938 resultados para Serologic tests and antigen


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The diagnosis of leprosy continues to be based on clinical symptoms and early diagnosis and treatment are critical to preventing disability and transmission. Sensitive and specific laboratory tests are not available for diagnosing leprosy. Despite the limited applicability of anti-phenolic glycolipid-I (PGL-I) serology for diagnosis, it has been suggested as an additional tool to classify leprosy patients (LPs) for treatment purposes. Two formats of rapid tests to detect anti-PGL-I antibodies [ML immunochromatography assay (ICA) and ML Flow] were compared in different groups, multibacillary patients, paucibacillary patients, household contacts and healthy controls in Brazil and Nepal. High ML Flow intra-test concordance was observed and low to moderate agreement between the results of ML ICA and ML Flow tests on the serum of LPs was observed. LPs were "seroclassified" according to the results of these tests and the seroclassification was compared to other currently used classification systems: the World Health Organization operational classification, the bacilloscopic index and the Ridley-Jopling classification. When analysing the usefulness of these tests in the operational classification of PB and MB leprosy for treatment and follow-up purposes, the ML Flow test was the best point-of-care test for subjects in Nepal and despite the need for sample dilution, the ML ICA test yielded better performance among Brazilian subjects. Our results identified possible ways to improve the performance of both tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The polysaccharide antigen from P. brasiliensis has been largely employed in serologic tests, as well as in skin tests, to evaluate cellular immunity. SDS-PAGE analysis of this antigen has revealed a variability in the number of bands exhibited by isolates SN, 265, 339, 113 and 18 (7 to 16 bands). The antigens obtained from isolates 2, PTL, 192 and Adel showed two or three bands. Glycoprotein analysis demonstrated a broad region between 50 and 90 kDa. Major bands of 48 and 30 kDa were present in almost all antigens. Optimal complement fixing dilution appears to be unaffected by the number of bands presented by different antigens. The immunoblot analysis revealed that the 90 and 30 kDa bands were mainly recognized by sera from paracoccidioidomycosis patients. Bands of high molecular weight were also recognized by most of the sera studied. Sera from histoplasmosis recognized the 94 kDa band. In conclusion, although the isolates exhibit quantitative variability in the number of fractions, it is possible to use only one or two samples given the greatest frequency of reactivity is seen in the 30 and 90 kDa fractions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens. METHODS We generated a panel of 43 recombinantly expressed virus-like particles (VLPs), containing the structural Gag proteins of HIV-1 subtypes A-H and circulating recombinant forms (CRF) CRF01_AE, CRF02_AG, CRF12_BF, CRF20_BG and group O. Eleven 4th generation antigen/antibody tests and five antigen-only tests were evaluated for their ability to detect VLPs diluted in human plasma to p24 concentrations equivalent to 50, 10 and 2 IU/ml of the WHO p24 standard. Three tests were also evaluated for their ability to detect p24 after heat-denaturation for immune-complex disruption, a pre-requisite for ultrasensitive p24 detection. RESULTS Our VLP panel exhibited an average intra-clade p24 diversity of 6.7%. Among the 4th generation tests, the Abbott Architect and Siemens Enzygnost Integral 4 had the highest sensitivity of 97.7% and 93%, respectively. Alere Determine Combo and BioRad Access were least sensitive with 10.1% and 40.3%, respectively. Antigen-only tests were slightly more sensitive than combination tests. Almost all tests detected the WHO HIV-1 p24 standard at a concentration of 2 IU/ml, but their ability to detect this input for different subtypes varied greatly. Heat-treatment lowered overall detectability of HIV-1 p24 in two of the three tests, but only few VLPs had a more than 3-fold loss in p24 detection. CONCLUSIONS The HIV-1 Gag subtype panel has a broad diversity and proved useful for a standardised evaluation of the detection limit and breadth of subtype detection of p24 antigen-detecting tests. Several tests exhibited problems, particularly with non-B subtypes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The micro-scale abrasive wear test by rotative ball has gained large acceptance in universities and research centers, being widely used in studies on the abrasive wear of materials. Two wear modes are usually observed in this type of test: ""rolling abrasion"" results when the abrasive particles roll on the surface of the tested specimen, while ""grooving abrasion"" is observed when the abrasive particles slide; the type of wear mode has a significant effect on the overall behaviour of a tribological system. Several works on the friction coefficient during abrasive wear tests are available in the literature, but only a few were dedicated to the friction coefficient in micro-abrasive wear tests conducted with rotating ball. Additionally, recent works have identified that results may also be affected by the change in contact pressure that occurs when tests are conducted with constant applied force. Thus, the purpose of this work is to study the