958 resultados para Total knee replacement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The main goals of the standard treatment for advanced symptomatic knee osteoarthritis, total knee arthroplasty (TKA), are pain reduction and restoration of knee motion.The aim of this study was to analyse the outcome of the patient-based Knee Injury and Osteoarthritis Outcome Score (KOOS), and the surgeon-based Knee Society Score (KSS) and its Knee Score (KS) and Knee Functional Score (KFS) components after (TKA) using the Journey knee prosthesis, and to assess the correlation of these scores with range of motion (ROM). METHODS In a prospective case series study between August 1st 2008 and May 31st 2011, 99 patients, all operated by a single surgeon, received Journey bicruciate stabilized total knee prostheses. The female/male ratio was 53/34, the mean patient age at surgery was 68 years (range 41-83 years), and the left/right knee ratio was 55/44. The KOOS, range of motion, and KS and KFS were obtained preoperatively and at 1-year follow-up. The pre- and postoperative levels of the outcome measures were compared using the Wilcoxon signed-rank test. Correlation between ROM and patient outcomes was analysed with the Spearman coefficient. RESULTS All KOOS subscores improved significantly. Ninety percent of patients improved by at least the minimum clinically relevant difference of 10 points in stiffness and other symptoms, 94.5% in pain, 94.5% in activities of daily living, 84.9% in sports and recreation, and 90% in knee-related quality of life. The mean passive and active ROM improved from 122.4° (range 90-145°) and 120.4° (range 80-145°) preoperatively to 129.4° (range 90-145°) and 127.1° (range 100-145°) postoperatively. The highest correlation coefficients for ROM and KOOS were observed for the activity and pain subscores. Very low or no correlation was seen for the sport subscore.There was a significant and clinically relevant improvement of KSS (preop/postop 112.2/174.5 points), and its KS (preop/postop 45.6/86.8 points) and KFS (preop/postop 66.6/87.8 points) components. CONCLUSIONS The Journey bicruciate stabilized knee prosthesis showed good 1-year postoperative results in terms of both functional and patient-based outcome. However, higher knee ROM correlates only moderately with patient-based outcome, implying that functionality afforded by the Journey bicruciate TKA is not equivalent to patient satisfaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Even though arthroplasty of the ankle joint is considered to be an established procedure, only about 1,300 endoprostheses are implanted in Germany annually. Arthrodeses of the ankle joint are performed almost three times more often. This may be due to the availability of the procedure - more than twice as many providers perform arthrodesis - as well as the postulated high frequency of revision procedures of arthroplasties in the literature. In those publications, however, there is often no clear differentiation between revision surgery with exchange of components, subsequent interventions due to complications and subsequent surgery not associated with complications. The German Orthopaedic Foot and Ankle Association's (D. A. F.) registry for total ankle replacement collects data pertaining to perioperative complications as well as cause, nature and extent of the subsequent interventions, and postoperative patient satisfaction. MATERIAL AND METHODS The D. A. F.'s total ankle replacement register is a nation-wide, voluntary registry. After giving written informed consent, the patients can be added to the database by participating providers. Data are collected during hospital stay for surgical treatment, during routine follow-up inspections and in the context of revision surgery. The information can be submitted in paper-based or online formats. The survey instruments are available as minimum data sets or scientific questionnaires which include patient-reported outcome measures (PROMs). The pseudonymous clinical data are collected and evaluated at the Institute for Evaluative Research in Medicine, University of Bern/Switzerland (IEFM). The patient-related data remain on the register's module server in North Rhine-Westphalia, Germany. The registry's methodology as well as the results of the revisions and patient satisfaction for 115 patients with a two year follow-up period are presented. Statistical analyses are performed with SAS™ (Version 9.4, SAS Institute, Inc., Cary, NC, USA). RESULTS About 2½ years after the register was launched there are 621 datasets on primary implantations, 1,427 on follow-ups and 121 records on re-operation available. 49 % of the patients received their implants due to post-traumatic osteoarthritis, 27 % because of a primary osteoarthritis and 15 % of patients suffered from a rheumatic disease. More than 90 % of the primary interventions proceeded without complications. Subsequent interventions were recorded for 84 patients, which corresponds to a rate of 13.5 % with respect to the primary implantations. It should be noted that these secondary procedures also include two-stage procedures not due to a complication. "True revisions" are interventions with exchange of components due to mechanical complications and/or infection and were present in 7.6 % of patients. 415 of the patients commented on their satisfaction with the operative result during the last follow-up: 89.9 % of patients evaluate their outcome as excellent or good, 9.4 % as moderate and only 0.7 % (3 patients) as poor. In these three cases a component loosening or symptomatic USG osteoarthritis was present. Two-year follow-up data using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Scale (AOFAS-AHS) are already available for 115 patients. The median AOFAS-AHS score increased from 33 points preoperatively to more than 80 points three to six months postoperatively. This increase remained nearly constant over the entire two-year follow-up period. CONCLUSION Covering less than 10 % of the approximately 240 providers in Germany and approximately 12 % of the annually implanted total ankle-replacements, the D. A. F.