977 resultados para TOTAL ARTIFICIAL-HEART
Resumo:
Since the inception of cardiopulmonary bypass (CPB), little progress has been made concerning the design of cardiotomy suction (CS). Because this is a major source of hemolysis, we decided to test a novel device (Smartsuction [SS]) specifically aimed at minimizing hemolysis during CPB in a clinical setting. Block randomization was carried out on a treated group (SS, n=28) and a control group (CTRL, n=26). Biochemical parameters were taken pre-, peri-, and post CPB and were compared between the two groups using the Student's t-test with statistical significance when P<0.05. No significant differences in patient demographics were observed between the two groups. Lactate dehydrogenase (LDH) and plasma free hemoglobin (PFH) pre-CPB were comparable for the CTRL and SS groups, respectively. LDH peri-CPB was 275+/-100 U/L versus 207+/-83 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 486+/-204 mg/L versus 351+/-176 mg/L for the CTRL and SS groups, respectively (P<0.05). LDH post CPB was 354+/-116 U/L versus 275+/-89 U/L for the CTRL and SS groups, respectively (P<0.05). PFH was 549+/-271 mg/L versus 460+/-254 mg/L for the CTRL and SS groups, respectively (P<0.05). Preoperative hematocrit (Hct) of 43+/-5% (CTRL) versus 37+/-5% (SS), and hemoglobin (Hb) of 141+/-16 g/L (CTRL) versus 122+/-17 g/L (SS) were significantly lower in the SS group. However, when normalized (N), the SS was capable of conserving Hct, Hb, and erythrocyte count perioperatively. Erythrocytes (N) were 59+/-5% (CTRL) versus 67+/-9% (SS); Hct (N) was 59+/-6% (CTRL) versus 68+/-9% (SS), and Hb (N) was 61+/-6% (CTRL) versus 70+/-10% (SS) (all P<0.05). This novel SS device evokes significantly lowered blood PFH and LDH values peri- and post CPB compared with the CTRL blood using a CS system. The SS may be a valuable alternative compared to traditional CS techniques.
Resumo:
BACKGROUND: Surgical correction of complete atrio-ventricular septal defect (AVSD) achieves satisfactory results with low morbidity and mortality, but may require reoperation. Our recent operative results at mid-term were followed-up. METHODS: From June 2000 to December 2007, 81 patients (Down syndrome; n=60), median age 4.0 months (range 0.7-118.6) and weight 4.7kg (range 2.2-33), underwent complete AVSD correction. Patch closure for the ventricular septal defect (VSD; n=69) and atrial septal defect (ASD; n=42) was performed with left atrio-ventricular valve (LAVV) cleft closure (n=76) and right atrio-ventricular valve (RAVV) repair (n=57). Mortality, morbidity, and indications for reoperation were retrospectively studied; the end point 'time to reoperation' was analyzed using Kaplan-Meier curves. Follow-up was complete except in two patients and spanned a median of 28 months (range 0.4-6.1 years). RESULTS: In-hospital mortality was 3.7% (n=3) and one late death occurred. Reoperation was required in 7/79 patients (8.9%) for LAVV insufficiency (n=4), for a residual ASD (n=1), for right atrio-ventricular valve insufficiency (n=1), and for subaortic stenosis (n=1). At last follow-up, no or only mild LAVV and RAVV insufficiency was present in 81.3% and 92.1% of patients, respectively, and 2/3 of patients were medication-free. Risk factors for reoperation were younger age (<3 months; p=0.001) and lower weight (<4kg; p=0.003), and a trend towards less and later reoperations in Down syndrome (p<0.2). CONCLUSIONS: Surgical correction of AVSD can be achieved with low mortality and need for reoperation, regardless of Down syndrome or not. Immediate postoperative moderate or more residual atrio-ventricular valve insufficiency will eventually require a reoperation, and could be anticipated in patients younger than 3 months and weighing <4kg.
