103 resultados para Torso


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The curvature sensors are based on long-period gratings (LPGs) written in a progressive three-layered fiber to render the LPGs insensitive to the refractive index external to the fiber. A curvature sensor consists of the fiber long-period grating laid on a carbon fiber ribbon, which is then encapsulated in a low-temperature curing silicone rubber. The sensors have a spectral sensitivity to curvature, d lambda/dR from similar to 7-nm m to similar to 9-nm m. The interrogation technique is borrowed from derivative spectroscopy and monitors the changes in the transmission spectral profile of the LPG's attenuation band due to curvature. The multiplexing of the sensors is achieved by spectrally matching a series of distributed feedback (DFB) lasers to the LPGs. The versatility of this sensing garment is confirmed by it being used on six other human subjects covering a wide range of body mass indices. Just six fully functional sensors are required to obtain a volumetric error of around 6%. (C) 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An array of in-line curvature sensors on a garment is used to monitor the thoracic and abdominal movements of a human during respiration. The results are used to obtain volumetric changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The array of 40 in-line fiber Bragg gratings is used to produce 20 curvature sensors at different locations, each sensor consisting of two fiber Bragg gratings. The 20 curvature sensors and adjoining fiber are encapsulated into a low-temperature-cured synthetic silicone. The sensors are wavelength interrogated by a commercially available system from Moog Insensys, and the wavelength changes are calibrated to recover curvature. A three-dimensional algorithm is used to generate shape changes during respiration that allow the measurement of absolute volume changes at various sections of the torso. It is shown that the sensing scheme yields a volumetric error of 6%. Comparing the volume data obtained from the spirometer with the volume estimated with the synchronous data from the shape-sensing array yielded a correlation value 0.86 with a Pearson's correlation coefficient p <0.01.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Respiratory-volume monitoring is an indispensable part of mechanical ventilation. Here we present a new method of the respiratory-volume measurement based on a single fibre-optical long-period sensor of bending and the correlation between torso curvature and lung volume. Unlike the commonly used air-flow based measurement methods the proposed sensor is drift-free and immune to air-leaks. In the paper, we explain the working principle of sensors, a two-step calibration-test measurement procedure and present results that establish a linear correlation between the change in the local thorax curvature and the change of the lung volume. We also discuss the advantages and limitations of these sensors with respect to the current standards. © 2013 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An array of in-line curvature sensors on a garment is used to monitor the thoracic and abdominal movements of a human during respiration. The results are used to obtain volumetric changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The array of 40 in-line fiber Bragg gratings is used to produce 20 curvature sensors at different locations, each sensor consisting of two fiber Bragg gratings. The 20 curvature sensors and adjoining fiber are encapsulated into a low-temperature-cured synthetic silicone. The sensors are wavelength interrogated by a commercially available system from Moog Insensys, and the wavelength changes are calibrated to recover curvature. A three-dimensional algorithm is used to generate shape changes during respiration that allow the measurement of absolute volume changes at various sections of the torso. It is shown that the sensing scheme yields a volumetric error of 6%. Comparing the volume data obtained from the spirometer with the volume estimated with the synchronous data from the shape-sensing array yielded a correlation value 0.86 with a Pearson's correlation coefficient p <0.01.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We demonstrate the use of a series of in-line fibre long period grating curvature sensors on a garment, used to monitor the thoracic and abdominal volumetric tidal movements of a human subject. These results are used to obtain volumetric tidal changes of the human torso showing reasonable agreement with a spirometer used simultaneously to record the volume at the mouth during breathing. The curvature sensors are based upon long period gratings written in a progressive three layered fibre that are insensitive to refractive index changes. The sensor platform consists of the long period grating laid upon a carbon fibre ribbon, which is encapsulated in a low temperature curing silicone rubber.