927 resultados para Single-family homes
Resumo:
The literature on residences and citizens’ transports has focused on either reforming traffic managing in response to residential relocation or post-evaluation of urban planning policies or the evolution of the urban spatial form. In a city there are hotspots that attract the citizens and most of the transportation in the city arises as the citizens’ movement between their residence and the hotspots. Little scholarly attention has been devoted to the possibility to minimize citizens’ transportation in the city by the urban planning of residential areas. In this paper we propose a method to evaluate the environmental impact (in terms of CO2-emissions) of urban plans of residential areas. The method is illustrated in a Swedish case of a midsize city which is presently preoccupied with urban planning of new residential areas in response to substantial population growth due to immigration. The residential plans aims to increase the compactness and residential density in the current center and sub centers leads to less CO2 emissions compare to urban expansion to the edge of the city. The plans of concentrated apartment buildings are more effective in meeting residential needs and mitigating CO2 emissions than dispersed single-family houses.
Resumo:
Energy auditing can be an important contribution for identification and assessment of energy conservation measures (ECMs) in buildings. Numerous tools and software have been developed, with varying degree of precision and complexity and different areas of use. This paper evaluates PHPP as a versatile, easy-to-use energy auditing tool and gives examples of how it has been compared to a dynamic simulation tool, within the EU-project iNSPiRe. PHPP is a monthly balance energy calculation tool based on EN13790. It is intended for assisting the design of Passive Houses and energy renovation projects and as guidance in the choice of appropriate ECMs. PHPP was compared against the transient simulation software TRNSYS for a single family house and a multi-family house. It should be mentioned that dynamic building simulations might strongly depend on the model assumptions and simplifications compared to reality, such as ideal heating or real heat emission system. Setting common boundary conditions for both PHPP and TRNSYS, the ideal heating and cooling loads and demands were compared on monthly and annual basis for seven European locations and buildings with different floor area, S/V ratio, U-values and glazed area of the external walls. The results show that PHPP can be used to assess the heating demand of single-zone buildings and the reduction of heating demand with ECMs with good precision. The estimation of cooling demand is also acceptable if an appropriate shading factor is applied in PHPP. In general, PHPP intentionally overestimates heating and cooling loads, to be on the safe side for system sizing. Overall, the agreement with TRNSYS is better in cases with higher quality of the envelope as in cold climates and for good energy standards. As an energy auditing tool intended for pre-design it is a good, versatile and easy-to-use alternative to more complex simulation tools.
Resumo:
the work towards increased energy efficiency. In order to plan and perform effective energy renovation of the buildings, it is necessary to have adequate information on the current status of the buildings in terms of architectural features and energy needs. Unfortunately, the official statistics do not include all of the needed information for the whole building stock. This paper aims to fill the gaps in the statistics by gathering data from studies, projects and national energy agencies, and by calibrating TRNSYS models against the existing data to complete missing energy demand data, for countries with similar climate, through simulation. The survey was limited to residential and office buildings in the EU member states (before July 2013). This work was carried out as part of the EU FP7 project iNSPiRe. The building stock survey revealed over 70% of the residential and office floor area is concentrated in the six most populated countries. The total energy consumption in the residential sector is 14 times that of the office sector. In the residential sector, single family houses represent 60% of the heated floor area, albeit with different share in the different countries, indicating that retrofit solutions cannot be focused only on multi-family houses. The simulation results indicate that residential buildings in central and southern European countries are not always heated to 20 °C, but are kept at a lower temperature during at least part of the day. Improving the energy performance of these houses through renovation could allow the occupants to increase the room temperature and improve their thermal comfort, even though the potential for energy savings would then be reduced.