-register is still far from being seen as a national registry. Nevertheless, geographical coverage and inclusion of "high-" (more than 100 total ankle replacements a year) and "low-volume surgeons" (less than 5 total ankle replacements a year) make the register representative for Germany. The registry data show that the number of subsequent interventions and in particular the "true revision" procedures are markedly lower than the 20 % often postulated in the literature. In addition, a high level of patient satisfaction over the short and medium term is recorded. From the perspective of the authors, these results indicate that total ankle arthroplasty - given a correct indication and appropriate selection of patients - is not inferior to an ankle arthrodesis concerning patients' satisfaction and function. First valid survival rates can be expected about 10 years after the register's start.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION Optimising the use of blood has become a core task of transfusion medicine. Because no general guidelines are available in Switzerland, we analysed the effects of the introduction of a guideline on red blood cell (RBC) transfusion for elective orthopaedic surgery. METHODS Prospective, multicentre, before-and-after study comparing the use of RBCs in adult elective hip or knee replacement before and after the implementation of a guideline in 10 Swiss hospitals, developed together with all participants. RESULTS We included 2,134 patients, 1,238 in 7 months before, 896 in 6 months after intervention. 57 (34 or 2.7% before, 23 or 2.6% after) were lost before follow-up visit. The mean number of transfused RBC units decreased from 0.5 to 0.4 per patient (0.1, 95% CI 0.08-0.2; p = 0.014), the proportion of transfused patients from 20.9% to 16.9% (4%, 95% C.I. 0.7-7.4%; p = 0.02), and the pre-transfusion haemoglobin from 82.6 to 78.2 g/l (4.4 g/l, 95% C. I. 2.15-6.62 g/l, p < 0.001). We did not observe any statistically significant changes in in-hospital mortality (0.4% vs. 0%) and morbidity (4.1% vs. 4.0%), median hospital length of stay (9 vs. 9 days), follow-up mortality (0.4% vs. 0.2%) and follow-up morbidity (6.9% vs. 6.0%). CONCLUSIONS The introduction of a simple transfusion guideline reduces and standardises the use of RBCs by decreasing the haemoglobin transfusion trigger, without negative effects on the patient outcome. Local support, training, and monitoring of the effects are requirements for programmes optimising the use of blood.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anticoagulation used for thromboembolic prophylaxis following total knee arthroplasty (TKA) could interfere with movement. This study compares the effect of 2 anticoagulants, enoxaparin and aspirin, on restoration of range of motion (ROM) after TKA. Two groups of 75 consecutive patients, matched for age, arthritic severity, and preoperative ROM, underwent TKA. Flexion and extension milestone measures were recorded daily. Results show a highly statistically significant difference (P

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total knee arthroplasty (TKA) has revolutionized the life of millions of patients and it is the most efficient treatment in cases of osteoarthritis. The increase in life expectancy has lowered the average age of the patient, which requires a more enduring and performing prosthesis. To improve the design of implants and satisfying the patient's needs, a deep understanding of the knee Biomechanics is needed. To overcome the uncertainties of numerical models, recently instrumented knee prostheses are spreading. The aim of the thesis was to design and manifacture a new prototype of instrumented implant, able to measure kinetics and kinematics (in terms of medial and lateral forces and patellofemoral forces) of different interchangeable designs of prosthesis during experiments tests within a research laboratory, on robotic knee simulator. Unlike previous prototypes it was not aimed for industrial applications, but purely focusing on research. After a careful study of the literature, and a preliminary analytic study, the device was created modifying the structure of a commercial prosthesis and transforming it in a load cell. For monitoring the kinematics of the femoral component a three-layers, piezoelettric position sensor was manifactured using a Velostat foil. This sensor has responded well to pilot test. Once completed, such device can be used to validate existing numerical models of the knee and of TKA and create new ones, more accurate.It can lead to refinement of surgical techniques, to enhancement of prosthetic designs and, once validated, and if properly modified, it can be used also intraoperatively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La sostituzione totale d’anca è uno degli interventi chirurgici con le più alte percentuali di successo. Esistono due varianti di protesi d’anca che differiscono in base al metodo di ancoraggio all’osso: cementate (fissaggio tramite cemento osseo) e non cementate (fissaggio tramite forzamento). Ad oggi, i chirurghi non hanno indicazioni quantitative di supporto per la scelta fra le due tipologie di impianto, decidendo solo in base alla loro esperienza. Due delle problematiche che interessano le protesi non cementate sono la possibilità di frattura intra-operatoria durante l’inserimento forzato e il riassorbimento osseo nel periodo di tempo successivo all’intervento. A partire da rilevazioni densitometriche effettuate su immagini da TC di pazienti sottoposti a protesi d’anca non cementata, sono stati sviluppati due metodi: 1) per la valutazione del rischio di frattura intra-operatorio tramite analisi agli elementi finiti; 2) per la valutazione della variazione di densità minerale ossea (tridimensionalmente attorno alla protesi) dopo un anno dall’operazione. Un campione di 5 pazienti è stato selezionato per testare le procedure. Ciascuno dei pazienti è stato scansionato tramite TC in tre momenti differenti: una acquisita prima dell’operazione (pre-op), le altre due acquisite 24 ore (post 24h) e 1 anno dopo l’operazione (post 1y). I risultati ottenuti hanno confermato la fattibilità di entrambi i metodi, riuscendo inoltre a distinguere e a quantificare delle differenze fra i vari pazienti. La fattibilità di entrambe le metodologie suggerisce la loro possibilità di impiego in ambito clinico: 1) conoscere la stima del rischio di frattura intra-operatorio può servire come strumento di guida per il chirurgo nella scelta dell’impianto protesico ottimale; 2) conoscere la variazione di densità minerale ossea dopo un anno dall’operazione può essere utilizzato come strumento di monitoraggio post-operatorio del paziente.