837 resultados para Textile effluent


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examine the trade credit linkages among firms within a supply chain to reckon the effect of such linkages on the propagation of liquidity shocks from downstream to upstream firms. We choose a sample appropriate for this task, consisting of a large data set of Italian firms from the textile industry, a well known example of a comprehensive manufacturing cluster featuring a large number of small and specialized firms at each level of the supply chain. The results of the analysis indicate that the level of trade credit that firms provide to their suppliers is positively related to the level of trade credit granted to their clients: when the level of trade credit granted to clients divided by sales goes up by 1, the level of trade credit provided to suppliers divided by cost-of goods-sold goes up by an amount that varies between 0,22 and 0,52. Since all firms along the chain are linked by trade credit relationships, an increase in the level of trade credit granted by wholesalers generates a liquidity cascade throughout the chain. We designate the overall increase in the level of trade credit among all firms in the chain as a result of a unitary impulse in the level of trade credit granted by wholesalers as the multiplier effect of trade credit for the industry chain. We estimate such multiplier to vary between 1.28 and 2.04. We also investigate the effect of final demand on the level of trade credit sourced by firms at various levels of the chain and, in particular, whether such effect is amplified for firms further up in the chain as a result of liquidity propagation via trade credit linkages. We uncover evidence of such amplification when the links of liquidity transmission along the chain are individually modeled and estimated. An unitary increase in wholesalers’ sales is found to produce an effect on trade payables among firms at the top of the chain (i.e., Preparers and Spinners) that is more than twice as big as the corresponding effect among firms at the bottom of the chain (i.e., Wholesalers).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purification capacity of a laboratory scale tidal flow reed bed system with final effluent recirculation at a ratio of 1:1 was investigated in this study. In particular, this four-stage reed bed system was highly loaded with strong agricultural wastewater. Under the hydraulic and organic loading rates as high as 0.43 m3/m2d and 1055 gCOD/m2d, respectively, the average removal efficiencies of COD, BOD5, SS, NH4-N and P were 77%, 78%, 66%, 62% and 38%. Even with the high loading rates, approximately 30% of NH4-N was converted into NO2-N and NO3-N from the mid-stage of the system where nitrification took place. The results suggest that the multi-stage reed bed system could be employed to treat strong wastewater under high loading, especially for the substantive mass removal of solids, organic matter and ammoniacal-nitrogen. Tidal flow combined with effluent recirculation is a favourable operation strategy to achieve this objective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of using diatomite for the removal of the problematic reactive dyes as well as basic dyes from textile wastewater was investigated. Methylene blue, Cibacron reactive black and reactive yellow dyes were considered. Physical characteristics of diatomite such as pH(solution), pH(ZPC), surface area, Fourier transform infrared, and scanning electron microscopy were investigated. The surface area of diatomite was found to be 27.80 m(2) g(-1) and the pH(ZPC) occurred around pH of 5.4. The results indicated that the surface charge of diatomite decreased as the pH of the solution increased with the maximum methylene blue removal from aqueous solution occurring at basic pH of around (1011). Adsorption isotherms of diatomite with methylene blue, hydrolysed reactive black and yellow dyes were constructed at different pH values, initial dye concentrations and particle sizes. The experimental results were fitted to the Langmuir, Freundlich, and Henry models. The study indicated that electrostatic interactions play an important role in the adsorption of dyes onto diatomite. A model of the adsorption mechanism of methylene blue onto diatomite is proposed. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The coplanar microscale atmospheric pressure plasma jet (µ-APPJ) is a capacitively coupled radio frequency discharge (13.56 MHz, ~15W rf power) designed for optimized optical diagnostic access. It is operated in a homogeneous glow mode with a noble gas flow (1.4 slm He) containing a small admixture of molecular oxygen (~0.5%). Ground state atomic oxygen densities in the effluent up to 2 × 1014 cm-3 are measured by two-photon absorption laser-induced fluorescence spectroscopy (TALIF) providing space resolved density maps. The quantitative calibration of the TALIF setup is performed by comparative measurements with xenon. A maximum of the atomic oxygen density is observed for 0.6% molecular oxygen admixture. Furthermore, an increase in the rf power up to about 15W (depending on gas flow and mixture) leads to an increase in the effluent’s atomic oxygen density, then reaching a constant level for higher powers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The planar 13.56MHz RF-excited low temperature atmospheric pressure plasma jet (APPJ) investigated in this study is operated with helium feed gas and a small molecular oxygen admixture. The effluent leaving the discharge through the jet’s nozzle contains very few charged particles and a high reactive oxygen species’ density. As its main reactive radical, essential for numerous applications, the ground state atomic oxygen density in the APPJ’s effluent is measured spatially resolved with two-photon absorption laser induced fluorescence spectroscopy. The atomic oxygen density at the nozzle reaches a value of ~1016 cm-3. Even at several centimetres distance still 1% of this initial atomic oxygen density can be detected. Optical emission spectroscopy (OES) reveals the presence of short living excited oxygen atoms up to 10 cm distance from the jet’s nozzle. The measured high ground state atomic oxygen density and the unaccounted for presence of excited atomic oxygen require further investigations on a possible energy transfer from the APPJ’s discharge region into the effluent: energetic vacuum ultraviolet radiation, measured by OES down to 110 nm, reaches far into the effluent where it is presumed to be responsible for the generation of atomic oxygen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The farm production of silage as a winter-feed supplement is widespread. However, the bins in which silage is produced are subject to acidic and microbial attacks. Both these types of attack can lead to a weakening and failure of the concretes, especially on the outer lip of the open side of the silage pit. Consequently, the development of an acid-resistant concrete that can extend the life span of silage bins on farms could lead to considerable cost savings for farmers and, hence, can improve farm productivity. This paper reports on test results of an investigation into the behaviour of concrete containing seawater-neutralised bauxite refinery residues (Bauxsol™) exposed to sulphuric acid environments in the laboratory and to silage effluents. The concrete manufactured had a fixed water–cement ratio of 0.55 and natural sand was replaced with the Bauxsol™ at 0%, 5%, 10%, 15% and 20% by cement mass. Results indicated that the use of Bauxsol™ as a sand replacement material improved the behaviour of concrete both in sulphuric acid in the laboratory as well as in the silage effluent. Consequently, it is concluded that the Bauxsol™ can be used to replace 10% of natural sand to produce concrete that is resistant to silage effluents, providing an extended service life over conventional concretes used in silage pits.