994 resultados para Surface defect


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We study the orientational ordering on the surface of a sphere using Monte Carlo and Brownian dynamics simulations of rods interacting with an anisotropic potential. We restrict the orientations to the local tangent plane of the spherical surface and fix the position of each rod to be at a discrete point on the spherical surface. On the surface of a sphere, orientational ordering cannot be perfectly nematic due to the inevitable presence of defects. We find that the ground state of four +1/2 point defects is stable across a broad range of temperatures. We investigate the transition from disordered to ordered phase by decreasing the temperature and find a very smooth transition. We use fluctuations of the local directors to estimate the Frank elastic constant on the surface of a sphere and compare it to the planar case. We observe subdiffusive behavior in the mean square displacement of the defect cores and estimate their diffusion constants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is concerned with the problem of automatic inspection of metallic surface using machine vision. An experimental system has been developed to take images of external metallic surfaces and an intelligent approach based on morphology and genetic algorithms is proposed to detect structural defects on bumpy metallic surfaces. The approach employs genetic algorithms to automatically learn morphology processing parameters such as structuring elements and defect segmentation threshold. This paper describes the detailed procedures which include encoding scheme, genetic operation and evaluation function.

The proposed method has been implemented and tested on a number of metallic surfaces. The results suggest that the method can provide an accurate identification to the defects and can be developed into a viable commercial visual inspection system.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a novel approach of visual inspection for texture surface defects. It is based on the measure of texture energy acquired by a kind if high performance 2D detection mask, which is learned by genetic algorithms. Experimental results of texture defect inspection on textile images are presented to illustrate the merit and feasibility of the proposed method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A microstructural characterisation of the family of N-methyl-N-alkylpyrrolidinium tetrafluoroborate organic salts was carried out by observation of powder surface morphologies with the aim of extending the microstructure-property correlation. Inherent difficulties limiting extensive studies of organic solids by SEM, including volatility under vacuum, charging due to electron beam irradiation, and air-sensitivity were overcome with the use of a Field Emission SEM and cryostage attachment. This technique, providing considerable improvements in image quality at low accelerating voltages, enabled direct observation of complex microstructural features in samples exhibiting high temperature plastic crystalline phases (N,N-dimethylpyrrolidinium tetrafluoroborate [P11BF4]; N-methyl-N-ethylpyrrolidinium tetrafluoroborate [P12BF4]; N-methyl-N-propylpyrrolidinium tetrafluoroborate [P13BF4]). Extensive lattice imperfections including grain boundaries, slip planes and dislocation pits were observed within particles of approximately 200 mgrm diameter. The N-methyl-N-butylpyrrolidinium tetrafluoroborate (P14BF4) sample in this series revealed columnar single crystals with high aspect ratios. The origin of plastic flow properties is discussed using single crystal and polycrystalline slip observations and a relationship proposed between defect characteristics and transport properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the bone repair process in the maxillary sinus in monkeys treated with high-density porous polyethylene (Medpor)Methods: Four capuchin monkeys (Cebus apella) were submitted to bilateral horizontal osteotomies in the anterior wall of the maxillary sinus and divided into 2 groups: control group, left side with no implants, and porous polyethylene group, right side with Medpor. After a period of 145 days after implant placement, the maxillae were removed for histologic and histometric analyses.Results: Bone repair in osteotomized areas took place by connective tissue in 58.5% and 58.7% in the control group and the porous polyethylene group, respectively. In the contact surface with Medpor, bone repair occurred in 41.3%.Conclusions: Medpor was not reabsorbed within the period of this study and allowed bone repair surrounding it. The porous polyethylene constitutes a feasible alternative for bone defect reconstruction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present work we investigate the behavior of a vortex in a long superconducting cylinder near to a columnar defect at the center. The derivations of the local magnetic field distribution and the Gibbs free energy will be carried out for a cylinder and a cavity of arbitrary sizes. From the general expressions, it is considered two particular limits: one in which the radius of the cavity is very small but the radius of the superconducting cylinder is kept finite; and one in which the radius of the superconducting cylinder is taken very large (infinite) but the radius of the cavity is kept finite. In both cases the maximum number of vortices which are allowed in the cavity is determined. In addition, the surface barrier field for flux entrance into the cavity is calculated. