956 resultados para Tratamento de esgotos sanitários


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The city of Natal comprises an area of about 170 km² (65,63 squares miles). The Dunas-Barreiras Aquifer is the most important reservoir of the coastal basin of RN. It is being responsible for the water supplying of about 70% of the population, however, due to the sewage disposal system by cesspools and drains, it is presently affected in a great extent by nitrates contamination. Thus, the present work proposes to research the utilization of contaminated water by nitrates of this fountainhead and find cost of the potable water through the ionic exchange technology. This technology consists in the removal of mineral salts by the exchange of cations for one ion of hydrogen (H+), through the passage of water by cationic resin bed and, secondly, by the exchange of the anions for hydroxyl ions (OH-) through a anionic resin bed. The obtained results have showed the waters derived from fountains, big water holes and shallow wells were microbiologically contaminated, while the waters derived from deep wells (above 70 m 76,58 yards) were free of contamination. Thus, only these ones are suitable to the use of ionic technology. The experiments were conducted with the resin IMAC-HP-555 such as kinetic, thermodynamic, and adsorption by fixed bed studies, being obtained several project variables for the experimental column, as follow: work temperature of 25oC; resin maximum capacity maximum e mean of adsorption ==0,01692 g NO3-1/g R e 0,0110 g NO3-1/g R, respectively. On the experimental column were performed breakthrough tests which pointed for an average ideal average speed of work of 13.2 m / h, with an average efficiency of 45% of adsorption, an optimal concentration of NaCl desorption of 8%, and an ideal desorption time of 80 minutes for the equilibrium conditions of water from the Dunas-Barreiras aquifer. Scale projection for ion-exchange column for denitrification, for these variables, using a computer modeling programme, to project the column of ion exchange ROREX-420/2000, obtained a cost for the drinking water denitrified by this system of R$ 0,16 / m3

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Because of disability in public policy development in mind to attend issues of sanitation in the municipalities, companies known as "clean-blue" appeared proposing to solve a simple collection and management of wastewater produced in single or multifamily residences, commercial, hospitals, etc. In the case of an activity in which there are no worries about the fate of sewage, emerged some doubts about the degree of health and environmental safety in these companies. Traditionally, most of them makes the provision of waste depleted soil or wetland, open, usually located on the outskirts of cities (MENESES, 2001). In turn, the sludge from septic tanks exhausted, provided no technical criteria - in the soil, rivers and as an agricultural fertilizer put in risk the health of the population and environmental quality. This work was entered in the search network 5 of the Notice of the Research Program in Sanitation - PROSAB-5, aimed to study the theme 'Characterization and study of alternative ways of treating sludge from septic tanks in the city of Natal, RN', proposing to evaluate the performance of the use of stabilization ponds as a system to handle waste from septic tanks exhausted. A series of lakes studied belong to one of the largest clean-pit of Natal, consisting of two anaerobic ponds, one facultative and maturation, and a tank disinfection, the wastewater being released in the Potengi River. Samples were collected between the months of October 2007 to October 2008, at six points previously defined and judged as more appropriate to what is proposed study. The analysis results in field and laboratory showed the most significant removal of COD (88.93%), total suspended solids (94.87%), organic nitrogen (66.87%) and thermotolerant coliforms (99.88%). Some results have not reached the expected because the system under study had operating problems that have undermined the efficiency of the reactors

