966 resultados para Sound recordings.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a framework in which samples of bowing gesture parameters are retrieved and concatenated from a database of violin performances by attending to an annotated input score. Resulting bowing parameter signals are then used to synthesize sound by means of both a digital waveguide violin physical model, and an spectral-domainadditive synthesizer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the recognition of sounds to benefit perception and action, their neural representations should also encode their current spatial position and their changes in position over time. The dual-stream model of auditory processing postulates separate (albeit interacting) processing streams for sound meaning and for sound location. Using a repetition priming paradigm in conjunction with distributed source modeling of auditory evoked potentials, we determined how individual sound objects are represented within these streams. Changes in perceived location were induced by interaural intensity differences, and sound location was either held constant or shifted across initial and repeated presentations (from one hemispace to the other in the main experiment or between locations within the right hemispace in a follow-up experiment). Location-linked representations were characterized by differences in priming effects between pairs presented to the same vs. different simulated lateralizations. These effects were significant at 20-39 ms post-stimulus onset within a cluster on the posterior part of the left superior and middle temporal gyri; and at 143-162 ms within a cluster on the left inferior and middle frontal gyri. Location-independent representations were characterized by a difference between initial and repeated presentations, independently of whether or not their simulated lateralization was held constant across repetitions. This effect was significant at 42-63 ms within three clusters on the right temporo-frontal region; and at 165-215 ms in a large cluster on the left temporo-parietal convexity. Our results reveal two varieties of representations of sound objects within the ventral/What stream: one location-independent, as initially postulated in the dual-stream model, and the other location-linked.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plants propagate electrical signals in response to artificial wounding. However, little is known about the electrophysiological responses of the phloem to wounding, and whether natural damaging stimuli induce propagating electrical signals in this tissue. Here, we used living aphids and the direct current (DC) version of the electrical penetration graph (EPG) to detect changes in the membrane potential of Arabidopsis sieve elements (SEs) during caterpillar wounding. Feeding wounds in the lamina induced fast depolarization waves in the affected leaf, rising to maximum amplitude (c. 60 mV) within 2 s. Major damage to the midvein induced fast and slow depolarization waves in unwounded neighbor leaves, but only slow depolarization waves in non-neighbor leaves. The slow depolarization waves rose to maximum amplitude (c. 30 mV) within 14 s. Expression of a jasmonate-responsive gene was detected in leaves in which SEs displayed fast depolarization waves. No electrical signals were detected in SEs of unwounded neighbor leaves of plants with suppressed expression of GLR3.3 and GLR3.6. EPG applied as a novel approach to plant electrophysiology allows cell-specific, robust, real-time monitoring of early electrophysiological responses in plant cells to damage, and is potentially applicable to a broad range of plant-herbivore interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY OBJECTIVES: Traditionally, sleep studies in mammals are performed using electroencephalogram/electromyogram (EEG/EMG) recordings to determine sleep-wake state. In laboratory animals, this requires surgery and recovery time and causes discomfort to the animal. In this study, we evaluated the performance of an alternative, noninvasive approach utilizing piezoelectric films to determine sleep and wakefulness in mice by simultaneous EEG/EMG recordings. The piezoelectric films detect the animal's movements with high sensitivity and the regularity of the piezo output signal, related to the regular breathing movements characteristic of sleep, serves to automatically determine sleep. Although the system is commercially available (Signal Solutions LLC, Lexington, KY), this is the first statistical validation of various aspects of sleep. DESIGN: EEG/EMG and piezo signals were recorded simultaneously during 48 h. SETTING: Mouse sleep laboratory. PARTICIPANTS: Nine male and nine female CFW outbred mice. INTERVENTIONS: EEG/EMG surgery. MEASUREMENTS AND RESULTS: The results showed a high correspondence between EEG/EMG-determined and piezo-determined total sleep time and the distribution of sleep over a 48-h baseline recording with 18 mice. Moreover, the piezo system was capable of assessing sleep quality (i.e., sleep consolidation) and interesting observations at transitions to and from rapid eye movement sleep were made that could be exploited in the future to also distinguish the two sleep states. CONCLUSIONS: The piezo system proved to be a reliable alternative to electroencephalogram/electromyogram recording in the mouse and will be useful for first-pass, large-scale sleep screens for genetic or pharmacological studies. CITATION: Mang GM, Nicod J, Emmenegger Y, Donohue KD, O'Hara BF, Franken P. Evaluation of a piezoelectric system as an alternative to electroencephalogram/electromyogram recordings in mouse sleep studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antihypertensive effects of the beta-blocking agent betaxolol and the calcium entry blocker verapamil were compared in a crossover single-blind trial. Seventeen patients with uncomplicated essential hypertension took either betaxolol or a slow-release formulation of verapamil for two consecutive 6-week periods. The sequence of treatment phases was randomly allocated and a 2-week washout period preceded each treatment. The antihypertensive effect of the test drugs was assessed both at the physician's office and during everyday activities using a portable blood pressure recorder. The crossover design of the trial made it possible to evaluate the antihypertensive efficacy of betaxolol and verapamil both in the group as a whole and in the individual patient. The individual patient response to one of these agents was not a reliable indicator of the same patient's response to the alternative agent. Betaxolol brought both office and ambulatory recorded blood pressures under control in a larger fraction of patients than verapamil, although the magnitude of the blood pressure fall in the responders was equal for each drug. These