relationship between friction coefficient and abrasive wear modes in ball-cratering wear tests conducted at ""constant normal force"" and ""constant pressure"". Micro-scale abrasive wear tests were conducted with a ball of AISI52100 steel and a specimen of AISIH10 tool steel. The abrasive slurry was prepared with black silicon carbide (SiC) particles (average particle size of 3 mu m) and distilled water. Two constant normal force values and two constant pressure values were selected for the tests. The tangential and normal loads were monitored throughout the tests and their ratio was calculated to provide an indication of the friction coefficient. In all cases, optical microscopy analysis of the worn craters revelated only the presence of grooving abrasion. However, a more detailed analysis conducted by SEM has indicated that different degrees of rolling abrasion have also occurred along the grooves. The results have also shown that: (i) for the selected values of constant normal force and constant pressure, the friction coefficient presents, approximately, the same range of values and (ii) loading conditions play an important role on the occurrence of rolling abrasion or grooving abrasion and, consequently, on the average value and scatter of the friction coefficient in micro-abrasive wear tests. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An antigen capture immunoassay to detect West Nile (WN) virus antigen in infected mosquitoes and avian tissues has been developed. With this assay purified WN virus was detected at a concentration of 32 pg/0.1 ml, and antigen in infected suckling mouse brain and laboratory-infected mosquito pools could be detected when the WN virus titer was 10(2.1) to 10(3.7) PFU/0.1 ml. In a blindly coded set of field-collected mosquito pools (n = 100), this assay detected WN virus antigen in 12 of 18 (66.7%) TaqMan-positive pools, whereas traditional reverse transcriptase PCR detected 10 of 18 (55.5%) positive pools. A sample set of 73 organ homogenates from naturally infected American crows was also examined by WN virus antigen capture immunoassay and TaqMan for the presence of WN virus. The antigen capture assay detected antigen in 30 of 34 (88.2%) TaqMan-positive tissues. Based upon a TaqMan-generated standard curve of infectious WN virus, the limit of detection in the antigen capture assay for avian tissue homogenates was approximately 10(3) PFU/0.1 ml. The recommended WN virus antigen capture protocol, which includes a capture assay followed by a confirmatory inhibition assay used to retest presumptive positive samples, could distinguish between the closely related WN and St. Louis encephalitis viruses in virus-infected mosquito pools and avian tissues. Therefore, this immunoassay demonstrates adequate sensitivity and specificity for surveillance of WN virus activity in mosquito vectors and avian hosts, and, in addition, it is easy to perform and relatively inexpensive compared with the TaqMan assay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: To characterise chronic lateral epicondylalgia using the McGill Pain Questionnaire, Visual Analog Scales for pain and function, and Quantitative Sensory Tests; and to examine the relationship between these tests in a population with chronic lateral epicondylalgia. Method: Fifty-six patients (29 female, 27 male) diagnosed with unilateral lateral epicondylalgia of 18.7 months (mean) duration (range 1-300), with a mean age of 50.7 years (range 27-73) participated in this study. Each participant underwent assessment with the McGill Pain Questionnaire (MPQ), Visual Analog Scales (VAS) for pain and function. and Quantitative Sensory Tests (QST) including thermal and pressure pain thresholds, pain free grip strength, and neuromeningeal tissue testing via the upper limb tension test 2b (ULTT 2b). Results: Moderate correlation (r = .338-.514, p = .000-.013) was found between all indices of the MPQ and VAS for pain experienced in the previous 24 hours and week. Thermal pain threshold was found to be significantly higher in males. A significant poor to moderate correlation was found between the Pain Rating Index (PRI) in the sensory category of the MPQ and ULTT2b scores (r = .353, p = .038). There was no other significant correlation between MPQ and QST data. Pain free grip strength was poorly yet significantly correlated with duration of pathology (r = 318, p = .038). Conclusion: The findings of this study are in agreement with others (Melzack and Katz, 1994) regarding the multidimensional nature of pain, in a condition conventionally conceived as a musculoskeletal pain state. The findings also suggest that utilisation of only one pain measurement tool is unlikely to provide a thorough clinical picture of pain experienced with chronic lateral epicondylalgia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hepatitis B virus (HBV) serological markers were investigated in 40 incident cases of hepatocellular carcinoma (HCC) and in two age and sex matched control groups, comprising 40 patients with other cancers and 80 healthy individuals, resident in Bahia, Brazil. Serologic tests were done by radioimmunoassay. The study observed high proportion of seropositivity to HBsAg (42.5%) and of those presenting HBsAg or antiHBc (65.0%) among HCC cases, higher in men than women and in those aged 17 to 30 years old. HBsAg seropositivity among HCC patients was greater than in the control group with other cancers (7.5%) and