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Only 32% of the population of Natal is attended by sewage, while the remaining population use pits and septic tanks. The characterization of the contents of septic tanks and pits contributes to the performance of such system and may guide the decision on treatment of these contents. The main of this research is to characterize the contents of interior residential pits and septic tanks in the greater Natal, with the following specific goals: to develop and manufacture a sampler capable of collecting a representative sample of the entire column (the surface scum, the clarified liquid and sludge bottom); to compare the contents of the tanks with the pits; to compare the contents of the septage from vacuum trucks; to relate the composition content with socioeconomic characteristics of households; to compare the content in both chambers of the septic tanks in series; to assess the situation of the content before and six months after the cleanness; and ultimately propose a pilot scale plant for treatment of septage. Once the sampler was developed, samples were collected within 14 septic tanks and 10 pits in many districts of Natal. Medians of the 24 systems were obtained: temperature, pH, conductivity, oil and grease, total solids, total suspended solids and sediments of 28.0 °C, 6.95; 882 mS/cm, 75.2 mg/L; 10,169 mg/L, 6,509 mg/L and 175 mL/L respectively; 111.0 mgN/L for ammonia, 130.5 mgN/ L for organic nitrogen, 0.2 mgN/L for nitrite, 0.4 mg/L for nitrate; 8935 mgO2/L for COD, 29.2 mgP/L for total phosphorus, thermotolerant coliforms from 9.95 E +06 CFU/100mL helminth eggs and 9.2 eggs/L with a maximum concentration of 688 eggs/L and minimum of 0 eggs/L. Medians of organic nitrogen and TKN were significantly different between groups of tanks and pits. The systems with cleanness gap from 11 and 20 years presented the higher concentrations for most variables. The effluent from the toilets and bathrooms participate more effectively in contributing fractions of solids, alkalinity, nitrogen, COD, total phosphorus, thermotolerant coliforms and helminth eggs. The systems used by socioeconomics class with income from R$ 3,700.00 to R$ 7,600.00, presented higher concentrations for COD, nitrogen, solids and helminth eggs. The first of the two chambers had always presented higher concentrations over the second compartment. The analysis of variance for most variables, showed that the values of septic tanks, pits and septage from vacuum trucks belong to the same group. In the samples taken after cleanness, the median of pH and temperature increased, while alkalinity, COD, organic nitrogen, total phosphorus, ammonia and helminth eggs decreased. The oils and greases and thermotolerant coliforms had slightly varied due to the continuous release of sewage into the systems that maintained their steady state concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil - FEIS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The actual work broaches a study about the collection and treatment of sanitary sewage from the municipality of Ubatuba in its operational aspects and the tariff policy from the service. Themes related to the subject like the history of collection and treatment of sewage, its development in Brazil and its importance for public health and environmental preservation, as well as historical and geographical aspects of Ubatuba/SP, are present in the literature review. The methodology consists in guided visit in the colletion and treatment of sewage facilities and interview with technical managers. With the technical data obtained, it is made a discussion of the results and possible recommendations

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water is an essential element for life. The use of this element, to support the community, defines it as water resource. This feature is being misused and degraded by the dumping of highly contaminated effluents. The impoverishment of its quality poses a risk to human consumption. The necessity to manage this resource, treating the wastewater properly, requires the constant improvement of treatment systems. Another need is to adjust the cost of systems to the demands of communities with less financial clout. This study aimed to adapt and understand the systems of wetlands, improving its efficiency, in an attempt to collaborate with the enrichment of this technology. The practical evidence, with lab-scale prototypes, assembled in ETE Piracicamirim with urban sewage effluent contributed to highlight the problems and operating system design. The bibliographic review showed that several studies had effectiveness for treatment. But it was evident the need for better understanding of dimensioning definitions that better attempted to the answers into the project. Moreover, standardization of system conditions for the specific wastewater treatment is an interesting field, identified, for future studies yet contribute to environmental engineering and sanitation

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this project is to verify whether anaerobic reactors applied to sewage treatment are energetically self-sufficient. This evaluation can be made by balancing the methane produced through the anaerobic transformation stages (hydrolysis, acidogenesis, acetogenesis and methanogenesis) and the reactor energy consumption requirements. The original project included methanogenic activity tests, which could not be performed due to setbacks in the installation of an analytical instrument. Scientific articles about bench- and full-scale anaerobic reactors were investigated instead. An average substrate-to-methane conversion efficiency of 58,2±18,6% was found for the bench-scale reactors and higher efficiencies (89,2%) were found for the cases which had higher Organic Loading Rates (OLRs) values. The average energy output was 0,013 kWh/Lsewage, value unable to meet the energy needs for the reactor operation, considering equipments normally used such as temperature controller. This balance can become positive if few hypotheses are made, for example (i) to eliminate the use of temperature controller (ii) to alter the operation pattern from continuous to intermittent. Based on energy balance assessment of eight bench-scale reactors, it was observed that the implementation of a system for biogas utilization is not energetically feasible. However, interesting results were found for a full-scale sewage treatment plant, ETE Ouro Verde – Foz do Iguaçu, PR, Brazil. Even though its substrate-tomethane conversion efficiency was about 10% only, the energy balance was quite positive, with energy consumption of 68 kWh/month and energy production of 660 kWh/month. This analysis leads us to conclude that energy recovery from full-scale sewage treatment plants should be practiced by other plants

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Irrigação e Drenagem) - FCA