Resumo:
This research has as its object study focus bioclimatic in architecture and its conection with projects decisions, on what regards to environmental comfort for single-family dwelling. From the analysis of five architectural projects inserted in Natal/RN, warm-moist weather, this research gather informations regarding architectural features guided by shape and space arrengement, which embody important elements for the project design development. Computer simulations assisted as foundation to verify the efficiency grade for these projects strategies from shading analysis. Related strategies for the demands of natural ventilation circulation and thermal mass for refrigeration were analysed as well. Results show that there is an hierarchizing of priorities for the decisions made when it comes to shape and space disposition variables, as well as the way these variables will consider the bioclimatic demands. The analysis, even, show that there is no single way to respond to specific bioclimatic demands, as it points out the value of examination of the projectual solutions throughtout the conception process, in order to achieve an efficient project performance for the envimonment comfort
Resumo:
Assuming that the form of a building shell and its content the spatial form are distinct dimensions of architecture - however indivisible and interdependent -, this study focus, in the light of the Social Logic of Space (HILLIER; HANSON, 1984), on the intrinsic properties through which domestic space was structured in a sample of single-family dwellings built in João Pessoa (PB) during the 1970s - when the vocabulary of modern architecture still prevailed in Brazil though sharing the urban scene with other architectural trends -, in order to investigate regularities or divergences underlying their conception. These dwellings were originally classified (ARAÚJO, 2010a) in five categories defined according to the form of their building shells and to their prevailing construction techniques: (1) Brazilian modern legacy (considered as truly Brazilian modern style); (2) Paulista architecture (that refers to the modern production of São Paulo, Brazil, from the 1950s through the 1970s); (3) experiences of rationalization and prefabrication ; (4) experiences of adaptation to the climate (referring to a design strongly influenced by the hot and humid climate of North-eastern Brazil); and (5) hybrid (to account for a kind of stylistic hybridism that includes formal attributes, which evoke our colonial past). This study aims to determine, through the analyses of nineteen cases that represent each category, whether this taxonomy corresponds to distinct modes of spatial configuration. This research therefore proposes an approach to the classification of domestic architecture based on topological properties. The dwellings spatial organization was represented, quantified and analyzed, their spatial properties explored in consonance with one another and with the literature. Results pointed out that there is no evidence of a reciprocal relationship between the formal look of the built shells and their respective spatial structures
Resumo:
Aim This paper will report findings from the first phase of an evaluation of a new e-health intervention designed to allow mothers to ‘see’ their baby in neonatal care (NNU) when they are not able to be with them. The intervention, MyLittleOne, involves a web-camera being placed over the incubator in NNU, which transmits a real-time video wirelessly to a coupled tablet device at the mother’s bedside. Guided by the MRC Framework for the Development and Evaluation of Healthcare Interventions (MRC, 2008), the aim was to explore parent and professional views of the technology and make recommendations for its future development, use and evaluation. Methods A qualitative approach was adopted, guided by a critical realist perspective (McEvoy and Richards, 2003). The study took place in a Level 3 NNU in Scotland. Participants were recruited purposively and included parents (n = 33) and a range of health professionals working in neonatal and postnatal care (n = 21). The data were collected during semi-structured individual, paired and small group interviews and were analysed thematically using NVivo v10. Results The majority of parents and professionals spoke positively about MyLittleOne. Perceptions were that: use of the technology assisted bonding and responsiveness; it promoted the recovery process following birth; and, for mothers who wished to breast-feed, being able to see their baby on the tablet device encouraged the ‘let-down’ reflex. An additional benefit was that siblings and others who may not be able to visit the NNU were able to see the baby. In contrast, for a small number of mothers, viewing their baby remotely appeared to increase their levels of anxiety. Switching off the camera during a medical procedure and back on after the procedure was completed was found to be problematic, at times and in different ways, for both parents and professionals. Conclusions Findings from this preliminary evaluation will guide future developments of the technology, including its use in family homes following the mother’s discharge. The findings will also inform the design of a feasibility study and subsequent RCT to assess the impact of MyLittleOne on a range of psychological indicators of postnatal adjustment.
