958 resultados para Technology Assessment, Biomedical


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Item 1070-M (v. 1)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Item 1070-M

Relevância:

90.00% 90.00%

Publicador:

Resumo:

"OTA-CIT-147"--P. 4 of cover.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Fetal pulse oximetry (FPO) may improve the assessment of the fetal well-being in labour. Reports of health-care provider's evaluations of new technology are important in the overall evaluation of that technology. Aims: To determine doctors' and midwives' perceptions of their experience placing FPO sensors. Methods: We surveyed clinicians (midwives and doctors) following placement of a FPO sensor during the FOREMOST trial (multicentre randomised trial of fetal pulse oximetry). Clinicians rated ease of sensor placement (poor, fair, good and excellent). Potential influences on ease of sensor placement (staff category, prior experience in Birth Suite, prior experience in placing sensors, epidural analgesia, cervical dilatation and fetal station) were examined by ordinal regression. Results: There were 281 surveys returned for the 294 sensor placement attempts (response rate 96%). Sensors were placed by midwives (29%), research midwives (48%), registrars (22%) and obstetricians (1%). The majority of clinicians had 1 or more years' Birth Suite experience, had placed six or more sensors previously, and rated ease of sensor placement as good. Advancing fetal station (P < 0.001) and the presence of epidural analgesia prior to sensor placement (P = 0.029) predicted improved ease of sensor placement. Having a clinician placing a sensor for the first time predicted a lower rating for ease of sensor placement (P = 0.001), compared to having placed one or more sensors previously. Conclusions: Clinicians with varying levels of Birth Suite experience successfully placed fetal oxygen saturation sensors, with the majority rating ease of sensor placement as good.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The status of Science and Technology in KUWAIT has been analysed in order to assess the extent of the application of Science and Technology needed for the Country's development. The design and implementation of a Science and Technology Policy has been examined to identify the appropriate technology necessary to improve KUWAIT's socio-economic-industrial structures. Following a general and critical review of the role of Science and Technology in the developing countries, the author has reviewed the past and contemporary employment of Science and Technology for development.of various sectors and the existence, if any, of any form (explicit, implicit, or both) of a Science and Technology Policy in KUWAIT. The thesis is structured to evaluate almost all of the sectors in KUWAIT which utilise Science and/or Technology, the effectiveness of such practices, their policymaking process, the channels by which policies were transformed into sources of influence through Governmental action and the impact that various policy instruments at the disposal of the the Government had on the development of S & T capabilities. The author has studied the implications of the absence of a Science and Technology Policy in Kuwait by examining some specific case studies, eg, the absence of a Technology Assessment Process and the negative impacts resulting from this; the ad-hoc allocation of the research and development budget instead of its being based on a percentage of GNP; the limitations imposed on the development of indigenous contracting companies and consultancy and engineering design offices; the impacts of the absence of Technology Transfer Centre, and so forth. As a consequence of the implications of the above studies, together with the negative results from the absence of an explicit Science and Technology Policy, eg, research and development activities do not relate to the national development plans, the author suggests that a Science and Technology Policy-Making Body should be established to formulate, develop, monitor and correlate the Science and Technology Activities in KUWAIT.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