in healthy controls (2.5%), corresponding to odds ratio estimates of 15.0 (95% CI 3.29, 68.30) and 33.0 (95% CI 9.13, 119.28), both statistically significant. HBeAg was not observed and antiHBe was present in 41.2% of cases, suggesting the absence of viral replication, possibly with viral DNA intergration into the hepatocyte genome. The presence of cirrhosis was associated with HBsAg seropositivity among HCC cases. A history of chronic alcoholism is shown to be more frequently related to those cases with cirrhosis. This study highlights the relevant association between HCC and HBV in Northeast Brazil, particularly for young individuals, and the high risk of development of HCC for HBsAg carriers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multiple-Choice items are used in many different kinds of tests in several areas of knowledge. They can be considered an interesting tool to the self-assessing or as an alternative or complementary instrument to the traditional methods for assessing knowledge. The objectivity and accuracy of the multiple-choice tests is an important reason to think about. They are especially useful when the number of students to evaluate is too large. Moodle (Modular Object-Oriented Dynamic Learning Environment) is an Open Source course management system centered around learners' needs and designed to support collaborative approaches to teaching and learning. Moodle offers to the users a rich interface, context-specific help buttons, and a wide variety of tools such as discussion forums, wikis, chat, surveys, quizzes, glossaries, journals, grade books and more, that allow them to learn and collaborate in a truly interactive space. Come together the interactivity of the Moodle platform and the objectivity of this kind of tests one can easily build manifold random tests. The proposal of this paper is to relate our journey in the construction of these tests and share our experience in the use of the Moodle platform to create, take advantage and improve the multiple-choices tests in the Mathematic area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Blood donors in Brazil have been routinely screened for HTLV-I/II since 1993. A study was performed to estimate the prevalence of HTLV-I/II infection in a low risk population and to better understand determinants associated with seropositivity. METHODS: HTLV-I/II seropositive (n=135), indeterminate (n=167) and seronegative blood donors (n=116) were enrolled in an open prevalence prospective cohort study. A cross-sectional epidemiological study of positive, indeterminate and seronegative HTLV-I/II subjects was conducted to assess behavioral and environmental risk factors for seropositivity. HTLV-I/II serological status was confirmed using enzyme-linked immunosorbent assay (EIA) and Western blot (WB). RESULTS: The three groups were not homogeneous. HTLV-I/II seropositivity was associated to past blood transfusion and years of schooling, a marker of socioeconomic status, and use of non-intravenous illegal drugs. CONCLUSIONS: The study results reinforce the importance of continuous monitoring and improvement of blood donor selection process.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sera from the patients (N = 10) with schistosomiasis mansoni of the hospital of Federal University of Pernambuco, the Schistosoma mansoni egg-positive (N = 51) and -negative (N = 452) inhabitants in Cabo City area, out-patients (N = 37) of the IMIP hospital and Japanese immigrants (N = 127) in Petrolina City area of northeast Brazil as well as Japanese healthy subjects (N = 30) were examined by serological tests including an enzyme-linked immunosorbent assay with antigens prepared from eggs (ELISA-egg) and adult worms (ELISA-adult). The ELISA with egg or adult antigen correctly identified 100% of the uninfected individuals lived in non-endemic area of schistosomiasis. Moreover, when examined cross-reactivity of our ELISA with sera isolated from 78 subjects infected with various intestinal parasitic infections, only one of these sera reacted with the egg and adult antigens. On the examination of 51 sera from the egg-positive subjects, the ELISA-egg revealed the highest sensitivity (98.0%), whereas a large number of false negative reactions of ELISA-adult, Ouchterlony method using adult antigen, circumoval precipitation and immediate intradermal skin test were observed. A low sensitivity of these serologic tests except for ELISA-egg appears to be primarily due to their inability to detect antibody in the sera from egg-positive infantiles. There was no positive correlation between the absorbance values of these two types of ELISA among the sera isolated from ELISA-positive subjects. Rather, by the reactivity of these sera to egg or adult antigen, they could be divided into two subgroups; one reacted more positively with egg antigen and the other with adult antigen. Moreover, it was confirmed that the sera from young subjects (under 20 years old) appear to be highly reactive to the egg antigen than did aged ones. These data suggest that the ELISA with egg antigen, but not with the adult antigen, appears to be useful for the serological survey of schistosomiasis mansoni in the endemic area of northeast Brazil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is about a design of an urban area Darrieus VAWT, having self-start ability due to an innovative profile design named EN0005, avoiding the need of extra components or external electricity feed-in. An approach is presented to study the ability of a blade profile to offer self-start ability. Methodologies applied for the blade body and for profile development are reported. Field tests and main conclusions are presented to persuade for the arrangement of this design. