992-96). Thirty-seven children (< 16 yrs) and 49 young adults (16-50 yrs) with congenital aortic valve stenosis underwent one of these treatments: percutaneous balloon dilatation (PBD), aortic valve commissurotomy, aortic valve replacement and the Ross operation. The Ross operation was performed in 16 patients, mean age 24.5 yrs (range 9-46 yrs) with a bicuspid stenotic aortic valve, 7/10 adults with calcifications, 2/10 adults with previous aortic valve commissurotomy, 4/6 children with aortic regurgitation following PBD, and 1/6 children who had had a previous aortic valve replacement with a prosthetic valve and aortic root enlargement. RESULTS: PBD was followed by death in two neonates (fibroelastosis); all other children survived PBD. Although there were no deaths, PBD in adults was recently abandoned, owing to unfavourable results. Aortic valve commissurotomy showed good results in children (no deaths). Aortic valve replacement, although associated with good results (no deaths), has been recently abandoned in children in favour of the Ross operation. Over a mean follow-up of 16 months (2-40 months) all patients are asymptomatic following Ross operation, with no echocardiographic evidence of aortic valve regurgitation in 10/16 patients and with trivial regurgitation in 6/16 patients. CONCLUSIONS: The approach now for children and young adults with congenital aortic valve stenosis should be as follows: (1) PBD is the first choice in neonates and infants; (2) Aortic valve commissurotomy is the first choice for children, neonates and infants after failed PBD; (3) The Ross operation is increasingly used in children after failed PBD and in young adults, even with a calcified aortic valve.
Resumo:
The trans-apical aortic valve implantation (TA-AVI) is an established technique for high-risk patients requiring aortic valve replacement. Traditionally, preoperative (computed tomography (CT) scan, coronary angiogram) and intra-operative imaging (fluoroscopy) for stent-valve positioning and implantation require contrast medium injections. To preserve the renal function in elderly patients suffering from chronic renal insufficiency, a fully echo-guided trans-catheter valve implantation seems to be a reasonable alternative. We report the first successful TA-AVI procedure performed solely under trans-oesophageal echocardiogram control, in the absence of contrast medium injections.
Transcatheter aortic valve implantation (TAVI): state of the art techniques and future perspectives.
Resumo:
Transcatheter aortic valve therapies are the newest established techniques for the treatment of high risk patients affected by severe symptomatic aortic valve stenosis. The transapical approach requires a left anterolateral mini-thoracotomy, whereas the transfemoral method requires an adequate peripheral vascular access and can be performed fully percutaneously. Alternatively, the trans-subclavian access has been recently proposed as a third promising approach. Depending on the technique, the fine stent-valve positioning can be performed with or without contrast injections. The transapical echo-guided stent-valve implantation without angiography (the Lausanne technique) relies entirely on transoesophageal echocardiogramme imaging for the fine stent-valve positioning and it has been proved that this technique prevents the onset of postoperative contrast-related acute kidney failure. Recent published reports have shown good hospital outcomes and short-term results after transcatheter aortic valve implantation, but there are no proven advantages in using the transfemoral or the transapical technique. In particular, the transapical series have a higher mean logistic Euroscore of 27-35%, a procedural success rate above 95% and a mean 30-day mortality between 7.5 and 17.5%, whereas the transfemoral results show a lower logistic Euroscore of 23-25.5%, a procedural success rate above 90% and a 30-day mortality of 7-10.8%. Nevertheless, further clinical trials and long-term results are mandatory to confirm this positive trend. Future perspectives in transcatheter aortic valve therapies would be the development of intravascular devices for the ablation of the diseased valve leaflets and the launch of new stent-valves with improved haemodynamic, different sizes and smaller delivery systems.
Resumo:
BACKGROUND: The impact of early valve surgery (EVS) on the outcome of Staphylococcus aureus (SA) prosthetic valve infective endocarditis (PVIE) is unresolved. The objective of this study was to evaluate the association between EVS, performed within the first 60 days of hospitalization, and outcome of SA PVIE within the International Collaboration on Endocarditis-Prospective Cohort Study. METHODS: Participants were enrolled between June 2000 and December 2006. Cox proportional hazards modeling that included surgery as a time-dependent covariate and propensity adjustment for likelihood to receive cardiac surgery was used to evaluate the impact of EVS and 1-year all-cause mortality on patients with definite left-sided S. aureus PVIE and no history of injection drug use. RESULTS: EVS was performed in 74 of the 168 (44.3%) patients. One-year mortality was significantly higher among patients with S. aureus PVIE than in patients with non-S. aureus PVIE (48.2% vs 32.9%; P = .003). Staphylococcus aureus PVIE patients who underwent EVS had a significantly lower 1-year mortality rate (33.8% vs 59.1%; P = .001). In multivariate, propensity-adjusted models, EVS was not associated with 1-year mortality (risk ratio, 0.67 [95% confidence interval, .39-1.15]; P = .15). CONCLUSIONS: In this prospective, multinational cohort of patients with S. aureus PVIE, EVS was not associated with reduced 1-year mortality. The decision to pursue EVS should be individualized for each patient, based upon infection-specific characteristics rather than solely upon the microbiology of the infection causing PVIE.
