976 resultados para Synchrotron radiation topography


Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present multifrequency Very Large Array (VLA) observations of two giant quasars, 0437-244 and 1025-229, from the Molonglo Complete Sample. These sources have well-defined FR II radio structure, possible one-sided jets, no significant depolarization between 1365 and 4935 MHz and low rotation measure (\ RM \ < 20 rad m(-2)). The giant sources are defined to be those with overall projected size greater than or equal to 1 Mpc. We have compiled a sample of about 50 known giant radio sources from the literature, and have compared some of their properties with a complete sample of 3CR radio sources of smaller sizes to investigate the evolution of giant sources, and test their consistency with the unified scheme for radio galaxies and quasars. We find an inverse correlation between the degree of core prominence and total radio luminosity, and show that the giant radio sources have similar core strengths to smaller sources of similar total luminosity. Hence their large sizes are unlikely to be caused by stronger nuclear activity. The degree of collinearity of the giant sources is also similar to that of the sample of smaller sources. The luminosity-size diagram shows that the giant sources are less luminous than our sample of smaller sized 3CR sources, consistent with evolutionary scenarios in which the giants have evolved from the smaller sources, losing energy as they expand to these large dimensions. For the smaller sources, radiative losses resulting from synchrotron radiation are more significant while for the giant sources the equipartition magnetic fields are smaller and inverse Compton lass owing to microwave background radiation is the dominant process. The radio properties of the giant radio galaxies and quasars are consistent with the unified scheme.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electroluminescent zinc sulfide doped with copper and chloride (ZnS:Cu, Cl) powder was heated to 400°C and rapidly quenched to room temperature. Comparison between the quenched and non-quenched phosphors using synchrotron radiation X-ray powder diffraction (XRPD) (λ = 0.828692 Å) and X-ray absorption spectroscopy (XAS) was made. XRPD shows that the expected highly faulted structure is observed with excellent resolution out to 150° 2θ (or to (12 2 2) of the sphalerite phase). The quenched sample compared to the unheated sample shows a large change in peak ratios between 46.7° and 46.9°, which is thought to correspond to the wurtzite (0 0 6), (0 3 2) and sphalerite (3 3 3)/(5 1 1) peaks. Hence, a large proportion of this sphalerite diffraction is lost from the material upon rapid quenching, but not when the material is allowed to cool slowly. The Zn K-edge XAS data indicate that the crystalline structures are indistinguishable using this technique, but do give an indication that the electronic structure has altered due to changing intensity of the white line. It is noted that the blue electroluminescence (EL) emission bands are lost upon quenching: however, a large amount of total EL emission intensity is also removed, which is consistent with our findings. We report the XRPD of a working alternating-current electroluminescence device in the synchrotron X-ray beam, which exhibits a new diffraction pattern when the device is powered in an AC field even though the phosphor is fixed in the binder. Significantly, only a few crystals are required to yield the diffraction data because of the high flux X-ray source. These in panel data show multiple sharp diffraction lines spread out under the region, where capillary data show broad diffraction intensity indicating that the phosphor powder is comprised of unique crystals, each having different structures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mycobacterium tuberculosis has multiple sigma factors which enable the bacterium to reprogram its transcriptional machinery under diverse environmental conditions. sigma(J), an extracytoplasmic function sigma factor, is upregulated in late stationary phase cultures and during human macrophage infection. sigma(J) governs the cellular response to hydrogen peroxide-mediated oxidative stress. sigma(J) differs from other canonical sigma factors owing to the presence of a SnoaL_2 domain at the C-terminus. sigma(J) crystals belonged to the tetragonal space group I422, with unit-cell parameters a = b = 133.85, c = 75.08 angstrom. Diffraction data were collected to 2.16 angstrom resolution on the BM14 beamline at the European Synchrotron Radiation Facility (ESRF).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The electronic structure of the (La0.8Sr0.2)(0.98)Mn1-xCrxO3 model series (x = 0, 0.05, or 0.1) was measured using soft X-ray synchrotron radiation at room and elevated temperature. O K-edge near-edge X-ray absorption fine structure (NEXAFS) spectra showed that low-level chromium substitution of (La, Sr)MnO3 resulted in lowered hybridisation between O 2p orbitals and M 3d and M 4sp valance orbitals. Mn L-3-edge resonant photoemission spectroscopy measurements indicated lowered Mn 3d-O 2p hybridisation with chromium substitution. Deconvolution of O K-edge NEXAFS spectra took into account the effects of exchange and crystal field splitting and included a novel approach whereby the pre-peak region was described using the nominally filled t(2g) up arrow state. 10% chromium substitution resulted in a 0.17 eV lowering in the energy of the t(2g) up arrow state, which appears to provide an explanation for the 0.15 eV rise in activation energy for the oxygen reduction reaction, while decreased overlap between hybrid O 2p-Mn 3d states was in qualitative agreement with lowered electronic conductivity. An orbital-level understanding of the thermodynamically predicted solid oxide fuel cell cathode poisoning mechanism involving low-level chromium substitution on the B-site of (La, Sr)MnO3 is presented. (C) 2015 AIP Publishing LLC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Crystallization, melting and structural evolution upon crystallization in Nd60Al10Fe20Co10 bulk metallic glass (BMG) are in situ investigated by x-ray diffraction with synchrotron radiation under high pressure. It is found that the crystallization is pressure promoted, while themelting is inhibited. The crystallization and melting process are also changed under high pressure. The features of the crystallization and melting under high pressure are discussed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