FUNDING & ACKNOWLEDGEMENTS This project was funded by the NIHR Health Technology Assessment programme (project number 05/47/02) and is published in full in Health Technology Assessment; Vol. 19, No. 80. Further information available at: http://www.nets.nihr.ac.uk/projects/hta/054702 This paper presents independent research commissioned by the National Institute for Health Research (NIHR). The views and opinions expressed by authors in this publication are those of the authors and do not necessarily reflect those of the NHS, the NIHR, MRC, CCF, NETSCC, the HTA programme or the Department of Health. Due to the confidential nature of the trial data supporting this publication not all of the data can be made accessible to other researchers. Please contact the UKUFF study principal investigator Andrew Carr (andrew.carr@ndorms.ox.ac.uk) for more information. The authors wish to thank the UKUFF trial collaborators for their contribution in managing the conduct of the trial, and for their comments on the interim economic results: Marion Campbell and Hannah Bruhn (Centre for Healthcare Randomised Trials, HSRU, University of Aberdeen), Jonathan Rees MD and David Beard (NDORMS, University of Oxford; NIHR Oxford Biomedical Research Centre), Jane Moser (NDORMS, University of Oxford), Raymond Fitzpatrick and Jill Dawson (NDPH, University of Oxford).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The cortisol awakening response (CAR) is typically measured in the domestic setting. Moderate sample timing inaccuracy has been shown to result in erroneous CAR estimates and such inaccuracy has been shown partially to explain inconsistency in the CAR literature. The need for more reliable measurement of the CAR has recently been highlighted in expert consensus guidelines where it was pointed out that less than 6% of published studies provided electronic-monitoring of saliva sampling time in the post-awakening period. Analyses of a merged data-set of published studies from our laboratory are presented. To qualify for selection, both time of awakening and collection of the first sample must have been verified by electronic-monitoring and sampling commenced within 15 min of awakening. Participants (n = 128) were young (median age of 20 years) and healthy. Cortisol values were determined in the 45 min post-awakening period on 215 sampling days. On 127 days, delay between verified awakening and collection of the first sample was less than 3 min (‘no delay’ group); on 45 days there was a delay of 4–6 min (‘short delay’ group); on 43 days the delay was 7–15 min (‘moderate delay’ group). Cortisol values for verified sampling times accurately mapped on to the typical post-awakening cortisol growth curve, regardless of whether sampling deviated from desired protocol timings. This provides support for incorporating rather than excluding delayed data (up to 15 min) in CAR analyses. For this population the fitted cortisol growth curve equation predicted a mean cortisol awakening level of 6 nmols/l (±1 for 95% CI) and a mean CAR rise of 6 nmols/l (±2 for 95% CI). We also modelled the relationship between real delay and CAR magnitude, when the CAR is calculated erroneously by incorrectly assuming adherence to protocol time. Findings supported a curvilinear hypothesis in relation to effects of sample delay on the CAR. Short delays of 4–6 min between awakening and commencement of saliva sampling resulted an overestimated CAR. Moderate delays of 7–15 min were associated with an underestimated CAR. Findings emphasize the need to employ electronic-monitoring of sampling accuracy when measuring the CAR in the domestic setting.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Decision-analytic modelling (DAM) has become a widespread method in health technology assessments (HTA), but the extent to which modelling is used differs among international HTA institutions. In Germany, the use of DAM is optional within HTAs of the German Institute of Medical Documentation and Information (DIMDI). Our study examines the use of DAM in DIMDI HTA reports and its effect on the quality of information provided for health policies. METHODS: A review of all DIMDI HTA reports (from 1998 to September 2012) incorporating an economic assessment was performed. All included reports were divided into two groups: HTAs with DAM and HTAs without DAM. In both groups, reports were categorized according to the quality of information provided for healthcare decision making. RESULTS: Of the sample of 107 DIMDI HTA reports, 17 (15.9%) used DAM for economic assessment. In the group without DAM, conclusions were limited by the quality of economic information in 51.1% of the reports, whereas we did not find limited conclusions in the group with DAM. Furthermore, 24 reports without DAM (26.7%) stated that using DAM would likely improve the quality of information of the economic assessment. CONCLUSION: The use of DAM techniques can improve the quality of HTAs in Germany. When, after a systematic review of existing literature within a HTA, it is clear that DAM is likely to positively affect the quality of the economic assessment DAM should be used.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper investigates the robust and accurate capture of human joint poses and bio-kinematic movements for exercise monitoring in real-time tele-rehabilitation applications. Recently developed model-based estimation ideas are used to improve the accuracy, robustness, and real-time characteristics considered vital for applications, where affordability and domestic use are the primary focus. We use the spatial diversity of the arbitrarily positioned Microsoft Kinect receivers to improve the reliability and promote the uptake of the concept. The skeleton-based information is fused to enhance accuracy and robustness, critical for biomedical applications. A specific version of a robust Kalman filter (KF) in a linear framework is employed to ensure superior estimator convergence and real-time use, compared to other commonly used filters. The algorithmic development was conducted in a generic form and computer simulations were conducted to verify our assertions. Hardware implementations were carried out to test the viability of the proposed state estimator in terms of the core requirements of reliability, accuracy, and real-time use. Performance of the overall system implemented in an information fusion context was evaluated against the commercially available and industry standard Vicon system for different exercise routines, producing comparable results with much less infrastructure and financial investment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Technology assisted methods for medical diagnosis and biomedical health monitoring are rapidly shifting from classical invasive methods to handheld-based non-invasive approaches. Biomedical imagining is one of the most prominent practices of non-invasive mechanisms in medical applications. This paper considers the medical imaging schemes for Mobile Health (mHealth) applications and studies the feasibility of future mobile systems for accommodating image informatics capabilities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Reducing rates of healthcare acquired infection has been identified by the Australian Commission on Safety and Quality in Health Care as a national priority. One of the goals is the prevention of central venous catheter-related bloodstream infection (CR-BSI). At least 3,500 cases of CR-BSI occur annually in Australian hospitals, resulting in unnecessary deaths and costs to the healthcare system between $25.7 and $95.3 million. Two approaches to preventing these infections have been proposed: use of antimicrobial catheters (A-CVCs); or a catheter care and management ‘bundle’. Given finite healthcare budgets, decisions about the optimal infection control policy require consideration of the effectiveness and value for money of each approach. Objectives: The aim of this research is to use a rational economic framework to inform efficient infection control policy relating to the prevention of CR-BSI in the intensive care unit. It addresses three questions relating to decision-making in this area: 1. Is additional investment in activities aimed at preventing CR-BSI an efficient use of healthcare resources? 