971 resultados para Static load test


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During knee ligament reconstruction, the tendon graft is tensioned to prevent the occurrence of excessive graft elongation during the postoperative period. Tensioning may be achieved by applying a cyclic or static load to the graft during fixation. Although this procedure is part of the surgery, there is no consensus in international literature regarding ideal tension levels to be used in this procedure. This study was conducted on 10 tendons of the human gracilis muscle and 10 tendons of semitendinosus muscle removed from five male cadavers whose mean age was 20.8 years. These tendons underwent 10 in vitro strain cycles at three levels of deformation (2.5, 3, and 4%) and the value of the deforming load used for each cycle was recorded. The statistical analysis demonstrated that in order to attain the same level of deformation during the 10 cycles there was a reduction in the value of strain applied to the graft, observed at the three levels of deformation. It was concluded that the semitendinosus tendon presents a more uniform mechanical behavior and that there is a need for new graft tensioning protocols that consider the force associated with deformation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The maximal lactate steady state (MLSS) is the highest blood lactate concentration that can be identified as maintaining a steady state during a prolonged submaximal constant workload. The objective of the present study was to analyze the influence of the aerobic capacity on the validity of anaerobic threshold (AT) to estimate the exercise intensity at MLSS (MLSS intensity) during cycling. Ten untrained males (UC) and 9 male endurance cyclists (EC) matched for age, weight and height performed one incremental maximal load test to determine AT and two to four 30-min constant submaximal load tests on a mechanically braked cycle ergometer to determine MLSS and MLSS intensity. AT was determined as the intensity corresponding to 3.5 mM blood lactate. MLSS intensity was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. MLSS intensity (EC = 282.1 ± 23.8 W; UC = 180.2 ± 24.5 W) and AT (EC = 274.8 ± 24.9 W; UC = 187.2 ± 28.0 W) were significantly higher in trained group. However, there was no significant difference in MLSS between EC (5.0 ± 1.2 mM) and UC (4.9 ± 1.7 mM). The MLSS intensity and AT were not different and significantly correlated in both groups (EC: r = 0.77; UC: r = 0.81). We conclude that MLSS and the validity of AT to estimate MLSS intensity during cycling, analyzed in a cross-sectional design (trained x sedentary), do not depend on the aerobic capacity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo deste estudo foi comparar a intensidade de exercício no lactato mínimo (LACmin), com a intensidade correspondente ao limiar de lactato (LL) e limiar anaeróbio (LAn). Participaram do estudo, 11 atletas do sexo masculino (idade, 22,5 + 3,17 anos; altura, 172,3 + 8,2 cm; peso, 66,9 + 8,2kg; e gordura corporal, 9,8 + 3,4%). Os indivíduos foram submetidos, em uma bicicleta eletromagnética (Quinton - Corival 400), a dois testes: 1) exercício contínuo de cargas crescentes - carga inicial de 100W, com incrementos de 25W a cada três min. até a exaustão voluntária; e 2) teste de lactato mínimo - inicialmente os indivíduos pedalaram duas vezes 425W (+ 120%max) durante 30 segundos, com um min. de intervalo, com o objetivo de induzir o acúmulo de lactato. Após oito min. de recuperação passiva, os indivíduos iniciaram um teste contínuo de cargas progressivas, idêntico ao descrito anteriormente. O LL e o LAn foram identificados como sendo o menor valor entre a razão - lactato sanguíneo (mM) / intensidade de exercício (W), e a intensidade correspondente a 3,5mM de lactato sanguíneo, respectivamente. O LACmin foi identificado como sendo a intensidade correspondente a menor concentração de lactato durante o teste de cargas progressivas. Não foi observada diferença significante entre a potência do LL (197,7 + 20,7W) e do LACmin (201,6 + 13,0W), sendo ambas significantemente menores do que do LAn (256,7 + 33,3W). Não foram encontradas também diferenças significantes para o (ml.kg-1.min-1) e a FC (bpm) obtidos no LL (43,2 + 5,01; 152,0 + 13,0) e no LACmin (42,1 + 3,9; 159,0 + 10,0), sendo entretanto significantemente menores do que os obtidos para o LAn (52,2 + 8,2; 174,0 + 13,0, respectivamente). Pode-se concluir que o teste de LACmin, nas condições experimentais deste estudo, pode subestimar a intensidade de MSSLAC (estimada indiretamente pelo LAn), o que concordacom outros estudos que determinaram a MSSLAC diretamente. Assim, são necessários mais estudos que analisem o possível componente tempo-dependente (intensidade inicial) que pode existir no protocolo do LACmin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo deste estudo foi analisar a validade do consumo máximo de oxigênio (VO2max), velocidade associada ao VO2max (vVO2max), tempo de exaustão na vVO2max (Tlim), limiar anaeróbio (LAn), economia de corrida (EC) e força explosiva (FE) para predizer a performance aeróbia de corredores