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso showing reasonable agreement with a spirometer used simultaneously to record the volume at the mouth during breathing. The curvature sensors are based upon long period gratings written in a progressive three layered fibre that are insensitive to refractive index changes. The sensor platform consists of the long period grating laid upon a carbon fibre ribbon, which is encapsulated in a low temperature curing silicone rubber. An array of sensors is also used to reconstruct the shape changes of a resuscitation manikin during simulated respiration. The data for reconstruction is obtained by two methods of multiplexing and interrogation: firstly using the transmission spectral profile of the LPG's attenuation bands measured using an optical spectrum analyser; secondly using a derivative spectroscopy technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, multiplexed sensor network capable of monitoring the shape changes of the torso for respiratory function monitoring is developed. As a demonstration, LPGs written into refractive index insensitive, progressive three layered fibre are embedded into supporting material is then placed on a resuscitation training manikin simulating respiration. A derivative spectroscopy interrogation technique is implemented and the bend sensitivity of the LPGs is used to reconstruct the shape of the manikin's torso. © 2003 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A series of in-line curvature sensors on a garment are used to monitor the thoracic and abdominal movements of a human during respiration. These results are used to obtain volumetric tidal changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The curvature sensors are based on long-period gratings (LPGs) written in a progressive three-layered fiber to render the LPGs insensitive to the refractive index external to the fiber. A curvature sensor consists of the fiber long-period grating laid on a carbon fiber ribbon, which is then encapsulated in a low-temperature curing silicone rubber. The sensors have a spectral sensitivity to curvature, dλ/dR from ∼7-nm m to ∼9-nm m. The interrogation technique is borrowed from derivative spectroscopy and monitors the changes in the transmission spectral profile of the LPG's attenuation band due to curvature. The multiplexing of the sensors is achieved by spectrally matching a series of distributed feedback (DFB) lasers to the LPGs. The versatility of this sensing garment is confirmed by it being used on six other human subjects covering a wide range of body mass indices. Just six fully functional sensors are required to obtain a volumetric error of around 6%. © 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the most popular techniques for creating spatialized virtual sounds is based on the use of Head-Related Transfer Functions (HRTFs). HRTFs are signal processing models that represent the modifications undergone by the acoustic signal as it travels from a sound source to each of the listener's eardrums. These modifications are due to the interaction of the acoustic waves with the listener's torso, shoulders, head and pinnae, or outer ears. As such, HRTFs are somewhat different for each listener. For a listener to perceive synthesized 3-D sound cues correctly, the synthesized cues must be similar to the listener's own HRTFs. ^ One can measure individual HRTFs using specialized recording systems, however, these systems are prohibitively expensive and restrict the portability of the 3-D sound system. HRTF-based systems also face several computational challenges. This dissertation presents an alternative method for the synthesis of binaural spatialized sounds. The sound entering the pinna undergoes several reflective, diffractive and resonant phenomena, which determine the HRTF. Using signal processing tools, such as Prony's signal modeling method, an appropriate set of time delays and a resonant frequency were used to approximate the measured Head-Related Impulse Responses (HRIRs). Statistical analysis was used to find out empirical equations describing how the reflections and resonances are determined by the shape and size of the pinna features obtained from 3D images of 15 experimental subjects modeled in the project. These equations were used to yield “Model HRTFs” that can create elevation effects. ^ Listening tests conducted on 10 subjects show that these model HRTFs are 5% more effective than generic HRTFs when it comes to localizing sounds in the frontal plane. The number of reversals (perception of sound source above the horizontal plane when actually it is below the plane and vice versa) was also reduced by 5.7%, showing the perceptual effectiveness of this approach. The model is simple, yet versatile because it relies on easy to measure parameters to create an individualized HRTF. This low-order parameterized model also reduces the computational and storage demands, while maintaining a sufficient number of perceptually relevant spectral cues. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN]In visual surveillance face detection can be an important cue for initializing tracking algorithms. Recent work in psychophics hints at the importance of the local context of a face for robust detection, such as head contours and torso. This paper describes a detector that actively utilizes the idea of local context. The promise is to gain robustness that goes beyond the capabilities of traditional face detection making it particularly interesting for surveillance. The performance of the proposed detector in terms of accuracy and speed is evaluated on data sets from PETS 2000 and PETS 2003 and compared to the object-centered approach. Particular attention is paid to the role of available image resolution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Atualmente, a utilização e as diversas aplicações de materiais