2. What is the optimal infection control strategy from amongst the two major approaches that have been proposed to prevent CR-BSI? 3. What uncertainty is there in this decision and can a research agenda to improve decision-making in this area be identified? Methods: A decision analytic model-based economic evaluation was undertaken to identify an efficient approach to preventing CR-BSI in Queensland Health intensive care units. A Markov model was developed in conjunction with a panel of clinical experts which described the epidemiology and prognosis of CR-BSI. The model was parameterised using data systematically identified from the published literature and extracted from routine databases. The quality of data used in the model and its validity to clinical experts and sensitivity to modelling assumptions was assessed. Two separate economic evaluations were conducted. The first evaluation compared all commercially available A-CVCs alongside uncoated catheters to identify which was cost-effective for routine use. The uncertainty in this decision was estimated along with the value of collecting further information to inform the decision. The second evaluation compared the use of A-CVCs to a catheter care bundle. We were unable to estimate the cost of the bundle because it is unclear what the full resource requirements are for its implementation, and what the value of these would be in an Australian context. As such we undertook a threshold analysis to identify the cost and effectiveness thresholds at which a hypothetical bundle would dominate the use of A-CVCs under various clinical scenarios. Results: In the first evaluation of A-CVCs, the findings from the baseline analysis, in which uncertainty is not considered, show that the use of any of the four A-CVCs will result in health gains accompanied by cost-savings. The MR catheters dominate the baseline analysis generating 1.64 QALYs and cost-savings of $130,289 per 1.000 catheters. With uncertainty, and based on current information, the MR catheters remain the optimal decision and return the highest average net monetary benefits ($948 per catheter) relative to all other catheter types. This conclusion was robust to all scenarios tested, however, the probability of error in this conclusion is high, 62% in the baseline scenario. Using a value of $40,000 per QALY, the expected value of perfect information associated with this decision is $7.3 million. An analysis of the expected value of perfect information for individual parameters suggests that it may be worthwhile for future research to focus on providing better estimates of the mortality attributable to CR-BSI and the effectiveness of both SPC and CH/SSD (int/ext) catheters. In the second evaluation of the catheter care bundle relative to A-CVCs, the results which do not consider uncertainty indicate that a bundle must achieve a relative risk of CR-BSI of at least 0.45 to be cost-effective relative to MR catheters. If the bundle can reduce rates of infection from 2.5% to effectively zero, it is cost-effective relative to MR catheters if national implementation costs are less than $2.6 million ($56,610 per ICU). If the bundle can achieve a relative risk of 0.34 (comparable to that reported in the literature) it is cost-effective, relative to MR catheters, if costs over an 18 month period are below $613,795 nationally ($13,343 per ICU). Once uncertainty in the decision is considered, the cost threshold for the bundle increases to $2.2 million. Therefore, if each of the 46 Level III ICUs could implement an 18 month catheter care bundle for less than $47,826 each, this approach would be cost effective relative to A-CVCs. However, the uncertainty is substantial and the probability of error in concluding that the bundle is the cost-effective approach at a cost of $2.2 million is 89%. Conclusions: This work highlights that infection control to prevent CR-BSI is an efficient use of healthcare resources in the Australian context. If there is no further investment in infection control, an opportunity cost is incurred, which is the potential for a more efficient healthcare system. Minocycline/rifampicin catheters are the optimal choice of antimicrobial catheter for routine use in Australian Level III ICUs, however, if a catheter care bundle implemented in Australia was as effective as those used in the large studies in the United States it would be preferred over the catheters if it was able to be implemented for less than $47,826 per Level III ICU. Uncertainty is very high in this decision and arises from multiple sources. There are likely greater costs to this uncertainty for A-CVCs, which may carry hidden costs, than there are for a catheter care bundle, which is more likely to provide indirect benefits to clinical practice and patient safety. Research into the mortality attributable to CR-BSI, the effectiveness of SPC and CH/SSD (int/ext) catheters and the cost and effectiveness of a catheter care bundle in Australia should be prioritised to reduce uncertainty in this decision. This thesis provides the economic evidence to inform one area of infection control, but there are many other infection control decisions for which information about the cost-effectiveness of competing interventions does not exist. This work highlights some of the challenges and benefits to generating and using economic evidence for infection control decision-making and provides support for commissioning more research into the cost-effectiveness of infection control.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Business processes have emerged as a well-respected variable in the design of successful corporations. However, unlike other key managerial variables, such as products and services, customers and employees, physical or digital assets, the conceptualization and management of business processes are in many respects in their infancy. In this book, Jan Recker investigates the notion of quality of business process modeling grammars. His evaluation is based on an ontological-, qualitative-, and quantitative analysis, applied to BPMN, a widely-used business process modeling grammar. His results reveal the ontological shortcomings of BPMN and how these manifest themselves in actual process modeling practice, as well as how they influence the usage behavior of modeling practitioners. More generally, his book constitutes a landmark for empirical technology assessment, analyzing the way in which design flaws in technology influence usage behavior.