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Total serum IgE, and Strongyloides - specific IgG and IgA antibodies were studied in 27 patients with parasitologically proven strongyloidiasis. Clinical manifestations in this case series were investigated by a restrospective study of the patient's records. Total serum IgE levels were elevated (greater than 250 IU/ml) in 59% of the patients (mean concentration = 1364 IU/ml). Parasite - specific IgG and IgA antibodies were detected by ELISA in the serum of 23 (85.2%) and 21 (77.8%) patients, respectively. Elevated serum IgE and clinical manifestations were not useful indexes of the presence of strongyloidiasis. On the other hand, our results support the view that serologic tests, particularly ELISA for detecting Strongyloides - specific IgG antibodies, can be usefully exploited for diagnostic purposes in strongyloidiasis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study evaluated six Plasmodium falciparum antigen extracts to be used in the IgG and IgM enzyme-linked immunosorbent assays (ELISA), for malaria diagnosis and epidemiological studies. Results obtained with eighteen positive and nine negative control sera indicated that there were statistically significant differences among these antigen extracts (Multifactor ANOVA, p< 0.0001). Urea, sodium deoxycholate and Zwittergent antigen extracts performed better than did the three others, their features being very similar for the detection of IgG antibodies. Urea, alkaline and sodium deoxycholate antigen extracts proved to be better than the others for the detection of IgM antibodies. A straight line relationship was found between the optical densities (or their respective log 10) and the log 10 of antibody dilutions, with a very constant slope. Thus serum titers could be determined by direct titration and by two different equations, needing only one serum dilution. For IgM antibody detections, log 10 expression gave results that better correlated with direct titration (95% Bonferroni). For IgG antibody detections, the titer differences were not significant. The reproducibility of antibody titers and antigen batches was also evaluated, giving satisfactory results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The records of the first two Colombian patients with AIDS and paracoccidioidomycosis are presented. Both patients were males and had no known risk factors for HIV although in the past they had worked in the field where they could have been infected with the fungus. They exhibited the juvenile type of disease with multiple organ system involvement and symptoms of short duration. They were deeply immunodepressed as indicated by less than 100 CD4 T lymphocytes per mL; however, serologic tests revealed circulating anti-Paracoccidioides brasiliensis antibodies and in one patient the first diagnostic clue came from such tests. In one case, the mycosis preceded the AIDS diagnosis while in the other, both pathologies were discovered simultaneously. Antimycotic therapy with itraconazole was administered for over 10 months, with an initial dose of 200 mg/day followed by 100 mg/day; marked improvement of the mycotic signs and symptoms was soon noticed an there have been no signs of relapse. The patients´ improvement was also due to the combined retroviral treatment that was instituted. In spite of the rarity of the AIDS-paracoccidioidomycosis association, physicians practicing in endemic areas should consider the presence of the mycosis in immunosuppressed patients, since a prompt diagnosis and institution of combined antimycotic-anti-retroviral treatments would result in patient improvement and survival. It appears possible that the longer survival time of today's AIDS patients would give the quiescent fungus the opportunity to revive, multiply and cause overt disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated the usefulness of the anti-HBc, hepatitis C virus antibodies (anti-HCV), human T cell lymphotropic virus I and II antibodies (anti-HTLV I/II), serologic tests for syphilis, and surface antigen of hepatitis B virus (HBsAg) as surrogate markers for the risk for HIV infection in 80,284 serum samples from blood donors from the Blood Bank of "Hospital Universitário Regional Norte do Paraná", Londrina, Paraná State, Brazil, analyzed from July 1994 to April 2001. Among 39 blood donors with positive serology for HIV, 12 (30.8%) were anti-HBc positive, 10 (25.6%) for anti-HCV, 1 (2.6%) for anti-HTLV I/I, 1 (2.6%) was positive for syphilis, and 1 (2.6%) for HBsAg. Among the donors with negative serology for HIV, these markers were detected in 8,407 (10.5%), 441 (0.5%), 189 (0.2%), 464 (0.6%), and 473 (0.6%) samples, respectively. The difference was statistically significant (p < 0.001) for anti-HBc and anti-HCV. Although the predictive positive value for these surrogate markers were low for HIV infection, the results confirmed the anti-HBc and anti-HCV as useful surrogate markers for HIV infection thus reinforcing the maintenance of them in the screening for blood donors contributing to the prevention of the small number of cases in which HIV is still transmitted by transfusion.