Resumo:
L-Type Ca(2+) and K(ATP) Channels in Pacing-Induced Cardioprotection. AIMS: The L-type Ca(2+) channel, the sarcolemmal (sarcK(ATP)), and mitochondrial K(ATP) (mitoK(ATP)) channels are involved in myocardial preconditioning. We aimed at determining to what extent these channels can also participate in pacing-induced cardioprotection. METHODS: Hearts of 4-day-old chick embryos were paced in ovo during 12 hour using asynchronous intermittent ventricular stimulation at 110% of the intrinsic rate. Sham operated and paced hearts were then submitted in vitro to anoxia (30 minutes) and reoxygenation (60 minutes). These hearts were exposed to L-type Ca(2+) channel agonist Bay-K-8644 (BAY-K) or blocker verapamil, nonselective K(ATP) channel antagonist glibenclamide (GLIB), mitoK(ATP) channel agonist diazoxide (DIAZO), or antagonist 5-hydroxydecanoate. Electrocardiogram, electromechanical delay (EMD) reflecting excitation-contraction (E-C) coupling, and contractility were determined. RESULTS: Under normoxia, heart rate, QT duration, conduction, EMD, and ventricular shortening were similar in sham and paced hearts. During reoxygenation, arrhythmias ceased earlier and ventricular EMD recovered faster in paced hearts than in sham hearts. In sham hearts, BAY-K (but not verapamil), DIAZO (but not 5-hydroxydecanoate) or GLIB accelerated recovery of ventricular EMD, reproducing the pacing-induced protection. By contrast, none of these agents further ameliorated recovery of the paced hearts. CONCLUSION: The protective effect of chronic asynchronous pacing at near physiological rate on ventricular E-C coupling appears to be associated with subtle activation of L-type Ca(2+) channel, inhibition of sarcK(ATP) channel, and/or opening of mitoK(ATP) channel.
Resumo:
Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.
Resumo:
A 5-year-old previously healthy boy was admitted for abdominal pain and vomiting. Physical examination showed tachypnoe (32/min), hepatomegaly and painful palpation of the upper right abdominal quadrant. Laboratory tests were normal except for elevated ammonium (202mcmol/l). Chest X-ray was performed, showing cardiomegaly and interstitial edema. Transthoracic echocardiography revealed dilated left cavities and LV hypertrophy together with a diffuse hypokinesia and LVEF of 30-40%. Diuretics and ACE-inhibitors were introduced. At that time, the differential diagnosis for the DCM included myocarditis, congenital or genetic, metabolic or autoimmune disease. The next day, the boy underwent cardiac magnetic resonance (CMR) examination, showing a severe dilatation of the LV with an end-diastolic diameter of 50mm and a volume of 150ml. LVEF was 20% with diffuse LV hypokinesia (Fig. 1). No late enhancement was present after Gadolinium injection, ruling out myocarditis. Further laboratory metabolic analysis indicated severely decreased total and free carnitin levels and low renal carnitin reabsorption, corroborating the diagnosis of primary carnitin deficiency (PCD). Carnitin substitution was initiated. The clinical condition rapidly improved. No symptoms of heart failure were present anymore. A follow-up CMR performed 9 months later confirmed the recovery. LV end-diastolic volume decreased from 150ml to 66ml, LVEF increased from 20% to 55% (Fig. 2). Late enhancement was absent after Gadolinum injection (Fig. 3).Carnitin is required for the transport of fatty acids from the cytosol into mitochondria during lipid breakdown. 75% of carnitin is obtained from food, 25% is endogenously synthesized. PCD is an autosomal recessive disorder resulting from impairment of a transporter activity, caused by mutation of the SLC22A5 gene. Incidence is about 1 in 40'000 newborns. Diagnosis is usually made at age 1 to 7. Three forms of PCD are described. In the form associated with cardiomyopathy, the disease is progressive and patient die from heart failure if not treated. Substitution of L-Carnitin leads to a dramatic improvement of disease course.This case underlines the crucial role of etiologic diagnostics in this reversible form of DCM. Early diagnostics and therapy are critical for the prognosis of the patient. This is furthermore an example of a role played by CMR in the diagnostic work-up of heart failure and its follow-up under therapy.
