991 resultados para Skin Permeability Coefficients
Resumo:
In this experimental study the permeability of Australian bagasse chemical pulps obtained from different bagasse fractions were measured in a simple permeability cell and the results compared to one another as well as to eucalypt, Argentinean bagasse and pine pulps. The pulps were characterised in terms of the permeability parameters, the specific surface area, Sv, and the swelling factor, α. It was found that the bagasse fraction used affects these parameters. Fractionation of whole bagasse prior to pulping produced pulps that have permeability properties that compare favourably with eucalypt pulp. The values of Sv and α for bagasse pulp also depend on whether a constant or a variable Kozeny factor is used.
Resumo:
It has previously been found that complexes comprised of vitronectin and growth factors (VN:GF) enhance keratinocyte protein synthesis and migration. More specifically, these complexes have been shown to significantly enhance the migration of dermal keratinocytes derived from human skin. In view of this, it was thought that these complexes may hold potential as a novel therapy for healing chronic wounds. However, there was no evidence indicating that the VN:GF complexes would retain their effect on keratinocytes in the presence of chronic wound fluid. The studies in this thesis demonstrate for the first time that the VN:GF complexes not only stimulate proliferation and migration of keratinocytes, but also these effects are maintained in the presence of chronic wound fluid in a 2-dimensional (2-D) cell culture model. Whilst the 2-D culture system provided insights into how the cells might respond to the VN:GF complexes, this investigative approach is not ideal as skin is a 3-dimensional (3-D) tissue. In view of this, a 3-D human skin equivalent (HSE) model, which reflects more closely the in vivo environment, was used to test the VN:GF complexes on epidermopoiesis. These studies revealed that the VN:GF complexes enable keratinocytes to migrate, proliferate and differentiate on a de-epidermalised dermis (DED), ultimately forming a fully stratified epidermis. In addition, fibroblasts were seeded on DED and shown to migrate into the DED in the presence of the VN:GF complexes and hyaluronic acid, another important biological factor in the wound healing cascade. This HSE model was then further developed to enable studies examining the potential of the VN:GF complexes in epidermal wound healing. Specifically, a reproducible partial-thickness HSE wound model was created in fully-defined media and monitored as it healed. In this situation, the VN:GF complexes were shown to significantly enhance keratinocyte migration and proliferation, as well as differentiation. This model was also subsequently utilized to assess the wound healing potential of a synthetic fibrin-like gel that had previously been demonstrated to bind growth factors. Of note, keratinocyte re-epitheliasation was shown to be markedly improved in the presence of this 3-D matrix, highlighting its future potential for use as a delivery vehicle for the VN:GF complexes. Furthermore, this synthetic fibrin-like gel was injected into a 4 mm diameter full-thickness wound created in the HSE, both keratinocytes and fibroblasts were shown to migrate into this gel, as revealed by immunofluorescence. Interestingly, keratinocyte migration into this matrix was found to be dependent upon the presence of the fibroblasts. Taken together, these data indicate that reproducible wounds, as created in the HSEs, provide a relevant ex vivo tool to assess potential wound healing therapies. Moreover, the models will decrease our reliance on animals for scientific experimentation. Additionally, it is clear that these models will significantly assist in the development of novel treatments, such as the VN:GF complexes and the synthetic fibrin-like gel described herein, ultimately facilitating their clinical trial in the treatment of chronic wounds.
Resumo:
Aims – To develop local contemporary coefficients for the Trauma Injury Severity Score in New Zealand, TRISS(NZ), and to evaluate their performance at predicting survival against the original TRISS coefficients. Methods – Retrospective cohort study of adults who sustained a serious traumatic injury, and who survived until presentation at Auckland City, Middlemore, Waikato, or North Shore Hospitals between 2002 and 2006. Coefficients were estimated using ordinary and multilevel mixed-effects logistic regression models. Results – 1735 eligible patients were identified, 1672 (96%) injured from a blunt mechanism and 63 (4%) from a penetrating mechanism. For blunt mechanism trauma, 1250 (75%) were male and average age was 38 years (range: 15-94 years). TRISS information was available for 1565 patients of whom 204 (13%) died. Area under the Receiver Operating Characteristic (ROC) curves was 0.901 (95%CI: 0.879-0.923) for the TRISS(NZ) model and 0.890 (95% CI: 0.866-0.913) for TRISS (P<0.001). Insufficient data were available to determine coefficients for penetrating mechanism TRISS(NZ) models. Conclusions – Both TRISS models accurately predicted survival for blunt mechanism trauma. However, TRISS(NZ) coefficients were statistically superior to TRISS coefficients. A strong case exists for replacing TRISS coefficients in the New Zealand benchmarking software with these updated TRISS(NZ) estimates.