研究了逆流相对论电子与激光脉冲相互作用获得激光同步辐射的频率上移、微分散射截面等特性.发现逆流相对论电子与短脉冲激光相互作用,可以获得阿秒X射线辐射脉冲.短脉冲激光条件下得到的后向散射光的频率上移与长脉冲激光条件下得到的后向散射光的频率上移是完全一致的,同时发现随着入射电子初始能量的增加,散射光的准直性越来越好,后向散射光脉冲的脉宽越来越短.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

介绍了硬X射线(类同轴)相位衬度成像的工作原理及其实验研究结果。X射线波长为0.08860nm,样品为未经任何处理的飞蛾,记录介质为X射线胶片。胶片经处理以后,用光学显微镜读出,可以看出样品的许多细节,尤其在折射率突变处。而同样条件下基于吸收衬度机制的硬X射线吸收成像,由于是弱吸收样品.没有观察到任何图像。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Linear Thomson scattering by a relativistic electron of a short pulse laser has been investigated by computer simulation. Under a laser field with a pulse of 33.3-fs full-width at half-maximum, and the initial energy of an electron of gamma(0) = 10, the motion of the electron is relativistic and generates an ultrashort radiation of 76-as with a photon wave length of 2.5-nm in the backward scattering. The radiation under a high relativistic energy electron has better characteristic than under a low relativistic energy electron in terms of the pulse width and the angular distribution. (c) 2005 Elsevier GrnbH. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

X-ray phase imaging with illumination by a partially coherent source with a setup similar to in-line holography is considered. Using the optical transform function, we consider the effects of partial coherence on this x-ray phase imaging for a weak phase object. The optimal contrast and the resolution of phase imaging are analyzed. As the coherence decreases, the imaging contrast and the optimal contrast frequency decrease, and the resolution degrades. It is shown that this contrast-enhanced phase-imaging method can be regarded as a linear bandpass filter and that the bandwidth and the image contrast are changeable. The frequency property of the imaging system can be improved if an incoherent x-ray source with the proper shape is used. (C) 1999 Optical Society of America.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis has two basic themes: the investigation of new experiments which can be used to test relativistic gravity, and the investigation of new technologies and new experimental techniques which can be applied to make gravitational wave astronomy a reality.

Advancing technology will soon make possible a new class of gravitation experiments: pure laboratory experiments with laboratory sources of non-Newtonian gravity and laboratory detectors. The key advance in techno1ogy is the development of resonant sensing systems with very low levels of dissipation. Chapter 1 considers three such systems (torque balances, dielectric monocrystals, and superconducting microwave resonators), and it proposes eight laboratory experiments which use these systems as detectors. For each experiment it describes the dominant sources of noise and the technology required.