Resumo:
BACKGROUND: Pulse wave velocity (PWV), an index of arterial wall stiffness, is modulated by blood pressure (BP). Whether heart rate (HR) is also a modulator of PWV is controversial. Recent research involving mainly patients with high aortic PWV have found either no change or a positive correlation between the two. Given that PWV is increasingly being measured in cardiovascular studies, the relationship between HR and PWV should be known in patients with preserved arterial wall elasticity. OBJECTIVE: The aim of this study was to evaluate the importance of HR as a determinant of the variability in PWV in patients with a low degree of atherosclerosis. DESIGN AND METHODS: Fourteen patients (five female, nine male; aged 68 +/- 8 years) were evaluated post pacemaker implantation due to sick sinus or carotid hypersensitivity syndromes. Carotid-femoral PWV was measured at rest and during atrial pacing at 80, 90 and 100 bpm (paced HR). Arterial femoral blood flow (AFBF) was measured by echodoppler. RESULTS: PWV increased from 6.2 +/- 1.5 m/s (mean +/- SD) during resting sinus rhythm (HR 62 +/- 8 bpm; mean +/- SD) to 6.8 +/- 1.0, 7.0 +/- 0.9, and 7.6 +/- 1.1 m/s at pacing rates of 80, 90 and 100 bpm, respectively (P < 0.0001). Systolic (SBP) and mean blood pressure (MBP) remained constant at all HR levels, whereas AFBF increased in a linear fashion. CONCLUSIONS: These results demonstrate that even in patients with a low degree of atherosclerosis, HR is a potential modulator of carotid-femoral PWV.
Resumo:
BACKGROUND: Subclinical hypothyroidism has been associated with systolic and diastolic cardiac dysfunction and an elevated cholesterol level, but data on cardiovascular outcomes and death are limited. METHODS: We studied 2730 men and women, aged 70 to 79 years, with baseline thyrotropin (TSH) measurements and 4-year follow-up data to determine whether subclinical hypothyroidism was associated with congestive heart failure (CHF), coronary heart disease, stroke, peripheral arterial disease, and cardiovascular-related and total mortality. After the exclusion of participants with abnormal thyroxine levels, subclinical hypothyroidism was defined as a TSH level of 4.5 mIU/L or greater, and was further classified according to TSH levels (4.5-6.9, 7.0-9.9, and > or = 10.0 mIU/L). RESULTS: Subclinical hypothyroidism was present in 338 (12.4%) of the participants. Compared with euthyroid participants, CHF events occurred more frequently among those with a TSH level of 7.0 mIU/L or greater (35.0 vs 16.5 per 1000 person-years; P = .006), but not among those with TSH levels between 4.5 and 6.9 mIU/L. In multivariate analyses, the risk of CHF was higher among those with high TSH levels (TSH of 7.0-9.9 mIU/L: hazard ratio, 2.58 [95% confidence interval, 1.19-5.60]; and TSH of > or = 10.0 mIU/L: hazard ratio, 3.26 [95% confidence interval, 1.37-7.77]). Among the 2555 participants without CHF at baseline, the hazard ratio for incident CHF events was 2.33 (95% confidence interval, 1.10-4.96; P = .03) in those with a TSH of 7.0 mIU/L or greater. Subclinical hypothyroidism was not associated with increased risk for coronary heart disease, stroke, peripheral arterial disease, or cardiovascular-related or total mortality. CONCLUSIONS: Subclinical hypothyroidism is associated with an increased risk of CHF among older adults with a TSH level of 7.0 mIU/L or greater, but not with other cardiovascular events and mortality. Further investigation is warranted to assess whether subclinical hypothyroidism causes or worsens preexisting heart failure.