Resumo:
Background: Blood for transfusion may become contaminated at any point between collection and transfusion and may result in bacteraemia (the presence of bacteria in the blood),severe illness or even death for the blood recipient. Donor arm skin is one potential source of blood contamination, so it is usual to cleanse the skin with an antiseptic before blood donation. One-step and two-step alcohol based antiseptic regimens are both commonly advocated but there is uncertainty as to which is most effective.----- Objectives: To assess the effects of cleansing the skin of blood donors with alcohol in a one-step compared with alcohol in a two-step procedure to prevent contamination of collected blood or bacteraemia in the recipient.----- Search strategy: We searched the Cochrane Wounds Group Specialised Register (March 10 2009); The Cochrane Central Register of Controlled Trials(CENTRAL) The Cochrane Library 2009, Issue 1; Ovid MEDLINE - (1950 to February Week 4 2009); Ovid EMBASE - (1980 to 2009 Week 9); and EBSCO CINAHL - (1982 to February Week 4 2009). We also searched the reference lists of key papers.----- Selection criteria: All randomised trials (RCTs) comparing alcohol based donor skin cleansing in a one-step versus a two-step process that includes alcohol and any other antiseptic for pre-venepuncture skin cleansing were considered. Quasi randomised trials were to have been considered in the absence of RCTs.----- Data collection and analysis: Two review authors independently assessed studies for inclusion.----- Main results: No studies (RCTs or quasi RCTs) met the inclusion criteria. Authors’ conclusions We did not identify any eligible studies for inclusion in this review. It is therefore unclear whether a two-step, alcohol followed by antiseptic skin cleansing process prior to blood donation confers any reduction in the risk of blood contamination or bacteraemia in blood recipients, or conversely whether a one-step process increases risk above that associated with a two-step process.
Resumo:
Survival from melanoma is strongly related to tumour thickness, thus earlier diagnosis has the potential to reduce mortality from this disease. However, in the absence of conclusive evidence that clinical skin examination reduces mortality, evidence-based assessments do not recommend population screening. We aimed to assess whether clinical whole-body skin examination is associated with a reduced incidence of thick melanoma and also whether screening is associated with an increased incidence of thin lesions (possible overdiagnosis). A population-based case-control study of all Queensland residents aged 20-75 years with a histologically confirmed first primary invasive cutaneous melanoma diagnosed between January 2000 and December 2003. Telephone interviews were completed by 3,762 eligible cases (78.0%) and 3,824 eligible controls (50.4%) Whole-body clinical skin examination in the three years before diagnosis was associated with a 14% lower risk of being diagnosed with a thick melanoma (>0.75mm) (OR= 0.86, 95% CI=0.75, 0.98). Risk decreased for melanomas of increasing thickness: the risk of being diagnosed with a melanoma 0.76-1.49mm was reduced by 7% (OR=0.93, 95% CI 0.79, 1.10), by 17% for melanomas 1.50-2.99mm (OR=0.83, 95% CI=0.65, 1.05) and by 40% for melanomas ≥3mm (OR=0.60, 95% CI=0.43, 0.83). Screening was associated with a 38% higher risk of being diagnosed with a thin invasive melanoma (≤0.75mm) (OR=1.38, 95% CI=1.22, 1.56). This is the strongest evidence to date that whole-body clinical skin examination reduces the incidence of thick melanoma. Because survival from melanoma is strongly related to tumour thickness, these results suggest that screening would reduce melanoma mortality.