Resumo:
A presente dissertação centra-se no estudo das implicações originadas, ao nível das soluções construtivas presentes na envolvente dos edifícios de habitação, pelas recentes alterações efetuadas ao Regulamento de Desempenho Energético de Edifícios de Habitação (REH). Com o intuito de aferir o desempenho energético, através da aplicação do REH, considerou-se como caso de estudo um edifício de habitação novo, unifamiliar com tipologia T3, localizado a cerca de 10 metros acima do nível médio das águas do mar e na periferia da zona urbana de Vila Nova de Gaia. Após o levantamento das necessidades energéticas do edifício em estudo, realizaram-se diversas simulações, com o intuito de identificar e quantificar as alterações provocadas pela entrada em vigor da Portaria 379-A/2015, de 22 de outubro. Inicialmente estudou-se o comportamento térmico da habitação unifamiliar admitindo diferentes soluções construtivas: as soluções que cumpriam com as exigências em vigor até ao final de 2015 e as que cumprem as imposições atuais. Desta forma tentou perceber-se quais as implicações dessas alterações nas necessidades energéticas da habitação. Em seguida, e utilizando o mesmo conceito da simulação inicial, fez-se um estudo considerando que a fração se situava nas diferentes zonas climáticas existentes em Portugal. Para que tal fosse possível, teve que se considerar a implantação da habitação em diferentes localizações geográficas e a diferentes altitudes. Também se procurou avaliar a importância que as pontes térmicas planas assumem nas transferências de calor, nas duas estações. Assim, foi necessário fazer um pré- dimensionamento da solução estrutural adotada, quantificar a área destes elementos e o respetivo coeficiente de transmissão. Quantificou-se, posteriormente, quais as necessidades energéticas obtidas com a solução estrutural perfeitamente definida e as que se obteriam se se desprezasse a sua existência. Com as análises comparativas dos diferentes resultados obtidos, verificou-se que as atualizações das exigências regulamentares a que os edifícios de habitação estão sujeitos originam grande impacto nos sistemas construtivos adotados.
Resumo:
Good schools are essential for building thriving urban areas. They are important for preparing the future human resource and directly contribute to social and economic development of a place. They not only act as magnets for prospective residents, but also are necessary for retaining current population. As public infrastructure, schools mirror their neighborhood. “Their location, design and physical condition are important determinants of neighborhood quality, regional growth and change, and quality of life.”2 They impact housing development and utility requirements among many things. Hence, planning for schools along with other infrastructure in an area is essential. Schools are very challenging to plan, especially in urbanizing areas with changing demographic dynamics, where the development market and housing development can shift drastically a number of times. In such places projecting the future school enrollments is very difficult and in case of large population influx, school development can be unable to catch up with population growth which results in overcrowding. Typical is the case of Arlington County VA. In the past two decades the County has changed dramatically from a collection of bedroom communities in Washington DC Metro Region to a thriving urban area. Its metro accessible urban corridors are among most desired locations for development in the region. However, converting single family neighborhoods into high density areas has put a lot of pressure on its school facilities and has resulted in overcrowded schools. Its public school enrollment has grown by 19% from 2009 to 2014.3 While the percentage of population under 5 years age has increased in last 10 years, those in the 5-19 age group have decreased4. Hence, there is more pressure on the elementary school facilities than others in the County. Design-wise, elementary schools, due to their size, can be imagined as a community component. There are a number of strategies that can be used to develop elementary school in urbanizing areas as a part of the neighborhood. Experimenting with space planning and building on partnership and mixed-use opportunities can help produce better designs for new schools in future. This thesis is an attempt to develop elementary school models for urbanizing areas of Arlington County. The school models will be designed keeping in mind the shifting nature of population and resulting student enrollments in these areas. They will also aim to be efficient and sustainable, and lead to the next generation design for elementary school education. The overall purpose of the project is to address barriers to elementary school development in urbanizing areas through creative design and planning strategies. To test above mentioned ideas, the Joint-Use School typology of housing +school design has been identified for elementary school development in urbanizing areas in this thesis project. The development is based on the Arlington Public School’s Program guidelines (catering to 600 students). The site selected for this project is Clarendon West (part of Red Top Cab Properties) in Clarendon, Arlington County VA.