observations stress the need for an individualized approach to the evaluation of antihypertensive therapy. The present results also demonstrate that optimal antihypertensive therapy is still a matter of trial and error. The precise methodology that ought to characterize crossover trials may make it possible to improve the therapeutic approach to hypertensive patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Environmental sounds are highly complex stimuli whose recognition depends on the interaction of top-down and bottom-up processes in the brain. Their semantic representations were shown to yield repetition suppression effects, i. e. a decrease in activity during exposure to a sound that is perceived as belonging to the same source as a preceding sound. Making use of the high spatial resolution of 7T fMRI we have investigated the representations of sound objects within early-stage auditory areas on the supratemporal plane. The primary auditory cortex was identified by means of tonotopic mapping and the non-primary areas by comparison with previous histological studies. Repeated presentations of different exemplars of the same sound source, as compared to the presentation of different sound sources, yielded significant repetition suppression effects within a subset of early-stage areas. This effect was found within the right hemisphere in primary areas A1 and R as well as two non-primary areas on the antero-medial part of the planum temporale, and within the left hemisphere in A1 and a non-primary area on the medial part of Heschl's gyrus. Thus, several, but not all early-stage auditory areas encode the meaning of environmental sounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neural response to a violation of sequences of identical sounds is a typical example of the brain's sensitivity to auditory regularities. Previous literature interprets this effect as a pre-attentive and unconscious processing of sensory stimuli. By contrast, a violation to auditory global regularities, i.e. based on repeating groups of sounds, is typically detectable when subjects can consciously perceive them. Here, we challenge the notion that global detection implies consciousness by testing the neural response to global violations in a group of 24 patients with post-anoxic coma (three females, age range 45-87 years), treated with mild therapeutic hypothermia and sedation. By applying a decoding analysis to electroencephalographic responses to standard versus deviant sound sequences, we found above-chance decoding performance in 10 of 24 patients (Wilcoxon signed-rank test, P < 0.001), despite five of them being mildly hypothermic, sedated and unarousable. Furthermore, consistently with previous findings based on the mismatch negativity the progression of this decoding performance was informative of patients' chances of awakening (78% predictive of awakening). Our results show for the first time that detection of global regularities at neural level exists despite a deeply unconscious state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dual-stream model of auditory processing postulates separate processing streams for sound meaning and for sound location. The present review draws on evidence from human behavioral and activation studies as well as from lesion studies to argue for a position-linked representation of sound objects that is distinct both from the position-independent representation within the ventral/What stream and from the explicit sound localization processing within the dorsal/Where stream.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE: Limited-channel portable monitors (PMs) are increasingly used as an alternative to polysomnography (PSG) for the diagnosis of obstructive sleep apnoea (OSA). However, recommendations for the scoring of PM recordings are still lacking. Pulse-wave amplitude (PWA) drops, considered as surrogates for EEG arousals, may increase the detection sensitivity for respiratory events in PM recordings. OBJECTIVES: To investigate the performance of four different hypopnoea scoring criteria, using 3% or 4% oxygen desaturation levels, including or not PWA drops as surrogates for EEG arousals, and to determine the impact of measured versus reported sleep time on OSA diagnosis. METHODS: Subjects drawn from a population-based cohort underwent a complete home PSG. The PSG recordings were scored using the 2012 American Academy of Sleep Medicine criteria to determine the apnoea-hypopnoea index (AHI). Recordings were then rescored using only parameters available on type 3 PM devices according to different hypopnoea criteria and patients-reported sleep duration to determine the 'portable monitor AHIs' (PM-AHIs). MAIN RESULTS: 312 subjects were included. Overall, PM-AHIs showed a good concordance with the PSG-based AHI although it tended to slightly underestimate it. The PM-AHI using 3% desaturation without PWA drops showed the best diagnostic accuracy for AHI thresholds of ≥5/h and ≥15/h (correctly classifying 94.55% and 93.27% of subjects, respectively, vs 80.13% and 87.50% with PWA drops). There was a significant but modest correlation between PWA drops and EEG arousals (r=0.20, p=0.0004). CONCLUSION: Interpretation of PM recordings using hypopnoea criteria which include 3% desaturation without PWA drops as EEG arousal surrogate showed the best diagnosis accuracy compared with full PSG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Nucleus accumbens (Nacc) has been proposed to act as a limbic-motor interface. Here, using invasive intraoperative recordings in an awake patient suffering from obsessive-compulsive disease (OCD), we demonstrate that its activity is modulated by the quality of performance of the subject in a choice reaction time task designed to tap action monitoring processes. Action monitoring, that is, error detection and correction, is thought to be supported by a system involving the dopaminergic midbrain, the basal ganglia, and the medial prefrontal cortex. In surface electrophysiological recordings, action monitoring is indexed by an error-related negativity (ERN) appearing time-locked to the erroneous responses and emanating from the medial frontal cortex. In preoperative scalp recordings the patient's ERN was found to be signifi cantly increased compared to a large (n = 83) normal sample, suggesting enhanced action monitoring processes. Intraoperatively, error-related modulations were obtained from the Nacc but not from a site 5 mm above. Importantly, crosscorrelation analysis showed that error-related activity in the Nacc preceded surface activity by 40 ms. We propose that the Nacc is involved in action monitoring, possibly by using error signals from the dopaminergic midbrain to adjust the relative impact of limbic and prefrontal inputs on frontal control systems in order to optimize goal-directed behavior.