507 resultados para Stent


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stenting has been shown to improve patency after femoral artery revascularization compared with balloon angioplasty. Limited data are available evaluating endovascular treatment for obstructive lesions of the popliteal artery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We sought to determine a potential interaction between statins and antiplatelet therapy with aspirin and clopidogrel. Previous laboratory studies have shown a possible drug-drug interaction of statins metabolized by cytochrome P450 3A4 and clopidogrel (prodrug metabolized by cytochrome P450 3A4), resulting in an impaired inhibitory effect of clopidogrel on platelet aggregation. However, conclusive prospective data assessing this potentially relevant interaction are lacking. In 73 patients, 23 with previous coronary stent thrombosis (ST) (ST group) and 50 without coronary ST (control group), platelet aggregation was measured 3 times in monthly intervals using light transmission aggregometry (adenosine diphosphate [ADP] and arachidonic acid induction). Measurements were carried out with aspirin monotherapy (100 mg/day), dual antiplatelet therapy with aspirin plus clopidogrel (75 mg/day), and additional treatment of 20 mg/day of atorvastatin or 40 mg/day of pravastatin. ADP (5 and 20 micromol)-induced platelet aggregation was significantly decreased with clopidogrel (p <0.001) but remained stable under additional treatment with atorvastatin or pravastatin in the 2 groups. Patients with previous ST showed a higher ADP-induced aggregation level than control subjects. This difference was not influenced by clopidogrel or statin treatment. In conclusion, patients with previous ST show a higher aggregation level than control subjects independent of statin treatment. Atorvastatin and pravastatin do not interfere with the antiaggregatory effect of aspirin and clopidogrel. In conclusion, drug-drug interaction between dual antiplatelet therapy and atorvastatin or pravastatin seems not to be associated with ST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Restenosis has been the principal limitation of bare metal stents. Based upon the presumption that platelet and inflammatory cell recruitment initiate neointimal proliferation, we explored a novel polymer coating that reduces cell-stent interactions. The purpose of the present study was to investigate the effect of poly(L-lysine)-graft-poly(ethyleneglycol) (PLL-g-PEG) adsorbed to stent surfaces to reduce neointimal hyperplasia in the porcine restenosis model. METHODS AND RESULTS: Seven animals were instrumented each with 2 stainless steel stents (15 mm length, 2.5-3.5 mm diameter), randomly implanted in 1 major epicardial coronary artery. One stent was dip-coated with PLL-g-PEG, whereas the other stent served as the uncoated control stent. All animals were sacrificed after 6 weeks for histological examination. Neointimal hyperplasia was significantly less (-51%) in the PLL-g-PEG-coated stents (1.15 +/- 0.59 mm2) than in the uncoated control stents (2.33 +/- 1.01 mm2; p < 0.001). Conversely, lumen size was larger in the PLL-g-PEG-coated stents (2.91 +/- 1.17 mm2) than in the uncoated stents (2.04 +/- 0.64 mm2; p < 0.001). High magnification histomorphologic examination revealed no signs of inflammation or thrombus formation in either stent group. CONCLUSIONS: Polymeric steric stabilization of stents with PLL-g-PEG significantly reduces neointimal hyperplasia in the porcine restenosis model. Reduction of cell-stent interactions mediated by PLL-g-PEG appear to improve biocompatibility of stainless steel stents without evidence of adverse inflammatory or prothrombotic effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare coronary collateral function in patients after bare-metal stent (BMS) or drug-eluting stent (DES) implantation. BACKGROUND: Drug-eluting stents have an inhibitory effect on the production of cytokines, chemotactic proteins, and growth factors, and may therefore negatively affect coronary collateral growth. METHODS: A total of 120 patients with long-term stable coronary artery disease (CAD) after stent implantation were included. Both the BMS group and the DES group comprised 60 patients matched for in-stent stenosis severity of the vessel undergoing collateral flow index (CFI) measurement at follow-up and for the duration of follow-up. The primary end point of the investigation was invasively determined coronary collateral function 6 months after stent implantation. Collateral function was assessed by simultaneous aortic, coronary wedge, and central venous pressure measurements (yielding CFI) and by intracoronary electrocardiogram during balloon occlusion. RESULTS: There were no differences between the groups regarding age, gender, body mass index, frequency of cardiovascular risk factors, use of cardiovascular drugs, severity of CAD, or site of coronary artery stenoses. Despite equal in-stent stenosis severity (46 +/- 34% and 45 +/- 36%) and equal follow-up duration (6.2 +/- 10 months and 6.5 +/- 5.4 months), CFI was diminished in the DES versus BMS group (0.154 +/- 0.097 vs. 0.224 +/- 0.142; p = 0.0049), and the rate of collaterals insufficient to prevent ischemia during occlusion (intracoronary electrocardiographic ST-segment elevation > or =0.1 mV) was higher with 50 of 60 patients in the DES group and 33 of 60 patients in the BMS group (p = 0.001). CONCLUSIONS: Collateral function long after coronary stenting is impaired with DES (sirolimus and paclitaxel) when compared with BMS. Considering the protective nature of collateral vessels, this could lead to more serious cardiac events in the presence of an abrupt coronary occlusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the case of 77-year-old woman who underwent five coronary angiographies in 9 months due to in-stent re-stenosis of Cypher-Stents, and who finally required coronary artery bypass grafting surgery. Preoperative investigations revealed a significant internal carotid stenosis, which was due to a fractured and embolized Cypher-Stent.