Resumo:
This research has as its object study focus bioclimatic in architecture and its conection with projects decisions, on what regards to environmental comfort for single-family dwelling. From the analysis of five architectural projects inserted in Natal/RN, warm-moist weather, this research gather informations regarding architectural features guided by shape and space arrengement, which embody important elements for the project design development. Computer simulations assisted as foundation to verify the efficiency grade for these projects strategies from shading analysis. Related strategies for the demands of natural ventilation circulation and thermal mass for refrigeration were analysed as well. Results show that there is an hierarchizing of priorities for the decisions made when it comes to shape and space disposition variables, as well as the way these variables will consider the bioclimatic demands. The analysis, even, show that there is no single way to respond to specific bioclimatic demands, as it points out the value of examination of the projectual solutions throughtout the conception process, in order to achieve an efficient project performance for the envimonment comfort
Resumo:
Assuming that the form of a building shell and its content the spatial form are distinct dimensions of architecture - however indivisible and interdependent -, this study focus, in the light of the Social Logic of Space (HILLIER; HANSON, 1984), on the intrinsic properties through which domestic space was structured in a sample of single-family dwellings built in João Pessoa (PB) during the 1970s - when the vocabulary of modern architecture still prevailed in Brazil though sharing the urban scene with other architectural trends -, in order to investigate regularities or divergences underlying their conception. These dwellings were originally classified (ARAÚJO, 2010a) in five categories defined according to the form of their building shells and to their prevailing construction techniques: (1) Brazilian modern legacy (considered as truly Brazilian modern style); (2) Paulista architecture (that refers to the modern production of São Paulo, Brazil, from the 1950s through the 1970s); (3) experiences of rationalization and prefabrication ; (4) experiences of adaptation to the climate (referring to a design strongly influenced by the hot and humid climate of North-eastern Brazil); and (5) hybrid (to account for a kind of stylistic hybridism that includes formal attributes, which evoke our colonial past). This study aims to determine, through the analyses of nineteen cases that represent each category, whether this taxonomy corresponds to distinct modes of spatial configuration. This research therefore proposes an approach to the classification of domestic architecture based on topological properties. The dwellings spatial organization was represented, quantified and analyzed, their spatial properties explored in consonance with one another and with the literature. Results pointed out that there is no evidence of a reciprocal relationship between the formal look of the built shells and their respective spatial structures
Resumo:
Tradicionalmente la vivienda social en México ha sido analizada de manera cuantitativa principalmente en cuanto al déficit y el rezago, omitiendo la aportación que el uso de esas viviendas ofrece al bienestar de sus ocupantes. Este artículo presenta a la "vivienda VITAL" como propuesta de vivienda unifamiliar con espacio interior dirigido al bienestar de su usuario, con base en una investigación1 cualitativa que incluyó a usuarios de vivienda de interés social ubicados en tres desarrollos habitacionales en el Área Metropolitana de Monterrey, Nuevo León, y a funcionarios públicos dedicados al diseño y ejecución de vivienda social en México. ABSTRACT Traditionally social housing in Mexico has been analyzed quantitatively mainly in regards to deficit and backlog, omitting the contribution that the usage of these houses offers to the welfare of their habitants. This article introduces the "housing VITAL" as a proposal for a single family housing with interior space focused to the welfare of its user, based on a qualitative research that included low income housing users in three housing developments located at the Metropolitan Area of Monterrey, Nuevo León, and public servants dedicated to the design and implementation of social housing in Mexico
Resumo:
Property taxes serve as a vital revenue source for local governments. The revenues derived from the property tax function as the primary funding source for a variety of critical local public service systems. Property tax appeal systems serve as quasi-administrative-judicial mechanisms intended to assure the public that property tax assessments are correct, fair, and equitable. Despite these important functions, there is a paucity of empirical research related to property tax appeal systems. This study contributes to property tax literature by identifying who participates in the property tax appeal process and examining their motivations for participation. In addition, the study sought to determine whether patterns of use and success in appeal systems affected the distribution of the tax burden. Data were collected by means of a survey distributed to single-family property owners from two Florida counties. In addition, state and county documents were analyzed to determine appeal patterns and examine the impact on assessment uniformity, over a three-year period. The survey data provided contextual evidence that single-family property owners are not as troubled by property taxes as they are by the conduct of local government officials. The analyses of the decision to appeal indicated that more expensive properties and properties excluded from initial uniformity analyses were more likely to be appealed, while properties with homestead exemptions were less likely to be appealed. The value change analyses indicated that appeals are clustered in certain geographical areas; however, these areas do not always experience a greater percentage of the value changes. Interestingly, professional representation did not increase the probability of obtaining a reduction in value. Other relationships between the variables were discovered, but often with weak predictive ability. Findings from the assessment uniformity analyses were also interesting. The results indicated that the appeals mechanisms in both counties improved assessment uniformity. On average, appealed properties exhibited greater horizontal and vertical inequities, as compared to non-appealed properties, prior to the appeals process. After, the appeal process was completed; the indicators of horizontal and vertical equity were largely improved. However, there were some indications of regressivity in the final year of the study.