Resumo:
Loss of T-tubules (TT), sarcolemmal invaginations of cardiomyocytes (CMs), was recently identified as a general heart failure (HF) hallmark. However, whether TT per se or the overall sarcolemma is altered during HF process is still unknown. In this study, we directly examined sarcolemmal surface topography and physical properties using Atomic Force Microscopy (AFM) in living CMs from healthy and failing mice hearts. We confirmed the presence of highly organized crests and hollows along myofilaments in isolated healthy CMs. Sarcolemma topography was tightly correlated with elasticity, with crests stiffer than hollows and related to the presence of few packed subsarcolemmal mitochondria (SSM) as evidenced by electron microscopy. Three days after myocardial infarction (MI), CMs already exhibit an overall sarcolemma disorganization with general loss of crests topography thus becoming smooth and correlating with a decreased elasticity while interfibrillar mitochondria (IFM), myofilaments alignment and TT network were unaltered. End-stage post-ischemic condition (15days post-MI) exacerbates overall sarcolemma disorganization with, in addition to general loss of crest/hollow periodicity, a significant increase of cell surface stiffness. Strikingly, electron microscopy revealed the total depletion of SSM while some IFM heaps could be visualized beneath the membrane. Accordingly, mitochondrial Ca(2+) studies showed a heterogeneous pattern between SSM and IFM in healthy CMs which disappeared in HF. In vitro, formamide-induced sarcolemmal stress on healthy CMs phenocopied post-ischemic kinetics abnormalities and revealed initial SSM death and crest/hollow disorganization followed by IFM later disarray which moved toward the cell surface and structured heaps correlating with TT loss. This study demonstrates that the loss of crest/hollow organization of CM surface in HF occurs early and precedes disruption of the TT network. It also highlights a general stiffness increased of the CM surface most likely related to atypical IFM heaps while SSM died during HF process. Overall, these results indicate that initial sarcolemmal stress leading to SSM death could underlie subsequent TT disarray and HF setting.
Resumo:
The increase in resting energy expenditure (REE) reported in patients with cystic fibrosis (CF) does not necessarily imply an increase in total energy expenditure (TEE). In this study REE was assessed with open-circuit indirect calorimetry, and free-living 24-hour TEE with the heart rate method. Thirteen patients with CF, aged 8 to 24 years, with adequate nutritional status and moderately decreased pulmonary function, were studied. They were compared with 13 healthy control subjects matched for gender, age, height, and nutritional status. Resting energy expenditure was higher in patients with CF (1512 +/- 88 kcal/day) than in control subjects (1339 +/- 76 kcal/day; p less than 0.01), whereas free-living 24-hour TEE (2345 +/- 127 kcal/day and 2358 +/- 256 kcal/day, respectively) and net mechanical work efficiency of walking on a treadmill (20.4 +/- 0.7% and 19.8 +/- 0.6%, respectively) were similar. Respiratory quotient was higher in patients with CF than in control subjects at rest (0.834 +/- 0.009 vs 0.797 +/- 0.008; p less than 0.05), and tended to remain so during physical exercise, indicating a higher contribution of carbohydrate oxidation to energy expenditure. We conclude that in free living conditions, patients with CF can compensate for their increase in REE by a reduction in spontaneous physical activities or other yet undefined mechanisms.
Resumo:
La teràpia suplementària de ferro millora la capacitat d’exercici i la qualitat de vida en malalts amb una cardiopatia congènita cianòtica i/ o síndrome d’Eisenmenger El dèficit de ferro és una troballa comú en la cardiopatia congènita cianòtica, i pot ser la causa d’una reducció en la capacitat d’exercici. Actualment, està indicada la reposició dels dipòsits de ferro en aquest grup de malalts, éssent les evidències científiques escasses. En el present treball investiguem la seguretat i eficàcia del tractament amb ferro en malalts amb una cardiopatia congènita cianòtica. Per tal motiu, vint-i-cinc malalts amb una cardiopatia congenita cianòtica i dèficit de ferro van ser inclosos de forma prospectiva entre Agost del 2008 i Gener del 2009. El tractament utilitzat fou fumarat ferròs oral, fins a una dosi màxima de 200 mg tres vegades al dia. En l’anàlisi basal i als tres mesos de seguiment es va utilitzar el test de qualitat de vida “CAMPHOR”, el test de la marxa dels 6 minuts i la prova d’esforç amb consum d’oxigen. L’edat mitja fou 39.9+/-10.9 anys, 80% dones. Catorze malalts tenien la síndrome d’Eisenmenger, sis una malaltia cianòtica complexa i cinc circulació de Fontan. Cap d’ells va haver d'interrompre el tractament degut a efectes adversos. Després de tres mesos de tractament, l’hemoglobina (19.0+/-2.9g/dL a 20.4+/-2.7g/dL, p&0.001), ferritina (13.3+/-4.7mug/L a 54.1+/-24.2mug/L, p&0.001) i saturació de transferrina (17.8+/-9.6% a 34.8+/-23.4%, p&0.001) van augmentar significativament. També hi va haver una millora significativa en la puntuació del test de qualitat de vida (20.7+/-10.9 a 16.2+/-10.4, p=0.001) i el test de la marxa (371.7+/-84.7m a 402.8.0+/-74.9m, p=0.001). No es van evidenciar canvis significatius en els valors de consum d’oxigen (40.7+/-9.2% a 43.8+/-12.4%, p=0.15). En definitiva, la teràpia suplementària amb ferro en els malats amb una cardiopatia congènita cianòtica i dèficit de ferro és segura i millora la qualitat de vida i la capacitat funcional. En aquest grup de malalts, per tant, és aconsellable identificar el dèficit de ferro i restaurar-ne els seus dipòsits.