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the exception of the cleft lip, developmental defects (DD) of the lip are rare. The upper lip originates from the ectomesenchyme and is formed by the merging of the nasal medial and lateral processes with the maxillary process. Disturbances during this formation period can cause DD with functional and/or esthetic repercussions. We present a case of DD of the upper lip in a patient with a history of progressive growth of the left lateral portion of the upper lip that occurred from the time of birth until the age of 22 years. Clinical examination revealed hypertrophy of the area from the left philtral columns to the left commissure of the lip, extending the portion of the surface mucosa creating a flaccid and asymptomatic tissue mass. All other buccal structures appeared to be within normal limits and without any evidence of defects or deformities. In the surgical planning we decided to carry out corrective surgery in two phases. The first phase accomplished a conservative excision of the total abnormal labial tissue mass with a CO2 laser radiation (5 W in continuous mode, bunch diameter φ = 0.6 mm with a power density of 768 W/cm2 and fluency of 0.231 J/cm2) being careful to preserve the vermilion portion of the lip. Postsurgical clinical evaluations were done every three days until the skin sutures were removed and then every seven days until two months post surgery. While the entire mass of excessive tissue could not be completely removed, the removal of the excessive mucosal tissue produced a very good outcome relative to lip function, with a good esthetic result without scarring, and good tissue mobility. The results showed that the CO2 laser is an extremely useful instrument that can provide excellent control of the surgical field and allow for healing that produces excellent functional and esthetic results. © 2005 Taylor & Francis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Visible photoluminescence was generated in standard soda-lime-silica glass powder, mechanically milled in a high-energy attrition mill. The broad emission band maximum shows a linear dependence on the exciting wavelength, suggesting the possibility to tune the PL emission. The photoluminescence was attributed to defect generation related to unsatisfied chemical bonds due to the high surface area. Raman scattering and ultraviolet-visible optical reflectance measurements corroborate this assertion. Transmission electron microscopy measurements indicate that the powder is composed by nanocrystallites with about 10-20 nanometers immersed in an amorphous media.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polystyrene latex particles modified at the surface with different hydrophilic functional groups were prepared by miniemulsion polymerization and applied to control the crystallization of zinc oxide in aqueous medium. The effects of both latex structure and concentration on the crystal growth, morphology, crystalline structure, and properties of the resulting zinc oxide were analyzed. Depending on the latex additive used, micro- and submicrosized crystals with a broad variety of morphologies were obtained. Among the studied latexes, the carboxyl-derived particles were shown to be a convenient system for further quantitative investigations. In this case, as the additive concentration increases, the aspect ratio of the crystals decreases systematically. Latex particles are assumed to adsorb preferentially onto the fast growing {001} faces of ZnO, interacting with the growth centers and reducing the growth rate in [001]. When zinc oxide is precipitated in the presence of latex, the polymer particles become incorporated into the growing crystals and polymer–inorganic hybrid materials are obtained. These materials are composed of an inorganic and largely undisturbed crystalline matrix in which organic latex particles are embedded. Increasing amounts of latex become incorporated into the growing crystals at increasing overall concentration in the crystallizing system. Photoluminescence (PL) spectra were measured to obtain information on defect centers. Emission spectra of all samples showed a narrow UV peak and a broad band in the green-yellow spectral region. The former emission is attributed to exciton recombination, whereas the latter seems to be related with deep-level donors. Latex appears to be a quencher of the visible emission of zinc oxide. Thus, compared to pure zincite, ZnO–latex hybrid materials show a significantly lower PL intensity in the visible range of the spectrum. Under continuous photoexcitation, a noticeable dynamic behavior of the PL is observed, which can be related to a photodesorption of adsorbed oxygen. These surface-adsorbed oxygen species seem to play a crucial role for the optical