Resumo:
This is an experimental study into the permeability and compressibility properties of bagasse pulp pads. Three experimental rigs were custom-built for this project. The experimental work is complemented by modelling work. Both the steady-state and dynamic behaviour of pulp pads are evaluated in the experimental and modelling components of this project. Bagasse, the fibrous residue that remains after sugar is extracted from sugarcane, is normally burnt in Australia to generate steam and electricity for the sugar factory. A study into bagasse pulp was motivated by the possibility of making highly value-added pulp products from bagasse for the financial benefit of sugarcane millers and growers. The bagasse pulp and paper industry is a multibillion dollar industry (1). Bagasse pulp could replace eucalypt pulp which is more widely used in the local production of paper products. An opportunity exists for replacing the large quantity of mainly generic paper products imported to Australia. This includes 949,000 tonnes of generic photocopier papers (2). The use of bagasse pulp for paper manufacture is the main application area of interest for this study. Bagasse contains a large quantity of short parenchyma cells called ‘pith’. Around 30% of the shortest fibres are removed from bagasse prior to pulping. Despite the ‘depithing’ operations in conventional bagasse pulp mills, a large amount of pith remains in the pulp. Amongst Australian paper producers there is a perception that the high quantity of short fibres in bagasse pulp leads to poor filtration behaviour at the wet-end of a paper machine. Bagasse pulp’s poor filtration behaviour reduces paper production rates and consequently revenue when compared to paper production using locally made eucalypt pulp. Pulp filtration can be characterised by two interacting factors; permeability and compressibility. Surprisingly, there has previously been very little rigorous investigation into neither bagasse pulp permeability nor compressibility. Only freeness testing of bagasse pulp has been published in the open literature. As a result, this study has focussed on a detailed investigation of the filtration properties of bagasse pulp pads. As part of this investigation, this study investigated three options for improving the permeability and compressibility properties of Australian bagasse pulp pads. Two options for further pre-treating depithed bagasse prior to pulping were considered. Firstly, bagasse was fractionated based on size. Two bagasse fractions were produced, ‘coarse’ and ‘medium’ bagasse fractions. Secondly, bagasse was collected after being processed on two types of juice extraction technology, i.e. from a sugar mill and from a sugar diffuser. Finally one method of post-treating the bagasse pulp was investigated. The effects of chemical additives, which are known to improve freeness, were also assessed for their effect on pulp pad permeability and compressibility. Pre-treated Australian bagasse pulp samples were compared with several benchmark pulp samples. A sample of commonly used kraft Eucalyptus globulus pulp was obtained. A sample of depithed Argentinean bagasse, which is used for commercial paper production, was also obtained. A sample of Australian bagasse which was depithed as per typical factory operations was also produced for benchmarking purposes. The steady-state pulp pad permeability and compressibility parameters were determined experimentally using two purpose-built experimental rigs. In reality, steady-state conditions do not exist on a paper machine. The permeability changes as the sheet compresses over time. Hence, a dynamic model was developed which uses the experimentally determined steady-state permeability and compressibility parameters as inputs. The filtration model was developed with a view to designing pulp processing equipment that is suitable specifically for bagasse pulp. The predicted results of the dynamic model were compared to experimental data. The effectiveness of a polymeric and microparticle chemical additives for improving the retention of short fibres and increasing the drainage rate of a bagasse pulp slurry was determined in a third purpose-built rig; a modified Dynamic Drainage Jar (DDJ). These chemical additives were then used in the making of a pulp pad, and their effect on the steady-state and dynamic permeability and compressibility of bagasse pulp pads was determined. The most important finding from this investigation was that Australian bagasse pulp was produced with higher permeability than eucalypt pulp, despite a higher overall content of short fibres. It is thought this research outcome could enable Australian paper producers to switch from eucalypt pulp to bagasse pulp without sacrificing paper machine productivity. It is thought that two factors contributed to the high permeability of the bagasse pulp pad. Firstly, thicker cell walls of the bagasse pulp fibres resulted in high fibre stiffness. Secondly, the bagasse pulp had a large proportion of fibres longer than 1.3 mm. These attributes helped to reinforce the pulp pad matrix. The steady-state permeability and compressibility parameters for the eucalypt pulp were consistent with those found by previous workers. It was also found that Australian pulp derived from the ‘coarse’ bagasse fraction had higher steady-state permeability than the ‘medium’ fraction. However, there was no difference between bagasse pulp originating from a diffuser or a mill. The bagasse pre-treatment options investigated in this study were not found to affect the steady-state compressibility parameters of a pulp pad. The dynamic filtration model was found to give predictions that were in good agreement with experimental data for pads made from samples of pretreated bagasse pulp, provided at least some pith was removed prior to pulping. Applying vacuum to a pulp slurry in the modified DDJ dramatically reduced the drainage time. At any level of vacuum, bagasse pulp benefitted from chemical additives as quantified by reduced drainage time and increased retention of short fibres. Using the modified DDJ, it was observed that under specific conditions, a benchmark depithed bagasse pulp drained more rapidly than the ‘coarse’ bagasse pulp. In steady-state permeability and compressibility experiments, the addition of chemical additives improved the pad permeability and compressibility of a benchmark bagasse pulp with a high quantity of short fibres. Importantly, this effect was not observed for the ‘coarse’ bagasse pulp. However, dynamic filtration experiments showed that there was also a small observable improvement in filtration for the ‘medium’ bagasse pulp. The mechanism of bagasse pulp pad consolidation appears to be by fibre realignment. Chemical additives assist to lubricate the consolidation process. This study was complemented by pulp physical and chemical property testing and a microscopy study. In addition to its high pulp pad permeability, ‘coarse’ bagasse pulp often (but not always) had superior physical properties than a benchmark depithed bagasse pulp.
