932 resultados para Spanish Q for tourist quality mark


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the underreporting rate of death -cause data in Shandong province during 2012 to 2013 by capture -mark -recapture method and to provide the base for health strategy. Methods All counties were divided into 5 stratifications according the death rates of 2012, and 14 counties were selected, then 3 towns or streets were selected in each country, 10 villages or neighborhood committees were selected in each town (street). The death data collected from security bureau and civil affairs bureau were compared with the reporting death data from the National Cause of Death Surveillance, and the underreporting rate was calculated. Results In present study, 6 929 death cases were collected, it was found that 1 556 cases were underreported. The death cases estimated by CMR method were 6 227 cases (95%CI: 7 593-7 651), and the average underreporting rate was 23.15%. There were significantly differences between different stratifications (P<0.01). The underreporting rate in 0-4 years old group was 56.93%, the male underreporting rate was 22.31% and the female underreporting rate was 24.09%. There was no significant difference between male and female groups (P>0.05). Conclusion There is an obvious underreport in the cause of death surveillance of Shandong province, and the underreporting rates are different among the 5 stratifications. The underreporting rate is higher in 0-4 years old group, and the investigation of the death cause surveillance for young residents is not perfect in some countries. The investigation quality of the death cause surveillance should be improved, increasing the integrity of the report data and adjusting the mortalities in different stratifications for obtaining a accurate mortality in Shandong province.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The designs are drawn in the miniature style of postage stamps and include mock postage prices. Presumably this method was inspired by the shortage of paper at the camp in Gurs, Southern France, where these works were done; but specially this format is also used to stress the irony of the content, especially in the trio of design marked "Liberte-Egalite-Fraternite", aside from one marked "Avion de Gurs", all others are labelled simply " Gurs ", at the bottom as if this were the country of origin of a postal system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An overview of the Centre for Accident Research and Road Safety - Queensland and its main areas of research. Background to CARRS-Q Established in 1996 as joint initiative of: - Queensland University of Technology - Queensland Motor Accident Insurance Commission - Based in the Faculty of Health - Our Vision is for: A safer world in which injury-related harm is uncommon and unacceptable