Resumo:
During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.
Resumo:
The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.
Resumo:
Introduction: La surcharge de pression ventriculaire augmente à l’exercice chez les patients avec une sténose de valve aortique (SVA). Lorsqu’il n’y a aucun symptôme apparent, il est cependant difficile d’indiquer l’intervention chirurgicale en utilisant seulement les indices de surcharge de pression ventriculaire. D’autres paramètres, tels que la dispersion de la repolarisation ventriculaire (d-QT), qui augmentent avec le gradient de pression transvalvulaire (GPT), n’ont pas été étudiés dans la SVA. L’objectif de l’étude était de déterminer le modèle de réponse du segment QT et de la d-QT à l’épreuve d’effort chez des enfants avec une SVA congénitale modérée afin d’évaluer l’impact de la surcharge de pression ventriculaire selon une perspective électrophysiologique. Matériel et méthodes: 15 patients SVA modérés ont été comparés à 15 sujets contrôles appariés pour l’âge (14.8±2.5 ans vs. 14.2±1.5 ans) et pour le sexe (66,7% de sujets mâles). Tous les sujets ont fait une épreuve d’effort avec enregistrement électrocardiographique à 12 dérivations. Le segment QT a été mesuré à partir du début du complexe QRS jusqu’à l’apex de l’onde T (QTa) au repos, à l’effort maximal ainsi qu’après 1 et 3 minutes de récupération. La longueur du segment QT a été corrigée selon l’équation de Fridericia et la d-QT a été calculée. Résultats: La longueur du segment QT corrigée (QTc) était similaire au repos entre les groupes d’étude, mais était significativement élevée chez les SVA en comparaison avec le groupe contrôle à l’effort maximal (p=0.004) ainsi qu’après 1 (p<0.001) et 3 (p<0.001) minutes de récupération. Une interaction significative a été identifiée entre les groupes pour la d-QT (p=0.034) et les tests post hoc ont révélé une différence significative seulement au repos (p=0.001). Conclusions: Les anomalies de repolarisation ventriculaire peuvent être révélées par l’évaluation de la repolarisation électrique lors de l’épreuve d’effort chez les SVA modérées asymptomatiques. L’utilisation de la réponse du QT à l’effort pourrait être bénéfique pour l’optimisation de la stratification du risque chez ces patients.
Resumo:
La sténose valvulaire aortique (SVA) est la maladie des valves cardiaques la plus répandue dans les pays développés qui touche les personnes âgées. La SVA est un processus actif caractérisé par des dépôts de lipides, de l’inflammation, de la fibrose et une calcification active des feuillets qui progresse vers un épaississement et durcissement de la valve aortique et une diminution de l’aire de la valve aortique. Nous avons émis l’hypothèse que la pathogénèse de la SVA modifie progressivement l’endothélium de la valve aortique, ce qui engendre l’expression de biomarqueurs spécifiques aux tissus et à la maladie. On rapporte dans cet étude, l’utilisation de la technique de sélection in vivo par phage display d’une librairie de peptides aléatoires afin de trouver de nouveaux peptides candidats qui se lieraient à des biomarqueurs spécifiques à la valve aortique malade d’une souris. Des souris ATX (LDLr-/-;Tg(hApoB+/+)) âgées atteintes de la SVA ont été utilisées pour la sélection in vivo d’une librairie de peptides aléatoires de 7 acides aminés contraints ou linéaires. Après 4 tours de criblage, on a caractérisé 14 phages différents qui ont été séparés en 5 motifs consensus pour la librairie linéaire et 11 phages différents qui représentent 5 différents motifs consensus pour la libraire de peptides contraints. La spécificité de 4 phages candidats de la librairie linéaire et de 5 phages de la librairie contrainte a été étudiée par l’immunomarquage des peptides d’intérêt exprimés par les phages sur les coupes de tissus de la valve aortique malade par rapport aux tissus contrôles du foie, du rein, de la rate, du ventricule et du poumon. Parmi eux, 6 phages représentent des peptides candidats intéressants qui ont besoin d’être testés davantage pour évaluer leur spécificité in vivo à la valve. Bien qu’il reste encore de la validation à effectuer, les peptides candidats spécifiques trouvés peuvent représenter des agents moléculaires d’imagerie utiles ou des transporteurs dans la livraison de drogue qui ciblent la valve aortique malade.