poliméricos seguem tendências crescentes, pelo que se torna necessário aprofundar a compreensão do seu comportamento e funcionalidades. Neste contexto, na presente dissertação analisa-se a fabricação e características de rolamentos poliméricos para a suspensão automóvel. Estes rolamentos visam a substituição dos clássicos rolamentos metálicos. Esta substituição tem por objetivos garantir a melhoria do funcionamento dos rolamentos, bem como o seu usufruto, contribuindo para um maior conforto e segurança dos passageiros e para uma redução do peso do veículo, com consequente diminuição do consumo do combustível e melhoria da eficiência. Sendo o poliacetal (POM) e a poliamida (PA) considerados polímeros de alto desempenho, estes polímeros reúnem boas características para aplicação na fabricação de dispositivos com funcionalidades exigentes como é o caso dos rolamentos. O presente trabalho aborda o estudo de algumas das suas propriedades, de modo a obter informações relevantes quanto à respetiva aplicação em rolamentos de suspensão, tendo como foco principal a análise da matéria-prima utilizada. Deste modo, alteraram-se as formulações variando-se os teores de material virgem e reciclado, estudou-se o ser comportamento mecânico, reológico e térmico: fizeram-se análises reológicas através do estudo do MFI a fim de se obterem informações complementares ao estudo mecânico, realizaram-se análises térmicas para avaliar a possibilidade de degradação térmica do material e, no caso da PA66-30GF, recorreu-se à microscopia eletrónica de varrimento para se estudar os aspetos microestruturais deste compósito reforçado com fibra de vidro. Adicionalmente, procedeu-se à análise da rugosidade superficial dos componentes dos rolamentos e quantificou-se o torque dos mesmos. A partir dos estudos anteriores, foi possível concluir que o POM apresenta um comportamento mecânico estável mesmo utilizando uma formulação com 100% de material reciclado. Este comportamento não se verificou na PA6630GF, dado que as suas propriedades mecânicas são afetadas de forma significativa pelo teor de reciclado na formulação. Com o estudo do torque determinou-se o valor limite do momento de torsão do rolamento que garante o seu bom funcionamento e eficácia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Na prática clínica, a diversidade de instrumentos manuais, rotatórios ou reciprocantes, dificulta a seleção do sistema a aplicar no retratamento dentário não cirúrgico. O presente trabalho teve como objetivo comparar diferentes instrumentos quanto a diferentes parâmetros: capacidade de remoção de Gutta-Percha (GP), extrusão apical de detritos, fratura de instrumentos, e ocorrência de iatrogenias. Neste trabalho foram utilizadas 111 publicações posteriores a 2011, obtidas via PubMed e Science Direct. A análise da bibliografia indica que, independentemente do sistema, não é possível remover todo o material obturador das paredes radiculares, sendo esta tarefa dificultada em canais curvos e na área apical. Verifica-se que a remoção de GP melhora no sentido: limas H, ProTaper, e Mtwo. O sistema Reciproc foi associado a melhores desempenhos e a menores tempo de trabalho, do que os sistemas de rotação contínua. Nenhum dos instrumentos analisados é capaz de evitar a extrusão apical de detritos na totalidade. Apesar de resultados dispares, a maioria dos estudos assume que o sistema Reciproc provoca menor extrusão apical de detritos. Em Endodontia, as duas principais causas da fratura de instrumentos são a fadiga cíclica e a torsão. A maioria dos estudos concordam que o movimento reciprocante, como o do Reciproc, aumenta a resistência à fractura e a resistência à torsão, mantendo a anatomia original do canal. Relativamente à produção de perfurações e fracturas radiculares, a superioridade dos instrumentos NiTi relativamente às limas manuais não foi clara. De acordo com a literatura, o sistema Reciproc, constituído por liga de NiTi M-Wire, está associado a menos eventos iatrogénicos. Finalmente, conclui-se que futuros estudos seriam benéficos para esclarecer o potencial dos diferentes sistemas estudados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El impacto que ha generado el trauma en Colombia a lo largo de la historia, nos ha obligado a mejorar y adaptar diferentes tipos de sistemas de atención en trauma, basados en los lineamientos internacionales, los cuales buscan evitar el significativo aumento en las tasas de mortalidad y discapacidad que se obtienen de este, especialmente en los servicios de Emergencias en los cuales se reciben el 100% de estos pacientes con traumatismo múltiple o politraumatismo. Dentro de este grupo de pacientes hay un subgrupo que son las pacientes con trauma de abdomen que cursan con estabilidad hemodinámica y además son clasificados de bajo riesgo, ya sea por índices de trauma o por otros métodos como la medición sérica de lactato, los cuales tienen un papel poco despreciable al momento de ver mortalidad y discapacidad por trauma, ya sea penetrante o cerrado; en este trabajo específicamente nos centramos en las personas que consultan al servicio de Emergencias con trauma cerrado de abdomen los cuales son considerados de bajo riesgo, siendo este subgrupo de pacientes uno de los más difíciles de abordar y enfocar al momento de la valoración inicial, ya que se debe tener la seguridad de que no hay lesiones que comprometen la vida y por consiguiente estos pacientes puedan ser dados de alta.