Resumo:
Engineering assets are often complex systems. In a complex system, components often have failure interactions which lead to interactive failures. A system with interactive failures may lead to an increased failure probability. Hence, one may have to take the interactive failures into account when designing and maintaining complex engineering systems. To address this issue, Sun et al have developed an analytical model for the interactive failures. In this model, the degree of interaction between two components is represented by interactive coefficients. To use this model for failure analysis, the related interactive coefficients must be estimated. However, methods for estimating the interactive coefficients have not been reported. To fill this gap, this paper presents five methods to estimate the interactive coefficients including probabilistic method; failure data based analysis method; laboratory experimental method; failure interaction mechanism based method; and expert estimation method. Examples are given to demonstrate the applications of the proposed methods. Comparisons among these methods are also presented.
Resumo:
Background: Incidence and mortality from skin cancers including melanoma are highest among men 50 years or older. Thorough skin self-examination may be beneficial to improve skin cancers outcomes.--------- Objectives: To develop and conduct a randomized-controlled trial of a video-based intervention to improve skin self-examination behavior among men 50 years or older.--------- Methods: Pilot work ascertained appropriate targeting of the 12-minute intervention video towards men 50 years or older. Overall, 968 men were recruited and 929 completed baseline telephone assessment. Baseline analysis assessed randomization balance and demographic, skin cancer risk and attitudinal factors associated with conducting a whole-body skin self-examination or receiving a whole-body clinical skin examination by a doctor during the past 12 months.--------- Results: Randomization resulted in well-balanced intervention and control groups. Overall 13% of men reported conducting a thorough skin self-examination using a mirror or the help of another person to check difficult to see areas, while 39% reported having received a whole-body skin examination by a doctor within the past 12 months. Confidence in finding time for and receiving advice or instructions by a doctor to perform a skin self-examination were among the factors associated with thorough skin self-examination at baseline.---------- Conclusions: Men 50 years or older can successfully be recruited to a video-based intervention trial with the aim reduce their burden through skin cancer. Randomization by computer generated randomization list resulted in good balance between control and intervention group and baseline analysis determined factors associated with skin cancer early detection behavior at baseline.
Resumo:
Background: Currently used Trauma and Injury Severity Score (TRISS) coefficients, which measure probability of survival (Ps), were derived from the Major Trauma Outcome Study (MTOS) in 1995 and are now unlikely to be optimal. This study aims to estimate new TRISS coefficients using a contemporary database of injured patients presenting to emergency departments in the United States; and to compare these against the MTOS coefficients.---------- Methods: Data were obtained from the National Trauma Data Bank (NTDB) and the NTDB National Sample Project (NSP). TRISS coefficients were estimated using logistic regression. Separate coefficients were derived from complete case and multistage multiple imputation analyses for each NTDB and NSP dataset. Associated Ps over Injury Severity Score values were graphed and compared by age (adult ≥ 15 years; pediatric < 15 years) and injury mechanism (blunt; penetrating) groups. Area under the Receiver Operating Characteristic curves was used to assess coefficients’ predictive performance.---------- Results: Overall 1,072,033 NTDB and 1,278,563 weighted NSP injury events were included, compared with 23,177 used in the original MTOS analyses. Large differences were seen between results from complete case and imputed analyses. For blunt mechanism and adult penetrating mechanism injuries, there were similarities between coefficients estimated on imputed samples, and marked divergences between associated Ps estimated and those from the MTOS. However, negligible differences existed between area under the receiver operating characteristic curves estimates because the overwhelming majority of patients had minor trauma and survived. For pediatric penetrating mechanism injuries, variability in coefficients was large and Ps estimates unreliable.---------- Conclusions: Imputed NTDB coefficients are recommended as the TRISS coefficients 2009 revision for blunt mechanism and adult penetrating mechanism injuries. Coefficients for pediatric penetrating mechanism injuries could not be reliably estimated.
Resumo:
To assess the effects of any interventions which aim to prevent or manage radiation-induced skin reactions in people with cancer.