Resumo:
Contexte: La régurgitation mitrale (RM) est une maladie valvulaire nécessitant une intervention dans les cas les plus grave. Une réparation percutanée de la valve mitrale avec le dispositif MitraClip est un traitement sécuritaire et efficace pour les patients à haut risque chirurgical. Nous voulons évaluer les résultats cliniques et l'impact économique de cette thérapie par rapport à la gestion médicale des patients en insuffisance cardiaque avec insuffisance mitrale symptomatique. Méthodes: L'étude a été composée de deux phases; une étude d'observation de patients souffrant d'insuffisance cardiaque et de régurgitation mitrale traitée avec une thérapie médicale ou le MitraClip, et un modèle économique. Les résultats de l'étude observationnelle ont été utilisés pour estimer les paramètres du modèle de décision, qui a estimé les coûts et les avantages d'une cohorte hypothétique de patients atteints d'insuffisance cardiaque et insuffisance mitrale sévère traitée avec soit un traitement médical standard ou MitraClip. Résultats: La cohorte de patients traités avec le système MitraClip était appariée par score de propension à une population de patients atteints d'insuffisance cardiaque, et leurs résultats ont été comparés. Avec un suivi moyen de 22 mois, la mortalité était de 21% dans la cohorte MitraClip et de 42% dans la cohorte de gestion médicale (p = 0,007). Le modèle de décision a démontré que MitraClip augmente l'espérance de vie de 1,87 à 3,60 années et des années de vie pondérées par la qualité (QALY) de 1,13 à 2,76 ans. Le coût marginal était 52.500 $ dollars canadiens, correspondant à un rapport coût-efficacité différentiel (RCED) de 32,300.00 $ par QALY gagné. Les résultats étaient sensibles à l'avantage de survie. Conclusion: Dans cette cohorte de patients atteints d'insuffisance cardiaque symptomatique et d insuffisance mitrale significative, la thérapie avec le MitraClip est associée à une survie supérieure et est rentable par rapport au traitement médical.
Resumo:
The rotary valve is a widely used mechanical device in many solids-handling industrial processes. However, it may also be responsible for most of the attrition effects occurring in a typical process. In this study, the attrition effects occurring in a rotary valve operating as a stand-alone device and as part of a pneumatic conveying system were investigated. In the former case granular attrition was carried out at three different rotary valve speeds and the experimental results obtained were found to be in good agreement with the Gwyn correlation. In the latter case three typical air flow rates were used in the pneumatic conveying system. The size distribution of the attrition product obtained at the lowest air flow rate used was not adequately described by the Gwyn correlation. The attrition process and mechanisms involved were analysed and the minimum size of the attrition product obtained from both modes of operations was found to be similar.
Resumo:
A doença degenerativa mixomatosa da válvula mitral (DDMVM) é uma cardiopatia de alta incidência na clínica médica de pequenos animais, acometendo mormente cães idosos e raças de pequeno porte. Desta forma, foi realizada uma investigação científica objetivando avaliar clinicamente a utilização dos fármacos maleato de enalapril e furosemida em cães com a referida enfermidade na classe funcional Ib da ICC, antes e após a terapêutica implantada. Para isso, utilizaram-se 16 cães portadores da valvulopatia supracitada, distribuídos em dois grupos; com o primeiro recebendo furosemida (n=8) e o segundo maleato de enalapril (n=8), durante 56 dias. Os cães foram avaliados em quatro momentos (T0, T14, T28 e T56 dias) quanto aos sinais clínicos e parâmetros hematológicos e bioquímico-séricos, que incluíram concentrações séricas da enzima conversora da angiotensina (ECA) e aldosterona, como também avaliações radiográficas, eletrocardiográficas, ecodopplercardiográficas e da pressão arterial. Os resultados quanto aos parâmetros clínicos, avaliações hematológicas e bioquímicas séricas não revelaram alterações significativas em ambos os grupos, mas reduções significativas nos valores de ECA e aldosterona no grupo que recebeu o maleato de enalapril foram identificadas. Ao exame radiográfico observou-se reduções nos valores de VHS e na variável onda Pms do eletrocardiograma em ambos os grupos, mas sem alterações nos valores da pressão arterial. Por sua vez, o ecodopplercardiograma evidenciou diminuição significativa das variáveis DIVEd/s nos grupos estudados e na FEC% nos cães que receberam somente enalapril. Portanto, a análise dos resultados encontrados indicou que a monoterapia fundamentada no maleato de enalapril apresentou melhor eficiência no controle do quadro clínico em pacientes da classe funcional Ib da ICC.