properties of the materials and may mediate the tunneling of electrons from the conduction band to preexisting deep-level traps, probably related to intrinsic defects (oxygen vacancies or interstitial zinc). The polymer particles can block the sites where oxygen adsorbs, and the disappearance of the “electron-shuttle” species leads to the observed quenching of the visible emission. Electron paramagnetic resonance (EPR) provided additional information about crystal defects with unpaired electrons. Spectra of all samples exhibit a single signal at g ≈ 1.96, typical for shallow donors. Contrary to the results of other authors, no correlation was possible between the EPR signal and the visible range of PL spectra, which suggests that centers responsible for the visible emission and the EPR signal are different.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Organic semiconductor technology has attracted considerable research interest in view of its great promise for large area, lightweight, and flexible electronics applications. Owing to their advantages in processing and unique physical properties, organic semiconductors can bring exciting new opportunities for broad-impact applications requiring large area coverage, mechanical flexibility, low-temperature processing, and low cost. In order to achieve highly flexible device architecture it is crucial to understand on a microscopic scale how mechanical deformation affects the electrical performance of organic thin film devices. Towards this aim, I established in this thesis the experimental technique of Kelvin Probe Force Microscopy (KPFM) as a tool to investigate the morphology and the surface potential of organic semiconducting thin films under mechanical strain. KPFM has been employed to investigate the strain response of two different Organic Thin Film Transistor with active layer made by 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS-Pentacene), and Poly(3-hexylthiophene-2,5-diyl) (P3HT). The results show that this technique allows to investigate on a microscopic scale failure of flexible TFT with this kind of materials during bending. I find that the abrupt reduction of TIPS-pentacene device performance at critical bending radii is related to the formation of nano-cracks in the microcrystal morphology, easily identified due to the abrupt variation in surface potential caused by local increase in resistance. Numerical simulation of the bending mechanics of the transistor structure further identifies the mechanical strain exerted on the TIPS-pentacene micro-crystals as the fundamental origin of fracture. Instead for P3HT based transistors no significant reduction in electrical performance is observed during bending. This finding is attributed to the amorphous nature of the polymer giving rise to an elastic response without the occurrence of crack formation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polymers that are used in clinical practice as bone-defect-filling materials possess many essential qualities, such as moldability, mechanical strength and biodegradability, but they are neither osteoconductive nor osteoinductive. Osteoconductivity can be conferred by coating the material with a layer of calcium phosphate, which can be rendered osteoinductive by functionalizing it with an osteogenic agent. We wished to ascertain whether the morphological and physicochemical characteristics of unfunctionalized and bovine-serum-albumin (BSA)-functionalized calcium-phosphate coatings were influenced by the surface properties of polymeric carriers. The release kinetics of the protein were also investigated. Two sponge-like materials (Helistat® and Polyactive®) and two fibrous ones (Ethisorb and poly[lactic-co-glycolic acid]) were tested. The coating characteristics were evaluated using state-of-the-art methodologies. The release kinetics of BSA were monitored spectrophotometrically. The characteristics of the amorphous and the crystalline phases of the coatings were not influenced by either the surface chemistry or the surface geometry of the underlying polymer. The mechanism whereby BSA was incorporated into the crystalline layer and the rate of release of the truly incorporated depot were likewise unaffected by the nature of the polymeric carrier. Our biomimetic coating technique could be applied to either spongy or fibrous bone-defect-filling organic polymers, with a view to rendering them osteoconductive and osteoinductive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the inflammatory response to, and the osteoinductive efficacies of, four polymers (collagen, Ethisorb, PLGA and Polyactive) that bore either an adsorbed (fast-release kinetics) or a calcium-phosphate-coating-incorporated (slow-release kinetics) depot of BMP-2. Titanium-plate-supported discs of each polymer (n = 6 per group) were implanted at an ectopic (subcutaneous) ossification site in rats (n = 48). Five weeks later, they were retrieved for a histomorphometric analysis of the volumes of ectopic bone and foreign-body giant cells (a gauge of inflammatory reactivity), and the degree of polymer degradation. For each polymer, the osteoinductive efficacy of BMP-2 was higher when it was incorporated into a coating than when it was directly adsorbed onto the material. This mode of BMP-2 carriage was consistently associated with an attenuation of the inflammatory response. For coated materials, the volume density of foreign-body giant cells was inversely correlated with the volume density of bone (r(2) = 0.96), and the volume density of bone was directly proportional to the surface-area density of the polymer (r(2) = 0.97). Following coating degradation, other competitive factors, such as the biocompatibility and the biodegradability of the polymer itself, came into play.