Resumo:
BACKGROUND: Half of the patients with end-stage heart failure suffer from persistent atrial fibrillation (AF). Atrial kick (AK) accounts for 10-15% of the ejection fraction. A device restoring AK should significantly improve cardiac output (CO) and possibly delay ventricular assist device (VAD) implantation. This study has been designed to assess the mechanical effects of a motorless pump on the right chambers of the heart in an animal model. METHODS: Atripump is a dome-shaped biometal actuator electrically driven by a pacemaker-like control unit. In eight sheep, the device was sutured onto the right atrium (RA). AF was simulated with rapid atrial pacing. RA ejection fraction (EF) was assessed with intracardiac ultrasound (ICUS) in baseline, AF and assisted-AF status. In two animals, the pump was left in place for 4 weeks and then explanted. Histology examination was carried out. The mean values for single measurement per animal with +/-SD were analysed. RESULTS: The contraction rate of the device was 60 per min. RA EF was 41% in baseline, 7% in AF and 21% in assisted-AF conditions. CO was 7+/-0.5 l min(-1) in baseline, 6.2+/-0.5 l min(-1) in AF and 6.7+/-0.5 l min(-1) in assisted-AF status (p<0.01). Histology of the atrium in the chronic group showed chronic tissue inflammation and no sign of tissue necrosis. CONCLUSIONS: The artificial muscle restores the AK and improves CO. In patients with end-stage cardiac failure and permanent AF, if implanted on both sides, it would improve CO and possibly delay or even avoid complex surgical treatment such as VAD implantation.
Resumo:
Total energy expenditure (TEE) and patterns of activity were measured by means of a heart rate (HR)-monitoring method in a group of 8-10-year-old children including 13 obese children (weight, 46 +/- 10 kg; fat mass: 32 +/- 9%) and 16 nonobese children (weight, 31 +/- 5 kg; fat mass, 18 +/- 5%). Time for sleeping was not statistically different in the two groups of children (596 +/- 33 vs. 582 +/- 43 min; p = NS). Obese children spent more time doing sedentary activities (400 +/- 129 vs. 295 +/- 127 min; p < 0.05) and less time in nonsedentary activities (449 +/- 126 vs. 563 +/- 135 min; p < 0.05) than nonobese children. Time spent in moderate or vigorous activity-i.e., time spent at a HR between 50% of the maximal O2 uptake (peak VO2) and 70% peak VO2 (moderate) and at a HR > or = 70% peak VO2 (vigorous)-was not statistically different in obese and nonobese children (88 +/- 69 vs. 52 +/- 35 min and 20 +/- 21 vs. 16 +/- 13 min, respectively; p = NS). TEE was significantly higher in the obese group than in the nonobese group (9.46 +/- 1.40 vs. 7.51 +/- 1.67 MJ/day; p < 0.01). The energy expenditure for physical activity (plus thermogenesis) was significantly higher in the obese children (3.98 +/- 1.30 vs. 2.94 +/- 1.39 MJ/day; p < 0.05). The proportion of TEE daily devoted to physical activity (plus thermogenesis) was not significantly different in the two groups, as shown by the ratio between TEE and the postabsorptive metabolic rate (PMR): 1.72 +/- 0.25 obese vs 1.61 +/- 0.28 non-obese. In conclusion, in free-living conditions obese children have a higher TEE than do nonobese children, despite the greater time devoted to sedentary activities. The higher energy cost to perform weight-bearing activities as well as the higher absolute PMR of obese children help explain this apparent paradox.