de endurance nas distâncias de 1.500m, 5.000m e 10.000m. Participaram deste estudo 11 corredores de endurance moderadamente treinados (28,36 ± 6,47 anos) que realizaram os seguintes testes: provas simuladas em uma pista de 400m em diferentes dias, nas distâncias de 10.000m, 5.000m e 1.500m; teste incremental máximo para determinar os índices VO2max, vVO2max, e LAn; um teste submáximo de carga constante para determinar a EC, seguido por um teste máximo também de carga constante a 100% da vVO2max para determinar o Tlim; e um teste de salto vertical para determinar a FE. de acordo com a análise de regressão múltipla, a vVO2max utilizada de forma isolada explicou 57% da variação de performance na prova de 1.500m. No entanto, quando o Tlim, a FE e a vVO2max foram analisados em conjunto, a explicação para a performance nessa prova foi de 88%. Nos 5.000m, o Tlim, a vVO2max e o LAn responderam por 88% da variação de performance (p < 0,05). Diferentemente, na prova de 10.000m, o LAn foi a única variável que apresentou capacidade de predição de performance. em conclusão, a predição da performance aeróbia de corredores moderadamente treinados por meio de variáveis fisiológicas e neuromusculares é dependente da distância da prova (1.500m, 5.000m e 10.000m)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A finite element analysis was carried out to study the role of prefabricated threaded split shaft post (Flexi-Post) on dentinal stress in pulpless tooth. Three dimensional plane strain model of mesio-distal section of a human maxillary central incisor without restoration was analysed with the MSC/NASTRAN (MacNeal/ Schwendler) general purpose finite analysis program was executed on a microcomputer. The model as discretized into 48.954 axisymmetric finite elements defined by 10.355 nodes. Each element was assigned unique elastic properties to represent the materials modeled. Homogeneity, isotropy and linear elasticity were assume for all material. A simulation of static load of 100N was applied to the incisal edge of the post; vertical. Maximal principal stresses and von Mises equivalent stress were calculated. Using the element analysis model employed in this study, the following can be concluded concerning threaded split shaft post (Flexi-Post): Maximum principal stresses in dentin were located at cervical place and at the post apex. The apical threads of the post not redirecting stresses away from the root.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effect of different anatomic shapes and materials of posts in the stress distribution on an endodontically treated incisor was evaluated in this work. This study compared three post shapes (tapered, cylindrical and two-stage cylindrical) made of three different materials (stainless steel, titanium and carbon fibre on Bisphenol A-Glycidyl Methacrylate (Bis-GMA) matrix). Two-dimensional stress analysis was performed using the Finite Element Method. A static load of 100N was applied at 45degrees inclination with respect to the incisor's edge. The stress concentrations did not significantly affect the region adjacent to the alveolar bone crest at the palatine portion of the tooth, regardless of the post shape or material. However, stress concentrations on the post/dentin interface on the palatine side of the tooth root presented significant variations for different post shapes and materials. Post shapes had relatively small impact on the stress concentrations while post materials introduced higher variations on them. Stainless steel posts presented the highest level of stress concentration, followed by titanium and carbon/Bis-GMA posts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

1. Maximal lactate steady state (MLSS) corresponds to the highest blood lactate concentration (MLSSc) and workload (MLSSw) that can be maintained over time without continual blood lactate accumulation and is considered an important marker of endurance exercise capacity. The present study was undertaken to determine MLSSw and MLSSc in running mice. In addition, we provide an exercise training protocol for mice based on MLSSw.2. Maximal lactate steady state was determined by blood sampling during multiple sessions of constant-load exercise varying from 9 to 21 m/min in adult male C57BL/6J mice. The constant-load test lasted at least 21 min. The blood lactate concentration was analysed at rest and then at 7 min intervals during exercise.3. The MLSSw was found to be 15.1 +/- 0.7 m/min and corresponded to 60 +/- 2% of maximal speed achieved during the incremental exercise testing. Intra- and interobserver variability of MLSSc showed reproducible findings. Exercise training was performed at MLSSw over a period of 8 weeks for 1 h/day and 5 days/week. Exercise training led to resting bradycardia (21%) and increased running performance (28%). of interest, the MLSSw of trained mice was significantly higher than that in sedentary littermates (19.0 +/- 0.5 vs 14.2 +/- 0.5 m/min; P = 0.05), whereas MLSSc remained unchanged (3.0 mmol/L).4. Altogether, we provide a valid and reliable protocol to improve endurance exercise capacity in mice performed at highest