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thesis investigates the effect of surface treatment with various reducing and oxidizing agents on the quantum yield (QY) of CdSe and CdS quantum dots (QDs). The QDs, as synthesized by the organometallic method, contained defect sites on their surface that trapped photons and prevented their radiative recombination, therefore resulting in adecreased QY. To passivate these defect sites and enhance the QY, the QDs were treated with various reducing and oxidizing agents, including: sodium borohydride (NaBH4), calcium hydride (CaH2), hydrazine (N2H4), benzoyl peroxide (C14H10O4), and tert-butylhydroperoxide (C4H10O2). It was hypothesized that the reducing/oxidizing agents reduced the ligands on the QD surface, causing them to detach, thereby allowing oxygen from atmospheric air to bind to the exposed cadmium. This cadmium oxdide (CdO) layeraround the QD surface satisfied the defect sites and resulted in an increased QY. To correlate what effect the reducing and oxidizing agents were having on the optical properties of the QDs, we investigated these treatments on the following factors:chalcogenide (Se vs. S), ligand (oleylamine vs. OA), coordinating solvent (ODE vs.TOA), and dispersant solvent (chloroform vs. toluene) on the overall optical properties of the QDs. The QY of each sample was calculated before and after the various surface treatments from ultra-violet visible spectroscopy (UV-Vis) and fluorescence spectroscopy data to determine if the treatment was successful.From our results, we found that sodium borohydride was the most effective surface treatment, with 10 of the 12 treatments resulting in an increased QY. Hydrazine, on the other hand, was the least effective treatments, as it quenched the QD fluorescence in every case. From these observations, we hypothesize that the effectiveness of the QD surface treatments was dependent on reaction rate. More specifically, when the surface treatment reaction happened too quickly, we hypothesize that the QDs began to aggregate, resulting in a quenched fluorescence. Furthermore, we believe that the reactionrate is dependent on concentration of the reducing/oxidizing agents, solubility of the agents in each solvent, and reactivity of the agents with water. The quantum yield of the QDs can therefore be maximized by slowing the reaction rate of each surface treatment toa rate that allows for the proper passivation of defect sites.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This clinical study prospectively evaluated the healing outcome 1 year after apical surgery in relation to bony crypt dimensions measured intraoperatively. The study cohort included 183 teeth in an equal number of patients. For statistical analysis, results were dichotomized (healed versus non-healed cases). The overall success rate was 83% (healed cases). Healing outcome was not significantly related to the level and height of the facial bone plate. In contrast, a significant difference was found for the mean size of the bony crypt when healed cases (395 mm(3)) were compared with non-healed cases (554 mm(3)). In addition, healed cases had a significantly shorter mean distance (4.30 mm) from the facial bone surface to the root canal (horizontal access) compared with non-healed cases (5.13 mm). With logistic regression, however, the only parameter found to be significantly related to healing outcome was the length of the access window to the bony crypt.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Clinical magnetic resonance imaging (MRI) is the method of choice for the non-invasive evaluation of articular cartilage defects and the follow-up of cartilage repair procedures. The use of cartilage-sensitive sequences and a high spatial-resolution technique enables the evaluation of cartilage morphology even in the early stages of disease, as well as assessment of cartilage repair. Sequences that offer high contrast between articular cartilage and adjacent structures, such as the fat-suppressed, 3-dimensional, spoiled gradient-echo sequence and the fast spin-echo sequence, are accurate and reliable for evaluating intrachondral lesions and surface defects of articular cartilage. These sequences can also be performed together in reasonable examination times. In addition to morphology, new MRI techniques provide insight into the biochemical composition of articular cartilage and cartilage repair tissue. These techniques enable the diagnosis of early cartilage degeneration and help to monitor the effect and outcome of various surgical and non-surgical cartilage repair therapies.