The coupled electro-mechanical system consisting of a microwave cavity and its walls can serve as a gravitational radiation detector. A gravitational wave interacts with the walls, and the resulting motion induces transitions from a highly excited cavity mode to a nearly unexcited mode. Chapter 2 describes briefly a formalism for analyzing such a detector, and it proposes a particular design.

The monitoring of a quantum mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. Chapter 3 reviews the standard techniques for monitoring the oscillator; and it introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator.

The standard method for monitoring the oscillator is the "amplitude- and-phase" method (position or momentum transducer with output fed through a linear amplifier). The accuracy obtainable by this method is limited by the uncertainty principle. To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well-known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak force, but which cannot provide good accuracy in determining its precise time-dependence. Chapter 3 considers extensively a new type of quantum nondemolition measurement - a "back-action-evading" measurement of the real part X1 (or the imaginary part X2) of the oscillator's complex amplitude. In principle X1 can be measured arbitrarily quickly and arbitrarily accurately, and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force.

Chapter 3 describes explicit gedanken experiments which demonstrate that X1 can be measured arbitrarily quickly and arbitrarily accurately, it considers approximate back-action-evading measurements, and it develops a theory of quantum nondemolition measurement for arbitrary quantum mechanical systems.

In Rosen's "bimetric" theory of gravity the (local) speed of gravitational radiation vg is determined by the combined effects of cosmological boundary values and nearby concentrations of matter. It is possible for vg to be less than the speed of light. Chapter 4 shows that emission of gravitational radiation prevents particles of nonzero rest mass from exceeding the speed of gravitational radiation. Observations of relativistic particles place limits on vg and the cosmological boundary values today, and observations of synchrotron radiation from compact radio sources place limits on the cosmological boundary values in the past.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We have grown an atom-thin, ordered, two-dimensional multi-phase film in situ through germanium molecular beam epitaxy using a gold (111) surface as a substrate. Its growth is similar to the formation of silicene layers on silver (111) templates. One of the phases, forming large domains, as observed in scanning tunneling microscopy, shows a clear, nearly flat, honeycomb structure. Thanks to thorough synchrotron radiation core-level spectroscopy measurements and advanced density functional theory calculations we can identify it as a root 3 x root 3 R(30 degrees) germanene layer in conjunction with a root 7 x root 7 R(19.1 degrees) Au(111) supercell, presenting compelling evidence of the synthesis of the germanium-based cousin of graphene on gold.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Neste trabalho utilizou-se a técnica fluorescência de raios X usando radiação síncrotron (SR-TXRF) para estudar, quantitativamente, o transporte de cloro, potássio e cálcio na hemolinfa, urina e túbulos de Malpighi (TM) em ninfas de quinto estágio do Rhodnius prolixus (R. prolixus), considerando a excreção destes elementos em diferentes dias após o repasto sanguíneo. R. prolixus é um dos principais vetores do Trypanosoma cruzi, agente causador da doença de Chagas. R. prolixus fornece um sistema modelo particularmente útil porque seus TMs tanto secretam quanto reabsorvem íons a taxas elevadas. Os TMs filtram a hemolinfa e secretam um líquido que é muitas vezes comparado com a urina primária em vertebrados. Os resultados obtidos mostram que a concentração de potássio na urina é substancialmente maior do que na hemolinfa. A concentração de cloro na hemolinfa é menor do que na urina, mas a diferença não é tão marcada como no caso do potássio. No caso do Rhodnius é razoável interpretar a elevada concentração de potássio na urina como adaptativo para o problema de excreção imediato do inseto. A concentração de cálcio nos TMs é substancialmente maior em comparação com os valores encontrados na hemolinfa e urina. Este resultado mostra que o cálcio é retido no corpo do R. prolixus e pouco eliminado. Os resultados obtidos estão coerentes com a literatura. Avaliou-se também o efeito no transporte de Cl, K e Ca após um repasto de sangue de coelho contaminado com HgCl2 de modo a avaliar o efeito da presença deste metal tóxico no balanço iônico nos fluidos de excreção urina e hemolinfa e também pelo principal órgão de transporte, os túbulos de Malpighi. As excreções de Cl e K pela urina são afetadas pela ingestão. Este resultado é esperado levando-se em consideração a ingestão de excesso de Cl através do HgCl2. O transporte de Cl, K e Ca na hemolinfa do Rhodnius prolixus não é afetada pela ingestão de HgCl2. Nos túbulos de Malpighi, as altas concentrações de Ca obtidas foram comparáveis àquelas encontradas nos insetos controle. Pode-se concluir que SR-TXRF é um método muito promissor para análises diretas, rápidas e confiáveis para a quantificação simultânea de elementos envolvidos na regulação do transporte e em todo o sistema excretor de insetos. Além disso, o estudo do transporte e a excreção de elementos no inseto Rhodnius prolixus abrem oportunidade para a maior compreensão de efeitos da poluição em espécies de invertebrados.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