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Earth's ecosystems are protected from the dangerous part of the solar ultraviolet (UV) radiation by stratospheric ozone, which absorbs most of the harmful UV wavelengths. Severe depletion of stratospheric ozone has been observed in the Antarctic region, and to a lesser extent in the Arctic and midlatitudes. Concern about the effects of increasing UV radiation on human beings and the natural environment has led to ground based monitoring of UV radiation. In order to achieve high-quality UV time series for scientific analyses, proper quality control (QC) and quality assurance (QA) procedures have to be followed. In this work, practices of QC and QA are developed for Brewer spectroradiometers and NILU-UV multifilter radiometers, which measure in the Arctic and Antarctic regions, respectively. These practices are applicable to other UV instruments as well. The spectral features and the effect of different factors affecting UV radiation were studied for the spectral UV time series at Sodankylä. The QA of the Finnish Meteorological Institute's (FMI) two Brewer spectroradiometers included daily maintenance, laboratory characterizations, the calculation of long-term spectral responsivity, data processing and quality assessment. New methods for the cosine correction, the temperature correction and the calculation of long-term changes of spectral responsivity were developed. Reconstructed UV irradiances were used as a QA tool for spectroradiometer data. The actual cosine correction factor was found to vary between 1.08-1.12 and 1.08-1.13. The temperature characterization showed a linear temperature dependence between the instrument's internal temperature and the photon counts per cycle. Both Brewers have participated in international spectroradiometer comparisons and have shown good stability. The differences between the Brewers and the portable reference spectroradiometer QASUME have been within 5% during 2002-2010. The features of the spectral UV radiation time series at Sodankylä were analysed for the time period 1990-2001. No statistically significant long-term changes in UV irradiances were found, and the results were strongly dependent on the time period studied. Ozone was the dominant factor affecting UV radiation during the springtime, whereas clouds played a more important role during the summertime. During this work, the Antarctic NILU-UV multifilter radiometer network was established by the Instituto Nacional de Meteorogía (INM) as a joint Spanish-Argentinian-Finnish cooperation project. As part of this work, the QC/QA practices of the network were developed. They included training of the operators, daily maintenance, regular lamp tests and solar comparisons with the travelling reference instrument. Drifts of up to 35% in the sensitivity of the channels of the NILU-UV multifilter radiometers were found during the first four years of operation. This work emphasized the importance of proper QC/QA, including regular lamp tests, for the multifilter radiometers also. The effect of the drifts were corrected by a method scaling the site NILU-UV channels to those of the travelling reference NILU-UV. After correction, the mean ratios of erythemally-weighted UV dose rates measured during solar comparisons between the reference NILU-UV and the site NILU-UVs were 1.007±0.011 and 1.012±0.012 for Ushuaia and Marambio, respectively, when the solar zenith angle varied up to 80°. Solar comparisons between the NILU-UVs and spectroradiometers showed a ±5% difference near local noon time, which can be seen as proof of successful QC/QA procedures and transfer of irradiance scales. This work also showed that UV measurements made in the Arctic and Antarctic can be comparable with each other.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An attempt is made to discuss in brief the current philosophy and trends in quality assurance through nondestructive testing. The techniques currently in use and those being developed for newer and advanced materials such as composites are reviewed. 27 ref.--AA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports the design and electrical characterization of a micromechanical disk resonator fabricated in single crystal silicon using a foundry SOI micromachining process. The microresonator has been selectively excited in the radial extensional and the wine glass modes by reversing the polarity of the DC bias voltage applied on selected drive electrodes around the resonant structure. The quality factor of the resonator vibrating in the radial contour mode was 8000 at a resonant frequency of 6.34 MHz at pressure below 10 mTorr vacuum. The highest measured quality factor of the resonator in the wine glass resonant mode was 1.9 × 106 using a DC bias voltage of 20 V at about the same pressure in vacuum; the resonant frequency was 5.43 MHz and the lowest motional resistance measured was approximately 17 kΩ using a DC bias voltage of 60 V applied across 2.7 μm actuation gaps. This corresponds to a resonant frequency-quality factor (f-Q) product of 1.02 × 1013, among the highest reported for single crystal silicon microresonators, and on par with the best quartz crystal resonators. The quality factor for the wine glass mode in air was approximately 10,000. © 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a technique for independently exciting two resonant modes of vibration in a single-crystal silicon bulk mode microresonator using the same electrode configuration through control of the polarity of the DC actuation voltage. Applications of this technique may include built-in temperature compensation by the simultaneous selective excitation of two closely spaced modes that may have different temperature coefficients of resonant frequency. The technique is simple and requires minimum circuit overhead for implementation. The technique is implemented on square plate resonators with quality factors as high as 3.06 × 106. Copyright © 2008 by ASME.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on the experimental characterization of a single crystal silicon square-plate microresonator. The resonator is excited in the square wine glass (SWG) mode at a mechanical resonance frequency of 2.065 MHz. The resonator displays quality factor of 9660 in air and an ultra-high quality factor of Q = 4.05 × 106 in 12 mtorr vacuum. The SWG mode may be described as a square plate that contracts along one axis in the fabrication plane, while simultaneously extending along an orthogonal axis in the same plane. The resonant structure is addressed in a 2-terminal configuration by utilizing equal and opposite drive polarities on surrounding capacitor electrodes, thereby decreasing the motional resistance of the resonator. The resonant micromechanical device has been fabricated in a commercial silicon-on-insulator process through the MEMSCAP foundry utilising a minimum electrostatic gap of 2 μm. © 2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports a preliminary examination of the effect of anchor geometry design on the quality factor of flexural mode resonators operating in vacuum using both FE simulation and measurements of resonator frequency response. Three types of structures have been considered in this study: an elliptical mode ring, a double ended tuning fork, and a doubly-clamped beam. We consider the relative distribution of strain energies in both the resonant structure and the connecting stem, which is indicative of the measured quality factor. The measured quality factors of the different structures are compared against each other, based on which suggestions are proposed for optimizing the anchor limited quality factor (Q) in flexural mode micromechanical resonators. ©2008 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A 32.1 W laser-diode-stack pumped acoustic-optic Q-switched Nd:YVO4 slab laser with hybrid resonator at 1064 nm was demonstrated with the pumping power of 112 W and repetition rate of 40 kHz, the pulse duration was 32.47 ns. The slope efficiency and optical-to-optical efficiency were 37 and 28.7%, respectively. At the repetition rate of 20 kHz and pumping power of 90 W, the average output power and pulse duration were 20.4 W and 20.43 ns, respectively. With the pumping power of 112 W, the beam quality M-2 factors in CW operation were measured to be 1.3 in stable direction and 1.6 in unstable direction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to explore the potential role that quality objectives, particularly when backed by statutory force, may play in the sustainable management of river water quality. Economic valuation techniques are discussed, as well as the theory of "critical natural capital". A brief history of water quality legislation includes the implementation of the National Water Council classification in 1979, and the statutory water quality objectives introduced under the Water Resources Act 1991.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A planar waveguide laser operating in a negative branch unstable resonator is Q-switched by an acoustooptic mod latorin anew configuration, providing effective, high-speed switching. The laser using a 200-mu m Nd:YAG core, face pumped by 10 laser diode bars, has produced 100-W output in a good beam quality at 100-kHz pulse rate, and 4.5 mJ at lower frequency with 15-ns pulse duration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

实验报道采用我国自行设计的大模场掺镱双包层光纤,利用简单声光调Q装置,成功实现调Q运转;在1-50kHz调制频率下获得了百纳秒的调Q脉冲,其输出光束质量因子大约为2。当重复频率为1kHz时,获得了脉冲宽度为132ns,能量0.93mJ。同时实验中观察到的调Q脉冲常出现一点锁模现象,针对这一现象进行了讨论。

Relevância:

30.00% 30.00%

Publicador:

Resumo:

文中报道了一台采用激光二极管部分边缘泵浦方式的高功率薄片激光器,晶体尺寸是1 mm×10 mm×60 mm。Cr4+:YAG被用来作为被动调Q晶体,在重复频率高于10kHz时,获得了脉宽10ns,平均功率70W,斜线效率为36\%的激光输出。通过控制泵浦光束直径的大小,我们在厚度方向得到了近似衍射极限的光束输出。整个激光器结构紧凑,大小为60 mm×174 mm×150 mm。