Resumo:
Performance testing methods of boilers in transient operating conditions (start, stop and combustion power modulation sequences) need the combustion rate quantified to allow for the emissions to be quantified. One way of quantifying the combustion rate of a boiler during transient operating conditions is by measuring the flue gas flow rate. The flow conditions in chimneys of single family house boilers pose a challenge however, mainly because of the low flow velocity. The main objectives of the work were to characterize the flow conditions in residential chimneys, to evaluate the use of the Pitot-static method and the averaging Pitot method, and to develop and test a calibration method for averaging Pitot probes for low
Resumo:
Accounting for around 40% of the total final energy consumption, the building stock is an important area of focus on the way to reaching the energy goals set for the European Union. The relatively small share of new buildings makes renovation of existing buildings possibly the most feasible way of improving the overall energy performance of the building stock. This of course involves improvements on the climate shell, for example by additional insulation or change of window glazing, but also installation of new heating systems, to increase the energy efficiency and to fit the new heat load after renovation. In the choice of systems for heating, ventilation and air conditioning (HVAC), it is important to consider their performance for space heating as well as for domestic hot water (DHW), especially for a renovated house where the DHW share of the total heating consumption is larger. The present study treats the retrofitting of a generic single family house, which was defined as a reference building in a European energy renovation project. Three HVAC retrofitting options were compared from a techno-economic point of view: A) Air-to-water heat pump (AWHP) and mechanical ventilation with heat recovery (MVHR), B) Exhaust air heat pump (EAHP) with low-temperature ventilation radiators, and C) Gas boiler and ventilation with MVHR. The systems were simulated for houses with two levels of heating demand and four different locations: Stockholm, Gdansk, Stuttgart and London. They were then evaluated by means of life cycle cost (LCC) and primary energy consumption. Dynamic simulations were done in TRNSYS 17. In most cases, system C with gas boiler and MVHR was found to be the cheapest retrofitting option from a life cycle perspective. The advantage over the heat pump systems was particularly clear for a house in Germany, due to the large discrepancy between national prices of natural gas and electricity. In Sweden, where the price difference is much smaller, the heat pump systems had almost as low or even lower life cycle costs than the gas boiler system. Considering the limited availability of natural gas in Sweden, systems A and B would be the better options. From a primary energy point of view system A was the best option throughout, while system B often had the highest primary energy consumption. The limited capacity of the EAHP forced it to use more auxiliary heating than the other systems did, which lowered its COP. The AWHP managed the DHW load better due to a higher capacity, but had a lower COP than the EAHP in space heating mode. Systems A and C were notably favoured by the air heat recovery, which significantly reduced the heating demand. It was also seen that the DHW share of the total heating consumption was, as expected, larger for the house with the lower space heating demand. This confirms the supposition that it is important to include DHW in the study of HVAC systems for retrofitting.
Resumo:
In this paper, dynamic simulation was used to compare the energy performance of three innovativeHVAC systems: (A) mechanical ventilation with heat recovery (MVHR) and micro heat pump, (B) exhaustventilation with exhaust air-to-water heat pump and ventilation radiators, and (C) exhaust ventilationwith air-to-water heat pump and ventilation radiators, to a reference system: (D) exhaust ventilation withair-to-water heat pump and panel radiators. System A was modelled in MATLAB Simulink and systems Band C in TRNSYS 17. The reference system was modelled in both tools, for comparison between the two.All systems were tested with a model of a renovated single family house for varying U-values, climates,infiltration and ventilation rates.It was found that A was the best system for lower heating demand, while for higher heating demandsystem B would be preferable. System C was better than the reference system, but not as good as A or B.The difference in energy consumption of the reference system was less than 2 kWh/(m2a) betweenSimulink and TRNSYS. This could be explained by the different ways of handling solar gains, but also bythe fact that the TRNSYS systems supplied slightly more than the ideal heating demand.