Resumo:
CONTEXT: Infection of implantable cardiac devices is an emerging disease with significant morbidity, mortality, and health care costs. OBJECTIVES: To describe the clinical characteristics and outcome of cardiac device infective endocarditis (CDIE) with attention to its health care association and to evaluate the association between device removal during index hospitalization and outcome. DESIGN, SETTING, AND PATIENTS: Prospective cohort study using data from the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), conducted June 2000 through August 2006 in 61 centers in 28 countries. Patients were hospitalized adults with definite endocarditis as defined by modified Duke endocarditis criteria. MAIN OUTCOME MEASURES: In-hospital and 1-year mortality. RESULTS: CDIE was diagnosed in 177 (6.4% [95% CI, 5.5%-7.4%]) of a total cohort of 2760 patients with definite infective endocarditis. The clinical profile of CDIE included advanced patient age (median, 71.2 years [interquartile range, 59.8-77.6]); causation by staphylococci (62 [35.0% {95% CI, 28.0%-42.5%}] Staphylococcus aureus and 56 [31.6% {95% CI, 24.9%-39.0%}] coagulase-negative staphylococci); and a high prevalence of health care-associated infection (81 [45.8% {95% CI, 38.3%-53.4%}]). There was coexisting valve involvement in 66 (37.3% [95% CI, 30.2%-44.9%]) patients, predominantly tricuspid valve infection (43/177 [24.3%]), with associated higher mortality. In-hospital and 1-year mortality rates were 14.7% (26/177 [95% CI, 9.8%-20.8%]) and 23.2% (41/177 [95% CI, 17.2%-30.1%]), respectively. Proportional hazards regression analysis showed a survival benefit at 1 year for device removal during the initial hospitalization (28/141 patients [19.9%] who underwent device removal during the index hospitalization had died at 1 year, vs 13/34 [38.2%] who did not undergo device removal; hazard ratio, 0.42 [95% CI, 0.22-0.82]). CONCLUSIONS: Among patients with CDIE, the rate of concomitant valve infection is high, as is mortality, particularly if there is valve involvement. Early device removal is associated with improved survival at 1 year.
Resumo:
INTRODUCTION: Persistent atrial fibrillation (AF) ablation may lead to partial disconnection of the coronary sinus (CS). As a result, disparate activation sequences of the local CS versus contiguous left atrium (LA) may be observed during atrial tachycardia (AT). We aimed to evaluate the prevalence of this phenomenon and its impact on activation mapping. METHODS: AT occurring after persistent AF ablation were investigated in 74 consecutive patients. Partial CS disconnection during AT was suspected when double potentials with disparate activation sequences were observed on the CS catheter. Endocardial mapping facing CS bipoles was performed to differentiate LA far-field from local CS potentials. RESULTS: A total of 149 ATs were observed. Disparate LA-CS activations were apparent in 20 ATs after magnifying the recording scale (13%). The most common pattern (90%) was distal to proximal endocardial LA activation against proximal to distal CS activation, the latter involving the whole CS or its distal part. Perimitral macroreentry was more common when disparate LA-CS activations were observed (67% vs 29%; P = 0.002). Partial CS disconnection also resulted in "pseudo" mitral isthmus (MI) block during LA appendage pacing in 20% of patients as local CS activation was proximal to distal despite distal to proximal activation of the contiguous LA. CONCLUSION: Careful analysis of CS recordings during AT following persistent AF ablation often reveals disparate patterns of activation. Recognizing when endocardial LA activation occurs in the opposite direction to the more obvious local CS signals is critical to avoid misleading interpretations during mapping of AT and evaluation of MI block.