用磁控溅射法制备了顶层分别是Mo膜层和Si膜层的两个系列的Mo/Si多层膜,它们的周期厚度相同但是膜层数各不相同。Mo/Si多层膜的周期厚度和界面粗糙度由小角X射线衍射(SAXRD)曲线拟和得到。用原子力显微镜测量了Mo/Si多层膜的表面粗糙度。在国家同步辐射实验室测量了Mo/Si多层膜的软X射线反射率。通过理论和试验研究,发现Mo/Si多层膜的软X射线反射率主要由周期数和界面粗糙度决定,表面粗糙度对Mo/Si多层膜的软X射线反射率影响较小。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

用磁控溅射法分别制备了以Mo膜层和Si膜层为顶层的Mo/Si多层膜系列,利用小角X射线衍射确定了各多层膜的周期厚度。以不同周期数的Mo/Si多层膜的新鲜表面近似等同于同一多层膜的内界面,通过原子力显微镜研究了多层膜界面粗糙度随膜层数的变化规律。并在国家同步辐射实验室测量了各多层膜的软X射线反射率。研究表明:随着膜层数的增加,Mo膜层和Si膜层的界面粗糙度先减小后增加然后再减小,多层膜的峰值反射率先增加后减小。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A urolitíase é um problema de escala mundial, que ocorre em todas as regiões, culturas e grupos raciais. A incidência desta doença vem aumentando ao redor do mundo e dados mostram que no Brasil estima-se que são afetados 5% da população com uma taxa de recorrência de 2,5%. Conhecer a composição mineral e estrutura interna dos cálculos é um passo importante para tentar entender melhor a fisiopatologia desta doença. Quatro cálculos urinários infecciosos, íntegros de grande volume (diâmetro maior que 20 mm), sendo dois provenientes da bexiga e dois de rins, obtidos cirurgicamente no setor de urologia do Hospital Universitário Pedro Ernesto (HUPE/UERJ) foram analisados usando microtomografia (μCT) e difração de raios X por policristais (DRXP). As imagens microtomográficas foram obtidas usando tubo de raios X microfoco na estação TomoLab e radiação síncrotron (SR-μCT) na linha de Física Médica, ambos no Laboratório Síncrotron Elettra, Trieste, Itália. As medidas de DRXP foram realizadas na linha de Difração de Raios X do Laboratório Nacional de luz Síncrotron, Campinas, Brasil. Para os cálculos de bexiga foram encontradas quatro fases cristalinas: estruvita (STV), oxalato mono (COM) e dihidratado (COD) e hidroxiapatita (HAp). Nos cálculos renais foram encontrados STV e HAp, sendo predominante a primeira fase cristalina. A quantidade de material amorfo (não-cristalino) foi maior que 60% da composição das amostras. A técnica convencional utilizada foi eficaz para análise dos cálculos urinários inteiros e possibilitou a visualização de estruturas internas sem interferência de procedimentos prévios de preparação da amostra. As análises de DRXP com fonte síncrotron aliadas ao método Rietveld foram determinantes para identificação e quantificação dos minerais presentes nas varias camadas das amostras. Pode-se constatar a complementaridade entre a μCT e a DRXP para caracterização microestrutural e mineralógica de cálculos urinários humanos.