workload with predominant aerobic metabolism based on MLSS assessment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The maximal lactate steady state (MLSS) is defined as the highest blood lactate concentration that can be maintained over time without a continual blood lactate accumulation. The objective of the present study was to analyze the effects of pedal cadence (50 vs. 100 rev min(-1)) on MLSS and the exercise workload at MLSS (MLSSworkload) during cycling. Nine recreationally active males (20.9 +/- 2.9 years, 73.9 +/- 6.5 kg, 1.79 +/- 0.09 m) performed an incremental maximal load test (50 and 100 rev min(-1)) to determine anaerobic threshold (AT) and peak workload (PW), and between two and four constant submaximal load tests (50 and 100 rev min(-1)) on a mechanically braked cycle ergometer to determine MLSSworkload and MLSS. MLSSworkload was defined as the highest workload at which blood lactate concentration did not increase by more than 1 mM between minutes 10 and 30 of the constant workload. The maximal lactate steady state intensity (MLSSintensity) was defined as the ratio between MLSSworkload and PW. MLSSworkload (186.1 +/- 21.2 W vs. 148.2 +/- 15.5 W) and MLSSintensity (70.5 +/- 5.7% vs. 61.4 +/- 5.1%) were significantly higher during cycling at 50 rev min(-1) than at 100 rev min(-1), respectively. However, there was no significant difference in MLSS between 50 rev min(-1) (4.8 +/- 1.6 mM) and 100 rev min(-1) (4.7 +/- 0.8 mM). We conclude that MLSSworkload and MLSSintensity are dependent on pedal cadence (50 vs. 100 rev min(-1)) in recreationally active individuals. However, this study showed that MLSS is not influenced by the different pedal cadences analyzed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The compaction rate, the relation between the density of the wood panel and the density of the wood used for producing the particles, is an indicator of the product's densification. Among the various types of wood panels, particleboards are widely employed in the lumber industry, mainly for the furniture production. This paper presents a study of the relation between the compaction rate and the properties of tensile strength perpendicular to surface, Modulus of Rupture (MOR) and Modulus of Elasticity (MOE) obtained from a static bending test, thickness swelling and water absorption (2 and 24 hours). These properties were calculated according to the Brazilian ABNT, NBR 14810 standard. Particleboards were produced using the species Pinus elliotti and adhesive ureaformaldehyde. The relation was established by a multiple linear regression, and the most appropriate statistical models were determined. The estimated models indicate statistically significant effects of water absorption in 2 hours and MOR in the particleboards' compaction rate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this study was to assess the influence of a fluoridated medium on the mechanical properties of an internal hexagon implant-abutment set, by means of compression, mechanical cycling and metallographic characterization by scanning electronic microscopy. Five years of regular use of oral hygiene with a sodium fluoride solution content of 1500 ppm were simulated, immersing the samples in this medium for 184 hours, with the solutions being changed every 12 hours. Data were analyzed at a 95% confidence level with Fisher's exact test. After the action of fluoride ions, a negative influence occurred in the mechanical cycling test performed in a servohydraulic machine (Material Test System-810) set to a frequency of 15 Hz with 100,000 cycles and programmed to 60% of the maximum resistance of static compression test. The sets tended to fracture by compression on the screw, characterized by mixed ruptures with predominance of fragile fracture, as observed by microscopy. An evidence of corrosion by pitting on sample surfaces was found after the fluoride ions action. It may be concluded that prolonged contact with fluoride ions is harmful to the mechanical properties of commercially pure titanium structures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents results from stress cracking (SC) tests performed in both fresh and exposed high density polyethylene (HDPE) geomembranes (GM). The HDPE GMs were exposed to ultraviolet radiation, thermal aging (air oven) and tested for chemical compatibility with sodium hydroxide. Stress cracking tests in both fresh and degraded samples were performed in accordance to ASTM D5397: Notched Constant Tensile Load Test (NCTL) and Single Point-Notched Constant Tensile Load Test (SP-NCTL). The results of the NCTL showed that the geomembrane degradation process can be considered to be a catalyst for the phenomenon of SC because it caused a 50% to 60% reduction in stress crack resistance. The most resistance reduction was observed for the sample under chemical compatibility with sodium hydroxide. For the SP-NCTL, the results showed that the samples maintain the same trend verified in the NCTL. The largest resistance reduction was evidenced in samples undergoing ultraviolet degradation. © 2012 ejge.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)